Desa 5525 User Manual

®
Motion Sensing Halogen Fixture
Model 5525
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
This package includes:
Plastic Hanger
6 Screws
(3 sizes included)
1 Halogen
Lamp
Sensor
3 Wire
Connectors
Mounting Strap
Mounting Bolt
Light Shield
Gasket
Light Control
Rubber Plug
OPERATION
Mode: On-Time Works: Day Night
Test Auto Manual
Note: When fi rst turned on wait about 1 the circuitry to calibrate.
Put the ON-TIME switch on the bottom of the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, or 10 minute position.
Manual mode only works at night because daylight returns the sen­sor to AUTO.
Flip the light switch off for one sec­ond then back on to toggle between AUTO and MANUAL MODE.
Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.
5 Seconds x x
1, 5, or 10 Min x
Until Dawn* x
* resets to Auto Mode at dawn.
1
/2 minutes for
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
MANUAL MODE
1 Second OFF
... back on.
Mode Switch Summary
then...
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be wired through a switch.
• Some codes require installation by a qualifi ed electrician.
• This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali­bration time the control will be in the AUTO mode.
© 2007 DESA Specialty Products™ 598-1311-00
TEST
AUTO
MANUAL MODE
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch
off for one second
then back on*
INSTALLATION
For easy installation, select an existing light with a wall switch for replacement.
For best performance, mount the fi xture about 8 ft. (2.4 m) above the ground.
CAUTION: To Avoid Fire Or Burn Hazards:
• Allow fi xture to cool before touching. The bulb and the fi xture operate at high temperatures. Keep fi xture at least 1" (2.5 cm) from combustible ma-
• terials. Do not aim at objects closer than 3 ft. (1 m).
• Use only T3, 250W (max.) tungsten halogen 120 VAC lamps.
BULB INSTALLATION
When relamping, turn power off and let the fi xture
cool.
Remove glass cover and remove the old bulb by
pushing the bulb towards the socket indicated on the metal refl ector.
To inser t the new bulb, follow the instructions printed
on the metal refl ector.
Check that the bulb is seated properly.Reinstall the glass cover.
WIRE THE LIGHT CONTROL
Note the position of the various parts of the fi xture for
the type of installation for your application and adjust the lamp head and sensor as shown below.
Wall Mount
Lens Retainer
Light Shield,
with opening at
this side
For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock. Also for proper under eave operation, remove the protective backing
from the Light Shield and stick on as shown below. For eave mount only:
Swing the sensor head towards the clamp screw
joint.
Clamp Screw
Eave Mount
Lens Retainer
Controls
WARNING: Turn power off at circuit breaker
or fuse.
Remove the existing light fi xture.Install mounting strap to junction box using screws
appropriate for your junction box.
The plastic hanger can be used to hold the fi xture
while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.
Thread all fi xture wires through the large holes in
the gasket as shown.
Connect the junction box wires to the light fi xture
wires as shown. Twist together and secure with wire connectors.
Mounting Strap
Black to Black
White to White
Rubber
Plug
Then rotate the sensor head clockwise 180° so
the controls face down.
Controls
Light Shield
Opening
Controls
If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.
Mounting
Bolt
Gasket
Connect any fi xture ground wire(s) and the cover plate ground screw to the junction box ground wire.
MOUNT THE LIGHT CONTROL
Align the Light Control cover plate and cover plate
gasket. Secure with the mounting bolt.
Push the Rubber Plug fi rmly into place. If a wet location junction box was not used, caulk
the wall plate mounting surface with silicone weather sealant.
2
598-1311-00
TEST AND ADJUSTMENT
Turn on the circuit breaker and light switch.
NOTE: Sensor has about 1 1/2 minutes warm up period
before it will detect motion. When fi rst turned on, wait about 1 1/2 minutes.
Turn the RANGE control to the mid position and
the ON-TIME control to the TEST position.
ON-TIME
10 5 1 TEST
Bottom of Sensor
Avoid aiming the control at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat sources could cause false triggering.
• Areas where pets or traffi c may trigger the control.
Nearby large, light-colored objects refl ecting light
may trigger the shut-off feature. Do not point other lights at the sensor.
8 ft.
(2.4 m)
70 ft.
(21 m)
Maximum Range Maximum Coverage Angle
RANGE
MIN MAX
180°
Loosen the clamp screw in the
sensor ball joint and gently rotate the sensor.
Walk through the coverage area
noting where you are when the lights turn on (also, the LED will fl ash several times when motion is detected). Move the sensor head up, down, or sideways to change the coverage area. Keep
the sensor at least 1" (2.5 cm) away from the lamp.
Adjust the RANGE as needed.
RANGE set too high may increase false triggering.
Secure the sensor head by
tightening the clamp screw.
Do not overtighten the screw.
Set the amount of TIME you
want the lights to stay on after motion is detected (1, 5, or 10 minutes).
Down for Short
Higher for Long
Clamp Screw
Ball Joint
Aim Sensor
Coverage
Aim Sensor
Coverage
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 70 ft. (21 m) [varies with
surrounding temperature].
Sensing Angle . . . . . . . Up to 180°
Electrical Load . . . . . . . Up to 250 Watts Maximum
Incandescent. Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
MODE
Time Delay . . . . . . . . . 1, 5, 10 minutes
Replacement lamp . . . . T3, 250W (or less) halogen
120 VAC DESA Specialty Products reserves the right to dis-
continue products and to change specifi cations at any time without incurring any obligation to incorporate new features in products previously sold.
The detector is most sensitive to motion across its fi eld of view.
Motion
Sensor
Motion
Least Sensitive Most Sensitive
598-1311-00
3
Loading...
+ 5 hidden pages