Dell MD3200I, MD3220I User Manual

Page 1
Dell PowerVault MD3200i and
MD3220i Storage Arrays
Deployment Guide
Page 2
Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
instructions are not followed.
WARNING: A WARNING indicates a potential for property damage, personal
injury, or death.
____________________
Information in this publication is subject to change without notice. © 2011 Dell Inc.Allrightsreserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, and PowerVault™ are trademarks of Dell Inc.
®
Intel
and Pentium® are registered trademarks of Intel Corporation in the U.S. and other countries. Microsoft Microsoft Corporation in the United States and/or other countries. Red Hat Linux a registered trademark of Novell, Inc., in the United States and other countries. VMware trademark of VMware, Inc. in the United States or other countries. Citrix™ is a trademark of Citrix Systems, Inc. and/or more of its subsidiaries, and may be register ed in the United States Patent and Trademark Office and in other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
®
, Windows®, and Windows Server® are either trademarks or registered trademarks of
®
are registered trademarks of Red Hat, Inc. in the United States and other countries. SUSE® is
®
and Red Hat® Enterprise
®
is a registered
2011 - 09 Rev. A01
Page 3
Contents
1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . 7
System Requirements . . . . . . . . . . . . . . . . . . . 7
Management Station Requirements
. . . . . . . . . 7
Introduction to Storage Arrays
. . . . . . . . . . . . . . 8
2 Hardware Installation . . . . . . . . . . . . . . . 11
Planning the Storage Configuration. . . . . . . . . . . 11
Connecting the Storage Array Cabling the Storage Array
Redundant and Non-Redundant Configurations
Direct-Attached Configurations . . . . . . . . . . 13
Network-Attached Configurations
Cabling PowerVault MD1200 Series
Enclosures . . . . . . . . . . . . . . . . . . . . . . . . 23
Expanding With Previously Configured PowerVault MD1200 Series Expansion Enclosures
Expanding With New PowerVault MD1200 Series Expansion Enclosures
. . . . . . . . . . . . . . . . . . . 12
. . . . . . . . . . . . . . . . . . . . . 23
. . . . . . . . . . . . . . 12
. . . . . . . . . . . . . . . . 12
. . . . . . . . . 20
Expansion
. . . . . . . . . . . . 25
Contents 3
Page 4
3 Installing PowerVault MD Storage
Software . . . . . . . . . . . . . . . . . . . . . . . . . 27
Graphical Installation (Recommended). . . . . . . 28
Console Installation
Silent Installation . . . . . . . . . . . . . . . . . . 30
Upgrading PowerVault MD Storage Software . . . . . 31
. . . . . . . . . . . . . . . . . 30
4 Post Installation Tasks . . . . . . . . . . . . . . 33
Before You Begin. . . . . . . . . . . . . . . . . . . . . 33
iSCSI Configuration Worksheet
IPv4 Settings IPv6 Settings
Configuring iSCSI on Your Storage Array
Automatic Configuration Using the Modular Disk Configuration Utility
Post Connection Establishment Steps
. . . . . . . . . . . . . . . . . . . . 35
. . . . . . . . . . . . . . . . . . . . 36
. . . . . . . . . . . . . 34
. . . . . . . . 38
. . . . . . . . . . . . . . 39
. . . . . . . . . . 48
5 Guidelines for Configuring Your
Network for iSCSI . . . . . . . . . . . . . . . . . . 49
Microsoft Windows Host Setup . . . . . . . . . . . . . 49
Linux Host Setup
. . . . . . . . . . . . . . . . . . . . . 51
6 Uninstalling PowerVault MD
Storage Software
Uninstalling Dell PowerVault MD Storage
Software From Windows . . . . . . . . . . . . . . . . 53
. . . . . . . . . . . . . . . . . . 53
4 Contents
Page 5
Uninstalling PowerVault MD Storage Software From Linux
. . . . . . . . . . . . . . . . . . . . . . . . 54
A Appendix—Manual Configuration
of iSCSI . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Step 1: Discover the Storage Array
(Out-of-band Management Only) . . . . . . . . . . . . 56
Default Management Port Settings Automatic Storage Array Discovery
Manual Storage Array Discovery . . . . . . . . . 57
Setting Up the Array
. . . . . . . . . . . . . . . . 57
Step 2: Configure the iSCSI Ports on the Storage Array
. . . . . . . . . . . . . . . . . . . . . . 58
Step 3: Perform Target Discovery From the iSCSI Initiator
. . . . . . . . . . . . . . . . . . . . . . 60
. . . . . . . . 56
. . . . . . . . 57
Step 4: Configure Host Access Understanding CHAP Authentication
What is CHAP? Target CHAP Mutual CHAP
. . . . . . . . . . . . . . . . . . . 63
. . . . . . . . . . . . . . . . . . . . 63
. . . . . . . . . . . . . . . . . . . . 63
CHAP Definitions
. . . . . . . . . . . . . 62
. . . . . . . . . . 63
. . . . . . . . . . . . . . . . . . 64
Step 5: Configure CHAP Authentication on the Storage Array (Optional)
. . . . . . . . . . . . . . . 64
Configuring Target CHAP Authentication on the Storage Array
. . . . . . . . . . . . . . . . . . . . 65
Configuring Mutual CHAP Authentication on the
Storage Array. . . . . . . . . . . . . . . . . . . . 66
Step 6: Configure CHAP Authentication on the Host Server (Optional)
. . . . . . . . . . . . . . . . . . 66
Contents 5
Page 6
Step 7: Connect to the Target Storage Array From he Host Server
Step 8: (Optional) Set Up In-Band Management. . . . . 74
. . . . . . . . . . . . . . . . . . . . . . 70
B Appendix—Using Internet Storage
Naming Service . . . . . . . . . . . . . . . . . . . . 75
C A ppendix—Load Balancing. . . . . . . . . . 77
Load Balance Policy . . . . . . . . . . . . . . . . . . . 77
Round Robin With Subset
Least Queue Depth With Subset . . . . . . . . . . 78
Least Path Weight With Subset Changing Load Balance Policies on the
Windows Server 2008 Operating System. . . . . . 78
Increasing Bandwidth With Multiple iSCSI Sessions
. . . . . . . . . . . . . . . . . . . 79
. . . . . . . . . . . . . . 77
. . . . . . . . . . . 78
D Appendix—Stopping and Starting
iSCSI Services in Linux . . . . . . . . . . . . . . 83
6 Contents
Page 7
1

Introduction

This guide provides information about deploying Dell PowerVault MD MD3200i and Dell PowerVault MD3220i storage arrays. The deployment process includes:
Hardware installation
Modular Disk Storage Manager (MDSM) software installation
Initial system configuration
Other information provided include system requirements, storage array organization, and utilities.
NOTE: For more information on product documentation see,
support.dell.com/manuals.
MDSM enables an administrator to configure and monitor storage arrays for optimum usability. The version of MDSM included on the PowerVault MD series resource media can be used to manage both the PowerVault MD3200i series and the earlier PowerVault MD series storage arrays. MDSM is compatible with both Microsoft Windows and Linux operating systems.

System Requirements

Before installing and configuring the PowerVault MD3200i series hardware and software, ensure that the operating system is supported and minimum system requirements are met. For more information, see the Dell PowerVault Support Matrix available on support.dell.com/manuals.

Management Station Requirements

A management station uses MDSM to configure and manage storage arrays across the network. A management station must meet the following minimum system requirements:
Intel Pentium or an equivalent processor (1333 MHz or faster) with 512 MB RAM (1024 MB recommended)
1 GB disk space
Introduction 7
Page 8
Display resolution of 1024x768 with 16 million colors (1280x1024 32-bit recommended)
Microsoft Windows, Red Hat Enterprise Linux, and SUSE Linux Enterprise Server.
NOTE: Operating system installations can be either native or hypervisor guest
configurations.
NOTE: Supported hypervisors include Microsoft Hyper-V, Citrix XenServer,
and VMware. For information about the supported versions, see the Support Matrix at support.dell.com.
Administrator or equivalent permissions

Introduction to Storage Arrays

A storage array includes various hardware components, such as physical disks, RAID controller modules, fans, and power supplies, gathered into enclosures. An enclosure containing physical disks accessed through RAID controller modules is called a storage array.
One or more host servers attached to the storage array can access the data on the storage array. You can also establish multiple physical paths between the host(s) and the storage array so that loss of any single path (for example, through failure of a host server port) does not result in loss of access to data on the storage array.
The storage array is managed by MDSM running on a:
Host server—On a host server, MDSM and the storage array communicate management requests and event information using iSCSI ports.
Management station—On a management station, MDSM communicates with the storage array either through an Ethernet connection to the storage array management port or though an Ethernet connection to a host server. The Ethernet connection passes management information between the management station and the storage array using iSCSI ports.
Using MDSM, you can configure the physical disks in the storage array into logical components called disk groups and then divide the disk groups into virtual disks. Disk groups are created in the unconfigured capacity of a storage array. Virtual disks are created in the free capacity of a disk group.
8 Introduction
Page 9
Unconfigured capacity comprises of physical disks not already assigned to a disk group. When a virtual disk is created using unconfigured capacity, a disk group is automatically created. If the only virtual disk in a disk group is deleted, the disk group is also deleted. Free capacity is space in a disk group that is not assigned to any virtual disk.
Data is written to the physical disks in the storage array using RAID technology. RAID levels define the way in which data is written to physical disks. Different RAID levels offer different levels of accessibility, redundancy, and capacity. You can set a specified RAID level for each disk group and virtual disk on your storage array.
For more information about using RAID and managing data in your storage solution, see the Owner’s Manual
at
support.dell.com/manuals
.
Introduction 9
Page 10
10 Introduction
Page 11
2

Hardware Installation

Befo re using thi s guide, ensure that y ou review the instructions in the:
Getting Started Guide
the storage array provides information to configure the initial setup of the system.
Planning section of the information up your storage solution. See the
about important concepts you must know before setting

Planning the Storage Configuration

Consider the following before installing your storage array:
Evaluate data storage needs and administrative re quirements.
Calculate availability requirements.
Decide the frequency and level of backups, such as weekly full backups with daily partial backups.
Consider storage array options, such as password protection and e-mail alert notifications for error conditions.
Design the configuration of virtual disks and disk groups according to a data organization plan. For example, use one virtual disk for inventory, a second for financial and tax information, and a third for customer information.
Decide whether to allow space for hot spares, which automatically r eplace failed physical disks.
—The
Getting Started Guide
Owner’s Manual—
Owner’s Manual
that shipped with
The planing section provides
at
support.dell.com
.
Hardware Installation 11
Page 12

Connecting the Storage Array

The storage array is connected to a host using two hot-swappable RAID controller modules. The RAID controller modules are identified as RAID controller module 0 and RAID controller module 1.
Each RAID controller module has four iSCSI In port connectors that provide Ethernet connections to the host server or switches. Each RAID controller module also contains an Ethernet management port and a SAS Out port. The Ethernet management port allows you to install a dedicated management station (server or stand-alone system). The SAS Out port allows you to connect the storage array to optional PowerVault MD1200 series e xpansion enclosures for additional storage capacity.
Each PowerVault MD3200i series storage array can be expanded to a maximum of 120 (or 192, if enabled using Premium Feature activation) physical disks through a maximum of seven PowerVault MD1200 series expansion enclosures.

Cabling the Storage Array

The iSCSI interface enables different host-to-controller configurations. The figures in this chapter are grouped according to the following categories:
Direct-attached configurations (no Ethernet switches are used)
Network-attached (SAN) configurations (Ethernet switches are used)

Redundant and Non-Redundant Configurations

Non-redundant configurations are configurations that provide only a single data path from a host to the storage array. This type of configuration is only recommended for non-critical data storage. Path failure from a failed or removed cable, a failed NIC, or a failed or removed RAID controller module results in loss of host access to storage on the storage array.
Redundancy is established by installing separate data paths between the host and the storage array, in which each path is to one of the two RAID controller modules installed in the storage array. Redundancy protects the host from losing access to data in the event of path failure, because both RAID controller modules can access all the disks in the storage array.
12 Hardware Installation
Page 13

Direct-Attached Configurations

You can connect the Ethernet ports of the host servers directly to the storage array RAID controller module iSCSI ports.
Single Path Data Configurations
With a single path configuration, a group of heterogeneous hosts can be connected to the storage array through a single physical Ethernet port. Since there is only one port, there is no redundancy, although each iSCSI portal supports multiple connections. This configuration is supported for both single controller and dual controller modes.
Hardware Installation 13
Page 14
Figure2-1 shows a non-redundant cabling configuration to the RAID
Corporate, public, or private network
Storage array
Server 1 Server 2 Server 3 Server 4
controller modules using a single path data configuration.
Figure 2-1. Four Hosts Connected to a Single Controller
14 Hardware Installation
Page 15
Figure 2-2 shows two hosts connected to a single controller array.
Corporate, public, or private network
Storage array
Server 1
Server 2
Figure 2-2. T wo Hosts Connected to a Single Controller
Hardware Installation 15
Page 16
Figure2-3 shows eight stand-alone hosts supported in a dual controller array
Corporate, public, or private network
Storage array
Server 1
Server 2
Server 3 Server 4
Server 8
Up to 8 hosts
configuration with a single data path.
Figure 2-3. Eight Hosts in a Dual-Controller Configuration
16 Hardware Installation
Page 17
Dual-Path Data Configuration
In Figure2-4, up to four servers are directly attached to the RAID controller modules. If the host server has a second Ethernet connection to the array, it can be attached to the iSCSI ports on the array's second controller. This configuration provides improved availability by allowing two separate physical paths for each host, which ensures full redundancy if one of the paths fail.
In Figure2-5, up to four cluster nodes are directly attached to two RAID controller modules. Since each cluster node has redundant paths, loss of a single path would still allow access to the to the storage array through the alternate path.
Hardware Installation 17
Page 18
Figure 2-4. Four Hosts Connected to Two Controllers
Storage array
Server 1 Server 2 Server 3 Server 4
Corporate, public, or private network
18 Hardware Installation
Page 19
Figure 2-5. Four Hosts Connected in a Dual-Controller Configuration
Corporate, public, or private network
Storage array
Four node cluster server
Hardware Installation 19
Page 20

Network-Attached Configurations

You can also cable the host servers to the RAID controller module iSCSI ports through industry-standard 1GB Ethernet switches. An iSCSI configuration that uses Ethernet switches is frequently referred to as an IP SAN. By using an IP SAN, the PowerVault MD3200i series storage array can support up to 64 hosts simultaneously. This configuration supports either single- or dual-path data configurations and either single or dual controller modules.
Figure2-6 shows up to 64 stand-alone servers attached (using multiple sessions) to a single RAID controller module through a network. Hosts that have a second Ethernet connection to the network allow two separate physical paths for each host, which ensures full redundancy if one of the paths fail. Figure2-7 shows how the same number of hosts can be similarly attached to a dual RAID controller module configuration.
20 Hardware Installation
Page 21
Corporate, public, or private network
Up to 64 hosts
Switch
Storage array
Figure 2-6. 64 Servers Connected to a Single Controller
Hardware Installation 21
Page 22
Corporate, public, or private network
Switch
Storage array
Up to 64 hosts
Figure 2-7. 64 Servers Connected to Two Controllers
22 Hardware Installation
Page 23

Cabling PowerVault MD1200 Series Expansion Enclosures

You can expand the capacity of your PowerVault MD3200i series storage array by adding PowerVault MD1200 series expansion enclosures. You can expand the physical disk pool to a maximum of 120 (or 192, if enabled using Premium Feature activation) physical disks using a maximum of seven expansion enclosures.

Expanding With Previously Configured PowerVault MD1200 Series Expansion Enclosures

Use this procedure if your expansion enclosure is directly attached to and configured on a Dell Po werEdge RAID Controller (PER C)H800 adapter. Data from virtual disks created on a PERC H800 adapter cannot be directly migrated to a PowerVault MD3200i series storage array or to a PowerVault MD1200 series expansion enclosure connected to a PowerVault MD3 200i series storage array.
CAUTION: If a PowerVault MD1200 series expansion enclosure that was
previously attached to PERC H800 adapter is used as an expansion enclosure to a PowerVault MD3200i series storage array, the physical disks of the expansion enclosure are reinitialized and data is lost. You must backup all data on the expansion enclosure before attempting the expansion.
To attach previously configured PowerVault MD1200 series expansion enclosures to the PowerVault MD3200i series storage array:
1
Back up all data on the expansion enclosure(s).
2
While the enclosure is still attached to the PERC H800 controller, upgrade the expansion enclosure firmware to the latest version available at
support.dell.com
Windows systems users can reference the kernel users can reference the
.
DUP.bin
DUP.exe
package.
package and Linux
3
Ensure that the storage array software is installed and up to date before adding the expansion enclosure(s).
For more information, see the
support.dell.com/manuals
Support Matrix
.
at
Hardware Installation 23
Page 24
a
Install the software and driver package included on the PowerVault MD series resource media.
For information about installing the software, see "Installing PowerVault MD Storage Software" on page 25.
b
Update the storage array RAID controller module firmware and NVSRAM to the latest versions available at
support.dell.com
, using
PowerVault MDSM.
c
Click
Tools
Upgrade RAID Controller Module Firmware
in the
Enterprise Management Window (EMW).
4
Stop all I/O and turn off the system and attached units.
a
Stop all I/O to the storage array and turn off the host systems attached to the storage array.
b
Turn off the storage array .
c
Turn off the expansion enclosure(s) in the affected system.
5
Cable the expansion enclosure(s) to the storage array.
6
Turn on attached units:
a
Turn on the expansion enclosure(s). Wait for the enclosure status LED to turn blue.
b
Turn on the storage array and wait for the status LED to indicate that the unit is ready:
If the status LEDs are solid amber, the storage array is still coming online.
If the status LEDs are blinking amber, there is an error that can be viewed using the PowerVault MDSM.
If the status LEDs are solid blue, the storage array is ready.
c
When the storage array is online and ready, turn on any attached host systems.
7
After the PowerVault MD1200 series expansion enclosure is configured as an expansion enclosure of the storage array, restore the data that was backed up in step 1.
After the expansion enclosures are online, they can be accessed as a part of the storage array.
24 Hardware Installation
Page 25

Expanding With New PowerVa ult MD1200 Series Ex pan sion Enclo s ures

Perform the following steps to attach new PowerVault MD1200 series expansion enclosures to a PowerVault MD3200 i series sto r age array:
1
Before adding the expansion enclosure(s), ensure that the storage array software is installed and up to date. For more information, see the
Matrix
at
support.dell.com/manuals
a
Install the software and driver package included on the PowerVault
.
MD series resource media. For information about installing the software, see "The PowerVault
MD series storage software installer provides features that include the core software, providers, and optional utilities. The core software feature includes the host-based storage agent, multipath driver, and MD Storage Manager (MDSM) application used to configure, manage, and monitor the storage array solution. The providers feature includes providers for the Microsoft Virtual Disk Service (VDS) and Microsoft Volume Shadow-Copy Service (VSS) framework. The PowerVault Modular Disk Configuration Utility (MDCU) is an optional utility that provides a consolidated approach for configuring the management ports, iSCSI host ports, and creating sessions for the iSCSI Modular Disk storage arrays. It is recommended that you install and use PowerVault MDCU to configure iSCSI on each host connected to the storage array." on page 27.
b
Set up the PowerVault MD1200 series expansion enclosure(s). For information about setting up the PowerVault MD1200 series
expansion enclosure(s), see the
support.dell.com/manuals
Hardware Owner’s Manual
.
Support
at
c
Using PowerVault MDSM, update the RAID controller module firmware and NVSRAM to the latest versions available on
support.dell.com
. From the Enterprise Management Window
(EMW).
d
Click
ToolsUpgrade RAID Controller Module Firmware
2
Stop I/O and turn off all systems:
a
Stop all I/O to the storage array and turn off affected host systems attached to the storage array.
b
Turn off the storage array .
.
Hardware Installation 25
Page 26
c
Turn off any expansion enclosure(s) in the affected system.
3
Cable the expansion enclosure(s) to the storage array.
4
Turn on attached units:
a
Turn on the expansion enclosure(s). Wait for the enclosure status LED to turn blue.
b
Turn on the storage array and wait for the status LED to indicate that the unit is ready:
If the status LEDs are solid amber, the storage array is still coming online.
If the status LEDs are blinking amber, there is an error that can be viewed using PowerVault MDSM.
If the status LEDs are solid blue, the storage array is ready.
c
After the storage array is online and ready, turn on any attached host systems.
5
Using PowerVault MDSM, update all attached expansion enclosure firmware if it is out of date:
a
From the EMW, select the enclosure that you want to update and
b c
enter the Click Select
Array Management Window
AdvancedMaintenance
Select All
to update all the attached expansion enclosures
(AMW).
DownloadEMM Firmware
simultaneously.
.
26 Hardware Installation
Page 27
3

Installing PowerVault MD Storage Software

The Dell PowerVault MD series resource media contains software and drivers for both Linux and Microsoft Windows operating systems.
The root of the media contains a readme.txt file covering changes to the software, updates, fixes, patches, and other important data applicable to both Linux and Windows operating systems. The readme.txt file also specifies requirements for accessing documentation, information regarding versions of the software on the media, and system requirements for running the software.
F or mor e information on supported hardwar e and software for PowerVault systems, see the Support Matrix located at support.dell.com/manuals.
NOTE: It is recommended that you install all the latest updates available at
support.dell.com.
The PowerVault MD series storage software installer provides features that include the core software, providers, and optional utilities. The core software feature includes the host-based storage agent, multipath driver, and MD Storage Manager (MDSM) application used to configure, manage, and monitor the storage array solution. The providers feature includes providers for the Microsoft Virtual Disk Service (VDS) and Microsoft V olume Shadow-Copy Service (VSS) framework. The PowerVault Modular Disk Configuration Utility (MDCU) is an optional utility that provides a consolidated approach for configuring the management ports, iSCSI host ports, and creating sessions for the iSCSI Modular Disk storage arrays. It is recommended that you install and use PowerVault MDCU to configure iSCSI on each host connected to the storage array .
NOTE: For more information about the Microsoft VDS and Microsoft VSS providers,
see the Owner's Manual. To install the software on a Windows or Linux system, you must have administrative or root privileges.
Installing PowerVault MD Storage Software 27
Page 28
NOTE: If Dynamic Host Configuration Protocol (DHCP) is not used, initial configuration
of the management station must be performed on the same phy sical subnet as the storage array. Additionally , during initial configuration, at least one netwo rk adapter must be configured on the same IP subnet as the storage array’s default management port (192.168.128.101 or 192.168.128.102). After initial configuration, the management ports are configured using MDSM and the management station’ s IP address can be changed back to the previous settings.
The PowerVault MD series resource media offers the following three installation methods:
Graphical Installation (Recommended)—This is the recommended installation procedure for most users. The installer presents a graphical wizard-driven interface that allows customization of which components are installe d.
Console Installation—This installation procedur e is useful for Linux users that do not desire to install an X-Window environment on their supported Linux platform.
Silent Installation—This installation procedure is useful for users that prefer to create scripted installations.

Graphical Installation (Recommended)

The PowerVault MD Storage Manager software configures, manages and monitors the storage array. The PowerVault MD Configuration Utility (MDCU) is an optional utility that provides a consolidated approach for configuring the management and iSCSI host ports, and creating sessions for the iSCSI modular disk storage arrays. It is recommended that you use PowerVault MDCU to configure iSCSI on each host server connected to the storage array. To install the PowerVault MD storage software:
1
Insert the PowerVault MD series resource media. Depending on your operating system, the installer may launch
automatically. If the installer does not launch automatically, navigate to the root directory of the installation media (or downloaded installer image) and run the navigate to the root of the resource media and run the autorun file.
md_launcher.exe
file. F or Linux-based systems,
NOTE: By default, Red Hat Enterprise Linux mounts the resource media with the
–noexec mount option which does not allow you to run executable files. To change this setting, see the Readme file in the root directory of the installation media.
28 Installing PowerVault MD Storage Software
Page 29
2
Select
Install MD Storage Software.
3
Read and accept the license agreement.
4
Select one of the following installation options from the Install Set dropdown menu:
Full (recommended)—Installs the PowerVault MD Storage Manager (client)software, host-based storage agent, multipath driver, and hardware providers.
Host Only—Installs the host-based storage agent and multipath drivers.
Management—Installs the management software and hardware providers.
Custom—Allows you to select specific components.
5
Select the PowerVault MD storage array model(s) you are setting up to serve as data storage for this host server.
6
Choose whether to start the event monitor service automatically when the host server reboots or manually.
NOTE: This option is applicable only to Windows client software installation.
7
Confirm the installation location and choose
8
If prompted, reboot the host server once the installation completes.
9
When the reboot is complete, the P owerVault MDCU may launch
Install
.
automatically. If the PowerVault MDCU does not launch automatically, launch it manually.
In a Windows-based operating system, click
Disk Configuration Utility
.
In a Linux-based operating system, double-click the
Configuration Utility
10
Start
MD Storage Manager
11
If applicable, activate any premium features purchased with your storage
icon on the desktop.
and discover the array(s).
StartDellModular
Modular Disk
array. If you purchased premium features, see the printed activation card shipped with your storage array.
Installing PowerVault MD Storage Software 29
Page 30
NOTE: The MD Storage Manager installer automatically installs the required
drivers, firmware, and operating system patches/hotfixes to operate your storage array. These drivers and firmware are also available at support.dell.com. In addition, see the Support Matrix at support.dell.com/manuals for any additional settings and/or software required for your specific storage array.

Console Installation

NOTE: Console installation only applies to Linux systems that are not running a
graphical environment.
The autorun script in the root of the resource media detects when there is no graphical environment running and automatically starts the installer in a text-based mode. This mode provides the same options as graphical installation with the exception of the PowerVault MDCU specific options. The PowerVault MDCU requires a graphical environment to operate.
NOTE: The console mode installer provides the option to install the PowerVault
MDCU.However a graphical environment is required to utilize the PowerVault MDCU.

Silent Installation

To run silent installation on a Windows system:
1 Copy the custom_silent.properties file in the /windows folder of the
installation media or image to a writable location on the host server.
2 Modify the custom_silent.properties file to reflect the features, models
and installation options to be used. Then, save the file.
3 Once the custom_silent.properties file is revised to reflect your specific
installation, run the following command to begin the silent installation:
mdss_install.exe –f <host_server_path>\ custom_silent.properties
To run silent installation on a Linux system:
NOTE: On Red Hat Enterprise Linux 6 operating systems, run the following
script from the root directory to install prerequisite packages:
# md_prereq_install.sh
1 Copy the custom_silent.properties file in the /windows folder of the
installation media or image to a writable location on the host server.
30 Installing PowerVault MD Storage Software
Page 31
2 Modify the custom_silent.properties file to reflect the features, models
and installation options to be used. Then, save the file.
3 Once the custom_silent.properties file is revised, run the following
command to begin the installation:
./mdss_install.bin –f <host_server_path>/custom_silent.properties

Upgrading PowerVault MD Storage Software

To upgrade from a previous version of the MD Storage Manager application, uninstall the previous version (see "Uninstalling PowerVault MD Storage Software" on page 53), and then follow the instructions in this chapter to install the new version.
Installing PowerVault MD Storage Software 31
Page 32
32 Installing PowerVault MD Storage Software
Page 33
4

Post Installation Tasks

Before using the storage array for the first time, complete a number of initial configuration tasks in the order shown. These tasks are performed using the MD Storage Manager (MDSM) software.
NOTE: If Dynamic Host Configuration Protocol (DHCP) is not used, initial configuration
using the management station must be performed on the same phy sical subnet as the storage array. Additionally, during initial configuration, at least one network adapter must be configured on the same IP subnet as the storage array’ s default management port (192.168.128.101 or 192.168.128.102). After initial configuration, the management ports are configured using MDSM and the management station’ s IP address can be changed back to the previous settings.

Before You Begin

Before you begin configuring iSCSI, you must fill out the iSCSI configuration worksheet. Gathering this type of information about your network prior to starting the configuration steps helps you to complete the process in less time.
iSCSI Configuration Terminolo gy
Table 4-1. Standard Terminology Used in iSCSI Configu ration
Term Definition
CHAP (Challenge Handshake Authentication Protocol)
Host or host server A server connected to the storage array using
Host server port SCSI port on the host server used to connect
An optional security protocol used to control access to an iSCSI storage system by restricting use of the iSCSI data ports on both the host server and storage array. For more information on the types of CHAP authentication supported, see "Under standing CHAP Authentication" on page63.
iSCSI ports.
it to the storage array.
Post Installation Tasks 33
Page 34
Table 4-1. Standard Terminology Used in iSCSI Configuration
Term Definition
iSCSI initiator The i S CS I - s p e c if i c s o ftware ins t a l l e d o n t h e
host server that controls communications between the host server and the storage array.
iSCSI host port The iSCSI port (two per controller) on the
storage array.
iSNS (Microsoft Internet Storage Naming Service)
Management station The system from which you manage your
Storage array The enclosure containing the storage data
Target An iSCSI port on the storage array that
An automated discovery, management and configuration Storage Naming Service) tool used by some iSCSI devices.
host server/storage array configuration.
accessed by the host server .
accepts and responds to requests from the iSCSI initiator installed on the host server.

iSCSI Configuration Worksheet

The iSCSI configuration worksheet helps you plan your configuration. Recording host server and storage array IP addresses at a single location enables you to configure your setup faster and more efficiently.
"Guidelines for Configuring Your Network for iSCSI" on page 49 provides general network setup guidelines for both W indows and Linux environments. It is recommended that you review these guidelines before completing the worksheet.
34 Post Installation Tasks
Page 35

IPv4 Settings

Mutual CHAP Secret
Target CHAP Secret
A
B
host server
PowerVault MD32xxi
192.168.130.101 (In 0 default)
192.168.131.101 (In 1 default)
192.168.132.101 (In 2 default)
192.168.133.101 (In 3 default)
192.168.128.101 (management network port)
192.168.130.102 (In 0 default)
192.168.131.102 (In 1 default)
192.168.132.102 (In 2 default)
192.168.133.102 (In 3 default)
192.168.128.102 (management network port)
If you need additional space for more than one host server, use an additional sheet.
iSCSI port 1 iSCSI port 2 iSCSI port 3 iSCSI port 4 Management port Management port
Static IP address (host server)
Subnet
Default gateway
(should be different for each NIC)
A
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
Static IP address (host server)
Subnet
Default gateway
B
iSCSI controller 0, In 0 iSCSI controller 0, In 1
iSCSI controller 0, In 2 iSCSI controller 0, In 3 Management port cntrl 0 iSCSI controller 1, In 0 iSCSI controller 1, In 1
iSCSI controller 1, In 2 iSCSI controller 1, In 3 Management port cntrl 1
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
___ . ___ . ___ . ___
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
___ . ___ . ___ . ___
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
___ . ___ . ___ . ___
Post Installation Tasks 35
Page 36

IPv6 Settings

Mutual CHAP
Target CHAP
A
B
If you need additional space for more than one host server, use an additional sheet.
Link local IP address Routable IP address Subnet prefix Gateway
A
host server
Host iSCSI port 1
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
Link local IP address Routable IP address Subnet prefix Gateway
Host iSCSI port 2
___ . ___ . ___ . ___ ___ . ___ . ___ . ___ ___ . ___ . ___ . ___
___ . ___ . ___ . ___ iSCSI controller 0, In 0 IP address Routable IP address 1 Routable IP address 2 Router IP address
B
iSCSI controller 0, In 1 IP address Routable IP address 1 Routable IP address 2 Router IP address
iSCSI controller 0, In 2 IP address Routable IP address 1 Routable IP address 2 Router IP address
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
PowerVault MD32xxi
36 Post Installation Tasks
Page 37
iSCSI controller 0, In 3 IP address Routable IP address 1 Routable IP address 2 Router IP address
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
iSCSI controller 1, In 0 IP address Routable IP address 1 Routable IP address 2 Router IP address
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
iSCSI controller 1, In 1 IP address Routable IP address 1 Routable IP address 2 Router IP address
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
iSCSI controller 1, In 2 IP address Routable IP address 1 Routable IP address 2 Router IP address
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
iSCSI controller 1, In 3 IP address Routable IP address 1 Routable IP address 2 Router IP address
FE80 : 0000 : 0000 : 0000 : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____ ____ : ____ : ____ : ____ : ____ : ____ : ____ : ____
Post Installation Tasks 37
Page 38

Configuring iSCSI on Your Storage Array

The following sections contain step-by-step instructions for configuring iSCSI on your storage array. However, before beginning, it is important to understand where each of these steps occur in relation to your host server/storage array environment.
Table 4-2 below shows each specific iSCSI configuration step and where it occurs.
Table 4-2. Host Server Vs. Storage Array
This Step is Performed on the Host Server Using the Microsoft or Linux iSCSI Initiator
3
Perform target discovery from the iSCSI initiator
6
(Optional) Configure CHAP authentication on the host server
7
Connect to the storage array from the host server
This Step is Performed on the Storage Array Using PowerVault MD Storage Manager
1
Discover the storage array
2
Configure the iSCSI ports on the storage array
4
Configure host access
5
(Optional) Configure CHAP authentication on the storage array
8
(Optional) Set up in-band management
NOTE: It is recommended that you use the PowerVault Modular Disk Configuration Utility
(MDCU) for iSCSI configuration. The PowerVault MDCU wizards guides you through the configuration steps described above. If you want to perform a manual configuration, see "Appendix—Manual Configuration of iSCSI" on page55.
38 Post Installation Tasks
Page 39

Automatic Configuration Using the Modular Disk Configuration Utility

NOTE: If PowerVault MDCU is not installed, it can be installed from the PowerVault
MD series resource media.
PowerVault MDCU provides a consolidated approach for configuring the iSCSI network of host servers and iSCSI-based storage arrays using a wizard-driven interface. This utility also enables the user to configure the iSCSI sessions of the host server according to the best practices and to achieve load-balanced paths with the storage array iSCSI host ports.
NOTE: PowerVault MDCU is only applicable to iSCSI-based PowerVault MD3200i
series storage arrays. It does apply to SAS-based PowerVault MD3200 series storage arrays.
If you select Launch the MDCU after reboot during the installation of the host software, the utility automatically launches after the next host server reboot. This utility can also be launched manually.
The utility has a context sensitive online help to guide you through each step of the wizard.
The PowerVault MDCU performs:
Storage array configuration
Host configuration
Storage Array Configuration
Before a host iSCSI initiator and an iSCSI-based storage array can communicate, they must be configured with information such as which IP addresses and authentication method to use. Since iSCSI initiators establish connections with an already configured storage array, the first task is to configure your storage arrays to make them available for iSCSI initiators.
This utility requires network access to the management ports of the storage arrays you wish to configure. You must have a properly functioning network infrastructure before attempting to configure your storage arrays. If your storage arrays are already configured, you can skip dir ectly to the host configuration.
This configuration task generally involves the following steps:
1
Discover available storage array(s) for configuration.
2
Select a storage array to configure.
3
Set a storage array name and password.
Post Installation Tasks 39
Page 40
4
Configure the IP protocols and addresses for the management ports.
5
Configure the IP protocols and addresses for the iSCSI ports.
6
Specify the CHAP authentication method.
7
Apply the settings after reviewing a summary.
8
Repeat the process starting from step 2 to configure additional arrays.
Host Configuration (Host Connectivity Configuration)
After you have completed configuring your iSCSI-based storage arrays, the next task is to run this utility on all hosts that need to access the storage arrays. Depending on your network configuration, your host may be the same machine you use to manage your storage arrays, or it may be on a completely separate network.
The option to configure a host is disabled if the machine the utility is running on does not have an iSCSI initiator or the required driver components installed. When the option is disabled, the utility also displays an informational message. If you are running the utility on a host which is not connected to the iSCSI–based storage array (or which you do not wish to connect to the array), the informational message can be ignored.
The task generally involves the following steps:
1
Discover available storage array(s) for connection.
2
Select a storage array to connect to.
3
Specify the CHAP secret.
4
Select the iSCSI ports the host's initiator uses to log on.
5
Repeat the process starting from step 2 to connect to additional arrays.
6
Repeat these steps on each host that needs access to the storage array(s).
Before Starting the Configuration Process
Before you start configuring the storage array or host connectivity, it is recommended that you fill out the iSCSI configuration worksheet to help you plan your configuration. You may need to use several worksheets depending on your configuration.
40 Post Installation Tasks
Page 41
Keep the following guidelines in mind for the storage array and host configuration:
For optimal performance, ensure your network configuration is valid by consulting the storage array's support matrix.
If your host has multiple network interfaces, it is recommended that each network interface uses a separate subnet.
For redundancy in a dual controller (duplex) configuration, ensure each host network interface is configured to connect to both storage array controllers.
For optimal load balancing, ensure each host network interface that is used for iSCSI traffic is configured to connect to each storage array controller.
It is recommended that each host network interface only establishes one iSCSI session per storage array controller.
NOTE: The utility tries to follow the guidelines for the host connectivity whenever
possible based on the available host network interfaces and their connectivity with the iSCSI host ports of the storage array.
Configure the Storage Array Using PowerVault MDCU
To configure the iSCSI-based storage array(s) using PowerVault MDCU:
1
Launch the utility (if it is not launched automatically) from the server with access to the management ports of the storage array(s) to be configured.
For Windows, click
Software

Modular Disk Configuration Utility
StartAll ProgramsDellMD Storage
.
For Linux, click the
/opt/dell/mdstoragesoftwaare/mdconfigurationutility
MDCU
icon on the desktop or navigate to the
directory in a
terminal window and run PowerVault MDCU.
2
Click
Next
to continue.
3
Select the configuration task click
Next
to continue.
4
Select the method by which the utility should discover the storage arrays for configuration and click
Configure Modular Disk Storage Array
Next
.
Post Installation Tasks 41
and
Page 42
Automatic Discovery—Automatic discovery queries the local sub-network for all iSCSI-based storage arrays and may take several minutes to complete.
Manual Discovery—Manual discovery allows you to locate iSCSI-based storage arrays that are outside of the local sub-network. Manual discovery requires selecting whether your storage array has a single controller (simplex) or dual controllers (duplex) and whether to use IPv4 or IPv6 protocol for communicating with the management port of the storage array.
5
The next screen presents a list of the iSCSI-based storage arrays that were discovered based on the discovery process selected in step 3.
If you select iSCSI-based storage arrays that were discovered in the subnet.
Automatic Discovery
, the screen displays a list of all the
If you select whose IP addresses were entered. You can add additional arrays to the list by clicking the
You can also remove the arrays from this list by using the You can click
LED in order to locate the array physically and ensure it is the array you intend to configure. Click before you proceed.
Select the array by clicking the radio button of the corresponding storage array and then click
6
Enter the name of the storage array and the password. If you want to set a new password for the array, select
then enter the new password in the
Password
7
Select the IP protocol (IPv4/IPv6) to be used by the management port. Also , for each protocol, select whether the configuration of the management port IP addresses is to be done manually or automatically. F or more information, see the
online help
Click the configuration method.
Manual Discovery
Add
button on this screen.
Blink Array
Next
fields. Click
.
Next
to continue after you has finished selecting the protocols and
Next
, then the list contains only the arrays
Remove
to start the blinking of the array’s front panel
Stop Blinking
.
to continue.
to stop the blinking of the array
Set P assword
New Password
and
Confirm New
button.
and
42 Post Installation Tasks
Page 43
If you have not selected
Specify Configuration Manually
for any of the
two protocols, then you can skip step 8.
8
If you have selected
Specify Configuration Manually
for any of the two protocols in the last step, a series of screens showing the backend view image of the storage array controllers is displayed. Each image contains IP addresses of management ports of the controllers. Also each image has one management port highlighted in red.
For IPv4 address of the highlighted port, enter the IP addr ess, subnet mask and gateway address in the fields shown below the image in order to modify it.
For IPv6 address of the highlighted port, enter the local IP address, routable IP, and router IP address in the fields shown below the image in order to modify it.
Click
Next
to continue through these images to complete the
configuration of all the management ports for the selected protocols.
9
In the
CHAP Configuration
Next
. For more information on CHAP see "Understanding CHAP
screen, select the CHAP method and click
Authentication" on page 63.
10
In the
Summary
screen, review the information that you entered for the
storage array. Click
Apply
to save the changes to the storage array.
NOTE: To abort the configuration for the storage array and to go back to
select a storage array for configuration, click Cancel Array.
11
On the configure additional array. Click
12
If you selected
13
If you selected No in step 12, then on the
Configure Additional Arrays
Next
Yes
in the above step, then start again from step 4.
screen, select whether you want to
to continue.
Configure Host Connectivity
screen, select whether you want to configure the connectivity for current host’s iSCSI initiator. Click
If you selected
14
Click
Finish
No
on the final screen to exit the utility.
above, then you are done with the configuration task.
Next
to continue.
Post Installation Tasks 43
Page 44
15
If you selected
Yes
in the last step, then the
Select Storage Array
displayed. Select the storage array that you want to configure for connectivity to the local host.
NOTE: The storage arrays configured by the utility are marked as
Configuration Complete against their names in the list. This helps you to identify the arrays that are ready to be configured for host access.
16
In the
Storage Array Login
screen, in the Controller# column, select the iSCSI host port of the storage array that needs to be configured and it’s IP address(es). In the
Host Address
column, from drop-down menu list, select the host IP address that will login to the iSCSI host port of the storage array.
See "Source Port Selection for iSCSI Host Ports" on page 46’ for more information about how these host IP addresses are listed in the drop-down menu and the recommended guidelines for selecting the host IP addresses.
Click
Next
to continue to enter the log in information for another
controller or Click
17
In the
Connect to Additional Arrays
Apply
to save the log in information.
screen, select whether you want to
connect to another storage array or not. If you want to connect to another storage array, repeat the above steps
starting from step 15.
screen is
If you do not want to connect to additional arrays, then click final screen to exit the utility.
44 Post Installation Tasks
Finish
on the
Page 45
Configure the Host Connectivity Using PowerVault MDCU
To configure the host connectivity for an iSCSI-based storage array(s) using PowerVault MDCU:
1
Launch the utility (if it is not launched automatically) from the server which needs to be configured for access to the iSCSI-based storage array(s). This server must have access to the array either using the array’s management ports or using the array’s iSCSI host ports.
See step 1 in "Configure the Storage Array Using PowerVault MDCU" on page 41 for the instructions on how to launch the utility.
Click
Next
to continue.
2
In the
Configuration Task
NOTE: This task is not supported or is disabled if the MDSM agent is not
installed on the host where you are running the utility. The agent is typically not installed on the Windows client systems such as Windows XP.
3
In the
Discovery Method
screen, select
Configure Host
and click
screen, select one of the discovery methods.
If the host has access to the management ports of the PowerVault MD storage array(s), then select click
Next
.
Discover via Management Port
method and
If the host does not have the access to the management ports of the array, then select the has access to the iSCSI host ports of the storage array) and click
Discover via iSCSI Port
method (assuming that the host
Next
Continue to step 5.
Next
.
.
4
Follow the instructions in step 3 and step 4 of "Configure the Storage Array Using PowerVault MDCU" on page 41 to select the storage array that needs to be configured for connectivity with the host. Go to step6.
5
In the
iSCSI Port IP Address
screen, enter the IPv4 IP address of any one of the iSCSI host port of the array that the host can connect to or enter the IPv6 local address of the any of the iSCSI host port. Click
Next
to
continue.
6
In the
CHAP Configuration
screen, enter the CHAP secret if you have
configured a CHAP secret for the storage array.
Post Installation Tasks 45
Page 46
7
In the
Storage Array Login
screen, in the Controller# column, select the iSCSI host port of the storage array that needs to be configured and its IP address(es). In the
Host Address
column, from drop-down menu list, select
the host IP address that logs into the iSCSI host port of the storage array. See "Source Port Selection for iSCSI Host Ports" on page 46 for more
details about how these host IP addresses are listed in the drop-down menu and the recommended guidelines for selecting the host IP addresses.
Click
Next
to continue to enter the login information for another
controller or Click
8
In the
Connect to Additional Arrays
Apply
to commit the array login information.
screen, select whether you want to
connect to another storage array or not. If you want to connect to another storage array, repeat the above steps
starting from step 4 or step 5 depending on your last selection. If you do not want to connect to additional arrays, then click
Finish
on the
final screen to exit the utility.
Source Port Selection for iSCSI Host Ports
In order to establish data communication between a host and an iSCSI-based storage array, the iSCSI initiator on the host must be configured to establish iSCSI sessions to the iSCSI host ports of the storage array. The iSCSI port login screen allows you to specify the host and storage array IP addresses the iSCSI initiator uses to establish these iSCSI sessions.
Port Login Selection
Each iSCSI port for each controller in the storage array is presented with a list of host IP addresses through which the iSCSI initiator is able to login. The host IP addresses are the source IP addresses and the iSCSI port is the target.
Each list contains only the host IP addresses that are able to communicate with the associated iSCSI port. If none of the host IP addresses are able to communicate with an iSCSI port, Not Available is the only option shown for that iSCSI port. If none of the host IP addresses are able to communicate with any iSCSI ports of either storage array controller, the host configuration option is aborted for that storage array.
NOTE: The behavior described in the preceding paragraph does not apply to
Microsoft Windows Server 2003.
46 Post Installation Tasks
Page 47
For Microsoft Windows Server 2003, each list contains all available host IP addresses regardless of whether or not the address is able to communicate with the associated iSCSI port. You must select the appropriate host IP addresses for each iSCSI port.
Automatic Selection
NOTE: The contents in this section do not apply to Microsoft Windows Server 2003.
The utility attempts to automatically find and select the best possible configuration of host IP address(es) and storage array iSCSI ports for optimal performance and redundancy.
This automatic selection attempts to ensure that a host IP address (up to two IP addresses for PowerVault MD3000i storage arrays and up to four IP addresses for PowerVault MD3200i and MD3220i storage arrays) establishes an iSCSI session with each storage array controller and that the host IP address is logged into a maximum of one iSCSI port per controller. Configuration in this manner ensures redundancy and load balancing among the multiple host IP addresses (NICs).
The Do Not Connect option may be selected as the default option if the utility recommends not to connect to the iSCSI port. Also, even if the best recommended configuration is presented (whenever possible), you can still override this configuration by selecting the other host IP addresses from the drop-down list.
Suboptimal Configuration Warnings
In the following cases, a warning is displayed, that you must confirm, to continue:
The host IP addresses are selected in such a way that any host IP address establishes an iSCSI session with only one storage array controller in a dual controller (duplex) configuration.
The host IP addresses are selected in such a way that a host IP address establishes two or more iSCSI sessions with the same storage array controller.
Post Installation Tasks 47
Page 48

Post Connection Establishment Steps

After iSCSI connectivity is established between the host server(s) and the storage array, you can create virtual disks on the storage array using MDSM and these virtual disks can be utilized by the host server(s). For more information about storage planning and using MDSM, see the Owner’s Manual at support.dell.com/manuals.
48 Post Installation Tasks
Page 49
5

Guidelines for Configuring Your Network for iSCSI

This section provides general guidelines for setting up your network environment and IP addresses for use with the iSCSI ports on your host server and storage array. Your specific network environment may require different or additional steps than shown here, so make sure you consult with your system administrator before performing this setup.

Microsoft Windows Host Setup

To set up a Windows host network, you must configure the IP address and netmask of each iSCSI port connected to the storage array. The specific steps depend on whether you are using a Dynamic Host Configuration Protocol (DHCP) server, static IP addressing, Domain Name System (DNS) server, or Windows Internet Name Service (WINS) server.
NOTE: The server IP addresses must be configured for network communication to
the same IP subnet as the storage array management and iSCSI ports.
If you are using a DHCP server:
1
In the
Control Panel
Sharing Center
2
Right-click the network connection you want to configure and select
Properties
3
On the (for all other connections), select click
4
Select
If you are using static IP addressing:
1
In the
Center
2
Right-click the network connection you want to configure and select
Properties
General
Properties
Obtain an IP address automatically
Control P anel
and then click
.
, select
and then click
.
tab (for a local area connection) or the
.
, select
Network connections
Manage network connections
Internet Protocol (TCP/IP)
Network connections
Manage network connections
or
, then click OK.
or
Network and
.
Networking
Network and Sharing
.
tab
, and then
Guidelines for Configuring Your Network for iSCSI 49
Page 50
3
On the (for all other connections), select click
4
Select
General
Properties
tab (for a local area connection) or the
.
Use the following IP address
Networking
Internet Protocol (TCP/IP)
, and then
and enter the IP address, subnet mask,
and default gateway addresses.
If you are using a DNS server:
1
In the
Control P anel
Center
and then click
2
Right-click the network connection you want to configure and select
Properties
3
On the
.
General
(for all other connections), select click
Properties
4
Select
Obtain DNS server address automatically
and alternate DNS server IP addresses and click
, select
Network connections
Manage network connections
or
Network and Sharing
.
tab (for a local area connection) or the
Internet Protocol (TCP/IP)
.
or enter the preferred
OK
.
Networking
, and then
If you are using a WINS server:
NOTE: If you are using a DHCP server to allocate WINS server IP addresses, you
do not need to add WINS server addresses.
1
In the
Control Panel
2
Right-click the network connection you want to configure and select
Properties
3
On the
.
General
(for all other connections), select click
Properties
4
Select
Advanced
5
In the
TCP/IP WINS server
server and click
6
T o enable use of the Lmhosts file to r esolve remote NetBIOS names, select
Enable LMHOSTS lookup
, select
Network connections
.
tab (for a local area connection) or the
Internet Protocol (TCP/IP)
.
WINS
tab and click
Add
.
window, type the IP address of the WINS
Add
.
.
Networking
, and then
tab
tab
tab
50 Guidelines for Configuring Your Network for iSCSI
Page 51
7
To specify the location of the file that you want to import into the Lmhosts file, select
Open
dialog box.
8
Enable or disable NetBIOS over TCP/IP.
If using Microsoft Windows Server 2008 Core Version, use the netsh interface command to configure the iSCSI ports on the host server.
Import LMHOSTS
and then select the file in the

Linux Host Setup

To set up a Linux host network, you must configure the IP address and netmask of each iSCSI port connected to the storage array. The specific steps depend on whether you are configuring TCP/IP using DHCP or configuring TCP/IP using a static IP address.
NOTE: The server IP addresses must be configured for network communication to
the same IP subnet as the storage array management and iSCSI ports.
If you are using DHCP (root users only):
1
Edit the
NETWORKING=yes HOSTNAME=mymachine.mycompany.com
2
Edit the configuration file for the connection you want to configure, either
/etc/sysconfig/network-scripts/ifcfg-ethX
or Enterprise Linux).
/etc/sysconfig/network
/etc/sysconfig/network/ifcfg-eth-id-XX:XX:XX:XX:XX
file:
(for Red Hat Enterprise Linux)
(for SUSE
BOOTPROTO=dhcp
Also, verify that an IP address and netmask are not defined.
3
Restart network services using the following command:
/etc/init.d/network restart
Guidelines for Configuring Your Network for iSCSI 51
Page 52
If you are using a static IP address (root users only):
1
Edit the /
NETWORKING=yes HOSTNAME=mymachine.mycompany.com GATEWAY=255.255.255.0
2
Edit the configuration file for the connection you want to configure, either
/etc/sysconfig/network-scripts/ifcfg-ethX
or /etc/sysconfig/network/ifcfg-eth-id-XX:XX:XX:XX:XX (for SUSE Enterprise Linux).
BOOTPROTO=static BROADCAST=192.168.1.255 IPADDR=
192.168.1.100 NETMASK=255.255.255.0 NETWORK=
192.168.1.0 ONBOOT=yes TYPE=Ethernet HWADDR=XX:XX:XX:XX:XX:XX GATEWAY=192.168.1.1
3
Restart network services using the following command:
/etc/init.d/network restart
etc/sysconfig/network
file as follows:
(for Red Hat Enterprise Linux)
52 Guidelines for Configuring Your Network for iSCSI
Page 53
6

Uninstalling PowerVault MD Storage Software

Uninstalling Dell PowerVault MD Storage Software From Windows

Use the Change/Remove P rogram feature to uninstall Dell PowerVault Modular Disk Storage Software from Microsoft Windows operating systems other than Microsoft Windows Server 2008:
1
From the
2
Select
3
Click The
4
Follow the instructions on screen.
5
Select
Use the following procedure to uninstall Modular Disk Storage software from Windows Server 2008 GUI versions:
1
From the
2
Select
3
Click The
Control Panel,
Dell MD32
Change/Remove
Uninstall Complete
Yes
to restart the system, and then click
Control Panel
MD Storage Software
Uninstall/Change
Uninstall Complete
double-click
xxi Storage Software
.
window appears.
, double-click
from the list of programs.
.
window appears.
Add or Remove Programs
from the list of programs.
Done
.
Programs and Features
.
.
4
Select
Yes
to restart the system, then click Done.
Use the following procedure to uninstall Modular Disk Storage Software on Windows Server 2008 Core versions:
1
Navigate to the
Software
Dell\MD Storage Software\Uninstall Dell 32xxi Storage
directory.
Uninstalling PowerVault MD Storage Software 53
Page 54
NOTE: By default, Dell PowerVault MD Storage Manager is installed in the
\Program Files\Dell\MD Storage Software directory. If another directory was used during installation, navigate to that directory before beginning the uninstallation procedure.
2
From the installation directory, type the following command and press <Enter>:
Uninstall Dell MD Storage Software
3
From the screen.
4
Select
Uninstall
Yes
to restart the system, then click
window, click
Next
and follow the instructions on the
Done
.

Uninstalling PowerVault MD Storage Software From Linux

1
By default, PowerVault MD Storage Manager is installed in the
/opt/dell/mdstoragemanager/Uninstall Dell MD32xxi Storage Software
directory. If another directory was used during installation, navigate to that directory before beginning the uninstallation procedure.
2
From the installation directory, open the
Software
3
Run the file
4
From the screen.
While the software is uninstalling, the When the uninstall procedure is complete, the
window
directory.
Uninstall Dell MD Storage
Uninstall
is displayed.
window, click
Uninstall Dell MD Storage
.
Next
, and follow the instructions on the
Uninstall
window is displayed.
Uninstall Complete
5
Click
Done
.
54 Uninstalling PowerVault MD Storage Software
Page 55
A
Appendix—Manual Configuration of iSCSI
The following sections contain step-by-step instructions for configuring iSCSI on your storage array. However, before beginning, it is important to understand where each of these steps occur in relation to your host server or storage array environment.
Table A-1 below shows each iSCSI configuration step and where it occurs.
Table A-1. Host Server Vs. Storage Array
This Step is Performed on the Host Server Using the Microsoft or Linux iSCSI Initiator
3
Perform tar get discovery fro m the iSCSI initiator
6
(Optional) Configure CHAP authentication on the host server
7
Connect to the storage array from the host server
This Step is Performed on the Storage Array Using PowerVault MD Storage Manager
1
Discover the storage array
2
Configure the iSCSI ports on the storage array
4
Configure host access
5
(Optional) Configure CHAP authentication on the st or age array
8
(Optional) Set up in-band management
Appendix—Manual Configuration of iSCSI 55
Page 56

Step 1: Discover the Storage Array (Out-of-band Management Only)

Default Management Port Settings

By default, the storage array management ports are set to Dynamic Host Configuration Protocol (DHCP). If the controllers on your storage array are unable to get IP configuration from a DHCP server, it times out after 10 seconds and falls back to a default static IP address. The default IP configuration is:
Controller 0: IP: 192.168.128.101 Subnet Mask:
255.255.255.0 Controller 1: IP: 192.168.128.102 Subnet Mask:
255.255.255.0
NOTE: No default gateway is set.
NOTE: If DHCP is not used, initial configuration using the management station must
be performed on the same phy s ical subnet as the storage array. Additionally, during initial configuration, at least one network adapter must be configured on the same IP subnet as the storage array’s default management port (192.168.128.101 or
192.168.128.102). After initial configuration (management ports are configured using PowerVault MD Storage Manager), the management station’s IP address can be changed back to its previous settings.
NOTE: This procedure applies to out-of-band management only. If you choose to
set up in-band management, you must complete this step and then see "Step 8: (Optional) Set Up In-Band Management" on page74.
You can discover the storage array either automatical ly or manually. Select one and complete the steps below.
56 Appendix—Manual Configuration of iSCSI
Page 57

Automatic Storage Array Discovery

1
Launch MD Storage Manager (MDSM). If this is the first storage array to be set up, the
window is displayed.
2
Select
Automatic
It may take several minutes for the discovery process to complete. Closing the discovery status window before the discovery process completes cancels the discovery process.
and click OK.
Add New Storage Array
After discovery is complete, a confirmation screen is displayed. Click to close the screen.

Manual Storage Array Discovery

1
Launch MDSM. If this is the first storage array to be set up, the
window is displayed.
2
Select
Manual
3
Select Out-of-band management and enter the host server name(s) or IP address(es) of the iSCSI storage array controller.
4
Click
Add
Out-of-band management should now be successfully configured. After discovery is complete, a confirmation screen is displayed. Click
to close the screen.
and click OK.
.
Add New Storage Array

Setting Up the Array

1
When discovery is complete, the name of the first storage array found is displayed under the
2
The default name for the newly discovered storage array is another name is displayed, click the down arrow next to that name and select
Unnamed
3
Click the installation tasks. For more information about each task, see the
Manual
Initial Setup Tasks
. Perform these tasks in the order shown in Table 4-3.
Summary
in the drop-down list.
tab in MDSM.
option to see links to the remaining post-
Unnamed
Close
Close
. If
Owner’s
Appendix—Manual Configuration of iSCSI 57
Page 58
NOTE: Before configuring the storage array, check the status icons on the
Summary tab to ensure that the enclosures in the storage array are in an Optimal status. For more information on the status icons, see the Owner’s Manual at support.dell.com/manuals.
Table A-2. Initial Setup Tasks Dialog Box
Task Purpose
Rename the storage array To provide a more meaningful name than the
software-assigned label, Unnamed.
Set a storage array password T o restrict un authorized access. MDSM may ask
for a password before changing the configuration or performing a destructive operation.
Set up alert notifications Set up e-mail alerts Set up SNMP alerts
Configure a storage array To create virtual disks and map them to hosts.
To notify individuals (by e-mail) and/or storage enterprise management consoles, such as Dell Management Console, (by SNMP) when a storage array component degrades or fails, or an adverse environmental condition occurs.

Step 2: Configure the iSCSI Ports on the Storage Array

By default, the iSCSI ports on the storage array are set to the following IPv4 settings:
Controller 0, Port 0: IP: 192.168.130.101 Subnet Mask:
255.255.255.0 Port: 3260 Controller 0, Port 1: IP: 192.168.131.101 Subnet Mask:
255.255.255.0 Port: 3260 Controller 0, Port 2: IP: 192.168.132.101 Subnet Mask:
255.255.255.0 Port: 3260 Controller 0, Port 3: IP: 192.168.133.101 Subnet Mask:
255.255.255.0 Port: 3260 Controller 1, Port 0: IP: 192.168.130.102 Subnet Mask:
255.255.255.0 Port: 3260
58 Appendix—Manual Configuration of iSCSI
Page 59
Controller 1, Port 1: IP: 192.168.131.102 Subnet Mask:
255.255.255.0 Port: 3260 Controller 1, Port 2: IP: 192.168.132.102 Subnet Mask:
255.255.255.0 Port: 3260 Controller 1, Port 3: IP: 192.168.133.102 Subnet Mask:
255.255.255.0 Port: 3260
NOTE: No default gateway is set.
To configure the iSCSI ports on the storage array:
1
From MDSM navigate to the
Ethernet management ports
2
Configure the iSCSI ports on the storage array.
NOTE: Using static IPv4 addressing is recommended, although DHCP is supported.
Setup
tab on the AMW. Click
and then select
configure
Configure iSCSI Host Ports
The following settings are available (depending on your specific configuration) by clicking the
Advanced
button:
Virtual LAN (VLAN) support—A VLAN is a network of different
systems that behave as if they are connected to the same segments of a local area network (LAN) and are supported by the same switches and routers. When configured as a VLAN, a device can be moved to another location without being reconfigured. To use VLAN on your storage array, obtain the VLAN ID from your network administrator and enter it here.
Ethernet priority—This parameter is set to determine a network
access priority.
TCP listening port—The port number on the storage array listens for
iSCSI logins from host server iSCSI initiators.
.
NOTE: The TCP listening port for the iSNS server is the port number the
storage array controller uses to connect to an iSNS server. This allows the iSNS server to register the iSCSI target and portals of the storage array so that the host server initiators can identify them.
Jumbo frames—Jumbo Ethernet frames are created when the
maximum transmission units (MTUs) are larger than 1500 bytes per frame. This setting is adjustable port-by-port.
Appendix—Manual Configuration of iSCSI 59
Page 60
3
To enable ICMP PING responses for all ports, select
responses.
4
Click
OK
when all iSCSI storage array port configurations are complete.
5
T est the connection by performing a ping command on each iSCSI storage array port.
Enable ICMP PING

Step 3: Perform Target Discovery From the iSCSI Initiator

This step identifies the iSCSI ports on the storage array to the host server. Select the set of steps in one of the following sections (Microsoft Windows or Linux) that corresponds to your operating system.
If you are using Microsoft Windows Server 2003 or Windows Server 2008 GUI version:
1
Click
StartProgramsMicrosoft iSCSI Initiator
Programs
2
Click the
3
Under the iSCSI port on the storage array.
4
If the iSCSI storage array uses a custom TCP port, change the number. The default is 3260.
5
Click

Administrative ToolsiSCSI Initiator
Discovery
Target Portals
Advanced Local Adapter Source IP
with.
Data Digest and Header Digest
digest of data or header information be compiled during transmission to assist in troubleshooting.
CHAP logon information
enter CHAP information at this point, unless you are adding the storage array to a SAN that has target CHAP already configured.
tab.
, click
Add
and enter the IP address or DNS name of
and set the following values on the
—Must be set to Microsoft iSCSI Initiator.
—The source IP address of the host you want to connect
—Optionally, you can specify that a
—Leave this option unselected and do not
or click
.
General
StartAll
Port
tab:
NOTE: IPSec is not supported.
60 Appendix—Manual Configuration of iSCSI
Page 61
6
Click OK to exit the
Target Portals
7
To exit the
Discovery
screen.
Advanced
menu and click OK again to exit the
tab, click OK.
Add
If you plan to configure CHAP authentication, do not perform discovery on more than one iSCSI port at this point. Go to "Step 4: Configure Host Access" on page 62.
If you do not plan to configure CHAP authentication, repeat step1 thorough step 6 for all iSCSI ports on the storage array.
If you are using Windows Server 2008 Core Version:
1
Set the iSCSI initiator service to start automatically:
sc \\<server_name> config msiscsi start= auto
2
Start the iSCSI service:
3
Add a target portal:
sc start msiscsi
iscsicli QAddTargetPortal <IP_address_of_iSCSI_port_on_storage array>
If you are using Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6, SUSE Linux Enterprise Server 10, or SUSE Linux Enterprise Server 11:
Configuration of the iSCSI initiator for Red Hat Enterprise Linux 5 and SUSE Linux Enterprise Server 10 SP1 distributions is done by modifying the /etc/iscsi/iscsid.conf file, which is installed by default when you install MDSM. You can edit the file directly, or replace t he defaul t file wi th a sampl e file included on the PowerVault MD series resource media.
To use the sample file included on the media:
1
Save the default
/etc/iscsi/iscsid.conf
file by naming it to another name of
your choice.
2
Copy the appropriate sample file from
/etc/iscsi/iscsid.conf
3
Rename the sample file to
4
Edit the following entries in the
a
Edit or verify that the
b
Edit or verify that the
.
iscsid.conf
node.startup = manual node.startup = automatic
/linux/etc
on the media to
.
/etc/iscsi/iscsid.conf
file:
line is disabled.
line is
enabled. This enables automatic startup of the service at boot time.
Appendix—Manual Configuration of iSCSI 61
Page 62
c
Verify that the following time-out value is set to 30:
node.session.timeo.replacement_timeout = 30
d
Save and close the
5
From the console, restart the iSCSI service with the following command:
service iscsi start
6
Verify that the iSCSI service is running during boot using the following command from the console:
chkconfig iscsi on
7
To display the available iSCSI targets at the specified IP address, use the following command:
iscsiadm –m discovery –t st -p <IP_address_of_iSCSI_port>
8
After target discovery, use the following command to manually log in:
iscsiadm -m node –l
This log in is performed automatically at startup if automatic startup is enabled.
9
Manually log out of the session using the following command:
iscsiadm -m node -T <initiator_username> -p <target_ip> -u
/etc/iscsi/iscsid.conf
file.

Step 4: Configure Host Access

This step specifies which host servers access virtual disks on the storage array. You should perform this step:
Before mapping virtual disks to host servers
Any time you connect new host servers to the storage array
1
Launch MDSM.
2
Navigate to the AMW and click
3
At
Enter host name
This can be an informal name, not necessarily a name used to identify the host server to the network.
4
Select a method for adding the host port identifier.
62 Appendix—Manual Configuration of iSCSI
, enter the host server for virtual disk mapping.
Manually define hosts
.
Page 63
5
Select the host type.
6
Select whether or not the host server will be part of a host server group that shares access to the same virtual disks as other host servers. Select if the host is part of a Microsoft cluster.
7
Click
Next
.
8
Specify if this host will be part of a host group.
9
Click
Finish
.
Yes
only

Understanding CHAP Authentication

What is CHAP?

Challenge Handshake Authentication Protocol (CHAP) is an optional iSCSI authentication method where the storage array (target) authenticates iSCSI initiators on the host server. Two types of CHAP are supported
•Target CHAP
Mutual CHAP

Target CHAP

In target CHAP, the storage array authenticates all requests for access issued by the iSCSI initiator(s) on the host server using a CHAP secret. To set up target CHAP authentication, you must enter a CHAP secret on the storage array, then configure each iSCSI initiator on the host server to send that secret each time it attempts to access the storage array.

Mutual CHAP

In addition to setting up target CHAP, you can set up mutual CHAP in which both the storage array and the iSCSI initiator authenticate each other . To set up mutual CHAP, configure the iSCSI initiator with a CHAP secret that the storage array must send to the host sever in order to establish a connection. In this two-way authentication process, both the host server and the storage array send information that the other must validate before a connection is allowed.
Appendix—Manual Configuration of iSCSI 63
Page 64
CHAP is an optional feature and is not required to use iSCSI. However, if you do not configure CHAP authentication, any host server connected to the same IP network as the storage array can read from and write to the storage array.
NOTE: When using CHAP authentication, you should configure it on both the
storage array (using MDSM) and the host server (using the iSCSI initiator) before preparing virtual disks to receive data. If you prepare disks to receive data before you configure CHAP authentication, you lose visibility to the disks once CHAP is configured.

CHAP Definitions

To summariz e the differences between target CHAP and mutual CHAP authentication, see Table A-3.
Table A-3. CHAP Types Defined
CHAP Type Description
Target CHAP Sets up accounts that iSCSI initiators use to connect to the
target storage array. The target storage array then authenticates the iSCSI initiator.
Mutual CHAP Applied in addition to target CHAP, mutual CHAP sets up an
account that a target storage array uses to connect to an iSCSI initiator. The iSCSI initiator then authenticates the target.

Step 5: Configure CHAP Authentication on the Storage Array (Optional)

If you are configuring CHAP authentication of any kind (either tar get-only or target and mutual), you must complete this step and "Step 5: Configure CHAP Authentication on the Storage Arra y (O ptional)" on page 64.
If you are not configuring any type of CHAP, skip these steps and go to "Step 7: Connect to the Target Storage Array From the Host Server" on page70.
NOTE: If you choose to configure mutual CHAP authentication, you must first
configure target CHAP.
In terms of iSCSI configuration, the term target always refers to the storage array.
64 Appendix—Manual Configuration of iSCSI
Page 65

Configuring Target CHAP Authentication on the Storage Array

1
From MDSM, click the
Authentication
.
Select one of the CHAP settings described in Table A-4.
Table A-4. CHAP Setting
Option Description
None This is the default selection. If None is the only selection, the
storage array allows an iSCSI initiator to log on without supplying any type of CHAP authentication.
None and CHAP The storage array allows an iSCSI initiator to log on with or
without CHAP authentication.
CHAP If CHAP is selected and None is deselected, the storage array
requires CHAP authentication before allowing access.
2
To configure a CHAP secret, select
3
Enter the in
Confirm Target CHAP Secret
Target CHAP Secret (or Generate Random Secret)
Although the storage array allows sizes from 12 to 57 characters, many initiators only support CHAP secret sizes up to 16 characters (128-bit).
NOTE: A CHAP secret is not retrievable after it is entered. Ensure that you
record the secret in an accessible place. If Generate Random Secret is used, copy and paste the secret into a text file for future reference since the same CHAP secret is used to authenticate any new host servers you may add to the storage array. If you forget this CHAP secret, you must disconnect all existing hosts attached to the storage array and repeat the steps in this chapter to re-add them.
4
Click OK.
iSCSI
tab and then click
CHAP
and click
Change Target
and select
OK
.
CHAP Secret
. Confirm it
.
Appendix—Manual Configuration of iSCSI 65
Page 66

Configuring Mutual CHAP Authentication on the Storage Array

The initiator secret must be unique for each host server that connects to the storage array and must not be the same as the target CHAP secret.
Change the initiator authentication settings in the Change Target Authentication window. Use these options to change the settings:
None
—Select
None
, any initiator can access this target. Use this option only if you do not require secur e data . How ever, you can select both the same time.
CHAP
—Select access the target to authenticate using CHAP. Define the CHAP secret only if you want to use mutual CHAP authentication. If you select and if no CHAP target secret is defined, an error message is displayed. Click
CHAP Secret
window to define the CHAP secrets.
NOTE: To remove a CHAP secret, you must delete the host initiator and re-add it.
None
if you permit no initiator authentication. If you select
None
and
CHAP
if you want to enable an initiator that tries to
to view the
Enter CHAP Secre
t windows. Use this
CHAP
CHAP
at

Step 6: Configure CHAP Authentication on the Host Server (Optional)

If you configured CHAP authentication in "Step 5: Configure CHAP Authentication on the Storage Array (Optional)" on page 64, complete the following steps. If not, skip to "Step 7: Connect to the Target Storage Array From the Host Server" on page 70.
Select the set of steps in one of the following sections (Windows or Linux) that corresponds to your operating system.
If you are using Windows Server 2008 GUI version:
1
Click
Start
Programs
2
If you are not using mutual CHAP authentication, go to the step 4.
3
If you are using mutual CHAP authentication, click the select entered for the storage array
4
Click the
Programs
Administrative Tools
Secret
. At
Enter a secure secret
Discovery
tab.
Microsoft iSCSI Initiator
iSCSI Initiator
, enter the mutual CHAP secret you
or click
.
General
Start
tab and
All
,
66 Appendix—Manual Configuration of iSCSI
Page 67
5
Under
Target Portals
array and click
, select the IP address of the iSCSI port on the storage
Remove
.
The iSCSI port you configured on the storage array during target discovery disappears.
6
Under
Target Portals
, click
Add
and re-enter the IP address or DNS name
of the iSCSI port on the storage array (removed above).
7
Click
Advanced
and set the following values on the
General
tab:
Local Adapter—Should always be set to Microsoft iSCSI Initiator.
Source IP—The source IP address of the host you want to connect with.
Data Digest and Header Digest—Optionally, you can specify that a digest of data or header information be compiled during transmission to assist in troubleshooting.
CHAP logon information—Enter the target CHAP authentication user name and secret you entered (for the host server) on the storage array.
Perform mutual authentication—If mutual CHAP authentication is configured, select this option.
NOTE: IPSec is not supported.
8
Click OK. If you require a discovery session failover, repeat step 5 and step 6 (in this
step) for all iSCSI ports on the storage array. Otherwise, single-host port configuration is sufficient.
NOTE: If the connection fails, ensure that all IP addresses are entered correctly.
Mistyped IP addresses result in connection problems.
If you are using Windows Server 2008 Core version:
1
Set the iSCSI initiator services to start automatically (if not already set):
sc \\<server_name> config msiscsi start= auto
2
Start the iSCSI service (if necessary):
3
If you are not using mutual CHAP authentication, go to step 5.
4
Enter the mutual CHAP secret you entered for the storage array:
iscsicli CHAPSecret <secret>
Appendix—Manual Configuration of iSCSI 67
sc start msiscsi
Page 68
5
Remove the target portal that you configured on the storage array during target discovery:
iscsicli RemoveTargetPortal <IP_address> <TCP_listening_port>
6
Add the target portal with CHAP defined:
iscsicli QAddTargetPortal <IP_address_of_iSCSI_port_on_storage_array> [CHAP_username]
[CHAP_password]
where, [CHAP_username] is the initiator name and [CHAP_password] is the target CHAP secret.
If you require a discovery session failover, repeat step 5 for all iSCSI ports on the storage array. Otherwise, single-host port configuration is sufficient.
If you are using Red Hat Enterprise Linux 5, Red Hat Enterprise Linux 6, SUSE Linux Enterprise Server 10, or SUSE Linux Enterprise Server 11:
1
To enable CHAP (optional), the following line needs to be enabled in your
/etc/iscsi/iscsid.conf
node.session.auth.authmethod = CHAP
2
To set a user name and password for CHAP authentication of the initiator by the target(s), edit the following lines:
node.session.auth.username = <iscsi_initiator_username>
file:
node.session.auth.password = <CHAP_initiator_password>
3
If you are using Mutual CHAP authentication, you can set the user name and password for CHAP authentication of the target(s) by the initiator by editing the following lines:
node.session.auth.username_in= <iscsi_target_username>
node.session.auth.password_in = <CHAP_target_password>
68 Appendix—Manual Configuration of iSCSI
Page 69
4
To set up discovery session CHAP authentication, first uncomment the following line:
discovery.sendtargets.auth.authmethod = CHAP
5
Set a user name and password for a discovery session CHAP authentication of the initiator by the target(s) by editing the following lines:
discovery.sendtargets.auth.username = <iscsi_initiator_username>
discovery.sendtargets.auth.password = <CHAP_initiator_password>
6
To set the user name and password for discovery session CHAP authentication of the target(s) by the initiator for Mutual CHAP, edit the following lines:
discovery.sendtargets.auth.username = <iscsi_target_username>
discovery.sendtargets.auth.password_in = <CHAP_target_password>
7
The final configuration contained in the
/etc/iscsi/iscsid.conf
file might
look like this:
node.session.auth.authmethod = CHAP node.session.auth.username = iqn.2005-
03.com.redhat01.78b1b8cad821
node.session.auth.password = password_1 node.session.auth.username_in= iqn.1984-
05.com.dell:powervault.123456
node.session.auth.password_in = test1234567890 discovery.sendtargets.auth.authmethod = CHAP discovery.sendtargets.auth.username = iqn.2005-
03.com.redhat01.78b1b8cad821
discovery.sendtargets.auth.password = password_1
Appendix—Manual Configuration of iSCSI 69
Page 70
discovery.sendtargets.auth.username = iqn.1984-
05.com.dell:powervault.123456 discovery.sendtargets.auth.password_in =
test1234567890
If you are using SUSE Linux Enterprise Server SP3 using the GUI:
1
Click
DesktopYaSTiSCSI Initiator
2
Click
Service Start
3
Select
Discovered Targets
4
Enter the IP address of the port.
5
Click
Next
.
6
Select any target that is not logged in and click
7
Select one:
If you are not using CHAP authentication, select Go to step 8.
or
If you are using CHAP authentication, enter the CHAP user name and password. To enable Mutual CHAP, select and enter the Mutual CHAP user name and password.
8
Repeat step 7 for each target until at least one connection is logged in for each controller.
9
Go to
Connected Targets
10
Verify that the targets are connected and displays a status of
, then select
, then select
.
When Booting
.
.
Discovery
.
Log in
.
No Authentication
true
.
.

Step 7: Connect to the Target Storage Array From the Host Server

If you are using Windows Server 2008 GUI:
Click
1
2
70 Appendix—Manual Configuration of iSCSI
Start
Programs
Click the If previous target discovery was successful, the iqn of the storage array
should be displayed under Targets.
Programs
Administrative Tools
Targets
tab.
Microsoft iSCSI Initiator
iSCSI Initiator
or click
.
Start
All
Page 71
3
Click
4 5 6
Select Select Click
Log On
Advanced
.
Automatically restore this connection when the system boots Enable multi-path
and configure the following settings under the
.
General
tab:
Local Adapter
Source IP
—Must be set to
Microsoft iSCSI Initiator
.
—The source IP address of the host server you want to
connect from.
Target Portal
—Select the iSCSI port on the storage array controller
that you want to connect to.
Data Digest and Header Digest
—Optionally, you can specify that a digest of data or header information be compiled during transmission to assist in troubleshooting.
CHAP logon information
—If CHAP authentication is required,
select this option and enter the Target secret.
Perform mutual authentication
—If mutual CHAP authentication is configured, select this option.
NOTE: IPSec is not supported.
7
Click OK. To support storage array controller failover, the host server must be
connected to at least one iSCSI port on each controller. Repeat step3 through step 8 for each iSCSI port on the storage array that you want to establish as failover targets. The
Target Portal
address is different for each
port you connected to.
.
NOTE: To enable the higher throughput of multipathing I/O, the host server
must connect to both iSCSI ports on each controller, ideally from separate host-side NICs. Repeat step 3 through step7 for each iSCSI port on each controller. If using a duplex PowerVault MD32xxi configuration, then LUNs should also be balanced between the controllers.
The
Status
field on the
8
Click OK to close the Microsoft iSCSI initiator.
NOTE: PowerVault MD32xxi supports only round robin load-balancing
policies.
Targets
tab should now display as
Appendix—Manual Configuration of iSCSI 71
Connected
.
Page 72
If you are using Windows Server 2008 Core Version:
1
Set the iSCSI initiator services to start automatically (if not already set):
sc \\<server_name> config msiscsi start= auto
2
Start the iSCSI service (if necessary):
3
Log on to the target:
sc start msiscsi
iscsicli PersistentLoginTarget <Target_Name> <Report_To_PNP> <Target_Portal_Address> <TCP_Port_Number_Of_Target_Portal> * * *
<Login_Flags> * * * * * <Username> <Password> <Authtype> * <Mapping_Count>
where –
<Target_Name>
is the target name as displayed in the target list. Use
the iscsicli ListTargets command to display the target list.
<Report_To_PNP>
is T, which exposes the LUN to the operating
system as a storage device.
<Target_Portal_Address>
is the IP address of the iSCSI port on the
controller being logged in to.
<TCP_Port_Number_Of_Target_Portal>
<Login_Flags>
is 0x2 to enable multipathing for the target on the
is 3260.
initiator. This value allows more than one session to be logged in to a target at one time.
<Username> <Password>
– –
<Authtype>
is the initiator name.
is the target CHAP secret.
is either 0 for no authentication, 1 for Target CHAP, or 2
for Mutual CHAP.
: NOTE: <Username>, <Password> and <Authtype> are optional parameters.
They can be replaced with an asterisk (*) if CHAP is not used.
<Mapping_Count>
is 0, indicating that no mappings are specified
and no further parameters are required.
* * * An asterisk (*) represents the default value of a parameter.
72 Appendix—Manual Configuration of iSCSI
Page 73
For example, your log on command might look like this:
iscsicli PersistentLoginTarget iqn.1984-
05.com.dell:powervault.6001372000ffe3332xx0000046 72edf2 3260 T 192.168.130.101 * * * 0x2 * * * * *
* * * * 0
To view ac t ive sessions to the target, run the following command:
iscsicli SessionList
To support storage array controller failover, the host server must be connected to at least one iSCSI port on each controller. Repeatstep 3 for each iSCSI port on the storage array that you want to establish as a failover target. The Target_ Portal_Address is different for each port you connect to.
PersistentLoginTarget does not initiate a login to the target until after the system is rebooted. To establish immediate lo gin to the target, substitute LoginTarget for PersistentLoginTarget.
: NOTE: See the Microsoft iSCSI Software Initiator 2.x User’s Guide for more
information about the commands used in the previous steps. For more information about Windows Server 2008 Server Core, see the Microsoft Developers Network (MSDN) at microsoft.com.
If you are using a Linux Server: In MDSM, the Configure iSCSI Host P orts displays the status of each iSCSI
port you attempt to connect and the configuration state of all IP addresses. If either displays Disconnected or Unconfigured, respectively, check the following and repeat the iSCSI configuration steps:
Are all cables securely attached to each port on the host server and storage array?
Is TCP/IP correctly configured on all target host ports?
Is CHAP set up correctly on both the host server and the storage array?
To review optimal network setup and configuration settings, see "Guidelines for Configuring Your Network for iSCSI" on page 49.
Appendix—Manual Configuration of iSCSI 73
Page 74

Step 8: (Optional) Set Up In-Band Management

Out-of-band management (see "Step 1: Discover the Storage Array (Out-of­band Management Only)" on page 56) is the recommended method for managing the storage array. However, to optionally set up in-band management, use the steps shown below.
The default iSCSI host port IPv4 addresses are shown below for reference: Controller 0, Port 0: IP: 192.168.130.101 Controller 0, Port 1: IP:
192.168.131.101 Controller 0, Port 0: IP: 192.168.132.101 Controller 0, Port 1: IP:
192.168.133.101 Controller 1, Port 0: IP: 192.168.130.102 Controller 1, Port 1: IP:
192.168.131.102 Controller 1, Port 0: IP: 192.168.132.102 Controller 1, Port 1: IP:
192.168.133.102
NOTE: The management station you are using must be configured for network
communication to the same IP subnet as the PowerVault MD32xxi host ports.
1
Establish an iSCSI session to the PowerVault MD3200i RAID storage array .
2
Restart the
3
Launch MDSM. If this is the first storage array to be set up for management, the
Storage Array
SMagent
service.
window is displayed. Otherwise, click
New
Add New
.
4
Select
Manual
5
Select In-band management and enter the host server name(s) or IP address(es) of the host server that is running the PowerVault MD Storage Manager software.
6
Click
Add
In-band management should now be successfully configured.
74 Appendix—Manual Configuration of iSCSI
and click OK.
.
Page 75
B
Appendix—Using Internet Storage Naming Service
Internet Storage Naming Service (iSNS) server, supported only on Microsoft Windows iSCSI environments, el imina tes the need to manually configure each individual storage array with a specific list of initiators and target IP addresses. Instead, iSNS automatically discovers, manages, and configures all iSCSI devices in your environment.
For more information on iSNS, including installation and configuration, see microsoft.com.
Appendix—Using Internet Storage Naming Service 75
Page 76
76 Appendix—Using Internet Storage Naming Service
Page 77
C
Appendix—Load Balancing

Load Balance Policy

Multi-path drivers select the I/O path to a virtual disk through a specific RAID controller module. When the multi-path driver receives a new I/O to process, the driver tries to find a path to the current RAID controller module that owns the virtual disk. If the path to the current RAID controller module that owns the virtual disk cannot be found, the multi-path driver migrates the virtual disk ownership to the secondary RAID controller module. When multiple paths to the RAID controller module that owns the virtual disk exist, you can choose a load balance policy to determine which path is used to process I/O . Multiple options for setting the load balance policies let you optimize I/O performance when mixed host interfaces are configur ed.
You can choose one of the following load balance policies to optimize I/O performance:
Round robin with subset
Least queue depth with subset
Least path weight with subset (Windows operating systems only)

Round Robin With Subset

The round robin with subset I/O load balance policy routes I/O requests, in rotation, to each available data path to the RAID controller module that owns the virtual disks. This policy treats all paths to the RAID controller module that owns the virtual disk equally for I/O activity. P aths to the secondary RAID controller module are ignored until ownership changes. The basic assumption for the round-robin policy is that the data paths are equal. With mixed host support, the data paths might have different bandwidt hs or different data transfer speeds.
Appendix—Load Balancing 77
Page 78

Least Queue Depth With Subset

The least queue depth with subset policy is also known as the least I/Os or least requests policy. This policy routes the next I/O request to a data path that has the least outstanding I/O requests queued. For this policy, an I/O request is simply a command in the queue. The type of command or the number of blocks that are associated with the command are not considered.
The least queue depth with subset policy treats large block requests and small block requests equally. The data path selected is one of the paths in the path group of the RAID controller module that owns the virtual disk.

Least Path Weight With Subset

The least path weight with subset policy assigns a weight factor to each data path to a virtual disk. An I/O request is routed to the path with the lowest weight value to the RAID controller module that owns the virtual disk. If more than one data path to the virtual disk has the same weight value, the round-robin with subset path selection policy is used to route I/O requests between the paths with the same weight value. The least path weight with subset load balance policy is not supported on Linux operating systems.

Changing Load Balance Policies on the Windows Server 2008 Operating System

Load balancing with the MD3200i series storage array is only available for Windows Server 2008 and later versions of the operating syste m. You can change the load balance policies from the default round robin with subset by using either the:
•Device manager
Disk management
To change the load balance policy using Windows Server 2008 device manager:
1
From the desktop of the host, right-click
Manage
2
Click
3
Right-click on the multi-path disk device for which you want to set the load balance policies, then select
4
From the this disk device.
to open the
Device Manager
MPIO
Computer Management
tab, select the load balance policy that you want to set for
to show the list of devices attached to the host.
Properties
My Computer
dialog.
.
and select
78 Appendix—Load Balancing
Page 79
To change the load balance policy using Windows Server 2008 disk management:
1
From the desktop of the host, right-click to open the
2
Click host.
3
Right-click on the virtual disk for which you want to set the load balance policy, then click
From the MPIO tab, select the load balance policy that you want to set for this virtual disk.
Computer Management
Disk Management
Properties
to show the list of virtual disks attached to the
.
My Computer
dialog.
and click
Manage

Increasing Bandwidth With Multiple iSCSI Sessions

The PowerVault MD3200i series storage array in a duplex configuration supports two active/active asymmetric redundant controllers. Each controller has four 1 Gbps Ethernet ports that support iSCSI. The bandwidth of the four ports on the same controller can be aggregated to provide optimal performance. A host can be configured to simultaneously use the bandwidth of both the ports on a controller to access virtual disks owned by the controller. The multi-path failover driver that Dell provides for the MD3200i series storage array can be used to configure the storage array so that all ports are used for simultaneous I/O access. If the multi-path driver detects multiple paths to the same virtual disk through the ports on the same controller, it load-balances I/O access from the host across all ports on the controller.
Figur e C-1 illustrates how the initiator can be configured to take advantage of the load balancing capabilities of the multi-path failover driver.
Appendix—Load Balancing 79
Page 80
Figure C-1. Initiator Configuration
IP Addresses
Host If1: IP_Addr_If1 If2: IP_Addr_If2
MD32xxi Controller 0 P0: IP_Addr_C0_P0 P1: IP_Addr_C0_P1 P2: IP_Addr_C0_P2 P3: IP_Addr_C0_P3 MD32xxi Controller 1 P0: IP_Addr_C1_P0 P1: IP_Addr_C1_P1 P2: IP_Addr_C1_P2 P3: IP_Addr_C1_P3
TCP Connections
To MD32xxi Controller 0 T01: IP_Addr_If1 / IP_Addr_C0_P0 T02: IP_Addr_If2 / IP_Addr_C1_P1 T03: IP_Addr_If3 / IP_Addr_C1_P2 T04: IP_Addr_If4 / IP_Addr_C1_P3 To MD32xxi Controller 1 T11: IP_Addr_If1 / IP_Addr_C1_P0 T12: IP_Addr_If2 / IP_Addr_C1_P1 T13: IP_Addr_If3 / IP_Addr_C1_P2 T14: IP_Addr_If4 / IP_Addr_C1_P3
iSCSI Sessions
To MD32xxi Controller 0 Session 00: T01 Session 01: T02 Session 02: T03 Session 03: T04 To MD32xxi Controller 1 Session 10: T11 Session 11: T12 Session 12: T13 Session 14: T14
host server
IP network 1
Storage array
IP network 2
80 Appendix—Load Balancing
Page 81
Two sessions with one TCP connection are configured from the host to each controller (one session per port), for a total of four sessions. The multi-path failover driver balances I/O access across the sessions to the ports on the same controller. In a duplex configuration, with virtual disks on each controller, creating sessions using each of the iSCSI data ports of both controllers increases bandwidth and provides load balancing.
Appendix—Load Balancing 81
Page 82
82 Appendix—Load Balancing
Page 83
D
Appendix—Stopping and Starting iSCSI Services in Linux
To manually stop the iSCSI services in Linux, certain steps must be followed to maintain parallel processing between the storage array and the host server.
1
Stop all I/O.
2
Unmount all correlated file systems. Stop iSCSI service by running the following command:
/etc/init.d/open-iscsi stop
Appendix—Stopping and Starting iSCSI Services in Linux
Page 84
84 Appendix—Stopping and Starting iSCSI Services in Linux