Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, and PowerVault™ are trademarks of Dell Inc.
®
Intel
and Pentium® are registered trademarks of Intel Corporation in the U.S. and other countries.
Microsoft
Microsoft Corporation in the United States and/or other countries. Red Hat
Linux
a registered trademark of Novell, Inc., in the United States and other countries. VMware
trademark of VMware, Inc. in the United States or other countries. Citrix™ is a trademark of Citrix
Systems, Inc. and/or more of its subsidiaries, and may be register ed in the United States Patent and
Trademark Office and in other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
®
, Windows®, and Windows Server® are either trademarks or registered trademarks of
®
are registered trademarks of Red Hat, Inc. in the United States and other countries. SUSE® is
Least Queue Depth With Subset . . . . . . . . . . 78
Least Path Weight With Subset
Changing Load Balance Policies on the
Windows Server 2008 Operating System. . . . . . 78
Increasing Bandwidth With Multiple
iSCSI Sessions
. . . . . . . . . . . . . . . . . . . 79
. . . . . . . . . . . . . . 77
. . . . . . . . . . . 78
DAppendix—Stopping and Starting
iSCSI Services in Linux . . . . . . . . . . . . . . 83
6Contents
Page 7
1
Introduction
This guide provides information about deploying Dell PowerVault MD
MD3200i and Dell PowerVault MD3220i storage arrays. The deployment
process includes:
•Hardware installation
•Modular Disk Storage Manager (MDSM) software installation
•Initial system configuration
Other information provided include system requirements, storage array
organization, and utilities.
NOTE: For more information on product documentation see,
support.dell.com/manuals.
MDSM enables an administrator to configure and monitor storage arrays for
optimum usability. The version of MDSM included on the PowerVault MD
series resource media can be used to manage both the PowerVault MD3200i
series and the earlier PowerVault MD series storage arrays. MDSM is
compatible with both Microsoft Windows and Linux operating systems.
System Requirements
Before installing and configuring the PowerVault MD3200i series hardware
and software, ensure that the operating system is supported and minimum
system requirements are met. For more information, see the Dell PowerVault Support Matrix available on support.dell.com/manuals.
Management Station Requirements
A management station uses MDSM to configure and manage storage arrays
across the network. A management station must meet the following
minimum system requirements:
•Intel Pentium or an equivalent processor (1333 MHz or faster) with 512
MB RAM (1024 MB recommended)
•1 GB disk space
Introduction7
Page 8
•Display resolution of 1024x768 with 16 million colors (1280x1024 32-bit
recommended)
•Microsoft Windows, Red Hat Enterprise Linux, and SUSE Linux
Enterprise Server.
NOTE: Operating system installations can be either native or hypervisor guest
configurations.
NOTE: Supported hypervisors include Microsoft Hyper-V, Citrix XenServer,
and VMware. For information about the supported versions, see the Support
Matrix at support.dell.com.
•Administrator or equivalent permissions
Introduction to Storage Arrays
A storage array includes various hardware components, such as physical disks,
RAID controller modules, fans, and power supplies, gathered into enclosures.
An enclosure containing physical disks accessed through RAID controller
modules is called a storage array.
One or more host servers attached to the storage array can access the data on
the storage array. You can also establish multiple physical paths between the
host(s) and the storage array so that loss of any single path (for example,
through failure of a host server port) does not result in loss of access to data
on the storage array.
The storage array is managed by MDSM running on a:
•Host server—On a host server, MDSM and the storage array communicate
management requests and event information using iSCSI ports.
•Management station—On a management station, MDSM communicates
with the storage array either through an Ethernet connection to the
storage array management port or though an Ethernet connection to a
host server. The Ethernet connection passes management information
between the management station and the storage array using iSCSI ports.
Using MDSM, you can configure the physical disks in the storage array into
logical components called disk groups and then divide the disk groups into
virtual disks. Disk groups are created in the unconfigured capacity of a storage
array. Virtual disks are created in the free capacity of a disk group.
8Introduction
Page 9
Unconfigured capacity comprises of physical disks not already assigned to a
disk group. When a virtual disk is created using unconfigured capacity, a disk
group is automatically created. If the only virtual disk in a disk group is
deleted, the disk group is also deleted. Free capacity is space in a disk group
that is not assigned to any virtual disk.
Data is written to the physical disks in the storage array using RAID
technology. RAID levels define the way in which data is written to physical
disks. Different RAID levels offer different levels of accessibility, redundancy,
and capacity. You can set a specified RAID level for each disk group and
virtual disk on your storage array.
For more information about using RAID and managing data in your storage
solution, see the Owner’s Manual
at
support.dell.com/manuals
.
Introduction9
Page 10
10Introduction
Page 11
2
Hardware Installation
Befo re using thi s guide, ensure that y ou review the instructions in the:
•
Getting Started Guide
the storage array provides information to configure the initial setup of
the system.
•Planning section of the
information
up your storage solution. See the
about important concepts you must know before setting
Planning the Storage Configuration
Consider the following before installing your storage array:
•Evaluate data storage needs and administrative re quirements.
•Calculate availability requirements.
•Decide the frequency and level of backups, such as weekly full backups
with daily partial backups.
•Consider storage array options, such as password protection and e-mail
alert notifications for error conditions.
•Design the configuration of virtual disks and disk groups according to a
data organization plan. For example, use one virtual disk for inventory, a
second for financial and tax information, and a third for customer
information.
•Decide whether to allow space for hot spares, which automatically r eplace
failed physical disks.
—The
Getting Started Guide
Owner’s Manual—
Owner’s Manual
that shipped with
The planing section provides
at
support.dell.com
.
Hardware Installation11
Page 12
Connecting the Storage Array
The storage array is connected to a host using two hot-swappable RAID
controller modules. The RAID controller modules are identified as RAID
controller module 0 and RAID controller module 1.
Each RAID controller module has four iSCSI In port connectors that provide
Ethernet connections to the host server or switches. Each RAID controller
module also contains an Ethernet management port and a SAS Out port. The
Ethernet management port allows you to install a dedicated management
station (server or stand-alone system). The SAS Out port allows you to
connect the storage array to optional PowerVault MD1200 series e xpansion
enclosures for additional storage capacity.
Each PowerVault MD3200i series storage array can be expanded to a
maximum of 120 (or 192, if enabled using Premium Feature activation)
physical disks through a maximum of seven PowerVault MD1200 series
expansion enclosures.
Cabling the Storage Array
The iSCSI interface enables different host-to-controller configurations. The
figures in this chapter are grouped according to the following categories:
•Direct-attached configurations (no Ethernet switches are used)
•Network-attached (SAN) configurations (Ethernet switches are used)
Redundant and Non-Redundant Configurations
Non-redundant configurations are configurations that provide only a single
data path from a host to the storage array. This type of configuration is only
recommended for non-critical data storage. Path failure from a failed or
removed cable, a failed NIC, or a failed or removed RAID controller module
results in loss of host access to storage on the storage array.
Redundancy is established by installing separate data paths between the host
and the storage array, in which each path is to one of the two RAID controller
modules installed in the storage array. Redundancy protects the host from
losing access to data in the event of path failure, because both RAID
controller modules can access all the disks in the storage array.
12Hardware Installation
Page 13
Direct-Attached Configurations
You can connect the Ethernet ports of the host servers directly to the storage
array RAID controller module iSCSI ports.
Single Path Data Configurations
With a single path configuration, a group of heterogeneous hosts can be
connected to the storage array through a single physical Ethernet port. Since
there is only one port, there is no redundancy, although each iSCSI portal
supports multiple connections. This configuration is supported for both
single controller and dual controller modes.
Hardware Installation13
Page 14
Figure2-1 shows a non-redundant cabling configuration to the RAID
Corporate, public,
or private network
Storage array
Server 1Server 2Server 3Server 4
controller modules using a single path data configuration.
Figure 2-1. Four Hosts Connected to a Single Controller
14Hardware Installation
Page 15
Figure 2-2 shows two hosts connected to a single controller array.
Corporate, public,
or private network
Storage array
Server 1
Server 2
Figure 2-2. T wo Hosts Connected to a Single Controller
Hardware Installation15
Page 16
Figure2-3 shows eight stand-alone hosts supported in a dual controller array
Corporate, public,
or private network
Storage array
Server 1
Server 2
Server 3Server 4
Server 8
Up to 8 hosts
configuration with a single data path.
Figure 2-3. Eight Hosts in a Dual-Controller Configuration
16Hardware Installation
Page 17
Dual-Path Data Configuration
In Figure2-4, up to four servers are directly attached to the RAID controller
modules. If the host server has a second Ethernet connection to the array,
it can be attached to the iSCSI ports on the array's second controller.
This configuration provides improved availability by allowing two separate
physical paths for each host, which ensures full redundancy if one of the
paths fail.
In Figure2-5, up to four cluster nodes are directly attached to two RAID
controller modules. Since each cluster node has redundant paths, loss of a
single path would still allow access to the to the storage array through the
alternate path.
Hardware Installation17
Page 18
Figure 2-4. Four Hosts Connected to Two Controllers
Storage array
Server 1Server 2Server 3Server 4
Corporate, public,
or private network
18Hardware Installation
Page 19
Figure 2-5. Four Hosts Connected in a Dual-Controller Configuration
Corporate, public,
or private network
Storage array
Four node cluster server
Hardware Installation19
Page 20
Network-Attached Configurations
You can also cable the host servers to the RAID controller module iSCSI ports
through industry-standard 1GB Ethernet switches. An iSCSI configuration
that uses Ethernet switches is frequently referred to as an IP SAN. By using an
IP SAN, the PowerVault MD3200i series storage array can support up to 64
hosts simultaneously. This configuration supports either single- or dual-path
data configurations and either single or dual controller modules.
Figure2-6 shows up to 64 stand-alone servers attached (using multiple
sessions) to a single RAID controller module through a network. Hosts that
have a second Ethernet connection to the network allow two separate
physical paths for each host, which ensures full redundancy if one of the paths
fail. Figure2-7 shows how the same number of hosts can be similarly attached
to a dual RAID controller module configuration.
20Hardware Installation
Page 21
Corporate, public,
or private network
Up to 64 hosts
Switch
Storage array
Figure 2-6. 64 Servers Connected to a Single Controller
Hardware Installation21
Page 22
Corporate, public,
or private network
Switch
Storage array
Up to 64 hosts
Figure 2-7. 64 Servers Connected to Two Controllers
22Hardware Installation
Page 23
Cabling PowerVault MD1200 Series Expansion
Enclosures
You can expand the capacity of your PowerVault MD3200i series storage array
by adding PowerVault MD1200 series expansion enclosures. You can expand
the physical disk pool to a maximum of 120 (or 192, if enabled using
Premium Feature activation) physical disks using a maximum of seven
expansion enclosures.
Expanding With Previously Configured PowerVault MD1200 Series
Expansion Enclosures
Use this procedure if your expansion enclosure is directly attached to and
configured on a Dell Po werEdge RAID Controller (PER C)H800 adapter. Data
from virtual disks created on a PERC H800 adapter cannot be directly
migrated to a PowerVault MD3200i series storage array or to a PowerVault
MD1200 series expansion enclosure connected to a PowerVault MD3 200i
series storage array.
CAUTION: If a PowerVault MD1200 series expansion enclosure that was
previously attached to PERC H800 adapter is used as an expansion enclosure to a
PowerVault MD3200i series storage array, the physical disks of the expansion
enclosure are reinitialized and data is lost. You must backup all data on the
expansion enclosure before attempting the expansion.
To attach previously configured PowerVault MD1200 series expansion
enclosures to the PowerVault MD3200i series storage array:
1
Back up all data on the expansion enclosure(s).
2
While the enclosure is still attached to the PERC H800 controller,
upgrade the expansion enclosure firmware to the latest version available
at
support.dell.com
Windows systems users can reference the
kernel users can reference the
.
DUP.bin
DUP.exe
package.
package and Linux
3
Ensure that the storage array software is installed and up to date before
adding the expansion enclosure(s).
For more information, see the
support.dell.com/manuals
Support Matrix
.
at
Hardware Installation23
Page 24
a
Install the software and driver package included on the PowerVault
MD series resource media.
For information about installing the software, see "Installing
PowerVault MD Storage Software" on page 25.
b
Update the storage array RAID controller module firmware and
NVSRAM to the latest versions available at
support.dell.com
, using
PowerVault MDSM.
c
Click
Tools
Upgrade RAID Controller Module Firmware
in the
Enterprise Management Window (EMW).
4
Stop all I/O and turn off the system and attached units.
a
Stop all I/O to the storage array and turn off the host systems attached
to the storage array.
b
Turn off the storage array .
c
Turn off the expansion enclosure(s) in the affected system.
5
Cable the expansion enclosure(s) to the storage array.
6
Turn on attached units:
a
Turn on the expansion enclosure(s). Wait for the enclosure status
LED to turn blue.
b
Turn on the storage array and wait for the status LED to indicate that
the unit is ready:
•If the status LEDs are solid amber, the storage array is still coming
online.
•If the status LEDs are blinking amber, there is an error that can be
viewed using the PowerVault MDSM.
•If the status LEDs are solid blue, the storage array is ready.
c
When the storage array is online and ready, turn on any attached host
systems.
7
After the PowerVault MD1200 series expansion enclosure is configured as
an expansion enclosure of the storage array, restore the data that was
backed up in step 1.
After the expansion enclosures are online, they can be accessed as a part of
the storage array.
24Hardware Installation
Page 25
Expanding With New PowerVa ult MD1200 Series Ex pan sion Enclo s ures
Perform the following steps to attach new PowerVault MD1200 series
expansion enclosures to a PowerVault MD3200 i series sto r age array:
1
Before adding the expansion enclosure(s), ensure that the storage array
software is installed and up to date. For more information, see the
Matrix
at
support.dell.com/manuals
a
Install the software and driver package included on the PowerVault
.
MD series resource media.
For information about installing the software, see "The PowerVault
MD series storage software installer provides features that include the
core software, providers, and optional utilities. The core software
feature includes the host-based storage agent, multipath driver, and
MD Storage Manager (MDSM) application used to configure,
manage, and monitor the storage array solution. The providers feature
includes providers for the Microsoft Virtual Disk Service (VDS) and
Microsoft Volume Shadow-Copy Service (VSS) framework. The
PowerVault Modular Disk Configuration Utility (MDCU) is an
optional utility that provides a consolidated approach for configuring
the management ports, iSCSI host ports, and creating sessions for the
iSCSI Modular Disk storage arrays. It is recommended that you install
and use PowerVault MDCU to configure iSCSI on each host
connected to the storage array." on page 27.
b
Set up the PowerVault MD1200 series expansion enclosure(s).
For information about setting up the PowerVault MD1200 series
expansion enclosure(s), see the
support.dell.com/manuals
Hardware Owner’s Manual
.
Support
at
c
Using PowerVault MDSM, update the RAID controller module
firmware and NVSRAM to the latest versions available on
support.dell.com
. From the Enterprise Management Window
(EMW).
d
Click
ToolsUpgrade RAID Controller Module Firmware
2
Stop I/O and turn off all systems:
a
Stop all I/O to the storage array and turn off affected host systems
attached to the storage array.
b
Turn off the storage array .
.
Hardware Installation25
Page 26
c
Turn off any expansion enclosure(s) in the affected system.
3
Cable the expansion enclosure(s) to the storage array.
4
Turn on attached units:
a
Turn on the expansion enclosure(s). Wait for the enclosure status
LED to turn blue.
b
Turn on the storage array and wait for the status LED to indicate that
the unit is ready:
•If the status LEDs are solid amber, the storage array is still coming
online.
•If the status LEDs are blinking amber, there is an error that can be
viewed using PowerVault MDSM.
•If the status LEDs are solid blue, the storage array is ready.
c
After the storage array is online and ready, turn on any attached host
systems.
5
Using PowerVault MDSM, update all attached expansion enclosure
firmware if it is out of date:
a
From the EMW, select the enclosure that you want to update and
b
c
enter the
Click
Select
Array Management Window
AdvancedMaintenance
Select All
to update all the attached expansion enclosures
(AMW).
DownloadEMM Firmware
simultaneously.
.
26Hardware Installation
Page 27
3
Installing PowerVault MD Storage
Software
The Dell PowerVault MD series resource media contains software and drivers
for both Linux and Microsoft Windows operating systems.
The root of the media contains a readme.txt file covering changes to the
software, updates, fixes, patches, and other important data applicable to both
Linux and Windows operating systems. The readme.txt file also specifies
requirements for accessing documentation, information regarding versions of
the software on the media, and system requirements for running the software.
F or mor e information on supported hardwar e and software for PowerVault
systems, see the Support Matrix located at support.dell.com/manuals.
NOTE: It is recommended that you install all the latest updates available at
support.dell.com.
The PowerVault MD series storage software installer provides features that
include the core software, providers, and optional utilities. The core software
feature includes the host-based storage agent, multipath driver, and MD Storage
Manager (MDSM) application used to configure, manage, and monitor the
storage array solution. The providers feature includes providers for the Microsoft
Virtual Disk Service (VDS) and Microsoft V olume Shadow-Copy Service (VSS)
framework. The PowerVault Modular Disk Configuration Utility (MDCU) is an
optional utility that provides a consolidated approach for configuring the
management ports, iSCSI host ports, and creating sessions for the iSCSI Modular
Disk storage arrays. It is recommended that you install and use PowerVault
MDCU to configure iSCSI on each host connected to the storage array .
NOTE: For more information about the Microsoft VDS and Microsoft VSS providers,
see the Owner's Manual. To install the software on a Windows or Linux system, you
must have administrative or root privileges.
Installing PowerVault MD Storage Software27
Page 28
NOTE: If Dynamic Host Configuration Protocol (DHCP) is not used, initial configuration
of the management station must be performed on the same phy sical subnet as the
storage array. Additionally , during initial configuration, at least one netwo rk adapter
must be configured on the same IP subnet as the storage array’s default management
port (192.168.128.101 or 192.168.128.102). After initial configuration, the management
ports are configured using MDSM and the management station’ s IP address can be
changed back to the previous settings.
The PowerVault MD series resource media offers the following three
installation methods:
•Graphical Installation (Recommended)—This is the recommended
installation procedure for most users. The installer presents a graphical
wizard-driven interface that allows customization of which components
are installe d.
•Console Installation—This installation procedur e is useful for Linux users
that do not desire to install an X-Window environment on their supported
Linux platform.
•Silent Installation—This installation procedure is useful for users that
prefer to create scripted installations.
Graphical Installation (Recommended)
The PowerVault MD Storage Manager software configures, manages and
monitors the storage array. The PowerVault MD Configuration Utility
(MDCU) is an optional utility that provides a consolidated approach for
configuring the management and iSCSI host ports, and creating sessions for
the iSCSI modular disk storage arrays. It is recommended that you use
PowerVault MDCU to configure iSCSI on each host server connected to the
storage array. To install the PowerVault MD storage software:
1
Insert the PowerVault MD series resource media.
Depending on your operating system, the installer may launch
automatically. If the installer does not launch automatically, navigate to
the root directory of the installation media (or downloaded installer
image) and run the
navigate to the root of the resource media and run the autorun file.
md_launcher.exe
file. F or Linux-based systems,
NOTE: By default, Red Hat Enterprise Linux mounts the resource media with the
–noexec mount option which does not allow you to run executable files. To change
this setting, see the Readme file in the root directory of the installation media.
28Installing PowerVault MD Storage Software
Page 29
2
Select
Install MD Storage Software.
3
Read and accept the license agreement.
4
Select one of the following installation options from the Install Set
dropdown menu:
•Full (recommended)—Installs the PowerVault MD Storage Manager
(client)software, host-based storage agent, multipath driver, and
hardware providers.
•Host Only—Installs the host-based storage agent and multipath
drivers.
•Management—Installs the management software and hardware
providers.
•Custom—Allows you to select specific components.
5
Select the PowerVault MD storage array model(s) you are setting up to
serve as data storage for this host server.
6
Choose whether to start the event monitor service automatically when the
host server reboots or manually.
NOTE: This option is applicable only to Windows client software installation.
7
Confirm the installation location and choose
8
If prompted, reboot the host server once the installation completes.
9
When the reboot is complete, the P owerVault MDCU may launch
Install
.
automatically. If the PowerVault MDCU does not launch automatically,
launch it manually.
•In a Windows-based operating system, click
Disk Configuration Utility
.
•In a Linux-based operating system, double-click the
Configuration Utility
10
Start
MD Storage Manager
11
If applicable, activate any premium features purchased with your storage
icon on the desktop.
and discover the array(s).
StartDellModular
Modular Disk
array. If you purchased premium features, see the printed activation card
shipped with your storage array.
Installing PowerVault MD Storage Software29
Page 30
NOTE: The MD Storage Manager installer automatically installs the required
drivers, firmware, and operating system patches/hotfixes to operate your storage
array. These drivers and firmware are also available at support.dell.com. In
addition, see the Support Matrix at support.dell.com/manuals for any additional
settings and/or software required for your specific storage array.
Console Installation
NOTE: Console installation only applies to Linux systems that are not running a
graphical environment.
The autorun script in the root of the resource media detects when there is no
graphical environment running and automatically starts the installer in a
text-based mode. This mode provides the same options as graphical
installation with the exception of the PowerVault MDCU specific options.
The PowerVault MDCU requires a graphical environment to operate.
NOTE: The console mode installer provides the option to install the PowerVault
MDCU.However a graphical environment is required to utilize the PowerVault
MDCU.
Silent Installation
To run silent installation on a Windows system:
1Copy the custom_silent.properties file in the /windows folder of the
installation media or image to a writable location on the host server.
2Modify the custom_silent.properties file to reflect the features, models
and installation options to be used. Then, save the file.
3Once the custom_silent.properties file is revised to reflect your specific
installation, run the following command to begin the silent installation:
To upgrade from a previous version of the MD Storage Manager application,
uninstall the previous version (see "Uninstalling PowerVault MD Storage
Software" on page 53), and then follow the instructions in this chapter to
install the new version.
Installing PowerVault MD Storage Software31
Page 32
32Installing PowerVault MD Storage Software
Page 33
4
Post Installation Tasks
Before using the storage array for the first time, complete a number of initial
configuration tasks in the order shown. These tasks are performed using the
MD Storage Manager (MDSM) software.
NOTE: If Dynamic Host Configuration Protocol (DHCP) is not used, initial configuration
using the management station must be performed on the same phy sical subnet as the
storage array. Additionally, during initial configuration, at least one network adapter
must be configured on the same IP subnet as the storage array’ s default management
port (192.168.128.101 or 192.168.128.102). After initial configuration, the management
ports are configured using MDSM and the management station’ s IP address can be
changed back to the previous settings.
Before You Begin
Before you begin configuring iSCSI, you must fill out the iSCSI configuration
worksheet. Gathering this type of information about your network prior to
starting the configuration steps helps you to complete the process in less time.
iSCSI Configuration Terminolo gy
Table 4-1. Standard Terminology Used in iSCSI Configu ration
TermDefinition
CHAP (Challenge Handshake
Authentication Protocol)
Host or host serverA server connected to the storage array using
Host server portSCSI port on the host server used to connect
An optional security protocol used to control
access to an iSCSI storage system by restricting
use of the iSCSI data ports on both the host
server and storage array. For more information
on the types of CHAP authentication
supported, see "Under standing CHAP
Authentication" on page63.
iSCSI ports.
it to the storage array.
Post Installation Tasks33
Page 34
Table 4-1. Standard Terminology Used in iSCSI Configuration
TermDefinition
iSCSI initiatorThe i S CS I - s p e c if i c s o ftware ins t a l l e d o n t h e
host server that controls communications
between the host server and the storage array.
iSCSI host portThe iSCSI port (two per controller) on the
storage array.
iSNS (Microsoft Internet Storage
Naming Service)
Management stationThe system from which you manage your
Storage arrayThe enclosure containing the storage data
TargetAn iSCSI port on the storage array that
An automated discovery, management and
configuration Storage Naming Service) tool
used by some iSCSI devices.
host server/storage array configuration.
accessed by the host server .
accepts and responds to requests from the
iSCSI initiator installed on the host server.
iSCSI Configuration Worksheet
The iSCSI configuration worksheet helps you plan your configuration.
Recording host server and storage array IP addresses at a single location
enables you to configure your setup faster and more efficiently.
"Guidelines for Configuring Your Network for iSCSI" on page 49 provides general
network setup guidelines for both W indows and Linux environments. It is
recommended that you review these guidelines before completing the worksheet.
34Post Installation Tasks
Page 35
IPv4 Settings
Mutual
CHAP Secret
Target CHAP
Secret
A
B
host server
PowerVault
MD32xxi
192.168.130.101 (In 0 default)
192.168.131.101 (In 1 default)
192.168.132.101 (In 2 default)
192.168.133.101 (In 3 default)
192.168.128.101 (management network port)
192.168.130.102 (In 0 default)
192.168.131.102 (In 1 default)
192.168.132.102 (In 2 default)
192.168.133.102 (In 3 default)
192.168.128.102 (management network port)
If you need additional space for more than one host server, use an additional sheet.
iSCSI port 1
iSCSI port 2
iSCSI port 3
iSCSI port 4
Management port
Management port
The following sections contain step-by-step instructions for configuring
iSCSI on your storage array. However, before beginning, it is important to
understand where each of these steps occur in relation to your host
server/storage array environment.
Table 4-2 below shows each specific iSCSI configuration step and where it
occurs.
Table 4-2. Host Server Vs. Storage Array
This Step is Performed on the Host Server
Using the Microsoft or Linux iSCSI Initiator
3
Perform target discovery from the iSCSI
initiator
6
(Optional) Configure CHAP
authentication on the host server
7
Connect to the storage array from the
host server
This Step is Performed on the Storage
Array Using PowerVault MD Storage
Manager
1
Discover the storage array
2
Configure the iSCSI ports on the
storage array
4
Configure host access
5
(Optional) Configure CHAP
authentication on the storage array
8
(Optional) Set up in-band management
NOTE: It is recommended that you use the PowerVault Modular Disk Configuration Utility
(MDCU) for iSCSI configuration. The PowerVault MDCU wizards guides you through the
configuration steps described above. If you want to perform a manual configuration, see
"Appendix—Manual Configuration of iSCSI" on page55.
38Post Installation Tasks
Page 39
Automatic Configuration Using the Modular Disk Configuration Utility
NOTE: If PowerVault MDCU is not installed, it can be installed from the PowerVault
MD series resource media.
PowerVault MDCU provides a consolidated approach for configuring the iSCSI
network of host servers and iSCSI-based storage arrays using a wizard-driven
interface. This utility also enables the user to configure the iSCSI sessions of the
host server according to the best practices and to achieve load-balanced paths
with the storage array iSCSI host ports.
NOTE: PowerVault MDCU is only applicable to iSCSI-based PowerVault MD3200i
series storage arrays. It does apply to SAS-based PowerVault MD3200 series
storage arrays.
If you select Launch the MDCU after reboot during the installation of the
host software, the utility automatically launches after the next host server
reboot. This utility can also be launched manually.
The utility has a context sensitive online help to guide you through each step
of the wizard.
The PowerVault MDCU performs:
•Storage array configuration
•Host configuration
Storage Array Configuration
Before a host iSCSI initiator and an iSCSI-based storage array can
communicate, they must be configured with information such as which IP
addresses and authentication method to use. Since iSCSI initiators establish
connections with an already configured storage array, the first task is to
configure your storage arrays to make them available for iSCSI initiators.
This utility requires network access to the management ports of the storage arrays
you wish to configure. You must have a properly functioning network
infrastructure before attempting to configure your storage arrays. If your storage
arrays are already configured, you can skip dir ectly to the host configuration.
This configuration task generally involves the following steps:
1
Discover available storage array(s) for configuration.
2
Select a storage array to configure.
3
Set a storage array name and password.
Post Installation Tasks39
Page 40
4
Configure the IP protocols and addresses for the management ports.
5
Configure the IP protocols and addresses for the iSCSI ports.
6
Specify the CHAP authentication method.
7
Apply the settings after reviewing a summary.
8
Repeat the process starting from step 2 to configure additional arrays.
After you have completed configuring your iSCSI-based storage arrays, the
next task is to run this utility on all hosts that need to access the storage
arrays. Depending on your network configuration, your host may be the same
machine you use to manage your storage arrays, or it may be on a completely
separate network.
The option to configure a host is disabled if the machine the utility is running
on does not have an iSCSI initiator or the required driver components
installed. When the option is disabled, the utility also displays an
informational message. If you are running the utility on a host which is not
connected to the iSCSI–based storage array (or which you do not wish to
connect to the array), the informational message can be ignored.
The task generally involves the following steps:
1
Discover available storage array(s) for connection.
2
Select a storage array to connect to.
3
Specify the CHAP secret.
4
Select the iSCSI ports the host's initiator uses to log on.
5
Repeat the process starting from step 2 to connect to additional arrays.
6
Repeat these steps on each host that needs access to the storage array(s).
Before Starting the Configuration Process
Before you start configuring the storage array or host connectivity, it is
recommended that you fill out the iSCSI configuration worksheet to help you
plan your configuration. You may need to use several worksheets depending
on your configuration.
40Post Installation Tasks
Page 41
Keep the following guidelines in mind for the storage array and host
configuration:
•For optimal performance, ensure your network configuration is valid by
consulting the storage array's support matrix.
•If your host has multiple network interfaces, it is recommended that each
network interface uses a separate subnet.
•For redundancy in a dual controller (duplex) configuration, ensure each
host network interface is configured to connect to both storage array
controllers.
•For optimal load balancing, ensure each host network interface that is used
for iSCSI traffic is configured to connect to each storage array controller.
•It is recommended that each host network interface only establishes one
iSCSI session per storage array controller.
NOTE: The utility tries to follow the guidelines for the host connectivity whenever
possible based on the available host network interfaces and their connectivity with
the iSCSI host ports of the storage array.
Configure the Storage Array Using PowerVault MDCU
To configure the iSCSI-based storage array(s) using PowerVault MDCU:
1
Launch the utility (if it is not launched automatically) from the server
with access to the management ports of the storage array(s) to be
configured.
Select the method by which the utility should discover the storage arrays
for configuration and click
Configure Modular Disk Storage Array
Next
.
Post Installation Tasks41
and
Page 42
•Automatic Discovery—Automatic discovery queries the local
sub-network for all iSCSI-based storage arrays and may take several
minutes to complete.
•Manual Discovery—Manual discovery allows you to locate
iSCSI-based storage arrays that are outside of the local sub-network.
Manual discovery requires selecting whether your storage array has a
single controller (simplex) or dual controllers (duplex) and whether to
use IPv4 or IPv6 protocol for communicating with the management
port of the storage array.
5
The next screen presents a list of the iSCSI-based storage arrays that were
discovered based on the discovery process selected in step 3.
If you select
iSCSI-based storage arrays that were discovered in the subnet.
Automatic Discovery
, the screen displays a list of all the
If you select
whose IP addresses were entered. You can add additional arrays to the list
by clicking the
You can also remove the arrays from this list by using the
You can click
LED in order to locate the array physically and ensure it is the array you
intend to configure. Click
before you proceed.
Select the array by clicking the radio button of the corresponding storage
array and then click
6
Enter the name of the storage array and the password.
If you want to set a new password for the array, select
then enter the new password in the
Password
7
Select the IP protocol (IPv4/IPv6) to be used by the management port. Also ,
for each protocol, select whether the configuration of the management port IP
addresses is to be done manually or automatically. F or more information, see
the
online help
Click
the configuration method.
Manual Discovery
Add
button on this screen.
Blink Array
Next
fields. Click
.
Next
to continue after you has finished selecting the protocols and
Next
, then the list contains only the arrays
Remove
to start the blinking of the array’s front panel
Stop Blinking
.
to continue.
to stop the blinking of the array
Set P assword
New Password
and
Confirm New
button.
and
42Post Installation Tasks
Page 43
If you have not selected
Specify Configuration Manually
for any of the
two protocols, then you can skip step 8.
8
If you have selected
Specify Configuration Manually
for any of the two
protocols in the last step, a series of screens showing the backend view
image of the storage array controllers is displayed. Each image contains IP
addresses of management ports of the controllers. Also each image has one
management port highlighted in red.
For IPv4 address of the highlighted port, enter the IP addr ess, subnet
mask and gateway address in the fields shown below the image in order
to modify it.
For IPv6 address of the highlighted port, enter the local IP address,
routable IP, and router IP address in the fields shown below the image in
order to modify it.
Click
Next
to continue through these images to complete the
configuration of all the management ports for the selected protocols.
9
In the
CHAP Configuration
Next
. For more information on CHAP see "Understanding CHAP
screen, select the CHAP method and click
Authentication" on page 63.
10
In the
Summary
screen, review the information that you entered for the
storage array.
Click
Apply
to save the changes to the storage array.
NOTE: To abort the configuration for the storage array and to go back to
select a storage array for configuration, click Cancel Array.
11
On the
configure additional array. Click
12
If you selected
13
If you selected No in step 12, then on the
Configure Additional Arrays
Next
Yes
in the above step, then start again from step 4.
screen, select whether you want to
to continue.
Configure Host Connectivity
screen, select whether you want to configure the connectivity for current
host’s iSCSI initiator. Click
If you selected
14
Click
Finish
No
on the final screen to exit the utility.
above, then you are done with the configuration task.
Next
to continue.
Post Installation Tasks43
Page 44
15
If you selected
Yes
in the last step, then the
Select Storage Array
displayed. Select the storage array that you want to configure for
connectivity to the local host.
NOTE: The storage arrays configured by the utility are marked as
Configuration Complete against their names in the list. This helps you to
identify the arrays that are ready to be configured for host access.
16
In the
Storage Array Login
screen, in the Controller# column, select the
iSCSI host port of the storage array that needs to be configured and it’s IP
address(es). In the
Host Address
column, from drop-down menu list,
select the host IP address that will login to the iSCSI host port of the
storage array.
See "Source Port Selection for iSCSI Host Ports" on page 46’ for more
information about how these host IP addresses are listed in the drop-down
menu and the recommended guidelines for selecting the host IP addresses.
Click
Next
to continue to enter the log in information for another
controller or Click
17
In the
Connect to Additional Arrays
Apply
to save the log in information.
screen, select whether you want to
connect to another storage array or not.
If you want to connect to another storage array, repeat the above steps
starting from step 15.
screen is
If you do not want to connect to additional arrays, then click
final screen to exit the utility.
44Post Installation Tasks
Finish
on the
Page 45
Configure the Host Connectivity Using PowerVault MDCU
To configure the host connectivity for an iSCSI-based storage array(s)
using PowerVault MDCU:
1
Launch the utility (if it is not launched automatically) from the server
which needs to be configured for access to the iSCSI-based storage
array(s). This server must have access to the array either using the array’s
management ports or using the array’s iSCSI host ports.
See step 1 in "Configure the Storage Array Using PowerVault MDCU" on
page 41 for the instructions on how to launch the utility.
Click
Next
to continue.
2
In the
Configuration Task
NOTE: This task is not supported or is disabled if the MDSM agent is not
installed on the host where you are running the utility. The agent is typically
not installed on the Windows client systems such as Windows XP.
3
In the
Discovery Method
screen, select
Configure Host
and click
screen, select one of the discovery methods.
If the host has access to the management ports of the PowerVault MD
storage array(s), then select
click
Next
.
Discover via Management Port
method and
If the host does not have the access to the management ports of the array,
then select the
has access to the iSCSI host ports of the storage array) and click
Discover via iSCSI Port
method (assuming that the host
Next
Continue to step 5.
Next
.
.
4
Follow the instructions in step 3 and step 4 of "Configure the Storage
Array Using PowerVault MDCU" on page 41 to select the storage array
that needs to be configured for connectivity with the host. Go to step6.
5
In the
iSCSI Port IP Address
screen, enter the IPv4 IP address of any one
of the iSCSI host port of the array that the host can connect to or enter the
IPv6 local address of the any of the iSCSI host port. Click
Next
to
continue.
6
In the
CHAP Configuration
screen, enter the CHAP secret if you have
configured a CHAP secret for the storage array.
Post Installation Tasks45
Page 46
7
In the
Storage Array Login
screen, in the Controller# column, select the
iSCSI host port of the storage array that needs to be configured and its IP
address(es). In the
Host Address
column, from drop-down menu list, select
the host IP address that logs into the iSCSI host port of the storage array.
See "Source Port Selection for iSCSI Host Ports" on page 46 for more
details about how these host IP addresses are listed in the drop-down
menu and the recommended guidelines for selecting the host IP addresses.
Click
Next
to continue to enter the login information for another
controller or Click
8
In the
Connect to Additional Arrays
Apply
to commit the array login information.
screen, select whether you want to
connect to another storage array or not.
If you want to connect to another storage array, repeat the above steps
starting from step 4 or step 5 depending on your last selection.
If you do not want to connect to additional arrays, then click
Finish
on the
final screen to exit the utility.
Source Port Selection for iSCSI Host Ports
In order to establish data communication between a host and an iSCSI-based
storage array, the iSCSI initiator on the host must be configured to establish
iSCSI sessions to the iSCSI host ports of the storage array. The iSCSI port login
screen allows you to specify the host and storage array IP addresses the iSCSI
initiator uses to establish these iSCSI sessions.
Port Login Selection
Each iSCSI port for each controller in the storage array is presented with a list
of host IP addresses through which the iSCSI initiator is able to login. The
host IP addresses are the source IP addresses and the iSCSI port is the target.
Each list contains only the host IP addresses that are able to communicate
with the associated iSCSI port. If none of the host IP addresses are able to
communicate with an iSCSI port, Not Available is the only option shown for
that iSCSI port. If none of the host IP addresses are able to communicate
with any iSCSI ports of either storage array controller, the host configuration
option is aborted for that storage array.
NOTE: The behavior described in the preceding paragraph does not apply to
Microsoft Windows Server 2003.
46Post Installation Tasks
Page 47
For Microsoft Windows Server 2003, each list contains all available host IP
addresses regardless of whether or not the address is able to communicate
with the associated iSCSI port. You must select the appropriate host IP
addresses for each iSCSI port.
Automatic Selection
NOTE: The contents in this section do not apply to Microsoft Windows Server 2003.
The utility attempts to automatically find and select the best possible
configuration of host IP address(es) and storage array iSCSI ports for optimal
performance and redundancy.
This automatic selection attempts to ensure that a host IP address (up to two
IP addresses for PowerVault MD3000i storage arrays and up to four IP
addresses for PowerVault MD3200i and MD3220i storage arrays) establishes
an iSCSI session with each storage array controller and that the host IP
address is logged into a maximum of one iSCSI port per controller.
Configuration in this manner ensures redundancy and load balancing among
the multiple host IP addresses (NICs).
The Do Not Connect option may be selected as the default option if the
utility recommends not to connect to the iSCSI port. Also, even if the best
recommended configuration is presented (whenever possible), you can still
override this configuration by selecting the other host IP addresses from the
drop-down list.
Suboptimal Configuration Warnings
In the following cases, a warning is displayed, that you must confirm, to
continue:
•The host IP addresses are selected in such a way that any host IP address
establishes an iSCSI session with only one storage array controller in a dual
controller (duplex) configuration.
•The host IP addresses are selected in such a way that a host IP address
establishes two or more iSCSI sessions with the same storage array
controller.
Post Installation Tasks47
Page 48
Post Connection Establishment Steps
After iSCSI connectivity is established between the host server(s) and the
storage array, you can create virtual disks on the storage array using MDSM
and these virtual disks can be utilized by the host server(s). For more
information about storage planning and using MDSM, see the Owner’s Manual at support.dell.com/manuals.
48Post Installation Tasks
Page 49
5
Guidelines for Configuring Your
Network for iSCSI
This section provides general guidelines for setting up your network
environment and IP addresses for use with the iSCSI ports on your host server
and storage array. Your specific network environment may require different or
additional steps than shown here, so make sure you consult with your system
administrator before performing this setup.
Microsoft Windows Host Setup
To set up a Windows host network, you must configure the IP address and
netmask of each iSCSI port connected to the storage array. The specific steps
depend on whether you are using a Dynamic Host Configuration Protocol
(DHCP) server, static IP addressing, Domain Name System (DNS) server, or
Windows Internet Name Service (WINS) server.
NOTE: The server IP addresses must be configured for network communication to
the same IP subnet as the storage array management and iSCSI ports.
If you are using a DHCP server:
1
In the
Control Panel
Sharing Center
2
Right-click the network connection you want to configure and
select
Properties
3
On the
(for all other connections), select
click
4
Select
If you are using static IP addressing:
1
In the
Center
2
Right-click the network connection you want to configure and select
Properties
General
Properties
Obtain an IP address automatically
Control P anel
and then click
.
, select
and then click
.
tab (for a local area connection) or the
.
, select
Network connections
Manage network connections
Internet Protocol (TCP/IP)
Network connections
Manage network connections
or
, then click OK.
or
Network and
.
Networking
Network and Sharing
.
tab
, and then
Guidelines for Configuring Your Network for iSCSI49
Page 50
3
On the
(for all other connections), select
click
4
Select
General
Properties
tab (for a local area connection) or the
.
Use the following IP address
Networking
Internet Protocol (TCP/IP)
, and then
and enter the IP address, subnet mask,
and default gateway addresses.
If you are using a DNS server:
1
In the
Control P anel
Center
and then click
2
Right-click the network connection you want to configure and select
Properties
3
On the
.
General
(for all other connections), select
click
Properties
4
Select
Obtain DNS server address automatically
and alternate DNS server IP addresses and click
, select
Network connections
Manage network connections
or
Network and Sharing
.
tab (for a local area connection) or the
Internet Protocol (TCP/IP)
.
or enter the preferred
OK
.
Networking
, and then
If you are using a WINS server:
NOTE: If you are using a DHCP server to allocate WINS server IP addresses, you
do not need to add WINS server addresses.
1
In the
Control Panel
2
Right-click the network connection you want to configure and select
Properties
3
On the
.
General
(for all other connections), select
click
Properties
4
Select
Advanced
5
In the
TCP/IP WINS server
server and click
6
T o enable use of the Lmhosts file to r esolve remote NetBIOS names, select
Enable LMHOSTS lookup
, select
Network connections
.
tab (for a local area connection) or the
Internet Protocol (TCP/IP)
.
WINS
tab and click
Add
.
window, type the IP address of the WINS
Add
.
.
Networking
, and then
tab
tab
tab
50Guidelines for Configuring Your Network for iSCSI
Page 51
7
To specify the location of the file that you want to import into the
Lmhosts file, select
Open
dialog box.
8
Enable or disable NetBIOS over TCP/IP.
If using Microsoft Windows Server 2008 Core Version, use the netsh
interface command to configure the iSCSI ports on the host server.
Import LMHOSTS
and then select the file in the
Linux Host Setup
To set up a Linux host network, you must configure the IP address and
netmask of each iSCSI port connected to the storage array. The specific steps
depend on whether you are configuring TCP/IP using DHCP or configuring
TCP/IP using a static IP address.
NOTE: The server IP addresses must be configured for network communication to
the same IP subnet as the storage array management and iSCSI ports.
If you are using DHCP (root users only):
1
Edit the
NETWORKING=yes HOSTNAME=mymachine.mycompany.com
2
Edit the configuration file for the connection you want to configure, either
Restart network services using the following command:
/etc/init.d/network restart
etc/sysconfig/network
file as follows:
(for Red Hat Enterprise Linux)
52Guidelines for Configuring Your Network for iSCSI
Page 53
6
Uninstalling PowerVault MD
Storage Software
Uninstalling Dell PowerVault MD Storage
Software From Windows
Use the Change/Remove P rogram feature to uninstall Dell PowerVault
Modular Disk Storage Software from Microsoft Windows operating systems
other than Microsoft Windows Server 2008:
1
From the
2
Select
3
Click
The
4
Follow the instructions on screen.
5
Select
Use the following procedure to uninstall Modular Disk Storage software from
Windows Server 2008 GUI versions:
1
From the
2
Select
3
Click
The
Control Panel,
Dell MD32
Change/Remove
Uninstall Complete
Yes
to restart the system, and then click
Control Panel
MD Storage Software
Uninstall/Change
Uninstall Complete
double-click
xxi Storage Software
.
window appears.
, double-click
from the list of programs.
.
window appears.
Add or Remove Programs
from the list of programs.
Done
.
Programs and Features
.
.
4
Select
Yes
to restart the system, then click Done.
Use the following procedure to uninstall Modular Disk Storage Software on
Windows Server 2008 Core versions:
NOTE: By default, Dell PowerVault MD Storage Manager is installed in the
\Program Files\Dell\MD Storage Software directory. If another directory was used
during installation, navigate to that directory before beginning the uninstallation
procedure.
2
From the installation directory, type the following command and press
<Enter>:
Uninstall Dell MD Storage Software
3
From the
screen.
4
Select
Uninstall
Yes
to restart the system, then click
window, click
Next
and follow the instructions on the
Done
.
Uninstalling PowerVault MD Storage Software
From Linux
1
By default, PowerVault MD Storage Manager is installed in the
directory. If another directory was used during installation, navigate to that
directory before beginning the uninstallation procedure.
2
From the installation directory, open the
Software
3
Run the file
4
From the
screen.
While the software is uninstalling, the
When the uninstall procedure is complete, the
window
directory.
Uninstall Dell MD Storage
Uninstall
is displayed.
window, click
Uninstall Dell MD Storage
.
Next
, and follow the instructions on the
Uninstall
window is displayed.
Uninstall Complete
5
Click
Done
.
54Uninstalling PowerVault MD Storage Software
Page 55
A
Appendix—Manual Configuration
of iSCSI
The following sections contain step-by-step instructions for configuring
iSCSI on your storage array. However, before beginning, it is important to
understand where each of these steps occur in relation to your host server or
storage array environment.
Table A-1 below shows each iSCSI configuration step and where it occurs.
Table A-1. Host Server Vs. Storage Array
This Step is Performed on the Host Server
Using the Microsoft or Linux iSCSI Initiator
3
Perform tar get discovery fro m the iSCSI
initiator
6
(Optional) Configure CHAP
authentication on the host server
7
Connect to the storage array from the
host server
This Step is Performed on the Storage
Array Using PowerVault MD Storage
Manager
1
Discover the storage array
2
Configure the iSCSI ports on the
storage array
4
Configure host access
5
(Optional) Configure CHAP
authentication on the st or age array
8
(Optional) Set up in-band management
Appendix—Manual Configuration of iSCSI55
Page 56
Step 1: Discover the Storage Array (Out-of-band
Management Only)
Default Management Port Settings
By default, the storage array management ports are set to Dynamic Host
Configuration Protocol (DHCP). If the controllers on your storage array are
unable to get IP configuration from a DHCP server, it times out after 10
seconds and falls back to a default static IP address. The default IP
configuration is:
NOTE: If DHCP is not used, initial configuration using the management station must
be performed on the same phy s ical subnet as the storage array. Additionally, during
initial configuration, at least one network adapter must be configured on the same
IP subnet as the storage array’s default management port (192.168.128.101 or
192.168.128.102). After initial configuration (management ports are configured using
PowerVault MD Storage Manager), the management station’s IP address can be
changed back to its previous settings.
NOTE: This procedure applies to out-of-band management only. If you choose to
set up in-band management, you must complete this step and then see "Step 8:
(Optional) Set Up In-Band Management" on page74.
You can discover the storage array either automatical ly or manually. Select
one and complete the steps below.
56Appendix—Manual Configuration of iSCSI
Page 57
Automatic Storage Array Discovery
1
Launch MD Storage Manager (MDSM).
If this is the first storage array to be set up, the
window is displayed.
2
Select
Automatic
It may take several minutes for the discovery process to complete. Closing
the discovery status window before the discovery process completes
cancels the discovery process.
and click OK.
Add New Storage Array
After discovery is complete, a confirmation screen is displayed. Click
to close the screen.
Manual Storage Array Discovery
1
Launch MDSM.
If this is the first storage array to be set up, the
window is displayed.
2
Select
Manual
3
Select Out-of-band management and enter the host server name(s) or IP
address(es) of the iSCSI storage array controller.
4
Click
Add
Out-of-band management should now be successfully configured.
After discovery is complete, a confirmation screen is displayed. Click
to close the screen.
and click OK.
.
Add New Storage Array
Setting Up the Array
1
When discovery is complete, the name of the first storage array found is
displayed under the
2
The default name for the newly discovered storage array is
another name is displayed, click the down arrow next to that name and
select
Unnamed
3
Click the
installation tasks. For more information about each task, see the
Manual
Initial Setup Tasks
. Perform these tasks in the order shown in Table 4-3.
Summary
in the drop-down list.
tab in MDSM.
option to see links to the remaining post-
Unnamed
Close
Close
. If
Owner’s
Appendix—Manual Configuration of iSCSI57
Page 58
NOTE: Before configuring the storage array, check the status icons on the
Summary tab to ensure that the enclosures in the storage array are in an Optimal
status. For more information on the status icons, see the Owner’s Manual at
support.dell.com/manuals.
Table A-2. Initial Setup Tasks Dialog Box
TaskPurpose
Rename the storage arrayTo provide a more meaningful name than the
software-assigned label, Unnamed.
Set a storage array passwordT o restrict un authorized access. MDSM may ask
for a password before changing the
configuration or performing a destructive
operation.
Set up alert notifications
Set up e-mail alerts
Set up SNMP alerts
Configure a storage arrayTo create virtual disks and map them to hosts.
To notify individuals (by e-mail) and/or storage
enterprise management consoles, such as Dell
Management Console, (by SNMP) when a
storage array component degrades or fails, or an
adverse environmental condition occurs.
Step 2: Configure the iSCSI Ports on the Storage
Array
By default, the iSCSI ports on the storage array are set to the following IPv4
settings:
Controller 0, Port 0: IP: 192.168.130.101 Subnet Mask:
To configure the iSCSI ports on the storage array:
1
From MDSM navigate to the
Ethernet management ports
2
Configure the iSCSI ports on the storage array.
NOTE: Using static IPv4 addressing is recommended, although DHCP is supported.
Setup
tab on the AMW. Click
and then select
configure
Configure iSCSI Host Ports
The following settings are available (depending on your specific
configuration) by clicking the
Advanced
button:
•Virtual LAN (VLAN) support—A VLAN is a network of different
systems that behave as if they are connected to the same segments of a
local area network (LAN) and are supported by the same switches and
routers. When configured as a VLAN, a device can be moved to
another location without being reconfigured. To use VLAN on your
storage array, obtain the VLAN ID from your network administrator
and enter it here.
•Ethernet priority—This parameter is set to determine a network
access priority.
•TCP listening port—The port number on the storage array listens for
iSCSI logins from host server iSCSI initiators.
.
NOTE: The TCP listening port for the iSNS server is the port number the
storage array controller uses to connect to an iSNS server. This allows the
iSNS server to register the iSCSI target and portals of the storage array so
that the host server initiators can identify them.
•Jumbo frames—Jumbo Ethernet frames are created when the
maximum transmission units (MTUs) are larger than 1500 bytes per
frame. This setting is adjustable port-by-port.
Appendix—Manual Configuration of iSCSI59
Page 60
3
To enable ICMP PING responses for all ports, select
responses.
4
Click
OK
when all iSCSI storage array port configurations are complete.
5
T est the connection by performing a ping command on each iSCSI storage
array port.
Enable ICMP PING
Step 3: Perform Target Discovery From the iSCSI
Initiator
This step identifies the iSCSI ports on the storage array to the host server.
Select the set of steps in one of the following sections (Microsoft Windows or
Linux) that corresponds to your operating system.
If you are using Microsoft Windows Server 2003 or Windows Server 2008 GUI version:
1
Click
StartProgramsMicrosoft iSCSI Initiator
Programs
2
Click the
3
Under
the iSCSI port on the storage array.
4
If the iSCSI storage array uses a custom TCP port, change the
number. The default is 3260.
5
Click
•
•
•
•
Administrative ToolsiSCSI Initiator
Discovery
Target Portals
Advanced
Local Adapter
Source IP
with.
Data Digest and Header Digest
digest of data or header information be compiled during transmission
to assist in troubleshooting.
CHAP logon information
enter CHAP information at this point, unless you are adding the
storage array to a SAN that has target CHAP already configured.
tab.
, click
Add
and enter the IP address or DNS name of
and set the following values on the
—Must be set to Microsoft iSCSI Initiator.
—The source IP address of the host you want to connect
—Optionally, you can specify that a
—Leave this option unselected and do not
or click
.
General
StartAll
Port
tab:
NOTE: IPSec is not supported.
60Appendix—Manual Configuration of iSCSI
Page 61
6
Click OK to exit the
Target Portals
7
To exit the
Discovery
screen.
Advanced
menu and click OK again to exit the
tab, click OK.
Add
If you plan to configure CHAP authentication, do not perform discovery on
more than one iSCSI port at this point. Go to "Step 4: Configure Host
Access" on page 62.
If you do not plan to configure CHAP authentication, repeat step1 thorough
step 6 for all iSCSI ports on the storage array.
If you are using Windows Server 2008 Core Version:
1
Set the iSCSI initiator service to start automatically:
If you are using Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6,
SUSE Linux Enterprise Server 10, or SUSE Linux Enterprise Server 11:
Configuration of the iSCSI initiator for Red Hat Enterprise Linux 5 and
SUSE Linux Enterprise Server 10 SP1 distributions is done by modifying the
/etc/iscsi/iscsid.conf file, which is installed by default when you install
MDSM. You can edit the file directly, or replace t he defaul t file wi th a sampl e
file included on the PowerVault MD series resource media.
To use the sample file included on the media:
1
Save the default
/etc/iscsi/iscsid.conf
file by naming it to another name of
your choice.
2
Copy the appropriate sample file from
/etc/iscsi/iscsid.conf
3
Rename the sample file to
4
Edit the following entries in the
a
Edit or verify that the
b
Edit or verify that the
.
iscsid.conf
node.startup = manual
node.startup = automatic
/linux/etc
on the media to
.
/etc/iscsi/iscsid.conf
file:
line is disabled.
line is
enabled. This enables automatic startup of the service at boot time.
Appendix—Manual Configuration of iSCSI61
Page 62
c
Verify that the following time-out value is set to 30:
node.session.timeo.replacement_timeout = 30
d
Save and close the
5
From the console, restart the iSCSI service with the following command:
service iscsi start
6
Verify that the iSCSI service is running during boot using the following
command from the console:
chkconfig iscsi on
7
To display the available iSCSI targets at the specified IP address, use the
following command:
iscsiadm –m discovery –t st -p
<IP_address_of_iSCSI_port>
8
After target discovery, use the following command to manually log in:
iscsiadm -m node –l
This log in is performed automatically at startup if automatic startup is
enabled.
9
Manually log out of the session using the following command:
This step specifies which host servers access virtual disks on the storage array.
You should perform this step:
•Before mapping virtual disks to host servers
•Any time you connect new host servers to the storage array
1
Launch MDSM.
2
Navigate to the AMW and click
3
At
Enter host name
This can be an informal name, not necessarily a name used to identify the
host server to the network.
4
Select a method for adding the host port identifier.
62Appendix—Manual Configuration of iSCSI
, enter the host server for virtual disk mapping.
Manually define hosts
.
Page 63
5
Select the host type.
6
Select whether or not the host server will be part of a host server group that
shares access to the same virtual disks as other host servers. Select
if the host is part of a Microsoft cluster.
7
Click
Next
.
8
Specify if this host will be part of a host group.
9
Click
Finish
.
Yes
only
Understanding CHAP Authentication
What is CHAP?
Challenge Handshake Authentication Protocol (CHAP) is an optional iSCSI
authentication method where the storage array (target) authenticates iSCSI
initiators on the host server. Two types of CHAP are supported
•Target CHAP
•Mutual CHAP
Target CHAP
In target CHAP, the storage array authenticates all requests for access issued
by the iSCSI initiator(s) on the host server using a CHAP secret. To set up
target CHAP authentication, you must enter a CHAP secret on the storage
array, then configure each iSCSI initiator on the host server to send that
secret each time it attempts to access the storage array.
Mutual CHAP
In addition to setting up target CHAP, you can set up mutual CHAP in which
both the storage array and the iSCSI initiator authenticate each other . To set up
mutual CHAP, configure the iSCSI initiator with a CHAP secret that the
storage array must send to the host sever in order to establish a connection. In
this two-way authentication process, both the host server and the storage array
send information that the other must validate before a connection is allowed.
Appendix—Manual Configuration of iSCSI63
Page 64
CHAP is an optional feature and is not required to use iSCSI. However, if you
do not configure CHAP authentication, any host server connected to the same
IP network as the storage array can read from and write to the storage array.
NOTE: When using CHAP authentication, you should configure it on both the
storage array (using MDSM) and the host server (using the iSCSI initiator) before
preparing virtual disks to receive data. If you prepare disks to receive data before
you configure CHAP authentication, you lose visibility to the disks once CHAP
is configured.
CHAP Definitions
To summariz e the differences between target CHAP and mutual CHAP
authentication, see Table A-3.
Table A-3. CHAP Types Defined
CHAP TypeDescription
Target CHAPSets up accounts that iSCSI initiators use to connect to the
target storage array. The target storage array then authenticates
the iSCSI initiator.
Mutual CHAPApplied in addition to target CHAP, mutual CHAP sets up an
account that a target storage array uses to connect to an iSCSI
initiator. The iSCSI initiator then authenticates the target.
Step 5: Configure CHAP Authentication on the
Storage Array (Optional)
If you are configuring CHAP authentication of any kind (either tar get-only or
target and mutual), you must complete this step and "Step 5: Configure
CHAP Authentication on the Storage Arra y (O ptional)" on page 64.
If you are not configuring any type of CHAP, skip these steps and go to "Step
7: Connect to the Target Storage Array From the Host Server" on page70.
NOTE: If you choose to configure mutual CHAP authentication, you must first
configure target CHAP.
In terms of iSCSI configuration, the term target always refers to the storage array.
64Appendix—Manual Configuration of iSCSI
Page 65
Configuring Target CHAP Authentication on the Storage Array
1
From MDSM, click the
Authentication
.
Select one of the CHAP settings described in Table A-4.
Table A-4. CHAP Setting
OptionDescription
NoneThis is the default selection. If None is the only selection, the
storage array allows an iSCSI initiator to log on without
supplying any type of CHAP authentication.
None and CHAP The storage array allows an iSCSI initiator to log on with or
without CHAP authentication.
CHAPIf CHAP is selected and None is deselected, the storage array
requires CHAP authentication before allowing access.
2
To configure a CHAP secret, select
3
Enter the
in
Confirm Target CHAP Secret
Target CHAP Secret (or Generate Random Secret)
Although the storage array allows sizes from 12 to 57 characters, many
initiators only support CHAP secret sizes up to 16 characters (128-bit).
NOTE: A CHAP secret is not retrievable after it is entered. Ensure that you
record the secret in an accessible place. If Generate Random Secret is used,
copy and paste the secret into a text file for future reference since the same
CHAP secret is used to authenticate any new host servers you may add to the
storage array. If you forget this CHAP secret, you must disconnect all existing
hosts attached to the storage array and repeat the steps in this chapter to
re-add them.
4
Click OK.
iSCSI
tab and then click
CHAP
and click
Change Target
and select
OK
.
CHAP Secret
. Confirm it
.
Appendix—Manual Configuration of iSCSI65
Page 66
Configuring Mutual CHAP Authentication on the Storage Array
The initiator secret must be unique for each host server that connects to the
storage array and must not be the same as the target CHAP secret.
Change the initiator authentication settings in the Change Target Authentication window. Use these options to change the settings:
•
None
—Select
None
, any initiator can access this target. Use this option only if you do
not require secur e data . How ever, you can select both
the same time.
•
CHAP
—Select
access the target to authenticate using CHAP. Define the CHAP secret
only if you want to use mutual CHAP authentication. If you select
and if no CHAP target secret is defined, an error message is displayed.
Click
CHAP Secret
window to define the CHAP secrets.
NOTE: To remove a CHAP secret, you must delete the host initiator and re-add it.
None
if you permit no initiator authentication. If you select
None
and
CHAP
if you want to enable an initiator that tries to
to view the
Enter CHAP Secre
t windows. Use this
CHAP
CHAP
at
Step 6: Configure CHAP Authentication on the
Host Server (Optional)
If you configured CHAP authentication in "Step 5: Configure CHAP
Authentication on the Storage Array (Optional)" on page 64, complete the
following steps. If not, skip to "Step 7: Connect to the Target Storage Array
From the Host Server" on page 70.
Select the set of steps in one of the following sections (Windows or Linux)
that corresponds to your operating system.
If you are using Windows Server 2008 GUI version:
1
Click
Start
Programs
2
If you are not using mutual CHAP authentication, go to the step 4.
3
If you are using mutual CHAP authentication, click the
select
entered for the storage array
4
Click the
Programs
Administrative Tools
Secret
. At
Enter a secure secret
Discovery
tab.
Microsoft iSCSI Initiator
iSCSI Initiator
, enter the mutual CHAP secret you
or click
.
General
Start
tab and
All
,
66Appendix—Manual Configuration of iSCSI
Page 67
5
Under
Target Portals
array and click
, select the IP address of the iSCSI port on the storage
Remove
.
The iSCSI port you configured on the storage array during target
discovery disappears.
6
Under
Target Portals
, click
Add
and re-enter the IP address or DNS name
of the iSCSI port on the storage array (removed above).
7
Click
Advanced
and set the following values on the
General
tab:
•Local Adapter—Should always be set to Microsoft iSCSI Initiator.
•Source IP—The source IP address of the host you want to connect
with.
•Data Digest and Header Digest—Optionally, you can specify that a
digest of data or header information be compiled during transmission
to assist in troubleshooting.
•CHAP logon information—Enter the target CHAP authentication
user name and secret you entered (for the host server) on the
storage array.
•Perform mutual authentication—If mutual CHAP authentication is
configured, select this option.
NOTE: IPSec is not supported.
8
Click OK.
If you require a discovery session failover, repeat step 5 and step 6 (in this
step) for all iSCSI ports on the storage array. Otherwise, single-host port
configuration is sufficient.
NOTE: If the connection fails, ensure that all IP addresses are entered correctly.
Mistyped IP addresses result in connection problems.
If you are using Windows Server 2008 Core version:
1
Set the iSCSI initiator services to start automatically (if not already set):
sc \\<server_name> config msiscsi start= auto
2
Start the iSCSI service (if necessary):
3
If you are not using mutual CHAP authentication, go to step 5.
4
Enter the mutual CHAP secret you entered for the storage array:
iscsicli CHAPSecret <secret>
Appendix—Manual Configuration of iSCSI67
sc start msiscsi
Page 68
5
Remove the target portal that you configured on the storage array during
target discovery:
where, [CHAP_username] is the initiator name and [CHAP_password] is
the target CHAP secret.
If you require a discovery session failover, repeat step 5 for all iSCSI ports
on the storage array. Otherwise, single-host port configuration is sufficient.
If you are using Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6,
SUSE Linux Enterprise Server 10, or SUSE Linux Enterprise Server 11:
1
To enable CHAP (optional), the following line needs to be enabled in your
/etc/iscsi/iscsid.conf
node.session.auth.authmethod = CHAP
2
To set a user name and password for CHAP authentication of the initiator
by the target(s), edit the following lines:
If you are using Mutual CHAP authentication, you can set the user name
and password for CHAP authentication of the target(s) by the initiator by
editing the following lines:
To set the user name and password for discovery session CHAP
authentication of the target(s) by the initiator for Mutual CHAP, edit the
following lines:
If you are using SUSE Linux Enterprise Server SP3 using the GUI:
1
Click
DesktopYaSTiSCSI Initiator
2
Click
Service Start
3
Select
Discovered Targets
4
Enter the IP address of the port.
5
Click
Next
.
6
Select any target that is not logged in and click
7
Select one:
•If you are not using CHAP authentication, select
Go to step 8.
or
•If you are using CHAP authentication, enter the CHAP user name and
password. To enable Mutual CHAP, select and enter the Mutual
CHAP user name and password.
8
Repeat step 7 for each target until at least one connection is logged in for
each controller.
9
Go to
Connected Targets
10
Verify that the targets are connected and displays a status of
, then select
, then select
.
When Booting
.
.
Discovery
.
Log in
.
No Authentication
true
.
.
Step 7: Connect to the Target Storage Array From
the Host Server
If you are using Windows Server 2008 GUI:
Click
1
2
70Appendix—Manual Configuration of iSCSI
Start
Programs
Click the
If previous target discovery was successful, the iqn of the storage array
should be displayed under Targets.
Programs
Administrative Tools
Targets
tab.
Microsoft iSCSI Initiator
iSCSI Initiator
or click
.
Start
All
Page 71
3
Click
4
5
6
Select
Select
Click
Log On
Advanced
.
Automatically restore this connection when the system boots
Enable multi-path
and configure the following settings under the
.
General
tab:
•
Local Adapter
•
Source IP
—Must be set to
Microsoft iSCSI Initiator
.
—The source IP address of the host server you want to
connect from.
•
Target Portal
—Select the iSCSI port on the storage array controller
that you want to connect to.
•
Data Digest and Header Digest
—Optionally, you can specify that a
digest of data or header information be compiled during transmission
to assist in troubleshooting.
•
CHAP logon information
—If CHAP authentication is required,
select this option and enter the Target secret.
•
Perform mutual authentication
—If mutual CHAP authentication is
configured, select this option.
NOTE: IPSec is not supported.
7
Click OK.
To support storage array controller failover, the host server must be
connected to at least one iSCSI port on each controller. Repeat step3
through step 8 for each iSCSI port on the storage array that you want to
establish as failover targets. The
Target Portal
address is different for each
port you connected to.
.
NOTE: To enable the higher throughput of multipathing I/O, the host server
must connect to both iSCSI ports on each controller, ideally from separate
host-side NICs. Repeat step 3 through step7 for each iSCSI port on each
controller. If using a duplex PowerVault MD32xxi configuration, then LUNs
should also be balanced between the controllers.
The
Status
field on the
8
Click OK to close the Microsoft iSCSI initiator.
NOTE: PowerVault MD32xxi supports only round robin load-balancing
policies.
Targets
tab should now display as
Appendix—Manual Configuration of iSCSI71
Connected
.
Page 72
If you are using Windows Server 2008 Core Version:
1
Set the iSCSI initiator services to start automatically (if not already set):
To view ac t ive sessions to the target, run the following command:
iscsicli SessionList
To support storage array controller failover, the host server must be connected
to at least one iSCSI port on each controller. Repeatstep 3 for each iSCSI port
on the storage array that you want to establish as a failover target. The Target_ Portal_Address is different for each port you connect to.
PersistentLoginTarget does not initiate a login to the target until after the
system is rebooted. To establish immediate lo gin to the target, substitute
LoginTarget for PersistentLoginTarget.
:NOTE: See the Microsoft iSCSI Software Initiator 2.x User’s Guide for more
information about the commands used in the previous steps. For more information
about Windows Server 2008 Server Core, see the Microsoft Developers Network
(MSDN) at microsoft.com.
If you are using a Linux Server:
In MDSM, the Configure iSCSI Host P orts displays the status of each iSCSI
port you attempt to connect and the configuration state of all IP addresses. If
either displays Disconnected or Unconfigured, respectively, check the
following and repeat the iSCSI configuration steps:
•Are all cables securely attached to each port on the host server and storage
array?
•Is TCP/IP correctly configured on all target host ports?
•Is CHAP set up correctly on both the host server and the storage array?
To review optimal network setup and configuration settings, see "Guidelines
for Configuring Your Network for iSCSI" on page 49.
Appendix—Manual Configuration of iSCSI73
Page 74
Step 8: (Optional) Set Up In-Band Management
Out-of-band management (see "Step 1: Discover the Storage Array (Out-ofband Management Only)" on page 56) is the recommended method for
managing the storage array. However, to optionally set up in-band
management, use the steps shown below.
The default iSCSI host port IPv4 addresses are shown below for reference:
Controller 0, Port 0: IP: 192.168.130.101 Controller 0, Port 1: IP:
192.168.131.101
Controller 0, Port 0: IP: 192.168.132.101 Controller 0, Port 1: IP:
192.168.133.101
Controller 1, Port 0: IP: 192.168.130.102 Controller 1, Port 1: IP:
192.168.131.102
Controller 1, Port 0: IP: 192.168.132.102 Controller 1, Port 1: IP:
192.168.133.102
NOTE: The management station you are using must be configured for network
communication to the same IP subnet as the PowerVault MD32xxi host ports.
1
Establish an iSCSI session to the PowerVault MD3200i RAID storage array .
2
Restart the
3
Launch MDSM.
If this is the first storage array to be set up for management, the
Storage Array
SMagent
service.
window is displayed. Otherwise, click
New
Add New
.
4
Select
Manual
5
Select In-band management and enter the host server name(s) or IP
address(es) of the host server that is running the PowerVault MD Storage
Manager software.
6
Click
Add
In-band management should now be successfully configured.
74Appendix—Manual Configuration of iSCSI
and click OK.
.
Page 75
B
Appendix—Using Internet Storage
Naming Service
Internet Storage Naming Service (iSNS) server, supported only on Microsoft
Windows iSCSI environments, el imina tes the need to manually configure
each individual storage array with a specific list of initiators and target IP
addresses. Instead, iSNS automatically discovers, manages, and configures all
iSCSI devices in your environment.
For more information on iSNS, including installation and configuration, see
microsoft.com.
Appendix—Using Internet Storage Naming Service 75
Page 76
76Appendix—Using Internet Storage Naming Service
Page 77
C
Appendix—Load Balancing
Load Balance Policy
Multi-path drivers select the I/O path to a virtual disk through a specific RAID
controller module. When the multi-path driver receives a new I/O to process,
the driver tries to find a path to the current RAID controller module that owns
the virtual disk. If the path to the current RAID controller module that owns
the virtual disk cannot be found, the multi-path driver migrates the virtual disk
ownership to the secondary RAID controller module. When multiple paths to
the RAID controller module that owns the virtual disk exist, you can choose a
load balance policy to determine which path is used to process I/O . Multiple
options for setting the load balance policies let you optimize I/O performance
when mixed host interfaces are configur ed.
You can choose one of the following load balance policies to optimize I/O
performance:
•Round robin with subset
•Least queue depth with subset
•Least path weight with subset (Windows operating systems only)
Round Robin With Subset
The round robin with subset I/O load balance policy routes I/O requests, in
rotation, to each available data path to the RAID controller module that owns
the virtual disks. This policy treats all paths to the RAID controller module that
owns the virtual disk equally for I/O activity. P aths to the secondary RAID
controller module are ignored until ownership changes. The basic assumption
for the round-robin policy is that the data paths are equal. With mixed host
support, the data paths might have different bandwidt hs or different data
transfer speeds.
Appendix—Load Balancing77
Page 78
Least Queue Depth With Subset
The least queue depth with subset policy is also known as the least I/Os or
least requests policy. This policy routes the next I/O request to a data path
that has the least outstanding I/O requests queued. For this policy, an I/O
request is simply a command in the queue. The type of command or the
number of blocks that are associated with the command are not considered.
The least queue depth with subset policy treats large block requests and small
block requests equally. The data path selected is one of the paths in the path
group of the RAID controller module that owns the virtual disk.
Least Path Weight With Subset
The least path weight with subset policy assigns a weight factor to each data
path to a virtual disk. An I/O request is routed to the path with the lowest
weight value to the RAID controller module that owns the virtual disk. If
more than one data path to the virtual disk has the same weight value, the
round-robin with subset path selection policy is used to route I/O requests
between the paths with the same weight value. The least path weight with
subset load balance policy is not supported on Linux operating systems.
Changing Load Balance Policies on the Windows Server 2008 Operating
System
Load balancing with the MD3200i series storage array is only available for
Windows Server 2008 and later versions of the operating syste m. You can
change the load balance policies from the default round robin with subset by
using either the:
•Device manager
•Disk management
To change the load balance policy using Windows Server 2008 device manager:
1
From the desktop of the host, right-click
Manage
2
Click
3
Right-click on the multi-path disk device for which you want to set the
load balance policies, then select
4
From the
this disk device.
to open the
Device Manager
MPIO
Computer Management
tab, select the load balance policy that you want to set for
to show the list of devices attached to the host.
Properties
My Computer
dialog.
.
and select
78Appendix—Load Balancing
Page 79
To change the load balance policy using Windows Server 2008 disk
management:
1
From the desktop of the host, right-click
to open the
2
Click
host.
3
Right-click on the virtual disk for which you want to set the load balance
policy, then click
From the MPIO tab, select the load balance policy that you want to set for
this virtual disk.
Computer Management
Disk Management
Properties
to show the list of virtual disks attached to the
.
My Computer
dialog.
and click
Manage
Increasing Bandwidth With Multiple iSCSI Sessions
The PowerVault MD3200i series storage array in a duplex configuration
supports two active/active asymmetric redundant controllers. Each controller
has four 1 Gbps Ethernet ports that support iSCSI. The bandwidth of the
four ports on the same controller can be aggregated to provide optimal
performance. A host can be configured to simultaneously use the bandwidth
of both the ports on a controller to access virtual disks owned by the
controller. The multi-path failover driver that Dell provides for the MD3200i
series storage array can be used to configure the storage array so that all ports
are used for simultaneous I/O access. If the multi-path driver detects multiple
paths to the same virtual disk through the ports on the same controller, it
load-balances I/O access from the host across all ports on the controller.
Figur e C-1 illustrates how the initiator can be configured to take advantage of
the load balancing capabilities of the multi-path failover driver.
Two sessions with one TCP connection are configured from the host to each
controller (one session per port), for a total of four sessions. The multi-path
failover driver balances I/O access across the sessions to the ports on the same
controller. In a duplex configuration, with virtual disks on each controller,
creating sessions using each of the iSCSI data ports of both controllers
increases bandwidth and provides load balancing.
Appendix—Load Balancing81
Page 82
82Appendix—Load Balancing
Page 83
D
Appendix—Stopping and Starting
iSCSI Services in Linux
To manually stop the iSCSI services in Linux, certain steps must be followed
to maintain parallel processing between the storage array and the host server.
1
Stop all I/O.
2
Unmount all correlated file systems. Stop iSCSI service by running the
following command:
/etc/init.d/open-iscsi stop
Appendix—Stopping and Starting iSCSI Services in Linux
Page 84
84Appendix—Stopping and Starting iSCSI Services in Linux