Dell™ PowerEdge™ SC 1430 Systems
Information Update
Installing a Fourth Hard Drive
A fourth hard drive requires an optional hard-drive carrier with a cooling fan. Installation steps are
described in "Installing an Optional Fourth Hard Drive" in your Hardware Owner’s Manual. When
performing this procedure, note the following additional information:
NOTE: If a second processor is installed in your system, do not route the fan cable through the narrow space
between the air baffle and the processor heat sink. Open the processor access door on the air baffle and push
the fan cable underneath the heat sink fins to prevent damage to the cable.
System Messages
Table 1 provides an additional system message that your system may display on the screen.
See "System Messages" in your Hardware Owner’s Manual for information about
other system messages.
Table 1. System Messages
MessageCausesCorrective Actions
The FBD link to the
following DIMM failed
to train: DIMM x
Faulty or improperly installed
memory module.
Ensure that only Dell-qualified memory
is used. Dell recommends purchasing
memory upgrade kits directly from
www.dell.com or your Dell sales agent
to ensure compatibility.
Reseat memory modules. See "Memory"
in your Hardware Owner’s Manual.
If the problem persists, see
"Troubleshooting System Memory"
in your Hardware Owner’s Manual.
October 2006
System Setup Program Update
Following are updates to the System Setup program about features that are available on some systems.
Main Screen
Figure 1 shows the updated main System Setup program screen. Table 2 lists a new option on the System
Setup main screen.
Figure 1. Main System Setup Program Screen
Table 2. System Setup Program Options
OptionDescription
Boot Sequence Retry
(Disabled default)
Enables or disables the Boot Sequence Retry feature. When set to Enabled, the
system reattempts the boot sequence after a 30-second timeout if the previous
boot attempt failed.
Integrated Devices Screen
Table 3 lists a new Integrated Devices screen option.
Table 3. Integrated Devices Screen Options
OptionDescription
I/OAT DMA Engine
(Disabled default)
Enables or disables the I/O Acceleration Technology (I/OAT) option. When set
to Enabled, I/OAT reduces system CPU usage for applications that use TCP by
offloading part of the TCP receive operation to the DMA engine.
Diagnostic Indicator Lights
During system startup, at the completion of POST, all four lights are immediately turned off. The lights
cannot be seen to illuminate as described in Table 1-5, "Diagnostic Indicator Codes During POST,"
in your Hardware Owner’s Manual. For further information about codes that may be displayed before
and during POST, see "Diagnostic Indicator Codes" in your Hardware Owner’s Manual.
NOTE: Once the system completes POST, all diagnostic lights will be OFF.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell and the DELL logo are trademarks of Dell Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks
and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
Systèmes Dell™ PowerEdge™ SC 1430
Mise à jour des informations
Installation d'un quatrième disque dur
Pour installer un quatrième disque dur, vous devez utiliser un support en option équipé d'un ventilateur.
Les instructions correspondantes se trouvent dans le document Hardware Owner's Manual (Manuel du
propriétaire), à la section “Installing an Optional Fourth Hard Drive” (Installation d'un quatrième disque
dur en option). Lorsque vous effectuez cette procédure, tenez compte de la remarque suivante :
REMARQUE : si un deuxième processeur est installé, ne faites pas passer le câble du ventilateur dans l'espace
séparant la chicane d'air et le dissipateur de chaleur du processeur. Pour éviter d'endommager ce câble, ouvrez la
porte d'accès au processeur qui se trouve sur la chicane et faites passer le câble sous les ailettes du dissipateur.
Messages système
Le tableau 1 contient un message supplémentaire qui peut s'afficher sur l'écran du système. Pour plus
d'informations sur les autres messages système, voir “System Messages” (Messages système) dans le
document Hardware Owner's Manual (Manuel du propriétaire).
Tableau 1. Messages système
MessageCausesActions correctrices
The FBD link to the
following DIMM failed
to train: DIMM x
Barrette de mémoire
défectueuse ou
mal installée.
Vérifiez que vous utilisez uniquement des barrettes de
mémoire certifiées par Dell. Nous vous recommandons
d'acheter les kits d'extension de mémoire directement
sur le site www.dell.com ou de contacter votre
représentant commercial Dell à cet effet.
Remboîtez les barrettes de mémoire dans leur
logement. Voir la section “Memory” (Mémoire),
dans le document Hardware Owner's Manual
(Manuel du propriétaire).
Si l'incident persiste, voir la section “Troubleshooting
System Memory” (Dépannage de la mémoire système),
dans le document Hardware Owner's Manual
(Manuel du propriétaire).
Octobre 2006
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.