D-Link ANT24-0800, DWL-50AT, DWL-M60AT, DWL-R60AT, DWL-1500 Antenna Installation Manual

...
CAUTION!! Please always put the surge protector indoors and near the device side, if you cannot keep it indoors, use the tapes to wrap all the connectors as pictures showed below.
Option: Ultra low-loss cable LMR400 Length options: 3M/6M/9M
Option: Surge protector Connectors: N-plug to N-jack
ANT24-SP Surge protector Installation guide for outdoor antenna-kit
Step 1 loosen the screw from the surge protector.
Step 2 get a normal conductive copper wire with 2 sides stripped long enough to be conductive, these wires can lead high voltage surges into the grounding.
Remark: (1) for the ground screw you use, we suggest the longer (deeper into ground) the better performance it has. (2) please use a copper wire with diameter at least from 2.0mm, the thicker the diameter, the higher voltage it can sustain.
Option (1)
Option (2)
Ground
Step 3 find a conductive material nearby the antenna installation sites, connect another end of the wire into position, there are several options: (1) Use a long screw to stick into the ground tightly, connect another wire onto. (2) fix or solder another end of wire onto a steel material/ bar under steel construction, such as wall for buildings, railings or other conductive materials which set up from the ground.
Silver to Antenna
Golden to Device
To have correct connection of the attached extension cable (Based on connector color management)
Loading...