DBX ZC-1, ZC-8 Users Manual

User Guide
ZC
Series
®
DriveRack
®
ZC Series Wall-Mounted Zone Controllers
ZC-1-4 ZC-6-9
ZC-Fire
ZC-BOB
DriveRack®/ZonePRO™User Manual
2
ZC-Remote Control Wall Controllers
USER GUIDE
DECLARATION OF
CONFORMITY
Manufacturer’s Name: dbx Professional Products Manufacturer’s Address: 8760 S. Sandy Parkway
Sandy,Utah 84070, USA
declares that the product:
Product name: dbx Zone Controllers Models: ZC1,2, 3, 4,6, 7,
8, 9,FIRE and BOB
Note: Product name may be suffixed by the letters -EU.
Product option: none
conforms to the following Product Specifications:
Safety: IEC 60065-98
EMC: EN 55013 (1990)
EN 55020 (1991)
Supplementary Information:
The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC as amended by Directive 93/68/EEC.
Vice-President of Engineering
8760 S. Sandy Parkway
Sandy,Utah 84070, USA Date: February 3,2003 Revised: September 10,2004
European Contact: Your local dbx Sales and Service Office or
Harman Music Group 8760 South Sandy Parkway Sandy,Utah 84070 USA Ph: (801) 566-8800 Fax: (801) 568-7583
The symbol shown above is an internationally accepted symbol that warn of potential hazards with electrical prod­ucts. The exclamation point in an equilateral triangle indi­cates that it is necessary for the user to refer to the owner’s manual.
®
Zone Controller Wiring
The Zone Controllers, (ZC-1, ZC-2, ZC-3, ZC-4, ZC-6, ZC-7, ZC-8, ZC-9, and ZC-Fire) can be wired serially or in parallel. To wire in series each Zone Controller must have an iden­tification or zone number chosen using the DIP switches on the side of the controller (see diagram A). Each controller must have a unique number chosen although there may be multiple Zone Controllers controlling a single zone, or a single Zone Controller that con­trols multiple outputs. The Zone Controllers can then be wired together and connected to the DriveRack 220i, 260 or ZonePRO units (see diagram B).
The Zone Controllers may also be wired in parallel with the use of the ZC-BOB. To wire in parallel (home run cabling), each controller must have a unique identification or num­ber chosen using the DIP switches on the rear of the panel (see diagram A). To wire in parallel, each controller must be wired into a port of the ZC-BOB with a connecting wire going to the DriveRack or ZonePro (see diagram C). Diagram D shows the typical wiring for ZC-4 Euroblock connections in which the installer needs to use SPDT (single-pole, dou­ble-throw) switches with one side being connected to 5 volts (+VREF) and the other side to ground (GND). Diagram E shows the proper way to interface the ZC-Fire to the fire alarm system. Use only the relay/switch closure or the 5-24V DC inputs. Do not use both inputs at the same time. For information regarding ZC setup, please see the respective manual for the Driverack or ZonePro unit that you are setting up.
Diagram A
RJ45
CONNECT
ONLYTO
ZONE CONTROLLERINP U
T
.
IEC60065
UL-6500
80-1342-A
RJ45
CONNECT
ONLY
TO
ZONE CONTROLLERINP U
T
.
IEC60065
UL-6500
80-1342-A
ID# 1 ID# 4
Diagram B
ZC-Remote Control Wall Controllers
USER GUIDE
DriveRack®/ZonePRO™User Manual
3
®