Dell PowerEdge T330
用户手册
管制型号: E35S Series
管制类型: E35S001
August 2020
Rev. A10
目录
章 1: 关于 Dell PowerEdge T330 系统................................................................................................. 8
PowerEdge T330 系统支持的配置.....................................................................................................................................9
前面板................................................................................................................................................................................... 10
前面板功能部件和指示灯——塔式模式...................................................................................................................10
前面板功能部件和指示灯——机架模式...................................................................................................................13
LCD 面板.........................................................................................................................................................................14
背面板功能部件...................................................................................................................................................................17
背面板功能部件和指示灯............................................................................................................................................ 17
诊断指示灯........................................................................................................................................................................... 18
前面板上的诊断指示灯................................................................................................................................................ 18
硬盘驱动器指示灯代码................................................................................................................................................ 19
NIC 指示灯代码.............................................................................................................................................................20
内部双 SD 模块指示灯代码........................................................................................................................................ 20
冗余电源设备单元的指示灯代码................................................................................................................................21
非冗余有线电源装置指示灯代码...............................................................................................................................22
找到系统的服务标签..........................................................................................................................................................22
章 2: 说明文件资源......................................................................................................................... 23
章 3: 技术规格............................................................................................................................... 25
机箱尺寸.............................................................................................................................................................................. 25
机箱重量.............................................................................................................................................................................. 26
处理器规格.......................................................................................................................................................................... 26
扩展总线规格...................................................................................................................................................................... 26
内存规格.............................................................................................................................................................................. 26
电源规格...............................................................................................................................................................................27
存储控制器规格.................................................................................................................................................................. 27
驱动器规格...........................................................................................................................................................................27
硬盘驱动器.....................................................................................................................................................................27
光盘驱动器.....................................................................................................................................................................27
磁带驱动器.....................................................................................................................................................................27
端口和连接器规格..............................................................................................................................................................28
USB 端口 ........................................................................................................................................................................28
NIC 端口 ......................................................................................................................................................................... 28
iDRAC8............................................................................................................................................................................28
串行连接器 .....................................................................................................................................................................28
VGA 端口 ........................................................................................................................................................................28
SD vFlash........................................................................................................................................................................28
内部双 SD 模块............................................................................................................................................................. 28
视频规格...............................................................................................................................................................................28
扩展操作温度...................................................................................................................................................................... 29
环境规格.............................................................................................................................................................................. 29
章 4: 初始系统设置和配置................................................................................................................ 31
目录
3
设置系统 ............................................................................................................................................................................... 31
iDRAC 配置 ........................................................................................................................................................................... 31
用于设置 iDRAC IP 地址的选项.................................................................................................................................. 31
安装操作系统的选项..........................................................................................................................................................32
下载固件和驱动程序的方法....................................................................................................................................... 32
章 5: 预操作系统管理应用程序......................................................................................................... 34
导航键...................................................................................................................................................................................34
系统设置...............................................................................................................................................................................34
进入系统设置................................................................................................................................................................ 35
系统设置程序详细信息................................................................................................................................................35
系统 BIOS 设置详细信息.............................................................................................................................................35
System Information (系统信息) 的详细信息 ......................................................................................................... 36
内存设置详细信息........................................................................................................................................................36
处理器设置详细信息....................................................................................................................................................36
SATA Settings ( SATA 设置) 详细信息 ....................................................................................................................37
引导设置详细信息........................................................................................................................................................39
Network Settings (网络设置) 屏幕详细信息 .........................................................................................................39
集成设备详细信息........................................................................................................................................................40
串行通信详细信息.........................................................................................................................................................41
System Profile Settings (系统配置文件设置) 详细信息 .......................................................................................41
“系统安全设置”详细信息....................................................................................................................................... 42
Miscellaneous Settings (其他设置) 的详细信息 ....................................................................................................43
关于引导管理器..................................................................................................................................................................44
查看引导管理器............................................................................................................................................................ 44
引导管理器主菜单........................................................................................................................................................44
关于 Dell 生命周期控制器................................................................................................................................................. 45
更改引导顺序...................................................................................................................................................................... 45
选择系统引导模式..............................................................................................................................................................45
创建系统密码或设置密码................................................................................................................................................. 45
使用您的系统密码保护您的系统.....................................................................................................................................46
删除或更改系统密码和设置密码.....................................................................................................................................46
在已启用设置密码的情况下进行操作.............................................................................................................................47
嵌入式系统管理.................................................................................................................................................................. 47
iDRAC 设置公用程序..........................................................................................................................................................47
进入 iDRAC 设置公用程序...........................................................................................................................................47
更改热设置.....................................................................................................................................................................47
章 6: 安装和卸下系统组件................................................................................................................49
安全说明.............................................................................................................................................................................. 49
拆装计算机内部组件之前................................................................................................................................................. 50
拆装计算机内部组件之后................................................................................................................................................. 50
建议工具.............................................................................................................................................................................. 50
前挡板( 可选)...................................................................................................................................................................51
安装可选的前挡板.........................................................................................................................................................51
卸下可选的前挡板.........................................................................................................................................................51
系统支脚.............................................................................................................................................................................. 52
卸下系统支脚................................................................................................................................................................ 52
安装系统支脚................................................................................................................................................................ 53
4
目录
脚轮 - 可选...........................................................................................................................................................................54
安装脚轮.........................................................................................................................................................................54
卸下脚轮........................................................................................................................................................................ 55
系统护盖.............................................................................................................................................................................. 56
卸下系统护盖................................................................................................................................................................ 56
安装系统护盖................................................................................................................................................................ 57
系统内部.............................................................................................................................................................................. 59
光盘驱动器和磁带驱动器( 可选).................................................................................................................................59
卸下光盘驱动器或磁带驱动器...................................................................................................................................60
安装光盘驱动器或磁带机............................................................................................................................................ 61
冷却导流罩.......................................................................................................................................................................... 63
卸下冷却导流罩............................................................................................................................................................ 63
安装冷却导流罩............................................................................................................................................................ 64
防盗开关.............................................................................................................................................................................. 65
卸下防盗开关................................................................................................................................................................ 65
安装防盗开关................................................................................................................................................................ 66
硬盘驱动器.......................................................................................................................................................................... 67
支持的硬盘驱动器配置................................................................................................................................................67
卸下 3.5 英寸热插拔硬盘驱动器托盘挡片............................................................................................................... 67
安装 3.5 英寸热插拔硬盘驱动器托盘挡片...............................................................................................................68
卸下热插拔硬盘驱动器托盘....................................................................................................................................... 69
从硬盘驱动器托盘中卸下热交换硬盘驱动器.......................................................................................................... 70
将热插拔硬盘驱动器安装到热插拔硬盘驱动器托盘中.......................................................................................... 71
安装热插拔硬盘驱动器托盘........................................................................................................................................72
将 2.5 英寸热插拔硬盘驱动器安装到 3.5 英寸硬盘驱动器适配器中..................................................................73
将 3.5 英寸硬盘驱动器适配器安装到 3.5 英寸热插拔硬盘驱动器托盘中..........................................................74
从 3.5 英寸热插拔硬盘驱动器托盘中卸下 3.5 英寸硬盘驱动器适配器..............................................................75
将 2.5 英寸热插拔硬盘驱动器从 3.5 英寸硬盘驱动器适配器中卸下..................................................................76
硬盘驱动器背板.................................................................................................................................................................. 76
卸下硬盘驱动器背板.................................................................................................................................................... 77
安装硬盘驱动器背板....................................................................................................................................................80
四插槽硬盘驱动器挡片...................................................................................................................................................... 81
卸下四插槽硬盘驱动器挡片........................................................................................................................................ 81
安装四插槽硬盘驱动器挡片....................................................................................................................................... 82
系统内存...............................................................................................................................................................................83
一般内存模块安装原则................................................................................................................................................84
内存配置示例................................................................................................................................................................ 84
卸下内存模块................................................................................................................................................................ 85
安装内存模块................................................................................................................................................................ 86
冷却风扇...............................................................................................................................................................................87
卸下内部冷却风扇........................................................................................................................................................ 87
安装内部冷却风扇........................................................................................................................................................88
内部 USB 存储钥匙( 可选)........................................................................................................................................... 89
安装可选的内置 USB 存储盘......................................................................................................................................89
扩展卡...................................................................................................................................................................................90
扩展卡安装原则............................................................................................................................................................90
卸下扩展卡..................................................................................................................................................................... 91
安装扩展卡.................................................................................................................................................................... 93
SD vFlash 卡( 可选 ) ........................................................................................................................................................95
目录
5
卸下可选的 SD vFlash 卡.............................................................................................................................................95
安装可选的 SD vFlash 卡.............................................................................................................................................95
iDRAC 端口卡( 可选 ) ..................................................................................................................................................... 96
卸下可选的 iDRAC 端口卡.......................................................................................................................................... 96
安装可选的 iDRAC 端口卡...........................................................................................................................................97
内部双 SD 模块( 可选).................................................................................................................................................. 99
卸下( 可选) 内置 SD 卡............................................................................................................................................ 99
安装( 可选) 内置 SD 卡...........................................................................................................................................100
卸下可选的内置双 SD 模块 ...................................................................................................................................... 101
安装可选的内置双 SD 模块 ......................................................................................................................................102
散热器和处理器................................................................................................................................................................ 103
卸下散热器...................................................................................................................................................................103
卸下处理器...................................................................................................................................................................104
安装处理器...................................................................................................................................................................106
安装散热器...................................................................................................................................................................108
电源设备.............................................................................................................................................................................109
冗余 AC 电源单元........................................................................................................................................................110
非冗余交流/ 有线电源设备.........................................................................................................................................115
电源插入器板..................................................................................................................................................................... 118
卸下电源插入器板....................................................................................................................................................... 118
安装电源插入器板....................................................................................................................................................... 119
系统电池 ............................................................................................................................................................................120
更换系统电池...............................................................................................................................................................120
控制面板部件......................................................................................................................................................................121
卸下控制面板部件....................................................................................................................................................... 121
安装控制面板部件.......................................................................................................................................................123
卸下控制面板部件护盖.............................................................................................................................................. 124
安装控制面板部件护盖.............................................................................................................................................. 124
卸下控制面板...............................................................................................................................................................125
安装控制面板...............................................................................................................................................................126
卸下 LCD 模块..............................................................................................................................................................127
安装 LCD 模块............................................................................................................................................................. 128
卸下可选的 VGA 模块................................................................................................................................................ 129
安装可选的 VGA 模块................................................................................................................................................ 130
系统板..................................................................................................................................................................................131
卸下系统板....................................................................................................................................................................131
安装系统板................................................................................................................................................................... 133
使用 Easy Restore 功能还原服务标签.....................................................................................................................135
使用系统设置程序输入系统服务编号..................................................................................................................... 135
可信平台模块.....................................................................................................................................................................136
安装可信平台模块.......................................................................................................................................................136
为 BitLocker 用户初始化 TPM...................................................................................................................................137
为 TXT 用户初始化 TPM............................................................................................................................................137
系统顶盖............................................................................................................................................................................. 137
卸下系统顶盖............................................................................................................................................................... 137
安装系统顶盖...............................................................................................................................................................138
章 7: 将该系统由塔式模式转换为机架模式.........................................................................................140
将系统从塔式转换为机架式的安全说明.......................................................................................................................140
6
目录
准备用于转换塔式模式为机架模式的系统...................................................................................................................140
章 8: 使用系统诊断程序..................................................................................................................142
Dell 嵌入式系统诊断程序.................................................................................................................................................142
何时使用 Embedded System Diagnostics( 嵌入式系统诊断程序).................................................................. 142
从引导管理器运行嵌入式系统诊断程序................................................................................................................. 142
从 Dell Lifecycle Controller 运行嵌入式系统诊断程序...........................................................................................142
系统诊断程序控件.......................................................................................................................................................143
章 9: 跳线和连接器........................................................................................................................144
系统板跳线和连接器........................................................................................................................................................ 144
系统板跳线设置................................................................................................................................................................ 145
禁用已忘记的密码............................................................................................................................................................ 146
章 10: 系统故障处理.......................................................................................................................147
故障处理系统启动故障.................................................................................................................................................... 147
外部连接故障处理.............................................................................................................................................................147
视频子系统故障处理........................................................................................................................................................ 148
USB 设备故障处理 ............................................................................................................................................................148
iDRAC Direct 故障处理 - USB XML 配置 ...................................................................................................................... 149
iDRAC Direct 故障处理 - 笔记本电脑连接 ....................................................................................................................149
串行输入和输出设备故障处理 ........................................................................................................................................149
NIC 故障处理 ..................................................................................................................................................................... 150
受潮系统故障处理............................................................................................................................................................ 150
受损系统故障处理.............................................................................................................................................................151
系统电池故障处理.............................................................................................................................................................151
电源装置故障处理............................................................................................................................................................ 152
电源问题故障处理...................................................................................................................................................... 152
电源设备故障...............................................................................................................................................................152
冷却问题故障排除............................................................................................................................................................ 153
冷却风扇故障处理............................................................................................................................................................ 153
系统内存故障处理............................................................................................................................................................ 154
内部 USB 闪存盘故障处理.............................................................................................................................................. 154
micro SD 卡故障处理........................................................................................................................................................155
光驱故障处理.....................................................................................................................................................................155
磁带备份装置故障排除....................................................................................................................................................156
驱动器或 SSD 故障处理.................................................................................................................................................. 156
存储控制器故障处理........................................................................................................................................................ 157
扩展卡故障处理.................................................................................................................................................................157
处理器故障处理................................................................................................................................................................ 158
章 11: 获取帮助............................................................................................................................. 159
联系 Dell EMC....................................................................................................................................................................159
通过使用 QRL 访问系统信息..........................................................................................................................................159
目录
7
关于 Dell PowerEdge T330 系统
Dell PowerEdge T330 是单路机架式服务器, 支持以下硬件配置:
1
组件
处理器
内存模块
硬盘驱动器
主题:
• PowerEdge T330 系统支持的配置
• 前面板
• 背面板功能部件
• 诊断指示灯
• 找到系统的服务标签
数量
服务器支持来自以下产品系列的一个处理器
● 英特尔 E3-1200 v5 或 v6 系列
● 英特尔酷睿 i3 6100 系列
● 英特尔赛扬 G3900 系列
● 英特尔赛扬 G3930
● 英特尔酷睿 G4500 系列
● 英特尔酷睿 G4600 系列
多达四个 DIMM
多达八个硬盘驱动器或固态驱动器 (SSD)
8 关于 Dell PowerEdge T330 系统
PowerEdge T330 系统支持的配置
图 1: 所支持配置的系统视图
关于 Dell PowerEdge T330 系统 9
前面板
通过前面板, 可以获得服务器前端提供的功能, 例如电源按钮、NMI 按钮、系统标识标签、系统标识按钮以及 USB 和 VGA 端口。。
诊断 LED 或 LCD 面板都醒目地位于前面板上。从前面板可以触到热插拔硬盘驱动器。
前面板功能部件和指示灯——塔式模式
图 2: 前面板功能部件和指示灯—八个 3.5 英寸热插拔硬盘驱动器机箱
表. 1: 前面板功能部件和指示灯—八个 3.5 英寸热插拔硬盘驱动器机箱
项目 指示灯、按钮或连接器 图标 说明
1
10 关于 Dell PowerEdge T330 系统
通电指示灯、电源按钮
允许您了解系统的电源状态。当系统接通电源时, 开机指示灯将
亮起。电源按钮控制到系统的电源设备输出。
表. 1: 前面板功能部件和指示灯—八个 3.5 英寸热插拔硬盘驱动器机箱 ( 续)
项目 指示灯、按钮或连接器 图标 说明
注: 对于兼容 ACPI 的操作系统, 使用电源按钮关闭系统可以
在系统电源关闭前执行正常有序的关机操作。
2 NMI 按钮
3
4 LCD 菜单按钮 用于导航控制面板 LCD 菜单。
5
6 LCD 面板 显示系统 ID、状态信息和系统错误信息。请参阅 LCD 面板 页面
7 USB 管理端口 /iDRAC 直接端口 用作常规的 USB 端口, 或者提供对 iDRAC Direct 功能的访问权
系统识别按钮 允许您找到机架中的特定系统。识别按钮位于前面板和背面板
信息标签
用于在运行某些操作系统时对软件和设备驱动程序错误进行故障
排除。可以用回形针的末端按压此按钮。
只有当合格的支持人员或操作系统说明文件指示可以使用此按钮
时才能使用它。
上。当按下其中一个按钮时, 系统前面板上的 LCD 面板和后面
板上的系统状态指示灯将闪烁, 直至再次按下其中一个按钮为
止。
按下系统识别按钮时将打开或关闭系统 ID 。
如果系统在 POST 过程中停止响应, 按住系统 ID 按钮五秒以
上, 可进入 BIOS 进程模式。
要重设 iDRAC( 如果在 F2 iDRAC 设置中未禁用), 请按住该按
钮并保持 15 秒以上。
特定系统信息, 例如服务标签、NIC 、MAC 地址等, 可供您参
考。信息标签是一种滑出式标签面板。
上的 14 。
限。有关更多信息, 请参阅 Dell.com/idracmanuals 上提供的
iDRAC Guide ( iDRAC 指南) 。
该端口符合 USB 2.0 标准
8 USB 连接器 允许您将 USB 设备连接到系统。此端口兼容 USB 3.0。
9
10
光盘驱动器或磁带驱动器 使您能够安装光盘驱动器或磁带机。有关支持的光盘驱动器和磁
带机的更多信息, 请参阅 光盘驱动器和磁带驱动器( 可选) 页
面上的 59。
硬盘驱动器
用于安装最多八个 3.5 英寸(2.5 英寸带有适配器) 热插拔硬盘
驱动器/SSD 。
关于 Dell PowerEdge T330 系统 11
图 3: 前面板功能部件和指示灯—四个 3.5 英寸热插拔硬盘驱动器机箱
表. 2: 前面板功能部件和指示灯—四个 3.5 英寸热插拔硬盘驱动器机箱
项目 指示灯、按钮或连接器 图标 说明
1
通电指示灯、电源按钮
允许您了解系统的电源状态。当系统接通电源时, 开机指示灯将
亮起。电源按钮控制到系统的电源设备输出。
注 : 对于兼容 ACPI 的操作系统, 使用电源按钮关闭系统可以
在系统电源关闭前执行正常有序的关机操作。
2 NMI 按钮
3
12 关于 Dell PowerEdge T330 系统
系统识别按钮 允许您找到机架中的特定系统。识别按钮位于前面板和背面板
用于在运行某些操作系统时对软件和设备驱动程序错误进行故障
排除。可以用回形针的末端按压此按钮。
只有当合格的支持人员或操作系统说明文件指示可以使用此按钮
时才能使用它。
上。当按下其中一个按钮时, 系统前面板上的 LCD 面板和后面
表. 2: 前面板功能部件和指示灯—四个 3.5 英寸热插拔硬盘驱动器机箱 ( 续)
项目 指示灯、按钮或连接器 图标 说明
板上的系统状态指示灯将闪烁, 直至再次按下其中一个按钮为
止。
按下系统识别按钮时将打开或关闭系统 ID 。
如果系统在 POST 过程中停止响应, 按住系统 ID 按钮五秒以
上, 可进入 BIOS 进程模式。
要重设 iDRAC( 如果在 F2 iDRAC 设置中未禁用), 请按住该按
钮并保持 15 秒以上。
4 LCD 菜单按钮 允许您导航控制面板 LCD 菜单。
5
6 LCD 面板 显示系统 ID、状态信息和系统错误信息。请参阅 LCD 面板 页面
7 USB 管理端口 /iDRAC 直接端口 用作常规的 USB 端口, 或者提供对 iDRAC Direct 功能的访问权
8 USB 连接器 允许您将 USB 设备连接到系统。此端口兼容 USB 3.0。
信息标签
特定系统信息, 例如服务标签、NIC 、MAC 地址等, 可供您参
考。信息标签是一种滑出式标签面板。
上的 14 。
限。有关更多信息, 请参阅 Dell.com/idracmanuals 上提供的
iDRAC Guide ( iDRAC 指南) 。
该端口符合 USB 2.0 标准
9
10
11
光盘驱动器或磁带驱动器 使您能够安装光盘驱动器或磁带机。有关支持的光盘驱动器和磁
带机的更多信息, 请参阅 光盘驱动器和磁带驱动器( 可选) 页
面上的 59。
硬盘驱动器
四插槽硬盘驱动器挡片
用于安装最多四个 3.5 英寸(2.5 英寸带有适配器) 热插拔硬盘
驱动器/SSD 。
受带一个 x8 硬盘驱动器底板配置的系统支持并且支持软件 RAID
配置。这些系统仅支持四个硬盘驱动器, 剩余的硬盘驱动器插槽
预装有四插槽硬盘驱动器挡片, 但不能进行额外存储升级。
前面板功能部件和指示灯——机架模式
图 4: 前面板功能部件和指示灯——机架模式
关于 Dell PowerEdge T330 系统 13
表. 3: 前面板功能部件和指示灯——机架模式
项目 指示灯、按钮或连接器 图标 说明
1
通电指示灯、电源按钮
允许您了解系统的电源状态。当系统接通电源时, 开机指示灯将
亮起。电源按钮控制到系统的电源设备输出。
注 : 对于兼容 ACPI 的操作系统, 使用电源按钮关闭系统可以
在系统电源关闭前执行正常有序的关机操作。
2 NMI 按钮
3
4 LCD 菜单按钮 用于导航控制面板 LCD 菜单。
5
6 LCD 面板 显示系统 ID、状态信息和系统错误信息。请参阅 LCD 面板 页面
7 USB 管理端口 /iDRAC 直接端口 用作常规的 USB 端口, 或者提供对 iDRAC Direct 功能的访问权
系统识别按钮 允许您找到机架中的特定系统。识别按钮位于前面板和背面板
信息标签
用于在运行某些操作系统时对软件和设备驱动程序错误进行故障
排除。可以用回形针的末端按压此按钮。
只有当合格的支持人员或操作系统说明文件指示可以使用此按钮
时才能使用它。
上。当按下其中一个按钮时, 系统前面板上的 LCD 面板和后面
板上的系统状态指示灯将闪烁, 直至再次按下其中一个按钮为
止。
按下系统识别按钮时将打开或关闭系统 ID 。
如果系统在 POST 过程中停止响应, 按住系统 ID 按钮五秒以
上, 可进入 BIOS 进程模式。
要重设 iDRAC( 如果在 F2 iDRAC 设置中未禁用), 请按住该按
钮并保持 15 秒以上。
特定系统信息, 例如服务标签、NIC 、MAC 地址等, 可供您参
考。信息标签是一种滑出式标签面板。
上的 14 。
限。有关更多信息, 请参阅 Dell.com/idracmanuals 上提供的
iDRAC Guide ( iDRAC 指南) 。
该端口符合 USB 2.0 标准
8
9 USB 连接器 允许您将 USB 设备连接到系统。此端口兼容 USB 3.0。
10
11
视频连接器 可用于将显示屏连接到系统。
注 : 视频连接器仅适用于系统的机架模式配置。有关将您的
系统从塔式模式转换为机架模式的信息, 请参阅 准备用于转
换塔式模式为机架模式的系统 页面上的 140。
光盘驱动器或磁带驱动器 使您能够安装光盘驱动器或磁带机。有关支持的光盘驱动器和磁
带机的更多信息, 请参阅 光盘驱动器和磁带驱动器( 可选) 页
面上的 59。
硬盘驱动器
用于将多达八个 3.5 英寸(2.5 英寸带有适配器) 热插拔硬盘驱
动器或四个 3.5 英寸(2.5 英寸带有适配器) 热插拔硬盘驱动
器。
LCD 面板
系统的 LCD 面板提供了系统信息、状态和错误消息, 以指示系统是否正确运行或者系统是否需要引起注意。有关错误消息的更多信
息, 请参阅 Dell.com/openmanagemanuals >OpenManage software( OpenManage 软件) 的 Dell Event and Error Messages
Reference Guide (Dell 事件和错误消息参考指南) 。
● 系统正常运行期间,LCD 背景光呈蓝色亮起。
● 系统需要予以注意时,LCD 呈琥珀色亮起, 并显示错误代码, 并且后面跟随有描述性文本。
注 : 如果系统已连接至电源并且检测到错误, 则无论系统是否开启 , LCD 都呈琥珀色亮起。
● LCD 背景光将在系统处于待机模式时关闭, 并可通过按 LCD 面板上的选择、向左或向右按钮来打开。
14 关于 Dell PowerEdge T330 系统
● 如果通过 iDRAC 公用程序、LCD 面板或其他工具关闭了 LCD 消息显示,LCD 背景光将处于不亮状态。
图 5: LCD 面板功能部件
表. 4: LCD 面板功能部件
项目 按钮 说明
1
2
3
左 使光标向后移动一步。
选择 选择由光标高亮度显示的菜单项。
右 使光标向前移动一步。
在信息滚动过程中:
● 按住电源按钮可提高滚动速度。
● 松开按钮可停止。
注 : 当松开按钮时, 显示屏将停止滚动。在处于不活动状态 45 秒后, 显示屏
将开始滚动。
查看主页屏幕
Home (主页) 屏幕显示有关系统的用户可配置信息。在系统正常运行过程中没有状态消息或错误时, 即会显示此屏幕。当系统关闭
并且没有错误时,LCD 将在不活动状态五分钟后进入待机模式。按下 LCD 上的任何)按钮将其打开。
步骤
1. 按三个导航按钮( 选择、向左或向右) 中的任意一个, 即可查看 Home( 主页) 屏幕。
2. 要从其他菜单导航至主屏幕, 请完成以下步骤:
a. 按住导航按钮直到显示向上箭头 。
b. 使用向上箭头 导航到
c. 选择主屏幕 图标。
d. 从主屏幕 中按 Select( 选择) 按钮, 进入主菜单。
设置菜单
注: 在 Setup(设置 )菜单中选择一个选项后 ,必须确认该选项 ,然后才能进行下一项操作。
选项 说明
iDRAC 选择 DHCP 或 Static IP(静态 IP )以配置网络模式。如果选择了 Static IP(静态 IP ),则可用字段为 IP、
Subnet (Sub)(子网 [Sub] )和 Gateway (Gtw)(网关 [Gtw] )。选择 Setup DNS(设置 DNS )以启用
DNS 并查看域地址。有两个独立的 DNS 条目可用。
Set error (设置错 误 ) 选择 SEL , 以与 SEL 中的 IPMI 说明匹配的格式查看 LCD 错误消息。这样您能够将 LCD 消息与 SEL 条目匹
配。
关于 Dell PowerEdge T330 系统 15
选项 说明
选择 Simple( 简单 ), 在简化的、用户友好的说明中查看 LCD 错误消息。有关错误消息的更多信息 , 请参阅
Dell.com/openmanagemanuals > OpenManage software 上的 Dell Event and Error Messages Reference
Guide(Dell 事件和错误消息参考指南 )。
Set home (设置主
屏幕)
选择要在主 屏幕上显示的默认信息。请参阅 View( 视图) 菜单部分以查看可以设置为主 屏幕上默认设置的选
项和选项项目。
视图菜单
注: 在“视图”菜单中选择一个选项后, 必须确认该选项, 然后才能进行下一项操作。
选项 说明
iDRAC IP 显示 iDRAC8 的 IPv4 或 IPv6 地址。地址包括 DNS(主要和 次要 )、网关 、 IP 及子网( IPv6 没有子网) 。
MAC 显示 iDRAC、 iSCSI 或网络 设备的 MAC 地址。
名称
编号 显示系统的 资产标签或 服务标签。
功率
温度
显示系统的 Host( 主机) 名称、Model( 型号) 或 User String( 用户字符串) 。
显示系统的电源输出( 以 BTU/小时或瓦特为单位) 。可以在 Setup( 设置) 菜单的 Set home( 设置主屏
幕) 中配置显示格式。
显示系统的温度( 以摄氏或华氏为单位) 。可以在 Setup( 设置) 菜单的 Set home( 设置主屏幕) 中配置显
示格式。
16 关于 Dell PowerEdge T330 系统
背面板功能部件
背面板提供了接触服务器背部功能部件的途径, 例如系统识别按钮、电源设备插槽、电缆固定臂连接器、iDRAC 存储介质、NIC 端
口、USB 和 VGA 端口。大部分扩展卡端口可以从背面板接触。热插拔电源设备单元以及可从后部接触的硬盘驱动器( 如果已安装)
均可通过背面板接触。
背面板功能部件和指示灯
图 6: 背面板功能部件和指示灯
表. 5: 背面板功能部件和指示灯
项目 指示灯、按钮或连接器 图标 说明
1 电源单元( PSU1 和 PSU2) 用于安装多达两个 495 W 冗余和 350 W 非冗余交流电源单元。
注: 在带 x8 背板的系统中支持非冗余 PSU 。
2、 3 USB 连接器( 6 个) 用于将 USB 设备连接到系统。四个 USB 2.0 兼容端口和两个
USB 3.0 兼容端口。
关于 Dell PowerEdge T330 系统 17
表. 5: 背面板功能部件和指示灯 ( 续)
项目 指示灯、按钮或连接器 图标 说明
4.5 以太网连接器( 2 个) 用于连接两个集成的 10/100/1000 Mbps NIC 连接器。
6 vFlash 介质卡插槽( 可选) 用于插入 vFlash 介质卡。
7
8
9
10
11 iDRAC 端口( 可选)
12 PCIe 扩展卡插槽( 4 个) 用于连接多达四个全高 PCI Express 扩展卡。
系统识别按钮 用于查找机架中的特定系统。识别按钮位于前面板和背面板
上。当按下其中一个按钮时,系统前面板上的 LCD 面板和后面板
上的系统状态指示灯将闪烁, 直至再次按下其中一个按钮为
止。
按下系统识别按钮时将打开或关闭系统 ID 。
如果系统在 POST 过程中停止响应, 按住系统 ID 按钮五秒以
上, 可进入 BIOS Progress( BIOS 进程) 模式。
要重设 iDRAC( 如果在 F2 iDRAC 设置中未禁用), 则按住 15
秒以上。
系统识别连接器 可让您通过可选的电缆管理臂连接可选的系统状态指示灯部
件。
视频连接器
串行连接器 允许您将串行设备连接到系统。
允许您将 VGA 显示屏连接到系统。
用于安装专用的管理端口卡。
诊断指示灯
系统上的诊断指示灯指示操作和错误状态。
前面板上的诊断指示灯
注: 当系统关闭时诊断指示灯不亮。要启动系统, 将系统连接至正常工作的电源并按下电源按钮。
表. 6: 诊断指示灯
图标 说明 状态 纠正措施
运行状况指示灯
硬盘指示灯
如果系统运行状况良好, 指示灯会
持续亮起蓝色。
指示灯闪烁琥珀色:
● 当系统处于开启状态时。
● 当系统处于待机状态时。
● 如果存在任何错误条件。如果存
在任何错误条件。例如, 风扇、
PSU 或硬盘发生故障。
如果存在硬盘错误, 指示灯呈琥珀
色闪烁。
无需采取措施。
请参阅 System Event Log( 系统事件日志) 或系统消息
了解特定问题。有关错误消息的更多信息, 请参阅 Dell
Event and Error Messages Reference Guide(Dell
和错误消息参考指南)
openmanagemanuals > OpenManage software 。
由于内存配置无效,POST 过程中断而不具有任何视频
输出。请参阅“获得帮助”部分。请参阅“获得帮助”
部分。
请参阅“系统事件日志”确定出现错误的硬盘。运行相
应的联机诊断检测程序。重新启动系统并运行嵌入式诊
断程序 (ePSA) 。如果硬盘是在 RAID 阵列中配置的, 则
重新启动系统并进入主机适配器配置实用程序。
事件
, 网址 : Dell.com/
18 关于 Dell PowerEdge T330 系统
表. 6: 诊断指示灯 ( 续)
图标 说明 状态 纠正措施
电子指示灯
温度指示灯
内存指示灯
如果系统遇到电气错误( 例如, 电
压超出范围或电源装置或稳压器出
现故障), 指示灯将闪烁琥珀色。
如果系统遇到散热错误( 例如, 环
境温度超出范围或风扇故障), 指
示灯将闪烁琥珀色。
如果发生内存错误, 指示灯将呈琥
珀色闪烁。
请参阅 System Event Log( 系统事件日志) 或系统消息
了解特定问题。如果问题出自电源装置, 则检查电源装
置上的 LED 。重新拔插 PSU 。如果问题仍然存在, 请
参阅“获得帮助”部分。
确保不存在以下任何情况:
● 冷却风扇已卸下或出现故障。
● 系统护盖、冷却导流罩、EMI 填充面板、内存模块
挡片或后填料支架已卸。
● 环境温度太高。
● 外部通风受阻。
请参阅“获得帮助”部分。
请参阅系统事件日志或系统消息, 查看故障内存的位
置。重新安置内存模块如果问题仍然存在, 请参阅“获
得帮助”部分。
硬盘驱动器指示灯代码
每个硬盘驱动器托盘都有一个活动指示灯和一个状态指示灯。指示灯提供硬盘驱动器当前状态的相关信息。活动 LED 指示硬盘驱动
器当前是否正在使用。状态 LED 指示硬盘驱动器的电源状况。
图 7: 硬盘驱动器指示灯
1. 硬盘驱动器活动指示灯
2. 硬盘驱动器状态指示灯
3. 硬盘驱动器
注: 如果硬盘驱动器处于高级主机控制器接口 (AHCI) 模式, 状态指示灯( 右侧) 不会亮起。
表. 7: 硬盘驱动器指示灯代码
驱动器状态指示灯显示方式 状态
每秒呈绿色闪烁两次 识别驱动器或准备卸下。
Off (关)
准备插入或卸下驱动器。
关于 Dell PowerEdge T330 系统 19
表. 7: 硬盘驱动器指示灯代码 ( 续)
驱动器状态指示灯显示方式 状态
注: 在系统开机之后所有硬盘驱动器都初始化之前, 驱动器状态
指示灯会一直保持熄灭。此时, 驱动器不能进行插入或卸下操
作。
闪烁绿色、琥珀色, 然后熄灭
每秒闪烁琥珀色光四次 驱动器故障
缓慢闪烁绿光 正在重建驱动器
呈绿色稳定亮起 驱动器联机
呈绿色闪烁三秒, 呈琥珀色闪烁三秒, 然后在六秒钟后熄灭
预测的驱动器故障
重建已停止
NIC 指示灯代码
后面板上的 NIC 具有指示灯, 可提供关于网络活动和链路状态的信息。活动 LED 指示 NIC 当前是否已连接。链路 LED 指示连接网络
的速度。
图 8: NIC 指示灯代码
1. 链路指示灯
2. 活动指示灯
表. 8: NIC 指示灯
惯例 状态 状态
A
B
C
D
链路和活动指示灯不亮。
链路指示灯呈绿色亮起。
链路指示灯呈琥珀色
活动指示灯闪烁。绿色 正在发送或接收网络数据。
NIC 未连接至网络。
NIC 以其最高端口速度( 1 Gbps 或 10 Gbps)连接到有效
的网络。
NIC 以低于其最高端口速度的速度连接到有效的网络。
内部双 SD 模块指示灯代码
内部双 SD 模块 (IDSDM) 提供了多余 SD 卡的解决方案。您可以配置 IDSDM 用于存储或作为操作系统的引导分区。IDSDM 卡具有以
下功能:
● 双卡操作 — 两个插槽均使用 SD 卡保持镜像配置, 并提供冗余。
20 关于 Dell PowerEdge T330 系统
注: 当 Redundancy(冗余 )选项在系统设置程序的 Integrated Devices(集成设备 )屏幕中设置为 Mirror Mode(镜像模式 )
时, 信息从一个 SD 卡复制到另一个。
● 单卡操作 — 支持单卡操作, 但无冗余。
下表介绍了 IDSDM 指示灯代码:
表. 9: IDSDM 指示灯代码
惯例
A
B
C
D
E
IDSDM 指示灯代码
绿色 表示卡处于联机状态。
绿色闪烁 表示重建或活动。
呈琥珀色闪烁 表示卡不匹配或卡出现故障。
琥珀色 表示卡脱机、出现故障或已被写保护。
不亮 表示卡丢失或正在引导。
说明
冗余电源设备单元的指示灯代码
每个交流电源设备单元 (PSU) 均具有发光的半透明手柄, 用于表明是否存在电源或是否出现电源故障。
图 9: AC PSU 状态指示灯
1. AC PSU 状态指示灯或手柄
表. 10: 冗余 AC PSU 状态指示灯
惯例 电源指示灯显示方式 状态
A
B
C 呈绿色闪烁, 然后熄 灭在热添加 PSU 时,PSU 手柄以 4 Hz 速率呈绿色闪烁五下, 随后熄灭。这表明该 PSU
绿色
绿色闪烁
有效的电源已连接到 PSU, PSU 正常运行。
正在更新 PSU 固件时,PSU 手柄呈绿色闪烁。
小心 : 在更新固件时, 请勿断开电源线或拔下 PSU 插头。如果固件更新中断,
PSU 将无法正常工作。您必须使用 Dell Lifecycle Controller 回滚 PSU 固件。有
关更多信息 , 请参阅位于 Dell.com/idracmanuals 上的 Dell Lifecycle Controller
User’ s Guide( Dell Lifecycle Controller 用户指南) 。
在效率、功能集、运行状况和支持的电压方面存在不匹配的情况。
小心: 对于交流 PSU,仅可使用背面贴有扩展电源性能 (EPP) 标签的 PSU。
注: 请确保这两个 PSU 的容量相同。
关于 Dell PowerEdge T330 系统 21
表. 10: 冗余 AC PSU 状态指示灯 ( 续)
惯例 电源指示灯显示方式 状态
注: 混用前几代 Dell PowerEdge 服务器的 PSU 可能导致 PSU 不匹配或系统无法开
启。
D
E
呈琥珀色闪烁
不亮 未连接电源。
表示 PSU 中出现问题。
小心: 在纠正 PSU 不匹配情况时, 请仅更换指示灯闪烁的 PSU。更换另外的 PSU
以构成匹配的 PSU 对将导致错误状况, 并且系统会出现意外关机。要从高输出配
置更改为低输出配置或反之, 必须关闭系统电源。
小心: AC PSU 支持 220 V 和 110 V 输入电压( Titanium PSU 除外, 其仅支持
220 V )。当两个相同的 PSU 接收不同的输入电压时, 它们可以输出不同功率 ,
由此触发不匹配的情况。
小心: 如果使用两个 PSU,二者必须为相同类型且具有相同的最大输出功率。
小心: 不支持交流 PSU 和直流 PSU 混用, 否则会触发不匹配的情况。
非冗余有线电源装置指示灯代码
按下自我诊断按钮, 在系统非冗余已连接电缆的电源设备 (PSU) 上快速检查运行状况。
图 10: 非冗余已连接电缆的交流 PSU 状态指示灯和自我诊断按钮
1. 自我诊断按钮
2. AC PSU 状态指示灯
表. 11: 非冗余 AC PSU 状态指示灯
电源指示灯显示方式 状态
不亮 电源未连接或电源设备出现故障。
绿色
有效的电源已连接到 PSU, PSU 正常运行。
找到系统的服务标签
您的系统由唯一的快速服务代码和服务标签号码来标识。通过拉出信息标签, 可找到位于系统正面的快速服务代码和服务标签。另
外, 该信息也可能位于系统机箱上的不干胶标签上。Dell 使用此信息将支持电话转接到相应的人员。
22 关于 Dell PowerEdge T330 系统
本节介绍了有关系统说明文件资源的信息。
要查看文档资源表中列出的说明文件表:
● 从 Dell EMC 支持站点:
1. 单击表中“位置”列下提供的文档链接。
2. 单击所需的产品或产品版本。
注: 要找到产品名称和型号, 请参阅您的系统正面。
3. 在“产品支持”页面上, 单击 手册和文档 。
● 使用搜索引擎:
○ 在搜索框中键入文档的名称和版本。
表. 12: 系统其他说明文件资源
任务 说明文件 位置
2
说明文件资源
设置系统
配置系统
有关将系统安装和固定到机架中的
更多信息, 请参阅机架解决方案随
附的 Rail Installation Guide 。
有关设置系统的信息, 请参阅系统
随附的 Getting Started Guide 说明文
件。
有关 iDRAC 的功能、配置和登录
iDRAC ,以及远程管理系统的信息,
请参阅 Integrated Dell Remote
Access Controller User's Guide 。
要了解 Remote Access Controller
Admin (RACADM) 子命令和支持的
RACADM 界面的信息, 请参阅
RACADM CLI Guide for iDRAC。
有关 Redfish 及其协议、支持的架构
以及 iDRAC 中实施的 Redfish 的信
息, 请参阅 Redfish API Guide 。
有关 iDRAC 属性数据库组和对象说
明的信息, 请参阅 Attribute Registry
Guide 。
有关较早版本的 iDRAC 说明文件的
信息, 请参阅 iDRAC 文档。
要识别您的系统上可用的 iDRAC 版
本, 在 iDRAC web 界面, 单击 ? >
关于 。
www.dell.com/poweredgemanuals
www.dell.com/poweredgemanuals
www.dell.com/idracmanuals
有关安装该操作系统的信息, 请参
阅操作系统说明文件。
有关更新驱动程序和固件的信息,
请参阅本说明文件中的“下载固件
和驱动程序的方法”部分。
管理系统 有关戴尔提供的系统管理软件的信
息, 请参阅 Dell OpenManage
www.dell.com/
operatingsystemmanuals
www.dell.com/support/drivers
www.dell.com/poweredgemanuals
说明文件资源
23
表. 12: 系统其他说明文件资源 ( 续)
任务 说明文件 位置
Systems Management Overview
Guide。
有关安装、使用 OpenManage 以及
进行故障处理的信息, 请参阅 Dell
OpenManage Server Administrator
User’ s Guide。
有关安装、使用 Dell OpenManage
Essentials 以及进行故障处理的信
息 , 请参阅 Dell OpenManage
Essentials User’ s Guide。
有关安装、使用 Dell OpenManage
Enterprise 以及进行故障处理的信
息 , 请参阅 Dell OpenManage
Essentials User’ s Guide。
有关安装和使用 Dell SupportAssist
的信息, 请参阅 Dell EMC
SupportAssist Enterprise User’ s
Guide。
有关合作伙伴计划企业系统管理的
信息, 请参阅 OpenManage
Connections Enterprise Systems
Management 说明文件。
使用戴尔 PowerEdge RAID 控制器 要了解戴尔 PowerEdge RAID 控制器
www.dell.com/openmanagemanuals
> OpenManage Server Administrator
www.dell.com/openmanagemanuals
> OpenManage Essentials
www.dell.com/openmanagemanuals
> OpenManage Enterprise
https://www.dell.com/
serviceabilitytools
www.dell.com/openmanagemanuals
(PERC)、软件 RAID 控制器或 BOSS
卡的功能以及部署卡的信息, 请参
阅存储控制器说明文件。
www.dell.com/
storagecontrollermanuals
了解事件和错误消息
系统故障处理
有关系统固件和代理( 用于监控系
统组件) 生成的事件和错误消息的
信息, 请参阅“查找错误代码”。
有关发现和排除 PowerEdge 服务器
问题的信息, 请参阅 Server
Troubleshooting Guide。
www.dell.com/qrl
www.dell.com/poweredgemanuals
24
说明文件资源
主题:
• 机箱尺寸
• 机箱重量
• 处理器规格
• 扩展总线规格
• 内存规格
• 电源规格
• 存储控制器规格
• 驱动器规格
• 端口和连接器规格
• 视频规格
• 扩展操作温度
• 环境规格
机箱尺寸
3
技术规格
图 11: Dell PowerEdge T330 系统的机箱尺寸
技术规格
25
表. 13: Dell PowerEdge T330 系统的尺寸
系统
PowerEdge
T330
X(支脚打 开) X(含脚 轮) Xa Y Ya Yb Z Za Zb
304.5 毫米
( 11.99 英
寸)
307.9 毫米
( 12.12 英
寸)
218 毫米
( 8.58 英
寸)
机箱重量
表. 14: 机箱重量
系统 最大重量
PowerEdge T330
36 千克( 79.36 磅)
处理器规格
处理器 规格
类型
PowerEdge T330 支持下面列出的任何一种处理器:
● 英特尔 E3-1200 v5 或 v6 系列
● 英特尔酷睿 i3 6100 系列
● 英特尔赛扬 G3900 系列
● 英特尔赛扬 G3930
● 英特尔酷睿 G4500 系列
● 英特尔酷睿 G4600 系列
471.3 毫米
( 18.55 英
寸)
430.3 毫米
( 16.94 英
寸)
443.3 毫米
( 17.45 英
寸)
594.82 毫
米(23.42
英寸)
578.42 毫
米(22.77
英寸)
542.2 毫米
( 21.34 英
寸)
扩展总线规格
PCI Express 扩
展插槽
插槽 1 连接到处理器的一个全高、半长 x8 PCIe 第 3 代卡插槽
插槽 2 连接到处理器的一个全高、半长 x16 PCIe 第 3 代卡插槽
插槽 3 连接到平台控制器集线器 (PCH) 的一个全高、半长 x1 PCIe 第 3 代卡插槽
插槽 4 连接到 PCH 的一个全高、半长 x8 PCIe 第 3 代卡插槽
规格
内存规格
内存
体系结构
内存模块插槽
内存模块容量
(UDIMM)
最小 RAM 4 GB
最大 RAM 64 GB
规格
1600 MT/s 、1866 MT/s 、2133 MT/s 或 2400 MT/s DDR4 非缓冲 DIMM
支持高级 ECC 或内存优化操作
四个 288 针插槽
4 GB (单列) 、 8 GB (单列和双列) 和 16 GB (双列)
26
技术规格
电源规格
电源设备 规格
每个电源单元
(PSU) 的电源额定
值
每个有线 PSU 的电
源额定值
散热量
电压
495 W (铂金) AC (100–240 V, 50/60 Hz, 6.5 A–3 A)
350 W(铜 ) AC (100–240 V, 50/60 Hz, 5.5 A-3 A)
注 : 散热量是使用电源设备的额定功率来计算的。
最大 1357 BTU / 小时 (350 W PSU )
最大 1908 BTU/ 小时 (495 W PSU)
注 : 此系统也适用于连接到相间电压不超过 230 V 的 IT 电源系统。
100 –240 V 交流、自动调节范围、50/60 Hz
存储控制器规格
存储控制器 规格
存储控制器类型
PERC H730、 PERC H330、 PERC H830、 PERC S130。
注 : 您的系统支持软件 RAID S130 和 PERC 卡。
有关软件 RAID 的更多信息, 请参阅 Dell.com/storagecontrollermanuals 上的 Dell PowerEdge RAID
Controller (PERC) 说明文件。
注: 从嵌入式控制器或软件 RAID 控制器升级到硬件 RAID 控制器不受支持。
驱动器规格
硬盘驱动器
PowerEdge T330 系统支持 SAS、 SATA、近线 SAS 硬盘驱动器和固态驱动器 (SSD)。
驱动器 规格
八个硬盘驱动器系
统
四个硬盘驱动器系
统
光盘驱动器
PowerEdge T330 系统支持一个可选的 SATA DVD-ROM 驱动器或 DVD+/-RW 驱动器。
多达八个 3.5 英寸热插拔 SATA 或近线 SAS 硬盘驱动器
注 : 3.5 英寸托盘中支持 2.5 英寸 SAS 和 SATA SSD 硬盘驱动器
多达四个 3.5 英寸热插拔 SATA 或近线 SAS 硬盘驱动器
注: 3.5 英寸托盘中支持 2.5 英寸 SAS 和 SATA SSD 硬盘驱动器
磁带驱动器
PowerEdge T330 系统支持多达两个可选的 5.25 英寸磁带机
技术规格
27
端口和连接器规格
USB 端口
PowerEdge T330 系统支持 USB 2.0 和 USB 3.0 兼容端口。下表说明了有关 USB 规格的更多信息:
表. 15: USB 规格
系统 前面板 背面板 内部
PowerEdge T330
一个 USB 2.0 兼容端口
一个 USB 3.0 兼容端口
两个 USB 3.0 兼容端口
四个 USB 2.0 兼容端口
一个 USB 3.0 兼容端口
NIC 端口
PowerEdge T330 系统支持背面板上的两个 10/100/1000 Mbps 网络接口控制器 (NIC) 端口。
iDRAC8
PowerEdge T330 系统在 iDRAC Enterprise 端口卡上支持一个可选的专用 1 GbE 以太网。
串行连接器
串行连接器可将串行设备连接至系统。PowerEdge T330 系统支持背面板上的一个串行连接器, 该 9 针连接器是一种兼容 16550 的数
据终端设备 (DTE) 。
VGA 端口
视频图形阵列 (VGA) 端口可让您将系统连接至 VGA 显示屏。PowerEdge T330 系统支持两个 15 针 VGA 端口, 正面和背面面板上各
一个。
SD vFlash
PowerEdge T330 系统在 iDRAC Enterprise 端口卡上支持一个可选的 SD vFlash 内存卡。
注: 只有当您的系统上已安装 iDRAC8 Enterprise 许可证时才可使用此卡插槽。
内部双 SD 模块
PowerEdge T330 系统支持两个含内部双 SD 模块的可选闪存卡插槽。
注: 一个冗余专用的卡插槽。
视频规格
PowerEdge T330 系统支持集成 Matrox G200 和 iDRAC8 以及 16 MB 应用程序内存。
表. 16: 支持的视频分辨率选项
分辨率
640 x 480 60、 70 8、 16、 24
28
技术规格
刷新率 (Hz) 色深( 位)
表. 16: 支持的视频分辨率选项 ( 续)
分辨率
800 x 600 60、 75、 85 8、 16、 24
1024 x 768 60、 75、 85 8、 16、 24
1152 x 864 60、 75、 85 8、 16、 24
1280 x 1024 60、 75 8、 16、 24
刷新率 (Hz) 色深( 位)
扩展操作温度
注: 在扩展温度范围下操作时, 系统性能将会受到影响。
注: 在扩展温度范围下操作时, LCD 和系统事件日志上可能会有环境温度警告。
扩展操作温度 规格
连续工作
相对湿度 (RH) 为 5% 至 85%, 工作温度为 5°C 至 40°C( 40°F 至 104°F), 露点为 29°C (84.2°F) 。
注 : 除了标准操作温度 10°C 至 35°C ( 50°F 至 95°F )之外, 系统能在降到 5°C (40°F) 或高达 40°C
(104°F) 的过程中连续工作。
若温度在 35°C (95°F) 和 40°C (104°F) 之间, 在 950 米(3116.8 英尺) 以上时, 每上升 175 米, 最大允许温
度将下降 1°C( 每 574.14 英尺下降 33.8°F) 。
≤ 每年操作时间的1%相对湿度 (RH) 为 5% 至 90%, 工作温度为 -5°C 至 45°C( 23°F 至 113°F), 露点为 29°C (84.2°F) 。
注: 除了标准操作温度 10°C 至 35°C( 50°F 至 95°F)之外 ,系统能在降到 -5°C (23°F) 或高达 45°C
(113°F) 的过程中工作, 运行时间长达每年操作时间的 1% 。
若温度在 40°C (104°F) 和 45°C (113°F) 之间, 在 950 米(3116.8 英尺) 以上时, 每上升 125 米, 最大允许温
度将下降 1°C( 每 410.105 英尺下降 33.8°F) 。
扩展操作温度限制
● 指定的操作温度适用的最高海拔高度为 3048 米(10,000 英尺) 。
● 不支持非冗余电源单元。
● 有线电源设备的系统不受支持。
● 不支持非 Dell 认证的外围设备卡和/ 或超过 25 W 的外围设备卡。
● 不支持内部磁带备份驱动器 (TBU) 。
● 请勿在 5°C (40°F) 以下执行冷启动。
● 启用处理器性能降级。
环境规格
注: 有关特定系统配置的环境测量值的附加信息, 请参阅 Dell.com/environmental_datasheets。
温度 规格
存储
连续工作( 在低于
海拔 950 米或 3117
英尺时)
新鲜空气
最高温度梯度( 操
作和存储)
–40°C 至 65°C( –40°F 至 149°F)
在设备无直接光照的情况下,10 °C 至 35 °C( 50 °F 至 95 °F) 。
有关新风的详细信息, 请参阅“扩展的工作温度”一节。
20°C/h (68°F/h)
技术规格
29
相对湿度 规格
存储
使用时
最大露点为 33°C (91°F) 时, 相对湿度为 5% 至 95% 。空气必须始终不冷凝。
最大露点为 29 °C (84.2 °F) 时, 相对湿度为 10% 至 80% 。
最大振动 规格
使用时
存储
5 Hz 至 350 Hz 时, 0.26 G
10 Hz 至 500 Hz 时, 1.88 G
最大撞击 规格
使用时
存储
在 x 、 y 和 z 轴正负方向上可承受连续六个 40 G 的撞击脉冲 , 最长可持续 2 毫秒。
x、 y 和 z 轴正负方向上可承受连续六个 71 G 的撞击脉冲( 系统每一面承受一个脉冲), 最长可持续 2 毫秒。
最大海拔高度 规格
使用时
存储
30482000 米( 10,0006560 英尺) 。
12,000 米( 39,370 英尺) 。
工作温度降额 规格
最高达 35 °C (95
°F)
35 °C 至 40 °C
( 95 °F 至 104
°F)
40 °C 至 45 °C
( 104 °F 至 113
°F)
最高温度在 950 米(3,117 英尺) 以上按 1°C/300 米(33.8°F/984.25 英尺) 降低。
最高温度在 950 米(3,117 英尺) 以上时按 1°C/175 米(1 °F/574.14 英尺) 降低。
最高温度在 950 米(3,117 英尺) 以上时按 1°C/125 米(1°F/410.1 英尺) 降低。
( 操作方向) 。
rms
, 可持续 15 分钟 ( 测试所有六面 ) 。
rms
以下部分定义限制范围, 帮助避免颗粒和气体污染导致 IT 设备损坏和/ 或故障。如果颗粒或气体污染级别超过指定的限制范围并导致
设备损坏或发生故障, 您可能需要整改环境条件。整改环境条件是客户的责任。
微粒污染 规格
空气过滤
导电灰尘 空气中不得含有导电灰尘、锌晶须或其他导电颗粒。
腐蚀性灰尘
按照 ISO 14644-1 第 8 类定义的拥有 95% 置信上限的数据中心空气过滤。
注 : 仅适用于数据中心环境。空气过滤要求不适用于旨在数据中心之外( 诸如办公室或工厂车间等环境 )
使用的 IT 设备。
注: 进入数据中心的空气必须拥有 MERV11 或 MERV13 过滤。
注: 适用于数据中心和非数据中心环境。
● 空气中不得含有腐蚀性灰尘。
● 空气中的残留灰尘的潮解点必须小于 60% 相对湿度。
注: 适用于数据中心和非数据中心环境。
气体污染 规格
铜片腐蚀率
银片腐蚀率
注: 腐蚀性污染物最大浓度值在小于等于 50% 相对湿度下测量。
<300 Å/月, 按照 ANSI/ISA71.04-1985 定义的 G1 类标准。
<200 Å/月, 按照 AHSRAE TC9.9 定义的标准。
30
技术规格