Delonghi PACT 40 Instructions Manual

14
Warnings
• This appliance is designed for home air conditioning and must not be used for other purposes.
• It is dangerous to modify or alter the characteristics of the appliance in any way.
• The appliance must be installed in conformity with legislation in force in the country concerned.
• If the appliance requires repair, contact a Service Centre authorised by the manufacturer only. Repairs carried out by unauthorised personnel may be dangerous.
• The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure that they do not play with the appliance.
• The appliance must be connected to an efficient earth system. Have your electrical circuit checked by a qualified electrician.
• Do not use extension cables.
• Before cleaning or maintenance operations, always unplug the appliance from the mains socket.
• Do not move the appliance by pulling the power cable.
• Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat.
• Do not rest heavy or hot objects on top of the appliance.
• Clean the anti-microbial filters at least once a week.
•Avoid using heating appliances near the air conditioning unit.
• Always transport the appliance upright or resting on one side. Before transporting the appliance, completely empty the internal circuit of water by turning the function selector to the PUMP position until you hear the gurgling of the pump.
• Use the appliance as described in this instruction manual only. As with all electrical equipment, whil­st the instructions aim to cover as many eventualities as possible, caution and common sense should be applied when operating and installing this appliance.
• At the end of its working life, take the appliance to a special collection centre.
• The materials used for packaging can be recycled. You are therefore recommended to dispose of them in special differentiated waste collection containers.
• When putting the appliance away, do not cover with plastic bags.
• R407 is a refrigerant gas conforming to EC environmental regulations. Avoid perforating the refrige­rant circuit of the appliance.
• If the appliance is used in rooms without adequate ventilation, take the necessary precautions to avoid possible leaks of refrigerant gas stagnating in the atmosphere, creating a fire risk.
• This appliance must be used and kept in rooms with a volume of more than 21 m
2
.
• If an appliance containing flammable refrigerant is used in an unventilated room, make sure the room is suitable and that there is no danger of gas leaks reaching a concentration which could cause fire or explosion in the presence of other heat sources (electrical heating appliances, heaters or similar).
DESCRIPTION 1 Control panel
2 Air outlet grille 3 Evaporator air intake grill 4 Housing for air exhaust hose 5 Condenser air intake grill 6 Continuous condensate drain connection 7 Condensate tank 8 Power cable 9 Castors 10 Handles 11 Air conditioning light 12 Dehumidification light 13 Fan light
14 Function selector 15 Thermostat dial 16 Timer 17 Tank full/tank absent light 18 Alarm light 19 Power on light 20 Flange cap 21 Air exhaust hose 22 Window outlet 23 Suckers 24 Castor locks 25 Continuous drain hose with coupling
GB-5751013500 27-07-2006 18:10 Pagina 14
15
ENGLISH
During the summer, you feel comfortable at a tem-
perature of between 24 and 27° C with a relative humidity of about 50%. An air conditioning unit removes excess moistu­re and heat from the room where it is loca­ted. Compared with installed models, porta­ble air conditioning units have the advantage that they can be moved from one room to another in the home or transported from one building to another. Hot air from the room is passed throu­gh a coil cooled by refrigerant gas. Excess heat and moisture are remo­ved before the air is re-emitted into the room. In single unit models (Pinguino), a small part of this air is used to cool the refrigerant gas and then once hot and moist, is discharged outside. In models with case (SuperPinguino), the circuit is cooled using air from outsi­de. All Pinguino and SuperPinguino models can also be used in fan-only mode.
What are the Pinguino and SuperPinguino?
GB-5751013500 27-07-2006 18:10 Pagina 15
16
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is ensured with Pinguino:
• Fix the air discharge hose in the housing
at the back of the appliance. Insert it as
shown in figure A.
4
21
• If you have a double window, use the suckers provided to hold the two parts of the window together (fig. C).
23
• Fit the window outlet to the end of the hose .
• Place the air conditioning unit near a win­dow or French window.
• Make sure the air exhaust hose is unob­structed.
• Open the window or French window sligh­tly and position the outlet as shown in figure B.
21
22
21
A
Preparing for use
B
C
ELECTRICAL CONNECTIONS
Before plugging the appliance into the mains socket, check that:
• the mains power supply corresponds to the value indicated on the rating plate on the back of the appliance;
• the mains socket and electrical circuit are adequate for the appliance;
• the mains socket matches the plug. If this is not the case, have the plug replaced;
• the mains socket is adequately earthed. Failure to follow these important safety instructions
absolves the manufacturer of all liability.
The power cable must be replaced by a qualified professional only.
The instructions below will enable you to prepare your air conditioning unit for operation as effi­ciently as possible.
Before use, make sure the air intake and outlet grilles are unobstructed.
Keep air hoses as short and free of curves as possible to avoid constrictions.
GB-5751013500 27-07-2006 18:10 Pagina 16
Loading...
+ 7 hidden pages