Dell PowerEdge T630
用户手册
管制型号: E25S Series
管制类型: E25S001
August 2020
Rev. A06
目录
章 1: Dell PowerEdge T630 服务器概述 ..............................................................................................8
PowerEdge T630 服务器支持的配置................................................................................................................................ 8
前面板................................................................................................................................................................................... 10
2.5 英寸硬盘驱动器机箱 ..............................................................................................................................................10
3.5 英寸硬盘驱动器机箱 ..............................................................................................................................................12
LCD 面板 .........................................................................................................................................................................14
背面板................................................................................................................................................................................... 16
前面板上的诊断指示灯...................................................................................................................................................... 17
NIC 指示灯代码..............................................................................................................................................................18
电源装置指示灯代码.....................................................................................................................................................19
硬盘驱动器指示灯代码................................................................................................................................................ 21
找到系统的服务标签.......................................................................................................................................................... 21
章 2: 将该系统由塔式模式转换为机架模式.......................................................................................... 22
准备用于转换塔式模式为机架模式的系统 ................................................................................................................... 22
章 3: 说明文件资源......................................................................................................................... 26
章 4: 技术规格............................................................................................................................... 28
机箱尺寸.............................................................................................................................................................................. 29
机箱重量.............................................................................................................................................................................. 29
处理器规格.......................................................................................................................................................................... 30
PSU 规格..............................................................................................................................................................................30
系统电池规格 .....................................................................................................................................................................30
扩展总线规格...................................................................................................................................................................... 30
内存规格............................................................................................................................................................................... 31
驱动器规格........................................................................................................................................................................... 31
硬盘驱动器..................................................................................................................................................................... 31
光盘驱动器..................................................................................................................................................................... 31
端口和连接器规格..............................................................................................................................................................32
串行连接器.....................................................................................................................................................................32
内部双 SD 模块............................................................................................................................................................. 32
VGA 端口 ........................................................................................................................................................................32
USB 端口 ........................................................................................................................................................................ 32
NIC 端口 ......................................................................................................................................................................... 32
视频规格...............................................................................................................................................................................32
环境规格...............................................................................................................................................................................33
微粒和气体污染规格....................................................................................................................................................34
扩展操作温度................................................................................................................................................................ 34
扩展操作温度限制........................................................................................................................................................35
章 5: 初始系统设置和配置................................................................................................................36
设置系统.............................................................................................................................................................................. 36
目录
3
iDRAC 配置.......................................................................................................................................................................... 36
用于设置 iDRAC IP 地址的选项..................................................................................................................................36
登录到 iDRAC...................................................................................................................................................................... 37
安装操作系统的选项..........................................................................................................................................................37
下载驱动程序和固件..........................................................................................................................................................37
章 6: 预操作系统管理应用程序......................................................................................................... 38
用于管理预操作系统应用程序的选项.............................................................................................................................38
系统设置...............................................................................................................................................................................38
查看系统设置程序........................................................................................................................................................39
系统设置程序详细信息................................................................................................................................................39
System BIOS(系统 BIOS) ....................................................................................................................................... 39
iDRAC 设置公用程序 ....................................................................................................................................................60
Device Settings(设备设置 ) ........................................................................................................................................... 61
Dell Lifecycle Controller......................................................................................................................................................62
嵌入式系统管理............................................................................................................................................................ 62
引导管理器.......................................................................................................................................................................... 62
查看引导管理器............................................................................................................................................................ 62
引导管理器主菜单........................................................................................................................................................63
PXE 引导.............................................................................................................................................................................. 63
章 7: 安装和卸下系统组件................................................................................................................64
将系统从塔式转换为机架式的安全说明........................................................................................................................ 64
拆装系统内部组件之前..................................................................................................................................................... 65
拆装系统内部组件之后..................................................................................................................................................... 65
建议工具.............................................................................................................................................................................. 65
前挡板( 可选)..................................................................................................................................................................66
卸下可选的前挡板........................................................................................................................................................66
安装可选的前挡板........................................................................................................................................................ 67
系统支脚.............................................................................................................................................................................. 68
卸下系统支脚................................................................................................................................................................ 68
安装系统支脚................................................................................................................................................................ 69
脚轮 - 可选...........................................................................................................................................................................69
卸下脚轮.........................................................................................................................................................................69
安装脚轮.........................................................................................................................................................................70
系统护盖...............................................................................................................................................................................72
卸下系统护盖.................................................................................................................................................................72
安装系统护盖.................................................................................................................................................................73
系统内部组件...................................................................................................................................................................... 74
冷却导流罩.......................................................................................................................................................................... 75
卸下冷却导流罩............................................................................................................................................................ 75
安装冷却导流罩............................................................................................................................................................ 76
冷却风扇...............................................................................................................................................................................77
卸下冷却风扇.................................................................................................................................................................77
安装冷却风扇.................................................................................................................................................................78
冷却风扇部件( 可选)......................................................................................................................................................79
卸下可选冷却风扇部件 ...............................................................................................................................................79
安装可选冷却风扇部件................................................................................................................................................80
系统内存............................................................................................................................................................................... 81
4
目录
一般内存模块安装原则................................................................................................................................................82
模式特定原则................................................................................................................................................................ 82
内存配置示例................................................................................................................................................................ 83
卸下内存模块................................................................................................................................................................ 86
安装内存模块.................................................................................................................................................................87
可更换托架.......................................................................................................................................................................... 88
卸下可更换托架............................................................................................................................................................ 88
安装可更换托架............................................................................................................................................................ 89
硬盘驱动器.......................................................................................................................................................................... 90
卸下热插拔硬盘驱动器或固态驱动器....................................................................................................................... 91
安装热插拔硬盘............................................................................................................................................................ 92
卸下 2.5 英寸硬盘驱动器挡片....................................................................................................................................93
安装 2.5 英寸硬盘驱动器挡片....................................................................................................................................94
卸下 3.5 英寸硬盘驱动器挡片....................................................................................................................................94
安装 3.5 英寸硬盘驱动器挡片....................................................................................................................................95
将 2.5 英寸硬盘驱动器安装到 3.5 英寸硬盘驱动器适配器中.............................................................................. 96
从 3.5 英寸硬盘驱动器适配器中卸下 2.5 英寸硬盘驱动器...................................................................................97
将 3.5 英寸硬盘驱动器适配器安装到可热插拔硬盘驱动器托盘中..................................................................... 97
从 3.5 英寸可热插拔硬盘驱动器托盘卸下 3.5 英寸可热插拔硬盘驱动器适配器.............................................98
从硬盘托架中卸下硬盘或固态硬盘...........................................................................................................................99
将热插拔硬盘驱动器安装到热插拔硬盘驱动器托盘中........................................................................................100
光盘驱动器和磁带机........................................................................................................................................................100
卸下光盘驱动器或磁带机...........................................................................................................................................101
安装光盘驱动器或磁带机..........................................................................................................................................104
卸下细长型光盘驱动器挡片......................................................................................................................................105
安装细长型光盘驱动器挡片......................................................................................................................................106
内部 USB 存储盘( 可选)..............................................................................................................................................106
安装可选的内置 USB 闪存盘.................................................................................................................................... 107
扩展卡固定器.....................................................................................................................................................................108
卸下扩展卡固定器...................................................................................................................................................... 108
安装扩展卡固定器...................................................................................................................................................... 109
扩展卡..................................................................................................................................................................................110
扩展卡安装原则........................................................................................................................................................... 110
卸下扩展卡.....................................................................................................................................................................111
安装扩展卡....................................................................................................................................................................112
GPU 卡固定器( 可选 ) ....................................................................................................................................................113
卸下可选 GPU 卡固定器.............................................................................................................................................113
安装可选 GPU 卡固定器.............................................................................................................................................114
GPU 卡( 可选) ................................................................................................................................................................ 115
GPU 卡安装原则 .......................................................................................................................................................... 115
卸下可选 GPU 卡......................................................................................................................................................... 116
安装可选的 GPU 卡..................................................................................................................................................... 117
内部双 SD 模块( 可选)..................................................................................................................................................118
卸下可选的内置双 SD 模块........................................................................................................................................119
安装可选的内置双 SD 模块 ......................................................................................................................................120
内部 SD 卡..........................................................................................................................................................................120
卸下内部 SD 卡............................................................................................................................................................120
安装内部 SD 卡.............................................................................................................................................................121
处理器和散热器.................................................................................................................................................................122
目录
5
卸下散热器................................................................................................................................................................... 123
卸下处理器................................................................................................................................................................... 124
安装处理器...................................................................................................................................................................126
安装散热器...................................................................................................................................................................129
电源设备.............................................................................................................................................................................130
热备用功能....................................................................................................................................................................131
卸下交流电源设备....................................................................................................................................................... 131
安装交流电源设备.......................................................................................................................................................132
直流电源设备的布线说明.......................................................................................................................................... 133
卸下直流电源设备...................................................................................................................................................... 135
安装直流电源设备.......................................................................................................................................................136
卸下电源设备挡片.......................................................................................................................................................137
安装电源设备挡片.......................................................................................................................................................138
系统电池 ............................................................................................................................................................................139
更换系统电池...............................................................................................................................................................139
硬盘驱动器背板................................................................................................................................................................ 140
卸下硬盘驱动器背板................................................................................................................................................... 141
安装硬盘驱动器背板.................................................................................................................................................. 158
SD vFlash 卡( 可选 ) ...................................................................................................................................................... 164
装回可选的 SD vFlash 介质卡...................................................................................................................................165
控制面板部件.....................................................................................................................................................................165
卸下控制面板部件...................................................................................................................................................... 165
安装控制面板部件.......................................................................................................................................................167
系统板................................................................................................................................................................................. 168
卸下系统板...................................................................................................................................................................168
安装系统板................................................................................................................................................................... 170
可信平台模块.....................................................................................................................................................................172
安装可信平台模块.......................................................................................................................................................172
为 BitLocker 用户初始化 TPM...................................................................................................................................173
为 TXT 用户初始化 TPM............................................................................................................................................173
电源插入器板和配电板.................................................................................................................................................... 174
卸下电源插入器板.......................................................................................................................................................174
卸下配电板................................................................................................................................................................... 175
安装配电板................................................................................................................................................................... 176
安装电源插入器板.......................................................................................................................................................177
章 8: 使用系统诊断程序..................................................................................................................179
Dell 嵌入式系统诊断程序.................................................................................................................................................179
从引导管理器运行嵌入式系统诊断程序................................................................................................................. 179
从 Dell Lifecycle Controller 运行嵌入式系统诊断程序...........................................................................................179
系统诊断程序控制.......................................................................................................................................................179
章 9: 跳线和连接器 ....................................................................................................................... 181
系统板连接器..................................................................................................................................................................... 181
系统板跳线设置.................................................................................................................................................................183
禁用忘记的密码.................................................................................................................................................................183
章 10: 系统故障处理...................................................................................................................... 184
故障处理系统启动故障....................................................................................................................................................184
6
目录
外部连接故障处理............................................................................................................................................................ 184
视频子系统故障处理........................................................................................................................................................ 185
USB 设备故障处理............................................................................................................................................................185
串行输入和输出设备故障处理....................................................................................................................................... 186
NIC 故障处理..................................................................................................................................................................... 186
受潮系统故障处理.............................................................................................................................................................187
受损系统故障处理.............................................................................................................................................................187
系统电池故障处理............................................................................................................................................................ 188
电源装置故障处理............................................................................................................................................................ 189
电源问题故障处理...................................................................................................................................................... 189
电源设备故障...............................................................................................................................................................189
冷却问题故障处理............................................................................................................................................................ 189
冷却风扇故障处理............................................................................................................................................................ 190
系统内存故障处理............................................................................................................................................................ 190
内部 USB 闪存盘故障处理...............................................................................................................................................191
micro SD 卡故障处理........................................................................................................................................................192
光驱故障处理.....................................................................................................................................................................192
驱动器或 SSD 故障处理...................................................................................................................................................193
存储控制器故障处理........................................................................................................................................................ 194
扩展卡故障处理.................................................................................................................................................................194
处理器故障处理................................................................................................................................................................ 195
章 11: 获取帮助............................................................................................................................. 196
联系 Dell EMC....................................................................................................................................................................196
说明文件反馈.....................................................................................................................................................................196
通过使用 QRL 访问系统信息..........................................................................................................................................196
PowerEdge T630 的快速资源定位器 (QRL)...........................................................................................................197
UEFI iSCSI 设置 ..................................................................................................................................................................197
目录
7
Dell PowerEdge T630 服务器概述
Dell PowerEdge T630 机架式塔式服务器支持:
● Intel Xeon E5-2600 v4 处理器
● 24 个 DIMM
● 八个 3.5 英寸硬盘驱动器
● 四个 Dell PowerEdge Express Flash 设备
● 三十二个 2.5 英寸硬盘驱动器
注: T630 系统仅支持可热插拔的内部硬盘驱动器。
主题:
• PowerEdge T630 服务器支持的配置
• 前面板
• 背面板
• 前面板上的诊断指示灯
• 找到系统的服务标签
1
PowerEdge T630 服务器支持的配置
Dell PowerEdge T630 系统支持以下配置:
8 Dell PowerEdge T630 服务器概述
图 1: PowerEdge T630 支持的配置
Dell PowerEdge T630 服务器概述 9
前面板
2.5 英寸硬盘驱动器机箱
图 2: 前面板 - 2.5 英寸硬盘驱动器机箱
SD vFlash 卡插槽 2.
1.
3. NMI 按钮 4.
5. LCD 菜单按钮 6.
7. LCD 面板 8. iDRAC Direct 端口
9. VGA 连接器 10. USB 连接器
光盘驱动器或磁带驱动器托架
11.
10 Dell PowerEdge T630 服务器概述
电源按钮
系统识别按钮
信息标签
物理驱动器
12.
表. 1: 前面板按钮和连接器说明
项目 按钮或连接器 图标 说明
1 SD vFlash 卡插槽 用此项插入 vFlash 介质卡。 vFlash 介质卡属于 SD 卡, 可扩展
iDRAC 企业卡的功能。
2
通电指示灯、电源按钮 通电指示灯在系统开机时亮起。电源按钮控制到系统的电源设备
输出。
注 : 对于兼容 ACPI 的操作系统, 使用电源按钮关闭系统可以
在系统电源关闭前执行正常有序的关机操作。
3 NMI 按钮
4
5 LCD 菜单按钮 使用此按钮导航控制面板 LCD 菜单。
6
7 LCD 面板
系统识别按钮 前面板和背面板上的识别按钮可用于查找机架中的特定系统。当
信息标签
此按钮用于在运行某些操作系统时对软件和设备驱动程序错误进
行故障排除。可以用回形针的末端按压此按钮。
注 : 只有当合格的支持人员或操作系统说明文件指示可以使
用此按钮时才能使用它。
按下其中一个按钮时, 系统前面板上的 LCD 面板和后面板上的
系统状态指示灯将闪烁, 直至再次按下其中一个按钮为止。
按下可切换系统 ID 的开或关。
如果系统在 POST 过程中停止响应, 按住系统 ID 按钮五秒以
上, 可进入 BIOS 进程模式。
要重设 iDRAC( 如果未在<F2> iDRAC 设置中禁用), 请按住该
按钮超过 15 秒。
包含服务标签、NIC 、MAC 地址等系统信息供参考。信息标签是
滑出式标签面板。
显示系统 ID 、状态信息和系统错误信息。系统正常运行期间,
LCD 闪烁蓝色。系统需要予以留意时, LCD 灯变为琥珀色, 并显
示错误代码和相应的说明性文本。
注 : 如果系统已连接至电源并检测到错误, 则无论系统是否
打开,LCD 都将呈琥珀色闪烁。
8 USB 管理端口 /iDRAC 直接端口 USB 管理端口可以用作常规的 USB 端口, 或者提供对 iDRAC
Direct 功能的访问。有关更多信息, 请参阅 Dell.com/
idracmanuals 上的 Integrated Dell Remote Access Controller
User's Guide( Integrated Dell Remote Access Controller 用户指
南) 。
该端口符合 USB 2.0 标准
9 VGA 连接器 允许您将 VGA 显示屏连接到系统。
注 : VGA 连接器只能在系统的机架模式配置中使用。有关将
您的系统从塔式转换为机架模式的信息, 请参阅“准备用于
转换塔式模式为机架模式的系统”部分。
10 USB 连接器 用此项将 USB 设备连接到系统。此端口兼容 USB 3.0。
11
12
相关概念
准备用于转换塔式模式为机架模式的系统 页面上的 22
光盘驱动器或磁带机托架 用此项安装光盘驱动器或磁带驱动器。有关支持的光盘驱动器和
磁带驱动器的更多信息, 请参阅“光盘驱动器”和“磁带驱动
器”部分。
物理驱动器
最多三十二个 2.5 英寸硬盘驱动器
Dell PowerEdge T630 服务器概述 11
3.5 英寸硬盘驱动器机箱
。
图 3: 前面板 — 3.5 英寸硬盘驱动器加四个 PCIe SSD 机箱
SD vFlash 卡插槽 2.
1.
3. NMI 按钮 4.
5. LCD 菜单按钮 6.
7. LCD 面板 8. iDRAC Direct 端口
9. VGA 连接器 10. USB 连接器
光盘驱动器或磁带驱动器托架
11.
13. PCIe SSD 14. 3.5 英寸硬盘驱动器
12 Dell PowerEdge T630 服务器概述
电源按钮
系统识别按钮
信息标签
可更换托架
12.
表. 2: 前面板按钮和连接器说明
项目 按钮或连接器 图标 说明
1 SD vFlash 卡插槽 用此项插入 vFlash 介质卡。 vFlash 介质卡属于 SD 卡, 可扩展
iDRAC 企业卡的功能。
2
通电指示灯、电源按钮 通电指示灯在系统开机时亮起。电源按钮控制到系统的电源设备
输出。
注 : 对于兼容 ACPI 的操作系统, 使用电源按钮关闭系统可以
在系统电源关闭前执行正常有序的关机操作。
3 NMI 按钮
4
5 LCD 菜单按钮 使用此按钮导航控制面板 LCD 菜单。
6
7 LCD 面板
系统识别按钮 前面板和背面板上的识别按钮可用于查找机架中的特定系统。当
信息标签
此按钮用于在运行某些操作系统时对软件和设备驱动程序错误进
行故障排除。可以用回形针的末端按压此按钮。
注 : 只有当合格的支持人员或操作系统说明文件指示可以使
用此按钮时才能使用它。
按下其中一个按钮时, 系统前面板上的 LCD 面板和后面板上的
系统状态指示灯将闪烁, 直至再次按下其中一个按钮为止。
按下可切换系统 ID 的开或关。
如果系统在 POST 过程中停止响应, 按住系统 ID 按钮五秒以
上, 可进入 BIOS 进程模式。
要重设 iDRAC( 如果未在<F2> iDRAC 设置中禁用), 请按住该
按钮超过 15 秒。
包含服务标签、NIC 、MAC 地址等系统信息供参考。信息标签是
滑出式标签面板。
显示系统 ID 、状态信息和系统错误信息。系统正常运行期间,
LCD 闪烁蓝色。系统需要予以留意时, LCD 灯变为琥珀色, 并显
示错误代码和相应的说明性文本。
注 : 如果系统已连接至电源并检测到错误, 则无论系统是否
打开,LCD 都将呈琥珀色闪烁。
8 USB 管理端口 /iDRAC 直接端口 USB 管理端口可以用作常规的 USB 端口, 或者提供对 iDRAC
Direct 功能的访问。有关更多信息, 请参阅 Dell.com/
idracmanuals 上的 Integrated Dell Remote Access Controller
User's Guide( Integrated Dell Remote Access Controller 用户指
南) 。
该端口符合 USB 2.0 标准
9 VGA 连接器 允许您将 VGA 显示屏连接到系统。
注 : VGA 连接器只能在系统的机架模式配置中使用。有关将
您的系统从塔式转换为机架模式的信息, 请参阅“准备用于
转换塔式模式为机架模式的系统”部分。
10 USB 连接器 用此项将 USB 设备连接到系统。此端口兼容 USB 3.0。
11
12
13 PCIe SSD 最多四个 PCIe SSD
14
相关概念
准备用于转换塔式模式为机架模式的系统 页面上的 22
光盘驱动器或磁带机托架 用此项安装光盘驱动器或磁带驱动器。有关支持的光盘驱动器和
磁带驱动器的更多信息, 请参阅“光盘驱动器”和“磁带驱动
器”部分。
可更换托架
物理驱动器
支持最多安装四个 PCIe SSD
多达 8 个 3.5 英寸硬盘驱动器
Dell PowerEdge T630 服务器概述 13
LCD 面板
系统的 LCD 面板提供了系统信息、状态和错误消息, 以指示系统是否正确运行或者系统是否需要引起注意。有关错误消息的更多信
息, 请参阅 Dell.com/openmanagemanuals >OpenManage software( OpenManage 软件) 的 Dell Event and Error Messages
Reference Guide (Dell 事件和错误消息参考指南) 。
● 系统正常运行期间,LCD 背景光呈蓝色亮起。
● 系统需要予以注意时,LCD 呈琥珀色亮起, 并显示错误代码, 并且后面跟随有描述性文本。
注 : 如果系统已连接至电源并且检测到错误, 则无论系统是否开启 , LCD 都呈琥珀色亮起。
● LCD 背景光将在系统处于待机模式时关闭, 并可通过按 LCD 面板上的选择、向左或向右按钮来打开。
● 如果通过 iDRAC 公用程序、LCD 面板或其他工具关闭了 LCD 消息显示,LCD 背景光将处于不亮状态。
图 4: LCD 面板功能部件
表. 3: LCD 面板功能部件
项目 按钮 说明
1
2
3
左 使光标向后移动一步。
选择 选择由光标高亮度显示的菜单项。
右 使光标向前移动一步。
在信息滚动过程中:
● 按住电源按钮可提高滚动速度。
● 松开按钮可停止。
注 : 当松开按钮时, 显示屏将停止滚动。在处于不活动状态 45 秒后, 显示屏
将开始滚动。
查看主页屏幕
Home (主页) 屏幕显示有关系统的用户可配置信息。在系统正常运行过程中没有状态消息或错误时, 即会显示此屏幕。当系统关闭
并且没有错误时,LCD 将在不活动状态五分钟后进入待机模式。按下 LCD 上的任何)按钮将其打开。
步骤
1. 按三个导航按钮( 选择、向左或向右) 中的任意一个, 即可查看 Home( 主页) 屏幕。
2. 要从其他菜单导航至主屏幕, 请完成以下步骤:
a. 按住导航按钮直到显示向上箭头
。
b. 使用向上箭头 导航到
c. 选择主屏幕 图标。
d. 从主屏幕 中按 Select( 选择) 按钮, 进入主菜单。
设置菜单
注: 在 Setup(设置 )菜单中选择一个选项后 ,必须确认该选项 ,然后才能进行下一项操作。
14 Dell PowerEdge T630 服务器概述
选项 说明
iDRAC 选择 DHCP 或 Static IP(静态 IP )以配置网络模式。如果选择了 Static IP(静态 IP ),则可用字段为 IP、
Subnet (Sub)(子网 [Sub] )和 Gateway (Gtw)(网关 [Gtw] )。选择 Setup DNS(设置 DNS )以启用
DNS 并查看域地址。有两个独立的 DNS 条目可用。
Set error (设置错 误 ) 选择 SEL , 以与 SEL 中的 IPMI 说明匹配的格式查看 LCD 错误消息。这样您能够将 LCD 消息与 SEL 条目匹
配。
选择 Simple( 简单), 在简化的、用户友好的说明中查看 LCD 错误消息。有关错误消息的更多信息, 请参阅
Dell.com/openmanagemanuals > OpenManage software 上的 Dell Event and Error Messages Reference
Guide(Dell 事件和错误消息参考指南 )。
Set home (设置主
屏幕)
相关参考资料
视图菜单 页面上的 15
选择要在主 屏幕上显示的默认信息。请参阅 View( 视图) 菜单部分以查看可以设置为主 屏幕上默认设置的选
项和选项项目。
视图菜单
注: 在“视图”菜单中选择一个选项后, 必须确认该选项, 然后才能进行下一项操作。
选项 说明
iDRAC IP 显示 iDRAC8 的 IPv4 或 IPv6 地址。地址包括 DNS(主要和 次要 )、网关 、 IP 及子网( IPv6 没有子网) 。
MAC 显示 iDRAC、 iSCSI 或网络 设备的 MAC 地址。
名称
编号 显示系统的 资产标签或 服务标签。
功率
温度
显示系统的 Host( 主机) 名称、Model( 型号) 或 User String( 用户字符串) 。
显示系统的电源输出( 以 BTU/小时或瓦特为单位) 。可以在 Setup( 设置) 菜单的 Set home( 设置主屏
幕) 中配置显示格式。
显示系统的温度( 以摄氏或华氏为单位) 。可以在 Setup( 设置) 菜单的 Set home( 设置主屏幕) 中配置显
示格式。
Dell PowerEdge T630 服务器概述 15
背面板
图 5: 背面板功能部件
1. PCIe 扩充卡插槽( 3 个)( 处理器 1 ) 2.
系统识别连接器
3.
5. iDRAC Enterprise 端口 6. 电源设备 (PSU1)
7. USB 端口 (6) 8.
串行连接器
9.
11. 全高 PCIe 扩展卡插槽( 处理器 2)
以太网连接器
系统识别按钮
4.
视频连接器
10. 电源设备 (PSU2)
表. 4: 背部面板指示灯、按钮或连接器说明
项目 指示灯、按钮或连接器 图标 说明
1 PCIe 扩充卡插槽( 3 个)( 处
理器 1)
2
3
4
以太网连接器
系统识别连接器 它通过可选电缆固定臂连接可选系统状态指示灯部件。
系统识别按钮 前面板和背面板上的识别按钮可用于查找机架中的特定系统。当
您最多可连接两个 PCI Express 扩展卡以及一个 PERC 卡。
两个集成的 10/100/1000 Mbps NIC 连接器。
按下其中一个按钮时, 系统前面板上的 LCD 面板和后面板上的
系统状态指示灯将闪烁, 直至再次按下其中一个按钮为止。
按下可切换系统 ID 的开和关。
16 Dell PowerEdge T630 服务器概述
表. 4: 背部面板指示灯、按钮或连接器说明 ( 续)
项目 指示灯、按钮或连接器 图标 说明
如果系统在 POST 过程中停止响应, 按住系统 ID 按钮五秒以
上, 可进入 BIOS Progress( BIOS 进程) 模式。
要重设 iDRAC( 如果在 F2 iDRAC 设置中未禁用), 则按住 15 秒
以上。
5 iDRAC Enterprise 端口
6 电源设备 (PSU1)
7 USB 端口 (6) 您可将 USB 设备连接到系统。四个 USB 2.0 兼容端口和两个
8
9
10 电源设备 (PSU2)
11 全高 PCIe 扩展卡插槽( 处理器
视频连接器
串行连接器 您可将串行设备连接到系统。
2)
专用管理端口。
注 : 仅在系统上安装了 iDRAC Enterprise 许可证时才可使用此
端口。
交流
或
直流
USB 3.0 兼容端口。
您可以将 VGA 显示屏连接到系统。
交流
或
直流
连接最多三四全高 PCI Express 扩充卡。
495 W、 750 W、 1100 W 或 1600 W
1100 W
495 W、 750 W、 1100 W 或 1600 W
1100 W
前面板上的诊断指示灯
注: 当系统关闭时诊断指示灯不亮。要启动系统, 将系统连接至正常工作的电源并按下电源按钮。
表. 5: 诊断指示灯
图标 说明 状态 纠正措施
运行状况指示灯
硬盘指示灯
如果系统运行状况良好, 指示灯会
持续亮起蓝色。
指示灯闪烁琥珀色:
● 当系统处于开启状态时。
● 当系统处于待机状态时。
● 如果存在任何错误条件。如果存
在任何错误条件。例如, 风扇、
PSU 或硬盘发生故障。
如果存在硬盘错误, 指示灯呈琥珀
色闪烁。
无需采取措施。
请参阅 System Event Log( 系统事件日志) 或系统消息
了解特定问题。有关错误消息的更多信息, 请参阅 Dell
Event and Error Messages Reference Guide(Dell
和错误消息参考指南)
openmanagemanuals > OpenManage software 。
由于内存配置无效,POST 过程中断而不具有任何视频
输出。请参阅“获得帮助”部分。请参阅“获得帮助”
部分。
请参阅“系统事件日志”确定出现错误的硬盘。运行相
应的联机诊断检测程序。重新启动系统并运行嵌入式诊
断程序 (ePSA) 。如果硬盘是在 RAID 阵列中配置的, 则
重新启动系统并进入主机适配器配置实用程序。
事件
, 网址 : Dell.com/
Dell PowerEdge T630 服务器概述 17
表. 5: 诊断指示灯 ( 续)
图标 说明 状态 纠正措施
电子指示灯
温度指示灯
内存指示灯
相关参考资料
获取帮助 页面上的 196
如果系统遇到电气错误( 例如, 电
压超出范围或电源装置或稳压器出
现故障), 指示灯将闪烁琥珀色。
如果系统遇到散热错误( 例如, 环
境温度超出范围或风扇故障), 指
示灯将闪烁琥珀色。
如果发生内存错误, 指示灯将呈琥
珀色闪烁。
请参阅 System Event Log( 系统事件日志) 或系统消息
了解特定问题。如果问题出自电源装置, 则检查电源装
置上的 LED 。重新拔插 PSU 。如果问题仍然存在, 请
参阅“获得帮助”部分。
确保不存在以下任何情况:
● 冷却风扇已卸下或出现故障。
● 系统护盖、冷却导流罩、EMI 填充面板、内存模块
挡片或后填料支架已卸。
● 环境温度太高。
● 外部通风受阻。
请参阅“获得帮助”部分。
请参阅系统事件日志或系统消息, 查看故障内存的位
置。重新安置内存模块如果问题仍然存在, 请参阅“获
得帮助”部分。
NIC 指示灯代码
后面板上的 NIC 具有指示灯, 可提供关于网络活动和链路状态的信息。活动 LED 指示 NIC 当前是否已连接。链路 LED 指示连接网络
的速度。
图 6: NIC 指示灯代码
1. 链路指示灯
2. 活动指示灯
表. 6: NIC 指示灯
惯例 状态 状态
A
B
C
D
链路和活动指示灯不亮。
链路指示灯呈绿色亮起。
链路指示灯呈琥珀色
活动指示灯闪烁。绿色 正在发送或接收网络数据。
NIC 未连接至网络。
NIC 以其最高端口速度( 1 Gbps 或 10 Gbps)连接到有效
的网络。
NIC 以低于其最高端口速度的速度连接到有效的网络。
18 Dell PowerEdge T630 服务器概述
电源装置指示灯代码
交流电源装置 (PSU) 有一个半透明照明手柄, 可作为指示灯使用。DC PSU 有一个 LED 灯, 也可以用作指示灯。指示灯可以指示电
源是否存在或电源是否发生故障。
图 7: AC PSU 状态指示灯
1. AC PSU 状态指示灯 /手柄
表. 7: AC PSU 状态指示灯
惯例 电源指示灯显示方式 情况
A
B
C 呈绿色闪烁, 然后熄 灭在热添加 PSU 时,PSU 手柄以 4 Hz 频率闪烁绿光, 然后熄灭。这表示 PSU 在效率、
D
绿色
绿色闪烁
呈琥珀色闪烁
有效的电源已连接到 PSU, PSU 正常运行。
PSU 的固件进行更新时, PSU 手柄呈绿色闪烁。
功能组、运行状况和支持的电压方面不匹配。
注: 请确保这两个 PSU 的容量相同。
小心: 对于交流 PSU,只能使用背面贴有扩展电源性能 (EPP) 标签的 PSU。
注: 混用前几代戴尔 PowerEdge 服务器的 PSU 可能导致 PSU 不匹配或系统无法开
机。
表示 PSU 出现问题。
小心: 在纠正 PSU 不匹配情况时, 请仅更换指示灯闪烁的 PSU。更换另外的 PSU
以构成匹配的 PSU 对将导致错误状况, 并且系统会出现意外关机。要从高输出配
置更改为低输出配置或反之, 必须关闭系统电源。
小心: AC PSU 支持 220 V 和 110 V 输入电压, Titanium PSU(仅支持 220 V)除
外。在两个相同的电源装置接收不同的输入电压时, 它们可以输出不同的功率并触
发不匹配情况。
小心: 如果使用两个 PSU,二者必须为相同类型且具有相同的最大输出功率。
小心: 不支持交流 PSU 和直流 PSU 混用, 否则会触发不匹配的情况。
E
不亮 未连接电源。
Dell PowerEdge T630 服务器概述 19
图 8: DC PSU 状态指示灯
1. DC PSU 状态指示灯
表. 8: DC PSU 状态指示灯
惯例 电源指示灯显示方式 情况
A
B
C
绿色
绿色闪烁
呈琥珀色闪烁
有效的电源已连接到 PSU, PSU 正常运行。
热添加 PSU 时,PSU 指示灯呈绿色闪烁。这表示 PSU 在效率、功能组、运行状况和
支持的电压方面不匹配。请确保这两个 PSU 的容量相同。
表示 PSU 出现问题。
小心 : 在纠正 PSU 不匹配情况时, 请仅更换指示灯闪烁的 PSU 。更换另外的
PSU 以构成匹配的 PSU 对将导致错误状况, 并且系统会出现意外关机。要从高
输出配置更改为低输出配置或反之, 必须关闭系统电源。
小心: AC PSU 支持 220 V 和 110 V 输入电压, Titanium PSU(仅支持 220 V)
除外。在两个相同的 PSU 接收不同的输入电压时, 它们可以输出不同的功率并
触发不匹配情况。
小心: 如果使用两个 PSU,二者必须为相同类型且具有相同的最大输出功率。
小心: 不支持 AC PSU 和 DC PSU 混用, 否则会触发不匹配的情况。
D
20 Dell PowerEdge T630 服务器概述
不亮 未连接电源。
硬盘驱动器指示灯代码
每个硬盘驱动器托盘都有一个活动指示灯和一个状态指示灯。指示灯提供硬盘驱动器当前状态的相关信息。活动 LED 指示硬盘驱动
器当前是否正在使用。状态 LED 指示硬盘驱动器的电源状况。
图 9: 硬盘驱动器指示灯
1. 硬盘驱动器活动指示灯
2. 硬盘驱动器状态指示灯
3. 硬盘驱动器
注: 如果硬盘驱动器处于高级主机控制器接口 (AHCI) 模式, 状态指示灯( 右侧) 不会亮起。
表. 9: 硬盘驱动器指示灯代码
驱动器状态指示灯显示方式 状态
每秒呈绿色闪烁两次 识别驱动器或准备卸下。
Off (关)
闪烁绿色、琥珀色, 然后熄灭
每秒闪烁琥珀色光四次 驱动器故障
缓慢闪烁绿光 正在重建驱动器
呈绿色稳定亮起 驱动器联机
呈绿色闪烁三秒, 呈琥珀色闪烁三秒, 然后在六秒钟后熄灭
准备插入或卸下驱动器。
注 : 在系统开机之后所有硬盘驱动器都初始化之前, 驱动器状态
指示灯会一直保持熄灭。此时, 驱动器不能进行插入或卸下操
作。
预测的驱动器故障
重建已停止
找到系统的服务标签
您的系统由唯一的快速服务代码和服务标签号码来标识。通过拉出信息标签, 可找到位于系统正面的快速服务代码和服务标签。另
外, 该信息也可能位于系统机箱上的不干胶标签上。Dell 使用此信息将支持电话转接到相应的人员。
Dell PowerEdge T630 服务器概述 21
将该系统由塔式模式转换为机架模式
您可以将系统从塔式模式转换为机架模式。
要将系统从塔式模式转换为机架模式时, 您需要将塔式转换到机架的转换套件, 该套件包含以下项目:
● 每个机架吊耳( 左边和右边) 需要三颗螺钉
● VGA 模块
● 机架滑盖
● 聚酯盖
● 一对滑轨( 可选)
主题:
• 准备用于转换塔式模式为机架模式的系统
准备用于转换塔式模式为机架模式的系统
前提条件
1. 请按照“安全说明”部分所列的安全原则进行操作。
2. 准备好 2 号梅花槽螺丝刀。
3. 关闭系统, 包括所有已连接的外围设备, 并断开系统与电源插座和外围设备的连接。
4. 将系统放置在平稳的表面上。
5. 如已安装系统支脚或脚轮, 请将其卸下。有关更多信息, 请参阅卸下系统支脚或卸下脚轮。
6. 卸下系统护盖。
2
步骤
1. 卸下系统顶盖。有关更多信息, 请参阅“卸下系统顶盖”部分。
2. 卸下控制面板部件。有关更多信息, 请参阅“卸下控制面板部件”部分。
3. 安装机架滑盖, 请执行以下步骤:
a. 在系统的侧护盖和机箱之间滑动机架滑盖。
b. 将机架滑盖滑向系统背面, 直至机架侧盖锁上的卡舌与机箱上伸出的卡舌锁定。
22
将该系统由塔式模式转换为机架模式
图 10: 安装机架滑盖。
a. 机架滑盖
b. 系统机箱
图 11: 卸下机架滑盖
a. 机架滑盖
b. 系统机箱
4. 安装控制面板部件。有关更多信息, 请参阅“安装控制面板部件”。
5. 将聚酯盖安装到机箱的开口, 塔式模式下安装系统后支脚。请参阅下图了解详细信息。
将该系统由塔式模式转换为机架模式
23
图 12: 安装聚酯盖
a. 在机箱上做标记
b. 聚酯盖
6. 安装系统护盖。
7. 安装机架吊耳, 请执行以下步骤:
a. 将机架吊耳上的三个螺孔与系统顶部和底部的螺孔对齐。
b. 使用 Phillips #2 螺丝刀安装三颗螺钉。
24
将该系统由塔式模式转换为机架模式
图 13: 卸下机架吊耳
a. 螺钉(6 颗)
b. 机架吊耳(2 个)
c. 机架模式下的系统
8. 将系统安装到机架中。有关更多信息, 请参阅系统随附的 Rack Installation Guide( 机架安装指南) 。
相关参考资料
将系统从塔式转换为机架式的安全说明 页面上的 64
相关任务
卸下系统护盖 页面上的 72
卸下控制面板部件 页面上的 165
将该系统由塔式模式转换为机架模式
25
本节介绍了有关系统说明文件资源的信息。
要查看文档资源表中列出的说明文件表:
● 从 Dell EMC 支持站点:
1. 单击表中“位置”列下提供的文档链接。
2. 单击所需的产品或产品版本。
注: 要找到产品名称和型号, 请参阅您的系统正面。
3. 在“产品支持”页面上, 单击 手册和文档 。
● 使用搜索引擎:
○ 在搜索框中键入文档的名称和版本。
表. 10: 系统其他说明文件资源
任务 说明文件 位置
3
说明文件资源
设置系统
配置系统
有关将系统安装和固定到机架中的
更多信息, 请参阅机架解决方案随
附的 Rail Installation Guide 。
有关设置系统的信息, 请参阅系统
随附的 Getting Started Guide 说明文
件。
有关 iDRAC 的功能、配置和登录
iDRAC ,以及远程管理系统的信息,
请参阅 Integrated Dell Remote
Access Controller User's Guide 。
要了解 Remote Access Controller
Admin (RACADM) 子命令和支持的
RACADM 界面的信息, 请参阅
RACADM CLI Guide for iDRAC。
有关 Redfish 及其协议、支持的架构
以及 iDRAC 中实施的 Redfish 的信
息, 请参阅 Redfish API Guide 。
有关 iDRAC 属性数据库组和对象说
明的信息, 请参阅 Attribute Registry
Guide 。
有关较早版本的 iDRAC 说明文件的
信息, 请参阅 iDRAC 文档。
要识别您的系统上可用的 iDRAC 版
本, 在 iDRAC web 界面, 单击 ? >
关于 。
www.dell.com/poweredgemanuals
www.dell.com/poweredgemanuals
www.dell.com/idracmanuals
有关安装该操作系统的信息, 请参
阅操作系统说明文件。
有关更新驱动程序和固件的信息,
请参阅本说明文件中的“下载固件
和驱动程序的方法”部分。
管理系统 有关戴尔提供的系统管理软件的信
息, 请参阅 Dell OpenManage
26
说明文件资源
www.dell.com/
operatingsystemmanuals
www.dell.com/support/drivers
www.dell.com/poweredgemanuals
表. 10: 系统其他说明文件资源 ( 续)
任务 说明文件 位置
Systems Management Overview
Guide。
有关安装、使用 OpenManage 以及
进行故障处理的信息, 请参阅 Dell
OpenManage Server Administrator
User’ s Guide。
有关安装、使用 Dell OpenManage
Essentials 以及进行故障处理的信
息 , 请参阅 Dell OpenManage
Essentials User’ s Guide。
有关安装、使用 Dell OpenManage
Enterprise 以及进行故障处理的信
息 , 请参阅 Dell OpenManage
Essentials User’ s Guide。
有关安装和使用 Dell SupportAssist
的信息, 请参阅 Dell EMC
SupportAssist Enterprise User’ s
Guide。
有关合作伙伴计划企业系统管理的
信息, 请参阅 OpenManage
Connections Enterprise Systems
Management 说明文件。
使用戴尔 PowerEdge RAID 控制器 要了解戴尔 PowerEdge RAID 控制器
www.dell.com/openmanagemanuals
> OpenManage Server Administrator
www.dell.com/openmanagemanuals
> OpenManage Essentials
www.dell.com/openmanagemanuals
> OpenManage Enterprise
https://www.dell.com/
serviceabilitytools
www.dell.com/openmanagemanuals
(PERC)、软件 RAID 控制器或 BOSS
卡的功能以及部署卡的信息, 请参
阅存储控制器说明文件。
www.dell.com/
storagecontrollermanuals
了解事件和错误消息
系统故障处理
有关系统固件和代理( 用于监控系
统组件) 生成的事件和错误消息的
信息, 请参阅“查找错误代码”。
有关发现和排除 PowerEdge 服务器
问题的信息, 请参阅 Server
Troubleshooting Guide。
www.dell.com/qrl
www.dell.com/poweredgemanuals
说明文件资源
27
本节概述了系统的技术规格和环境规格。
主题:
• 机箱尺寸
• 机箱重量
• 处理器规格
• PSU 规格
• 系统电池规格
• 扩展总线规格
• 内存规格
• 驱动器规格
• 端口和连接器规格
• 视频规格
• 环境规格
4
技术规格
28
技术规格
机箱尺寸
图 14: 详细介绍 Dell PowerEdge T630 系统的尺寸
表. 11: Dell PowerEdge T630 系统的尺寸
系统
PowerEdge
T630
Xa Xb Ya Yb Yc Za(含挡 板) Za(不含
304.5 217.9 434.5 443.5 471.5 15.9 0.0
机箱重量
表. 12: 机箱重量
PowerEdge T630
3.5 英寸硬盘驱动器机箱
最大重量
49.65 kg
挡板)
Zb* Zc
659.9
692.8
技术规格
29
表 . 12: 机箱重量 ( 续 )
PowerEdge T630
2.5 英寸硬盘驱动器机箱
最大重量
42.36 kg
处理器规格
PowerEdge T630 系统最多可支持两个 Intel Xeon E5-2600 v4 或 Xeon E5-2600 v3 产品系列处理器。
PSU 规格
PowerEdge T630 系统支持最多两个交流或直流冗余电源装置 (PSU)。
表 . 13: PSU 规格
PSU
495 W 交流
750 W 交流
1100 W 交流
1600 W 交流
分类
白金级
白金级
钛金级
白金级
白金级
散热( 最大)
1908 BTU /小时 50/60 Hz 100–240 V 交流, 自动调节范围
2891 BTU /小时
2843 BTU /小时 200–240 V 交流, 自动调节范围
4100 BTU /小时 100–240 V 交流, 自动调节范围
6000 BTU /小时 100–240 V 交流, 自动调节范围
频率 电压
1100 W 直流( 仅限中
国)
注: 散热量是使用 PSU 的额定功率来计算的。
注: 此系统也可连接相间电压不超过 230 V 的 IT 电源系统。
注: 额定功率是 1600 W 和更高的 PSU 需要高压线路电压 (200–240 V) 以提供额定容量。
不适用
4416 BTU / 小时 –(48 –60) V 直流
系统电池规格
PowerEdge T630 系统支持的系统电池为 CR 2032 3.0-V 纽扣式锂电池。
扩展总线规格
PowerEdge T630 系统支持 PCI Express (PCIe) 第 3 代和第 2 代扩展卡。下表说明了支持的扩展卡:
表 . 14: 支持的 PCI Express 第 3 代扩展卡
PCIe 插槽
1 (Gen3) 处理器 1
2 (Gen2)
处理器连接 高度 长度 链路宽度 插槽宽度
标准高度 全长
平台控制器集线器 标准高度
全长* x4 x8
x16 x16
3 (Gen3) 处理器 1
4 (Gen3) 处理器 2
5 (Gen2) 处理器 2
6 (Gen3) 处理器 2
30
技术规格
标准高度 全长
标准高度 半长
标准高度
标准高度 全长
全长* x4 x8
x16 x16
x8 x8