Before rst use
Open the battery compartment cover (6) in the direction of the
arrow and remove the protective paper between the contacts
and the battery (8). Connect the contacts to the battery and
put the battery compartment cover (6) back on. The device is
now ready to use.
Operating the wood moisture meter
Push the cap (5) tab where it says (UP) and take off the cap.
Press the ON/OFF switch (1).
Press the two test pins (7) into the wood surface with slight
pressure. The moisture content of the wood will be shown on
the display (3) in percent.
The reading can be stored until the next measurement by
pressing the memory button (2). Pressing the button again
deletes the reading.
To get a correct reading of the inside of the wood, split it and
measure the interior surface. Take readings at 3 places to get
an average. The meter can be used on all wood surfaces.
After measurement is completed switch the meter off and put
the cap (5) back on!
Readings for rewood:
5-15 % = Very good for heating
16-20 % = Can be used for heating with some limitations
21-40 % = Not suitable. Needs further drying.
Form: 995 711 022 (5.11 DE, GB)
Wood moisture meter MM-400
Read carefully before using the meter!
Caution:
The test pins (7) are very sharp. Risk of injury! Keep the me-
ter away from children! Never direct the test pins at people
or animals!
Note:
If the meter is not going to be used for an extended period,
take the battery out. When the battery symbol (4) appears,
the battery (8) needs to be replaced by a new 9volt battery.
Do not put batteries in household waste!
Per European Guideline 2002/96/EG on old electrical and
electronic devices, 2006/66/EG on batteries and old batteries, and the national legislation based on them, old electric
tools and batteries must be collected separately for environ-
mentally appropriate recycling.
Protect the meter from moisture, and store it in a dry place.
Wipe off any dirt with a damp cloth.
If necessary, remove the protective lm on the display (3).
If necessary, replace the test pins (9). To do so, use a suitable tool to remove the old pins by turning them counter
clockwise. Replacement test pins are available under order
number 988 050 517.
Components
1 ON/OFF switch
2 Reading memory
3 Digital display
4 Battery status display
5 Cap
6 Battery compartment cover
7 Test pins
8 9V battery
9 Spare test pins
(available as accessories)
Technical data
Measuring range: 5% – 40%
Display: 1% increments
Precision:
520% = +/2%, 2140% = +/1%
Temperature range for use: 0°C – 40°C
Dimensions: 129 x 63 x 32mm
Weight: 116 g with battery
1
2
6
7
8
9
3
4
5
DOLMAR GmbH
Postfach 70 04 20
D-22004 Hamburg
Germany
http://www.dolmar.com
approx. 5 cm