Denon DP-6000, DP-6700 Service Manual

Specifications and Main Features

Model: DP-6000

Drive Types: Direct Drive

Control System: Quartz Crystal Control system

Times Base Oscillation Frequency: 33.75 kHz

Speed Settings: 33 1/3 RPM, 45 RPM

45 RPM Divide For Frequency:187.5 Hz through divide by 180 Counter

33 1/3 RPM Divide For Frequency:183.8Hz thordg divide by 243 Counter.

High Precision Crystal Oscillation: Error less than 0.002% (1/50,000)

Stable Temperature and Humidity Affects: No require Readjustment.

Speed Adjustability: Manual variable adjustment of over 46% from the nominal speeds

Adjustable Voltage Supply: 5V to 5.2V using VR3.

Electric Brake Working: Reduces reach standard revolution time.

STOP Control Circuit: Brake operation time 3 - 4 seconds.

Measuring speed used Combination Binary and Trinary Counters.

Advance PWM Modulation with Servo Switching Circuit: Accuracy and stability of sound is enranced.

Frequently Asked Questions

Q: Which approximate speed can this turntable work maximum?

A: DP-6000 turntable can work in maximum speeds of 45 RPM.

  • Q: In what manner does the quartz crystal control system operate?

A: The quartz controlled alarm system has a division ratio of 33.75 kHz which is then divided down to meet the required oscillation frequencies.

  • Q: Is there a limitation to how much the turntable's speed can be altered?

A: However, the turntable will offer its users a means through which they can manually control its speed and has ranges for its speed of approximately 20 percent on either side of the mean speed.

  • Q: What is the function of the electric brake?

A: The electric brake is essential for limiting the time required for the turntable to achieve the standard revolution speed when the switch 33 1/3 rpm to 45 rpm is pressed.

  • Q: Does crystal oscillator have any maintenance requirement?

A: The crystal oscillator does not require any change in settings as they are capable of adjusting itself with changes in temperature or humidity which makes it a low maintenance device.

  • Q: For how many seconds is the brake operation set when the STOP button is pressed?

A: It was approximately calculated that the period of time consumed in the brake operation is 3-4 seconds.