Desa AC 10 R, AC 12 R, AC 12 EHP, AC 90 E, AC 120 E Instruction Manual

...
Please read and retain this manual for future reference
PORTABLE AIR CONDITIONER
AC 10 R / AC 12 R / AC 12 EHP
INSTRUCTION MANUAL
Downloaded from AC-Manual.com Manuals
Model AC 12 EHP AC 10 R AC 12 R
Cooling capacity * 3500 W 2930 W 3500 W
Heating capacity * 3210 W - -
Power/Ampere consumption for cooling * 1230W / 5.5A 1040 W / 4.7A 1230 W / 5.5A
Power/Ampere consumption for heating * 1140W / 5.0A - -
Air volume 400 m3/h
Humidity removal capacity* 1.8 l/h 1.2 l/h 1.4 l/h
Recommended room size 70 m3 55 m3 70 m3
Power supply 220-240V, ~50Hz
Compressor rotary
Refrigerant R410a
Fan speed 3
Timer 24 h
Working temperature Cooling: 18 ÷ 32oC
Heating: 5 ÷ 27oC
Sleep function yes
Active carbon filter yes
Exhaust pipe Dia: 127 x 1500 mm
Net Weight 32 kg 30 kg 32 kg
Dimension 482 x 380 x 750 mm
1
REMARK:
1. The data marked with '*' may vary for technical reasons: for greater precision, please refer to the rating label placed at the back of the unit.
2. Measuring condition for above is:
o o o o
Cooling DB 27 C, WB 19 C, Heating DB 20 C, WB 12 C
Downloaded from AC-Manual.com Manuals
2
BEFORE USE
GENERAL SAFETY
Electrical safety
FOR MAXIMUM EFFICENCY
! Only use in the upright Position on A flat
level surface and At least 50cm FROM ANY OBJECTS (Fig 1 & 4).
! Do not PLACe objects on the unit or
RESTRICT AIR INLET / outlet (fig. 2).
! Closely supervise any children AND PETS
when UNIT is in use.
! For indoor use only. ! Switch off and unplug when not in use. ! Do not use in humid or wet environments
(Fig 3)
! Do not pull the UNIT along by the cord. ! IF THE SUPPLY CORD IS DAMAGED, IT
MUST BE REPLACED BY AN ELECTRICIAN OR SIMILARLY QUALIFIED PERSON, TO AVOID HAZARD.
! Do not exceed the recommended room size ! Close doors and windows ! Keep curtains of blinds closed during the
sunniest part of the day
! Keep filters clean ! Once room has reached the desired
conditions, reduce temperature and ventilation settings
Fig. 1.
Fig. 2.
Fig. 3.
Fig. 4.
Downloaded from AC-Manual.com Manuals
3
PARTS
1. Control Panel
2. Air outlet
3. Carrying handle
4. Caster
5. Filter frame for Evaporator Air Inlet
6. Filter frame for Condenser Air Inlet
7. Cord hanger
8. Water stopper for water tray (Dehumidifying
water)
9. Adaptor for Exhaust pipe (exhaust pipe to be fixed here)
10. Water stopper
11. Inward adaptor - for insertion over hose and
into back of the air conditioner.
12. Outward adaptor - for insertion over hose and into foam strip (or into hole in the wall/window).
13. Exhaust hose
14. Round cap for filling the hole in wall/window.
15. Drain tube for continuous drainage
16. Remote control (for electronic type only)
17. Foam strip - for filling the open window space
and with hole for connection to exhaust hose.
18. Active carbon filter
Front
Back
Accessories
Downloaded from AC-Manual.com Manuals
INSTALLATION
4
Installation of the exhaust pipe
The unit is a portable air conditioner that may be moved from room to room.
1. Using the foam strips
Foam strips
! Offer foam strips to the window gap and cut to size if necessary. ! Feed exhaust hose through the foam strip and insert strip into window gaps as shown and
slide window across so that foam is held securely. This technique may also be used for sash windows.
Note: Take care to maintain protection against intruders
2. Using the adaptor
Wall or Window
Outward adaptor
! Cut a 136mm diameter hole in the wall or window. ! Feed exhaust hose through the window or wall and attach the threaded adaptor from the
outside as shown.
! When not in use, plug the hole with the cover provided.
Fig. 8.
Fig. 9.
Fig. 10.
Downloaded from AC-Manual.com Manuals
Loading...