Desa AC 9410 EH, AC 12410 EH Instruction Manual

DESA UK Ltd, Warrington, England
INSTRUCTION MANUAL
AC 9410 EH AC 12410 EH
Please read and retain these instructions for future reference
PORTABLE AIR CONDITIONER
2
INDEX
Index 2
Specification 3
Safety Information 4
Parts 5
Installation of the Exhaust Pipe 6
Mounting of the Exhaust Pipe 7
Installation of the Carbon Filter 8
Operation 9
Setting the Fan Speed 10
Setting the Timer 10
Regulating the Airflow 10
Drainage 11
Maintenance 13
Fault Check List 14
3
SPECIFICATION
Model AC9410-EH AC12410-EH Power Supply (Ph, V~Hz)
1Ph, 220-
240V, 50Hz
1Ph, 220-
240V, 50Hz
Capacity (BTU/hr) 8,000 10,000 Power Consumption (W) 830 1,030 Operating Current (A) 3.7 4.5 EER (BTU/w.h) 2.88 2.75
Cooling
Working Temperature (oC)
18 - 32 18 - 32
Capacity (BTU/hr) 8,000 10,000 Power Consumption (W) 870 1,180 Operating Current (A) 3.9 5.2 COP (BTU/w.h) 2.88 2.61
Heating
Working Temperature (oC)
5 - 27 5 - 27
Airflow Volume M3/hr 350 350 Dehumidifying L/hr 1.2 1.5 Refrigerant g/R410a 530 540 Noise Level db(A) 54 54 Dimensions WxHxD (mm) 400x750x377 400x750x377 Packing WxHxD (mm) 460x780x450 460x780x450 Net Weight (kg) 30 32
Suitable Area M2 18-26 30-36
Please note:
1. Information may vary for technical reasons
2. Measuring condition for above is based on regulation EN14511
4
SAFETY INFORMATION
General Safety
Only use in an upright position on a flat, level surface
Always use the carry handles to move the product and NOT the electricity
cable
Do not place objects on the unit or restrict the air inlet/outlet
Always supervise children and pets when the unit is in use
Electrical Safety
For Indoor use only
Always switch the unit off and unplug when not in use
Do not use in overly humid or wet environment
If the power lead is damaged, it must be replaced immediately by a
qualified electrician
For Maximum Efficiency
Do not exceed the recommended room size of 50m3 (typically 20m2 floor area)
Close all doors and windows in the room with the operating air conditioner unit
Keep curtains and blinds closed if the room is in direct sunlight
Keep filters clean
Once the room has reached the desired conditions, change the
temperature and ventilation settings as required
Ensure the unit is at least 50cm from any object
5
PARTS
Front Back
1. Control Panel
2. Air outlet
3. Carrying handle
4. Caster
5. Air filter
6. Air inlet
7. Exhaust air outlet
8. Cord storage
9. Drainage point
Accessories
10. Inward adaptor - inserts
over hose and i
nto back of
the air conditioner
11. Outward adaptor - inserts
over hose and into foam strip (supplied)
12. Extendable exhaust hose
13. Foam strip – allows the
exhaust hose to be held in
place in an open window
14. Round cap for filling the
hole in wall/window, when the unit is not in use
15. Drain tube for continuous
drainage
16. Water tray
17. Active carbon filter
18. Remote control