Statement of Responsibilities
This document is for use by experienced and trained Qualified Cleveland Range, LLC Authorized Service Representatives who are familiar with both the safety procedures, and equipment they service.
Cleveland Range, LLC assumes no liability for any death, injury, equipment damage, or property damage resulting from use of, improper use of, or failure to use the information contained in this document.
Cleveland Range, LLC has made every effort to provide accurate information in this document, but cannot guarantee that this document does not contain unintentional errors and omissions.
The information in this document may be subject to technical and technological changes, revisions, or updates.
Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or updates.
Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow industry standard safety procedures, including, but not limited to, OSHA regulations, and disconnect / lock out / tag out procedures for all utilities including steam, and disconnect / lock out / tag out procedures for gas, electric, and steam powered equipment and / or appliances
All utilities (gas, electric, water and steam) should be turned OFF to the equipment and locked out of operation according to OSHA approved practices during any servicing of Cleveland Range equipment
Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to maintain up-to-date knowledge, skills, materials and equipment.
SteamCraft ® Gemini TM 6
SHORT SERIES PRESSURELESS STEAMER, TWIN, INDEPENDENT GAS-FIRED GENERATORS
Cleveland Standard Features
■54.5” (1385mm) height to top of upper compartment (lower height makes maintenance easier by lowering the descaling ports)
■Each compartment has cooking capacity for 3 each 12˝ x 20˝ x 21⁄2˝ Steam Table Pans
■Doors hinged left and the controls on the right
■High efficiency independent Power Burner Steam Generators 50,000 BTU's for each compartment
■Each steam-cooking compartment is independently operated and controlled by a separate stainless steel steam generator, gas valve, Power On/Off Control Levers and a Exclusive, Remote Probe-Type Water Level Control
■Easy Access Cleaning Port: Each generator has a deliming port located on the outside, top of the unit
■Generator Cleaning Light for each compartment warns the operator to delime generator
■Generator Steam Standby Mode: Holds generator at a steaming temperature, allows unit to start cooking quickly
■Each compartment has one, 60-Minute Electro-Mechanical Timer with "SureCook" load compensating feature. Manual Bypass Switch for constant steaming.
■Durable 14 Gauge, 304 Stainless Steel construction for compartment door, cooking cavity and steam generator
■Exclusive Gemini Drain/Power Control System:
Manual 1/2 inch "Ball Valve" type drain that controls main power On/Off and automatically fills generator (located on the control panel)
■Exclusive Brass Steam Jets distribute steam even throughout cooking compartment
■Easy, Front -Access Generator Controls comes with a pullout drawer for simple servicing of unit
■6˝ Stainless Steel Adjustable Legs with Flanged Feet
■Approvals: CSA (AGA, CSA) and U.L/NSF#4
■Compartment Steam Shut-Off Switch when compartment door is opened
Options & Accessories
Electronic Timer with Compensating Feature (ETC)
On/Off Steam Switch Controls, no timer (MC)
Propane Gas (PG)
Cleveland Range, LLC
MODEL: 24CGA6.2S
ITEM NUMBER __________________________________________
JOB NAME / NUMBER __________________________________
Short Form Specifications
Cleveland SteamCraft GeminiTM Model 24CGA6.2S, 54.5" high, Two compartment steamer. Independent steam generators, 50,000 BTU's input per compartment. "SureCook" electro mechanical timer with load compensating feature. Gas valve and water level control system. Exclusive remote probe-type water level controls. Exclusive Brass “Steam Jet” distribution system. Twopiece free-floating compartment door. 14 gauge stainless steel cavity and door. Pullout service drawer for controls and Gemini Drain/Power Control System.
Dissolve ® Descale Solution, 6 one gallon container w/quart markings (106174)
Water Filters
SECT. IV PAGE 11 0104
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110
Ph: 1-216-481-4900 Fx: 1-216-481-3782
Visit our Web Site at www.clevelandrange.com
|
|
|
|
WATER QUALITY |
|
||||
|
|
|
|
REQUIREMENTS |
|
||||
|
|
|
|
The quality of water varies |
|||||
|
37.13" |
|
|
greatly |
from |
region |
to |
||
|
|
|
region. Steam equipment |
||||||
33.13" |
(943mm) |
|
|
||||||
|
|
|
generators |
|
must |
|
be |
||
(842mm) |
|
|
|
drained daily and chemi- |
|||||
D |
|
|
|
||||||
C2 C1 |
17.43" |
|
|
cally descaled periodically |
|||||
12.76" |
|
|
to ensure proper operation. |
||||||
(443mm) |
|
|
|||||||
(324mm) |
|
|
To minimize service prob- |
||||||
15.06" |
|
|
lems caused by the accu- |
||||||
(383mm) |
|
|
|||||||
|
|
|
|
mulation of minerals and |
|||||
5.00" |
4.00" |
|
|
chemicals in water review |
|||||
(127mm) |
(102mm) |
|
|
the following quality guide- |
|||||
4.87" |
|
|
|
||||||
|
3.00" TYP |
|
lines with |
a |
local |
water |
|||
(124mm) |
|
|
|||||||
|
(76mm) |
12.00" |
treatment specialist. Inlet |
||||||
7.75" |
|
||||||||
(197mm) |
|
|
(305mm) |
water that is beyond these |
|||||
|
|
|
|||||||
10.44" |
OPERATING |
24.00" |
|
specified guidelines should |
|||||
(265mm) |
|
||||||||
CLEARANCE |
|
be treated to achieve these |
|||||||
20.63" |
(508mm) |
|
|||||||
(524mm) |
SECONDARY |
|
|
acceptable |
limits. |
Total |
|||
20.88" |
|
|
Dissolved Solids less than |
||||||
(530mm) |
CLEARANCE |
|
|
||||||
|
|
60 ppm, Alkalinity less than |
|||||||
|
|
|
|
||||||
|
|
|
|
20 ppm, Silica less than 13 |
|||||
|
|
13.25" |
ppm, pH factor greater |
||||||
|
|
(337mm) |
than 7.5, |
Chlorine |
less |
||||
|
|
|
|
||||||
|
2.06" |
|
|
than 30 ppm. |
|
|
|
||
|
(52mm) |
|
10.00" |
|
|
|
|
|
|
|
|
|
(254mm) |
|
|
|
|
|
|
|
|
|
|
Each Compartment has |
|
||||
4.75" |
|
|
|
Capacity for: |
|
|
|
|
|
(121mm) |
|
|
|
• Three |
21⁄2˝ x 12˝ x 20˝ |
|
|||
20.36" |
|
|
|
Steam Table Pans |
|
|
|||
(517mm) |
|
|
|
• Six 1˝ x 12˝ x 20˝ |
|
|
|||
13.88" |
|
|
|
|
|
||||
(353mm) |
|
|
|
Steam Table Pans |
|
|
|||
|
|
|
|
• Two 4˝ x 12˝ x 20˝ |
|
|
|||
|
|
|
|
Steam Table Pans |
|
|
|||
|
59.21" |
|
|
|
|
|
|
|
|
|
(1504mm) |
|
|
|
|
|
|
|
|
|
|
20.50" |
7.34" |
|
|
|
|
|
|
|
|
(521mm) |
(186mm) |
|
|
|
|
|
|
|
|
|
|
5.00" |
|
|
|
|
|
|
|
|
|
(127mm) |
|
|
|
|
|
17.25" TYP |
|
|
|
6.60" |
|
|
|
|
|
(438mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
(168mm) |
|
|
|
|
|
6.13" |
|
|
|
|
|
|
|
|
|
(156mm) |
|
|
|
|
|
|
|
|
|
21.50" |
|
30.25" |
|
|
|
|
|
|
|
(546mm) |
|
(768) |
|
|
|
|
|
|
|
24.00" |
|
33.13" |
|
|
|
|
|
|
|
(610mm) |
|
(842) |
|
|
|
|
|
|
|
|
GAS |
|
ELECTRIC |
C COLD WATER |
CLEARANCE |
D DRAINAGE |
11⁄4˝ IPS line size, 3⁄4˝ connection |
120V-1Phase, 60 Hz. |
35 psi minimum |
RightRIGHT- 3”, Left= 12- 3”,.00˝ |
11⁄2˝ dia. |
||
|
|
|
|
|
Rear - 3” |
|
NATURAL |
PROPANE |
BTU |
2 Blowers & Controls |
60 psi maximum |
LEFT = 3.00˝ |
Do not connect other |
|
|
|
|
|
(12” on control side if |
|
Piping 3⁄4˝ N.P.T. |
Piping 3⁄4˝ N.P.T. |
50,000 each |
150 watts each |
C2 3⁄8˝ dia. NPT for Generator |
adjoiningREARwall= or3.00˝ |
units to this drain |
Supply pressure |
Supply pressure |
Generator, |
|
C1 3⁄8˝ dia. NPT for Condenser |
equipment is over 30” |
|
|
Allow 6˝ space min. |
|
||||
|
|
|
|
|
high for service access) |
|
4.50˝ W.C. Min. |
11.00˝ W.C. Min. |
100,000 total |
|
|
from rear and sides |
Drain must be vented |
14.00˝ W.C. Max. |
14.00˝ W.C. Max. |
|
|
|
Contact factory |
|
|
|
|
When located near |
|
||
|
|
|
|
|
for variances to |
Do not use PVC pipe |
|
|
|
|
|
combustible walls |
|
|
|
|
|
|
clearances. |
|
Manufacturer must be notified if unit will be used above 2,000 feet
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA (AGA, CGA).
(NOT TO SCALE) SECT. IV PAGE 12 0104
Litho in U.S.A.
SteamCraft ® Gemini TM 10
TWO COMPARTMENT FLOOR MODEL DESIGN PRESSURELESS CONVECTION STEAMER
TWIN, INDEPENDENT GAS-FIRED GENERATORS
Cleveland Standard Features
■Cooking Capacity for up to ten 12˝ x 20˝ x 2 1/2˝ deep Cafeteria Pans, five each compartment.
■Totally independent cooking compartments, each has its' own generator, gas valve and water level controls - no shared components
■Exclusive High Efficiency Gas Power Burner (forced air) Generator: Produces more steam for faster cooking while lowering operating costs (72M BTU's per compartment)
■Easy Access Cleaning Port: Each generator has a deliming port located on the outside, top of the unit
■Generator Cleaning Light for each compartment warns the operator to delime generator
■Instant Steam Standby Mode: Holds generator at a steaming temperature, allows unit to start cooking instantly
■Each compartment has one, 60-Minute Electro-Mechanical Timer with load compensating feature. Manual Bypass Switch for constant steaming.
■Durable 14 Gauge, 304 Stainless Steel construction for compartment door, cooking cavity and steam generator
■Exclusive Two-Piece Compartment door: Slammable, self-adjusting door provides and airtight seal, reversable door gasket for extended life
■Exclusive Gemini Drain/Power Control System: Simple, reliable 1/2" ball valve style drain automatically turns power ON/OFF
■Exclusive Brass Steam Jets distribute even-high velocity steam throughout cooking compartment for faster cooking times
■Easy, Front -Access Generator Controls comes with a pullout drawer for simple servicing of unit
■6˝ Stainless Steel Adjustable Legs with Flanged Feet
■Approvals: CSA (AGA, CSA) and U.L/NSF#4
■Compartment Steam Shut-Off Switch (SCS)
Options & Accessories
Electronic Timer with Compensating Feature (ETC)
On/Off Steam Switch Controls, no timer (MC)
Cleveland Range Inc.
MODEL: 24-CGA-10.2
ITEM NUMBER __________________________________________
JOB NAME / NUMBER __________________________________
Short Form Specifications
Shall be Two Compartments, Cleveland Convection Steamer series SteamCraft GeminiTM 10, Model 24-CGA-10.2, Twin Gas Atmospheric Steam Generator, 72M BTU"s input per compartment. Independent steam generator, gas valve and water level control system.
Automatic Generator Blowdown. Steam Generator with Automatic Water Fill on start up. Exclusive remote probe-type water level controls. Exclusive Brass “Steam Jet” distribution system. Two-piece freefloating compartment door. Type 430 Stainless Steel exterior and cooking compartments. Pullout service drawer for controls and Gemini Drain/Power Control System. Exclusive Cold Water Condenser design. Choice of Compartment Controls. Manual
Propane Gas (PG)
Dissolve ® Descale Solution, 6 one gallon container w/quart markings (106174)
Water Filters
SECT. IV PAGE 13 0402
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110
Ph: 1-216-481-4900 Fx: 1-216-481-3782
Visit our Web Site at www.clevelandrange.com
Each Compartment has capacity for:
• Five, 12˝ x 20˝ x1⁄˝2 deep Cafeteria Pans.
WATER QUALITY
REQUIREMENTS
The quality of water varies greatly from region to region. Steam equipment generators must be drained daily and chemically descaled periodically to ensure proper operation. To minimize service problems caused by the accumulation of minerals and chemicals in water review the following quality guidelines with a local water treatment specialist. Inlet water that is beyond these specified guidelines should be treated to achieve these acceptable limits. Total Dissolved Solids less than 60 ppm, Alkalinity less than 20 ppm, Silica less than 13 ppm, pH factor greater than 7.5, Chlorine less than 30 ppm.
A B DE
|
|
|
|
|
|
ELECTRIC |
C COLD WATER |
|
CLEARANCE |
D DRAINAGE |
|
|
|
1 ⁄4˝ IPS line |
(13mm) connection |
120V-1Phase, 60 Hz. |
35 psi minimum |
|
|
|
1 ⁄2˝ dia. |
|
|||
|
|
RIGHT = 3˝ operating, |
|
|||||||||
|
1 |
|
|
|
|
|
|
|
Right - 3”, Left - 3”, |
|
1 |
|
|
|
|
|
|
|
|
|
|
Rear -3” |
|
|
|
|
NATURAL |
|
PROPANE |
BTU |
2 Blowers & Controls |
60 psi maximum |
|
12˝ if adjoining wall or |
|
Do not connect other |
|
|
|
|
|
|
|
|
|
|
|
(12” on control side if adjoining |
|
|
|
|
Piping 3⁄4˝ N.P.T. |
|
Piping3⁄4˝ N.P.T. |
|
|
|
|
|
|
|||
|
|
72,000 each |
150 watts each |
|
|
wall or equipmentLEFT =is over3˝ 30” |
|
units to this drain |
|
|||
|
Supply pressure |
|
Supply pressure |
Generator, |
|
One (E) 1/4" dia. |
|
high for service access) |
|
|
|
|
|
|
|
|
REAR = 3˝ |
|
|
|
|||||
|
4.50˝ W.C. Min. |
|
W.C. Min. |
144,000 total |
|
NPT for Generator |
|
Allow 6˝ space min. |
|
Drain must be vented |
|
|
|
|
|
|
|
|
|
|
|
Contact factory |
|
|
|
|
14.00˝ W.C. Max. |
|
W.C. Max. |
|
|
|
|
|
for variances to |
|
|
|
|
|
|
|
|
|
|
from rear and sides |
|
|
|
||
|
|
|
|
|
|
|
One (D) 1/4" dia |
|
clearances. |
|
Do not use PVC pipe |
|
|
|
|
|
|
|
|
|
when located near |
|
|
||
|
Manufacturer must be notified if unit will |
|
|
|
NPT for Condenser |
|
combustible walls |
|
|
|
||
|
be used above 2,000 feet |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are UL/NSF#4 and CSA (AGA, CGA).
(NOT TO SCALE) SECT. IV PAGE 14 0402
Litho in U.S.A.