DoorKing 1603-210 Installation Manual

Support
Post
Bracket
Bracket
Cover
U-Bolt Clamp
U-Bolt Clamp
Route wire
conduit.
Support Post Assembly
Use existing
circuit board
bracket bolts
to mount
support post
bracket.
Drill 7/8” hole centered where elbow touches operator housing (Approximately 18” down from the top of operator). Secure 3/4” conduit nipple in drilled hole with conduit nut .
2” conduit nut to secure elbow.
Use 2” conduit nuts to secure traffic light assembly to support post.
Route wire through support post.
Traffic Light Assembly
2” Elbow
Shut off AC power to operator. Turn off DC power switch on certain models.
This kit is designed for the 1600 model barrier gate operators. Recommended for the 1603 auto spike system. The traffic signal is synchronized with the gate operator’s up/down cycle. The red light stays on and only changes to green when the operator’s arm is fully raised.
2” Threaded Elbow
2” Conduit Nut (3)
5/8” Cover Bracket bolt and lockwasher (2 sets)
3/4” Conduit Nipple and Conduit Nut
U-Bolt Clamp with lockwashers and nuts (2 sets)
Kit Includes:
Plastic Traffic Light Assembly (Factory wired) 2” Threaded Support Post Support Post Bracket Bracket Cover.
Hardware:
TRAFFIC LIGHT AND MOUNTING KIT
Installation
DoorKing Part Number
1603-210
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Assemble Support Post Mount Support Post Assembly to Operator
Support Post
1 2
www.leedan.com info@leedan.com Toll-Free: 800-231-1414
REVERSE SENSITIVITY
TIME DELAY
SW 1
SW 2
POWER
1
ON
2 3 4 5 6 7 81
ON
2 3 4 5 6 7 8
NC NO
NONCC
UP LOOP
DOWN LOOP
1234567891011121314
1601
Chassis Ground
ON
OFF
AC POWER DC POWER
ON
AUTO
DOWN
UP
OFF
NEU HOT
Red Wire (Com)
Brown Wire (N.O.)
Note: To reverse light sequence change to N.C.
(Ground) Green Wire
(Neutral) White Wire
(Hot) Black Wire
3/4” Conduit nipple installed in operator housing.
Circuit Board Bracket Bolt
Circuit Board Bracket Bolt
115 VAC
DANGER
HIGH VOLTAGE!
Chassis Ground
230/460 VAC
115 VAC Hot
Neutral
Neutral
12345
(Ground) Green (Neutral) White (Hot) Black
Red and Brown wire are the same as the 115 VAC installation.
Keep wire clear of all moving parts.
Note: This light has been designed to wire to operators that use 115 volt power and a FORM C dry relay contact that activates when the operator is fully open.
1603-265-B-6-08
DoorKing Part Number
1603-210
Copyright 2008 DoorKing, Inc. All rights reserved.
120 Glasgow Avenue
Inglewood, California 90301 U.S.A.
Wire Traffic Light to Operator
Circuit Board Bracket
3
www.leedan.com info@leedan.com Toll-Free: 800-231-1414
Loading...