“CAUTION: IMPROPER INSTALL ATION MAY CAUSE SERIOUS DAMAGE, FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY”
“THIS MANUAL IS ONLY FOR PROFESSIONAL INSTALLERS OR QUALIFIED PERSONS”
1 Legend of symbols
This symbol indicates sections to be read with particular care.
This symbol indicates sections concerning safety.
This symbol indicates notes to communicate to users.
ENGLISH
2 Intended use and application
2.1 Intended use
The ZLJ24 control panel is engineered to command 24V D.C. automation for swing gates of the Axo-Frog-Ferni-Fast series.
The use of this product for purposes other than as described above and installation executed in a manner other than as
instructed in this technical manual are prohibited.
2.2 Application
Make sure you respect the distances and cable diameters as shown in “cable types and minimal thicknesses” table.
The overall power of the motors must not exceed 500 W.
3 Reference Standards
For its quality processes management Came Cancelli Automatici is ISO 9001:2000 certified, and for its environmental management it is
ISO 14001 certified. Came designs and manufactures entirely in Italy.
This product complies with the following standards: see Declaration of Compliance.
4 Description
This product is engineered and manufactured by CAME cancelli automatici s.p.a. and complies with current safety regulations.
Guaranteed 24 months if not tampered with.
The control panel works on 230V a.c. of power, 50/60Hz frequency.
The command devices and accessories are 24V rated. Warning! Accessories must not exceed an overall total of 50W.
All connections are protected by quick fuses, see table.
The input and output contact functions, the timing settings and users’ management, are set and viewed on the display, which is run by
software.
Set up to connect the LB180 board to power the batteries, which, in case of a power failure, intervene automatically. When the power
comes back on, the board automatically recharges the batteries.
2 - Card fuse
3 - Accessories fuse
4 - Electrolock fuse
5 - Display
6 - Display lighting adjustment trimmer
7 - Memory roll card connector
8 - AF card connector
9 - R700 card connector
10 - Open contact error - warning LED
11 - Programming buttons
12 - Terminal board for connecting
13 - Terminal board for 230V a.c. power grid
14 - Line fuse
15 - 230V-power signalling LED
1
6 - Motor 1 fuses 2
17 - Motor 1 fuses 2
3
2
16
17
1
26V
17V
0V
230V
0
1
26V
17V
0V
ENGLISH
230V
0
4
5
11
6
Warning! Before acting on the machinery,
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
cut off the main power supply and disconnect
any emergency batteries.
Installation must be carried out by expert qualified personnel and in full observance of regulations in force.
5.1 Preliminary checks
Before installing do the following:
• Check that the panel’s anchoring point is protected from possible blows, and that the anchoring surface is solid. Also check that the
anchoring is done using the appropriate bolts, screws etc.;
• Make sure you have a suitable omnipolar cut-off device with contacts more than 3 mm apart, and independent (sectioned off) power
supply;
ENGLISH
• Make sure that any connections inside the case (that provide continuance to the protective circuit) are fitted with extra insulation
as compared to the other conductive parts inside;
• Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical
damage.
5.2 Tools and materials
Make sure you have all the tools and materials you will need for the installation at hand to work in total safety and compliance with the
current standards and regulations. The following figure illustrates the minimum equipment needed by the installer.
Here are some examples.
5.3 Fixing and mounting the box
1) Fix the base of the panel in a protected area; we suggest
using round top Phillips recessed head screws of max.
6mm in diameter.
3) Assemble the pressure hinges.
2) Perforate the pre-punched holes and insert the cable
glands with the corrugated tubing for the electrical
cables to travel through.
N.B.: diameter of the pre-punched holes: 20 mm.
!!
4) Insert the pressure hinges into the box (on the left or right as you
wish) and set them using the provided screws and washers.
N.B.: If the cable length differs from that specified in the table, then you must determine the proper cable diameter based on the actual
power draw from the connected devices and according to the CEI EN 60204-1 standards.
For connections that require several, sequential loads, the sizes given on the table must be re-evaluated based on actual power draw
and distances.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
When connecting products that are not specified in this manual, please follow the documentation provided with said products.
Signal Flasher (socket rating: 24V 25W max.) Flashes during opening
and closing phases.
Cycle lamp: (contact rating: 24V – 25W max.)
It lights up the driving area and stays on from
ENGLISH
the moment the gate begins to open until it is
fully closed (including the automatic closing
time). If automatic closing is not activated, the
lamp stays on only during movement.
Command devices
TSP00 - Transponder sensor
LT001 - Magnetic card reader
ACCESS CONTROL
Open gate indicator-light
(socket rating: 24V - 3W max.).
Turns on when the gate is ajar or open.
It turns off when the gate is closed.
N.B. : insert the (R700) coding board to have
the (TSP00) sensor or (LT001) card reader
recognised.
CAME
Stop button (N.C. contact) - Button to stop gate while
excluding the automatic closing cycle. For movement to
resume you must press the command button or transmitter
button.
N.B.: if contact is unused, select Disabled on the
“FUNCTIONS” menu.
Key selector and/or commands button (N.O. contact) - Commands for opening and closing the
gate – pressing the button or turning the keyswitch, inverts the gate’s movement or stops it
depending on how it is set on the 2-7 command in
the “FUNCTIONS” menu.
M1 - 24V D.C. gearmotor featuring delayed action on openingM2 - 24V D.C. gearmotor featuring delayed action on closing
F4024
FERNI
M1 N1 E1
M2 N2 E2
FROG-A24
Gearmotor, encoder
M1 - 24V D.C. gearmotor featuring delayed action on opening
AXO
M1 N1 E1 + E -
FROG A24E
White
Brown
Green
ENCODER A
FROG-A24
F4024
2 FA1 FC1 FA2 FC2
M2 - 24V D.C. gearmotor featuring delayed action on closing
AXO
ENCODER B
M2 N2 E2 + E -
Green
Brown
White
FROG A24E
FERNI
ENGLISH
Safety devices
Confi gure either (N.C.) contacts CX, CY or CZ, input
for safety devices such as photocells, that comply with
EN 12978 standards. See CX, CY or CZ input functions
in:
- C1 «re-open during closing phase», When the
gate leaf is closing, opening the contact triggers the
inversion of the direction of movement until the gate
leaf is fully open.
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
- C2 «re-close during opening phase», When gate
is opening, if the contact is opened it triggers an
inversion of the direction until gate is fully closed;
- C3 «partial stop»,Halts moving gate leaves and
causes them to automatically close (if this functions
has been selected);
- C4 «stand-by Obstacle»,Halts the moving gate
leaves causing them to start moving again once
obstacle is removed.
input for EN 12978 compliant safety devices such
as sensitive edges. See CX input functions in:
- C7 «Open while closing»,
During gate closing,
opening the contact causes inversion of movement
until gate is fully open;
- C8 «close while opening», During gate opening,
opening the contact causes inversion of movement
until gate is fully close.
ENGLISH
- Deactivated, if contact is unused.
DF
DF with DFI connections
monitor card
6.3 Electrical connection for the photocells functions test
(DOC)
./
#
.#
(DIR)
48
&53)"),%M!
#
.#
48
48
At each opening and closing command, the control board assesses the effi ciency status of the control devices (photocells). Any
anomaly found is signalled with the fl ashing of the LED on the control panel. Consequently it cancels any commands coming from the
remote control or the button.
Electrical connection to enable the photocell safety test:
- the transmitter and the receiver, must be connected as per the diagram;
- from the functions menu, select “safety tests” and select either CX - CY - CZ input/s to activate the test
To enter the menu, keep the
ENTER key pressed for at least one
second.
Lingua
Italiano
Þß
the <...> symbols on the display are for:
-pointing out the currently, selected item
{
The ENTER key is for:
- entering the menu;
{
- confirming and memorising set values.
{
Þß
LANGUAGE
English
ENGLISH
To select a menu item,
mode using the greater
than-lesser than keys...
also use the greater
than-lesser than keys
for the “sub-menus”...
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.