DESA UK Ltd, Warrington, England
INSTRUCTION MANUAL
AC 9410 EH
AC 12410 EH
Please read and retain these instructions for future reference
PORTABLE AIR CONDITIONER

INDEX
• Index 2
• Specification 3
• Safety Information 4
• Parts 5
• Installation of the Exhaust Pipe 6
• Mounting of the Exhaust Pipe 7
• Installation of the Carbon Filter 8
• Operation 9
• Setting the Fan Speed 10
• Setting the Timer 10
• Regulating the Airflow 10
• Drainage 11
• Maintenance 13
• Fault Check List 14

SPECIFICATION
Model AC9410-EH AC12410-EH
Power Supply (Ph, V~Hz)
1Ph, 220-
240V, 50Hz
1Ph, 220-
240V, 50Hz
Capacity (BTU/hr) 8,000 10,000
Power Consumption (W) 830 1,030
Operating Current (A) 3.7 4.5
EER (BTU/w.h) 2.88 2.75
Cooling
Working Temperature (oC)
18 - 32 18 - 32
Capacity (BTU/hr) 8,000 10,000
Power Consumption (W) 870 1,180
Operating Current (A) 3.9 5.2
COP (BTU/w.h) 2.88 2.61
Heating
Working Temperature (oC)
5 - 27 5 - 27
Airflow Volume M3/hr 350 350
Dehumidifying L/hr 1.2 1.5
Refrigerant g/R410a 530 540
Noise Level db(A) ≤54 ≤54
Dimensions WxHxD (mm) 400x750x377 400x750x377
Packing WxHxD (mm) 460x780x450 460x780x450
Net Weight (kg) 30 32
Suitable Area M2 18-26 30-36
Please note:
1. Information may vary for technical reasons
2. Measuring condition for above is based on regulation EN14511

SAFETY INFORMATION
General Safety
• Only use in an upright position on a flat, level surface
• Always use the carry handles to move the product and NOT the electricity
cable
• Do not place objects on the unit or restrict the air inlet/outlet
• Always supervise children and pets when the unit is in use
Electrical Safety
• For Indoor use only
• Always switch the unit off and unplug when not in use
• Do not use in overly humid or wet environment
• If the power lead is damaged, it must be replaced immediately by a
qualified electrician
For Maximum Efficiency
• Do not exceed the recommended room size of 50m3 (typically 20m2 floor
area)
• Close all doors and windows in the room with the operating air conditioner
unit
• Keep curtains and blinds closed if the room is in direct sunlight
• Keep filters clean
• Once the room has reached the desired conditions, change the
temperature and ventilation settings as required
• Ensure the unit is at least 50cm from any object

PARTS
Front Back
1. Control Panel
2. Air outlet
3. Carrying handle
4. Caster
5. Air filter
6. Air inlet
7. Exhaust air outlet
8. Cord storage
9. Drainage point
Accessories
10. Inward adaptor - inserts
over hose and i
the air conditioner
11. Outward adaptor - inserts
over hose and into foam
strip (supplied)
12. Extendable exhaust hose
13. Foam strip – allows the
exhaust hose to be held in
place in an open window
14. Round cap for filling the
hole in wall/window, when
the unit is not in use
15. Drain tube for continuous
drainage
16. Water tray
17. Active carbon filter
18. Remote control