GE
Sensing
Pressure Measurement
Operating Pressure Ranges
PDCR 1730 (mV)/PTX 1730 (mA)
5, 10, 15, 20, 30, 50, 75, 100, 150, 300, 500, 900 psi gauge
Overpressure
The operating FS pressure range can be exceeded by the
following multiples with negligible effect on calibration.
• 4 x for 5 psi range
• 2 x for ranges 10 to 900 psi
Pressure Containment
• 10 x for 5 psi range
• 4 x for ranges up to 900 psi (2000 psi maximum)
Media Compatibility
Fluids compatible with 316 stainless steel, polyurethane
(cable) and EPDM (nose cone).
Excitation Voltage
PDCR 1730 (mV)
10 V at 1 mA nominal
Output is fully ratiometric to supply within 2.5 V to 12 V
limits.
PTX1730 (mA)
9 to 30 VDC across terminals
For pulse power operation refer to technical note.
The minimum supply voltage (V
MIN
) which must appear
across the pressure transmitter terminals is 9 V and is
given by the following equation:
V
MIN
= V
SUP
- (0.02 x R
LOOP
)
Where V
SUP
is supply voltage in Volts, R
LOOP
is total loop
resistance in Ohms
1730
Specifications
Output Signal
PDCR 1730
• 50 mV for 5 psi range
• 100 mV for ranges 10 psi and above
PTX 1730
4 to 20 mA proportional for zero to FS pressure
Common Mode Voltage - PDCR 1730
Nominally 50% of excitation voltage
Output Impedance - PDCR 1730
5 kΩ nominal
Performance Specification
Accuracy
Combined effects of Non-linearity, Hysteresis and
Repeatability: ±0.25% FS BSL max
Zero Offset & Span Setting
PDCR 1730
Typical: ±1.5 mV
Maximum: ±3 mV
PTX 1730
Maximum: ±0.1 mA
Long-Term Stability
±0.2% FS typical per annum
Operating Temperature Range
-4 to 140°F (-20 to 60°C)
Compensated Temperature Range
30 to 85°F (-1 to 30°C)
Temperature Effects
±0.5% FS Temperature Error Band (TEB)
Shock and Vibration
MIL-STD-810E, method 514.4. Category 10 min.
integrity. Figure 514.4-16
Product will withstand 20 g peak shock half sine wave
ms duration in all axes,
Insulation
Greater than 100 MΩ at 500 VDC