Dometic MasterFlush Series, MF 7100 Series, MF 7200 Series Quick Start Manual

1
Quick-Start Guide
MasterFlush® Series
Toilets with ORBIT Base
MF 7200 Series
MF 7100 Series
Quick-start guide ..............2
EN
WC dilacérateur
Guide de démarrage rapide ......5
FR
Inodoro triturador
Guía de inicio rápida . . . . . . . . . . .8
ES
2
Normal flushing
Press “Flush” switch (2) down and hold until waste drains from toilet bowl (about 10 – 20 seconds). This switch activates a macerator pump that siphons water and waste from the bowl, macerates, and propels the efuent to the discharge line.
To use less water for liquid-only ushes, press “Flush” switch for shorter period of time.
If toilet bowl does not completely flush and lls up with sea water during ush, partially close inlet valve until bowl clears and completely discharges efuent. Then, with inlet and discharge valves completely open, ush toilet for a few seconds to clear toilet and discharge system.
Toilet system start-up
1. Open sea water inlet and toilet discharge outlet seacocks.
2. Press “Flush” switch (2) and hold until water enters the toilet bowl.
3. Toss several sheets of toilet paper into bowl and repeat cycle. The bowl should completely clear.
Toilet system start-up
1. Turn on fresh water supply to toilet.
2. Press “Flush” switch (1) and hold until water enters the toilet bowl.
3. Toss several sheets of toilet paper into bowl and repeat cycle. The bowl should completely clear.
Normal flushing
Press “Flush” switch (1) down and hold until waste drains from toilet bowl (about 10 – 20 seconds). This switch activates a macerator pump that siphons water and waste from the bowl, macerates, and propels the efuent to the discharge line/ holding tank.
To use less water for liquid-only ushes, press “Flush” switch for shorter period of time.
MasterFlush Operation
Freshwater Flush (7120, 7220)
2
1
Sea Water Flush (7160, 7260)
Caution! Hazard of Flooding
If toilet is connected to ANY through-the-hull ttings, ALWAYS close sea­cocks when toilet is not in use (even if boat is unattended for a brief period). All passengers MUST be instructed on how to close valves when the toilet is not in use. Failure to do so can result in ooding which can cause loss of property and life.
EN
3
DO NOT FLUSH FOREIGN OBJECTS
CAUTION! Flush only water, bodily wastes and rapid-dissolving tissue
paper. Do not flush wet wipes, sanitary napkins, condoms, diapers, razor blades, paper cups, cotton swabs, food, hair or liquids such as oils or solvents. Clogging or damage to the toilet system may occur.
Note
Make sure all guests understand toilet operation before use.
Use RAPID-DISSOLVING toilet tissue – avoid clogs
To avoid potential clogging problems with some household tissues, Dometic recommends the use of quick-dissolving tissue, such as Dometic rapid-dissolving 1-ply or 2-ply toilet tissue.
IMPORTANT! NOT EVERY MARINE-GRADE TOILET PAPER DISSOLVES RAPIDLY
To determine any tissue’s ability to dissolve, immerse one square of tissue in a jar of water and shake 5-10 times. The tissue sample should break up so that it is no longer in one piece.
Troubleshooting
Problem Possible Cause Service Instruction
1. Flush function works, but water in bowl empties slowly or not at all.
a. Discharge piping is pinched or
kinked.
b. Discharge piping is too high.
(Remember, all upward vertical loops and should not exceed a total of 4 feet (1.2 m) in height.)
c. The macerator pump or
discharge piping is blocked.
a. Check discharge piping.
b. Reroute discharge piping.
c. Close seacocks and clear
blockage.
2. Macerator pump makes unusually loud noise or continually trips breaker.
a. Foreign material in pump
chamber.
a. Close seacocks and clear
foreign material.
3. Flush cycle is not activated after pushing on ush switch.
a. Holding tank is full and signal
from tank has shut down electrical power to toilet.
b. Electrical power to toilet is shut
off or disrupted. c. Flush switch is malfunctioning. d. Electric motor is malfunctioning.
a. Empty holding tank.
b. Check wiring and circuit
breakers (or fuses). c. Replace ush switch. d. Replace electric motor.
4. Insufcient or no water enters the bowl.
a. Water supply line is pinched or
kinked.
b. Screen in water valve is blocked.
c. Intake water lters are blocked
(in raw water system).
d. Water valve is malfunctioning
(fresh water ush toilet).
e. Water impeller is malfunctioning
(raw water ush toilet).
a. Check water supply line.
b. Clear blockage at water
valve.
c. Clear water lters.
d. Replace water valve.
e. Replace raw water
impeller.
4
There is a strong, worldwide network to assist in servicing and maintaining your sanitation system. For the Authorized Service Center near you, please call from 8:00 a.m. to 5:00 p.m. (ET) Monday through Friday.
You may also contact or have your local dealer contact the Parts Distributor nearest you for quick response to your replacement parts needs. They carry a complete inventory for the Dometic Sanitation product line.
Telephone: 1 800-321-9886 U.S.A. and Canada 330-439-5550 International
Fax: 330-496-3097 U.S.A. and Canada 330-439-5567 International
Web sites: http://www.Dometic.com http://www.DometicSanitation.com
Customer service
During extended periods of non-use
The macerator toilet and sanitation hoses should be protected if toilet will not be needed for an extended period of time (more than two weeks, especially in hot weather).
1. Flush toilet and add 4 oz. (118 ml) of liquid biodegradable laundry detergent (should NOT contain bleach or environmentally harmful substances). Note: If using raw water for ushing, shut off power to raw water pump and add fresh water directly into the bowl during the ush cycle.
2. Flush toilet at least ve times.
3. Turn off water supply to toilet.
4. Flush the toilet without water very briey to evacuate all water. (This procedure will minimize any remaining water in the macerator pump.)
Caution
During water evacuation process, do not operate raw water pump very long without water. Pump impeller may become damaged.
5. Turn off power to the toilet.
6. After extended periods of non-use, toilet and pump may dry. For easier re-start of toilet system, add one quart of water to bowl and let it stand for a few minutes before use.