Datasheet NDY1215, NDY2409, NDY2405, NDY0515, NDY1212 Datasheet (cdtechno)

...
Page 1
www.cdpoweronline.com
SELECTION GUIDE
FEATURES
Industry Standard Footprint
Single Isolated Output
Short Circuit Protection
Operating Temperature Range
Low Profile 24 Pin Case
Efficiency to 82%
Power Density 0.90W/cm
3
2:1 Wide Input Range
5V, 12V, 24V & 48V Input
3.3V, 5V, 9V, 12V & 15V Output
Footprint 4.73cm
2
UL 94V-0 Package Materials
No Heatsink Required
Internal SMD Construction
Fully Encapsulated
Lead Free Compatible
DESCRIPTION
The NDY series is a range of low profile DC/DC converters offering a single regulated output over a 2:1 input voltage range. All parts deliver 3W output power up to 85°C without heatsinking, except the 4.5V to 9V input voltage range which should be derated to 2W at the lower input voltage. A flyback oscillator design with isolated feedback is used to give regulation over the full operating range of 25% to 100% of full load. It is strongly recommended that external capacitors be used on input and output to guarantee performance over full load and input voltage range (see recommended filter circuit for values). The plastic case and encapsulant materials are rated to UL 94V-0 and the connection pins are formed from a tin plated alloy 42 leadframe.
Nominal Rated
Input
Input Output
Output Current
4
Current
Voltage Voltage Min Load Full Load Full Load MTTF
3
Order Code (V) (V) (mA) (mA) (mA) (%) (pF) kHrs
NDY0505 55100 -150 400- 600 615 66 40 1939
NDY0509
5955-83 222-333 563 72 52 1926
NDY0512
5 12 42-62 166-250 548 71 43 1907
NDY0515
51533-50 133-200 533 73 44 1924
NDY1205
12 5 150 600 362 71 36 1928
NDY1209 12 9 83 333 320 78 52 1916 NDY1212 12 12 62 250 316 78 44 1897 NDY1215 12 15 50 200 308 79 47 1914 NDY2403 24 3.3 227 909 178 70 30 1671
NDY2405
24 5 150 600 174 70 36 1673
NDY2409
24 9 83 333 156 78 52 1663
NDY2412
24 12 62 250 154 80 44 1644
NDY2415
24 15 50 200 150 82 54 1657
NDY4803 48 3.3 227 909 87 71 30 1676 NDY4805 48 5 150 600 87 73 35 1668 NDY4809 48 9 83 333 78 80 52 1663 NDY4812 48 12 62 250 77 81 44 1648 NDY4815 48 15 50 200 76 81 53 1661
Min
Efficiency1Typical
Isolation
Capacitance
Parameter Conditions MIN TYP MAX Units
All NDY05XX 4.5 5 9
Voltage Range
All NDY12XX 9 12 18
VDC
All NDY24XX 18 24 36 All NDY48XX 36 48 72 NDY2403
2
180 360
NDY4803
2
140 290
Reflected
1
All NDY05XX 400 500
Ripple
All NDY12XX 150 170
mA p-p
Current
All other NDY24XX 290 360 All other NDY48XX 100 127
Short-circuit protection continuous Input voltage 05 types 10V Input voltage 12 types 20V Input voltage 24 types 40V Input voltage 48 types 80V Lead temperature 1.5mm from case for 10 seconds 300°C Minimum Load 25% of rated load Internal Dissipation 1.7W
INPUT CHARACTERISTICS
ABSOLUTE MAXIMUM RATINGS
1 Measured at full load with external input/output capacitors, refer to filter circuit 1. 2 For lower ripple refer to filter circuit 2. 3 Calculated using MIL-HDBK-217F with nominal input voltage at full load. 4 Refer to power derating graph.
All specifications typical at T
A
=25°C, nominal input voltage and rated output current unless otherwise specified.
NDY SERIES
Isolated 3W Wide Input DC/DC Converters
Page 2
Parameter Conditions MIN TYP MAX Units
Voltage Set Point Accuracy With external input/output capacitors, refer to filter circuits ±1 ±5 %
Low line to high line, 3.3V output with external input/output capacitors,
0.05 0.2 %
Line Regulation
refer to filter circuit 1 Low line to high line, with external input/output capacitors,
0.05 0.5 %
refer to filter circuit 1 25% load to 100% load, 3.3V output with external input/output capacitors,
0.6 0.5
%
Load Regulation
refer to filter circuit 1 25% load to 100% load, with external input/output capacitors,
0.2 0.5
%
refer to filter circuit 1 BW = 20Hz to 300kHz. 3.3V output with external input/output capacitors,
80 120 mV rms
Ripple
2
refer to filter circuit 1 BW = 20Hz to 300kHz. With external input/output capacitors,
510mV rms
refer to filter circuit 1 BW = DC to 100MHz. 3.3V output with external input/output capacitors,
180 mV p-p
Noise
refer to filter circuit 1 BW = DC to 100MHz. With external input/output capacitors,
50 100 mV p-p
refer to filter circuit 1
OUTPUT CHARACTERISTICS
www.cdpoweronline.com
1 Measured at full load with external input/output capacitors, refer to filter circuit 1. 2 For lower ripple refer to filter circuit 2. 3 Calculated using MIL-HDBK-217F with nominal input voltage at full load. 4 Refer to power derating graph.
All specifications typical at T
A
=25°C, nominal input voltage and rated output current unless otherwise specified.
NDY SERIES
Isolated 3W Wide Input DC/DC Converters
ISOLATION CHARACTERISTICS
GENERAL CHARACTERISTICS
Parameter Conditions MIN TYP MAX Units
Isolation Test Voltage Flash tested for 1 second 1000 VDC Resistance Viso=500VDC 1 G
Parameter Conditions MIN TYP MAX Units
100% load VINnominal 3.3V output 160 220
Switching Frequency
25% load VINnominal 3.3V output 290 560
kHz
100% load VINnominal 80 220 25% load VINnominal 290 560
Weight: 6.2g (3.3V O/P 6.7g)
PIN CONNECTIONS (TOP VIEW)
1.27 (32.26)
0.577
(14.66)
0.275 (7.00)
0.185 (4.70)
0.145 (3.70)
0.033 (0.84)
0.021 (0.54)
0.012 (0.30)
0.008 (0.20)
124
10 15 11 14 12 13
V
IN
0V +V GND
V
IN
0V +V
GND
0.10 (2.54)
1.10 (27.94) 0.644 (16.35) Max
MECHANICAL DIMENSIONS
Page 3
C&D Technologies (NCL) Ltd
Tanners Drive, Blakelands North Milton Keynes MK14 5BU, England Tel: +44 (0)1908 615232 Fax:+44 (0)1908 617545 email: info@cdtechno-ncl.com
www.cdpoweronline.com
C&D Technologies Inc.
3400 E Britannia Drive, Tucson, Arizona 85706, USA Tel: +1 (800) 547-2537 Fax: +1 (520) 741-4598 email: sales@cdtechno.com
C&D Technologies (NCL) Limited reserve the right to alter or improve the specification, internal design or manufacturing process at any time, without notice. Please check with your supplier or visit our web site to ensure that you have the current and complete specification for your product before use.
© C&D Technologies (NCL) Limited 2003 NDC NDY.3 No part of this publication may be copied, transmitted or stored in a
retrieval system or reproduced in any way including, but not limited to, photography, photocopy, magnetic or other recording means, without prior written permission from C&D Technologies (NCL) Limited.
Instructions for use are available from www.cdpoweronline.com
NDY SERIES
Isolated 3W Wide Input DC/DC Converters
ENVIRONMENTAL
NDY05 POWER DERATING CURVE
Parameter Conditions MIN TYP MAX Units
Operation -40 85 °C Storage -50 130 °C Cooling Free air convection
5
4
3
2
1
0
4.5 5 6 789 Input Voltage (V)
Output Power (W)
FILTER CIRCUITS
EXTERNAL CAPACITANCE
Although these converters will work without external capacitors, they are necessary in order to guarantee the full parametric performance over the full line and load range. All parts have been tested and characterised using the following values and test circuit.
OUTPUT LOAD
The minimum rated load across the whole input voltage range is 25% of the full load output. It is important to take care that the load does not fall below this as the output ripple will greatly increase. While this condition will not harm the device the resultant increase in output ripple could cause customers’ application to malfunction.
Value
CIN
10µF, 200V Philips Part Number 151621809 or any
good low esr capacitor
COUT
100µF, 25V
Philips Part Number
13556101 or any good
low esr capacitor
LOUT
C&D Technologies Part
No 24100
NDY
C
OUT
C
IN
V
IN
+V
OUT
GND OV
FILTER CIRCUIT 1
FILTER CIRCUIT 2
Recommended circuit for reduced ripple 3.3V O/P
NDY
C
IN
C
OUT
V
IN
+V
OUT
GND OV
L
OUT
Loading...