Burkert 8176, 8177 Safety Instructions

Safety instructions
LEVEL TRANSMITTER LT817*.C***H***
PTB 07 ATEX 2003 X
0102
32829
Safety instructions
Con
tents
EG-Konfo
rmitätserklärung 4
EC declaration of conformity 4
Déclaration CE de conformité 4
1 Area of applicability 5
2 General 5
2.1 Category 1/2G instruments 5
2.2 Category 2G instruments 5
3 Technical data 6
3.1 Electrical versions and data 6
4 Application conditions 7
4.1 Permissible ambient temperatures 7
4.2 Permissible operating pressure 8
5 Protection against static electricity 8
6 Use of an overvoltage arrester 8
7 Grounding 8
8 Material resistance 9
9 Installation 9
Please note:
These safety instructions are part of the operating instructions:
l 32058 - LEVEL
TRANSMITTER 8176
l 32059 - LEVEL
TRANSMITTER 8177
l 33453 - EC type
approval certicate PTB 07 ATEX 2003 X
2 LEVEL TRANSMITTER LT817*.C***H***
32829-EN-070615
Safety instructions
DE
Sicherheitshinweise für den Einsatz in explosionsgefährdeten Bereichen, verfügbar in den Sprachen deutsch, englisch, französisch und spanisch.
EN
Safety instructions for the use in hazardous areas are available in German, English, French and Spanish language.
FR
Consignes de sécurité pour l'utilisation en atmosphère explosible, disponibles dans les langues allemande, anglaise, française et espagnole.
ES
Instrucciones de seguridad para el empleo en áreas con riesgo de explosión, disponible en los siguientes idiomas alemán, ingles, francés y español.
CZ
Pokud nastanou potíže při čtení bezpečnostních upozornění v otištěných jazycích, poskytneme. Vám na základě žádosti k dispozici kopii v jazyce Vaší země.
DA
Hvis De har svært ved at forstå sikkerhedsforskrifterne på de trykte sprog, kan. De få en kopi på Deres sprog, hvis De ønsker det.
EL
Εάν δυσκολεύεστε να διαβάσετε τις υποδείξεις ασφαλείας στις γλώσσες που ήδη έχουν τυπωθεί, τότε σε περίπτωση ζήτησης μπορούμε να θέσουμε στη διάθεσή σας ένα αντίγραφο αυτών στη γλώσσα της χώρας σας.
ET
Kui teil on raskusi trükitud keeltes ohutusnõuete lugemisega, siis saadame me teie järelepärimise peale nende koopia teie riigi keeles.
FI
Laitteen mukana on erikielisiä turvallisuusohjeita. Voit tilata meiltä äidinkieliset turvallisuusohjeet, jos et selviä mukana olevilla kielillä.
HU
Ha a biztonági előírásokat a kinyomtatott nyelveken nem tudja megfelelően elolvasni, akkor lépjen velünk kapcsolatba: azonnal a rendelkezésére bocsátunk egy példányt az Ön országában használt nyelven.
IT
Se le Normative di sicurezza sono stampate in una lingua di dicile comprensione, potete richiederne una copia nella lingua del vostro paese.
LT
Jei Jums sunku suprasti saugos nuorodų tekstą pateiktomis kalbomis, kreipkitės į mus ir mes Jums duosime kopiją Jūsų šalies kalba.
LV
Ja Jums ir problēmas drošības noteikumus lasīt nodrukātajāsvalodās, tad mēs Jums sniegsim pēc pieprasījuma kopiju Jūsu valsts valodā.
MT
F’kaz li jkollok xi dikulta` biex tifhem listruzzjonijiet tasigurta`kif ipprovduti, infurmana u ahna nibghatulek kopja billingwa tieghek.
NL
Als u moeilijkheden mocht hebben met het lezen van de veiligheidsinstructies in de afgedrukte talen, sturen wij u op aanvraag graag een kopie toe in uw eigen taal.
PL
W przypadku trudności odczytania przepisów bezpieczeństwa pracy w wydrukowanych językach, chętnie udostępnimy Państwu kopię w języku obowiązującym w danym kraju.
PT
Caso tenha diculdade de ler as instruções de segurança no idioma, no elas foram impressas, poderá solicitar junto a nós uma cópia em seu idioma.
SK
Pokiaľ nastanú problémy pri čítaní bezpečnostných pokynov vo vydaných jazykoch, poskytneme Vám na základe žiadosti k dispozícii kópiu v jazyku Vašej krajiny.
SL
Kadar se pojavijo težave pri branju varnostnih navodil v izdanih jezikih, vam bomo na osnovi zahtevka dali na razpolago kopijo v jeziku vaše države.
SV
Om du har problem att läsa säkerhetsanvisningarna på de här tryckta språken, ställer vi gärna på begäran en kopia på ditt språk till förfogande.
LEVEL TRANSMITTER LT817*.C***H*** 3
32829-EN-070615
EG-Konformitätserklärung
EC declaration of conformity
Déclaration CE de conformité
Bürkert Werke GmbH & Co.KG
Christian-Bürkert-Straße 13 - 17
74653 Ingelngen
Deutschland
erklärt in alleiniger Verantwortung, dass das Produkt
declare under our sole responsibility that our product
déclare sous sa seule responsabilité que le produit
LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H***
auf das sich diese Erklärung bezieht, mit den folgenden Normen übereinstimmt
to which this declaration relates is in conformity with the following standards
auquel se réfère cette déclaration est conforme aux normes
EN 50014: 1997 + A1 + A2
EN 50020: 1999 EN 50284: 1999
EN 61010-1: 2001
EN 61326: 1997/A1: 1998 Emission (Klasse A/class A/classe A)
EN 61326: 1997/A1: 1998 Immission/Susceptibility
gemäß den Bestimmungen der Richtlinien
following the provision of Directives
conformément aux dispositions des Directives
94/9/EG
2006/95/EG
89/336/EWG
EG Baumusterprüfbescheinigung Nummer PTB 07 ATEX 2003 X EC-Type Examiniation Certicate Number Numéro du certicat d'examen CE de type
Benannte Stelle/Kennnummer PTB/0102 Notied Body/Itdentication number Organisme notié/Numéro d'identication
Ingelngen, 26.03.07
i.A. Sonja Drolshagen Certications Engineer
4 LEVEL TRANSMITTER LT817*.C***H***
32829-EN-070615
1 Area of applicability
These
safety instructions apply to the ultrasonic sensors LEVEL TRANSMITTER 8176 and
LEVEL TRANSMITTER 8177 of type series LEVEL TRANSMITTER LT8176.C***H***, LT8177. C***H*** according to the EC type approval certicate PTB 07 ATEX 2003 X (certication
number on the type label).
2 Gene
ral
The
ultrasonic level measuring instrument LEVEL TRANSMITTER LT8176.C***H***, LT8177. C***H*** is used to detect the distance between product surface and transducer by means of ultrasonic waves in the kHz range. The electronics uses the running time of the signals reected by the product surface to calculate the distance to the product surface. The ultrasonic sensors LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** consist of an electronics housing, a process connection element and a sensor, the transducer. As an option, an indication and adjustment module with the designation AB/MODUL-BÜRKERT can be integrated.
The ultrasonic sensors LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** are suitable for applications in hazardous atmospheres of all combustible materials of explosion group IIA, IIB and IIC, for applications requiring instruments of category 1/2G or 2G. The products to be measured can also be combustible liquids, gases, mist or vapour.
If the ultrasonic sensors LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** are installed and operated in hazardous areas, the general Ex mounting instructions and these safety instructions must be observed.
The operating instructions as well as the appropriate Ex mounting instructions, i.e. standards for electrical equipment, must always be observed.
The installation of explosion protected systems must always be carried out by qualied personnel.
2.1 Category 1/2G instruments
The electronics housing of the ultrasonic sensors LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** is installed in hazardous areas requiring instruments of category 2G. The
process connection element is installed in the separating wall, which separates areas requiring instruments of category 2G or 1G. The sensor with the mechanical xing element is installed in hazardous areas requiring instruments of category 1G.
2.2 Category 2G instruments
The ultrasonic sensors LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** are installed in hazardous areas requiring instruments of category 2G.
LEVEL TRANSMITTER LT817*.C***H*** 5
32829-EN-070615
3 Technical data
3.1 Elect
rical versions and data
Ignition protection intrinsic safety Ex "i"
The LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** are provided with intrinsi­cally afe circuits. These intrinsically safe circuits are connected on terminals which are located in an "Ex i" connection compartment.
Power supply and signal circuit: (termi­nal no. 1[+], no.. 2[-] in the Ex "i" connection compartment)
In ame proong intrinsic safety EEx ia IIC/IIB Only for connection to a certied intrinsically
safe circuit.
Maximum values: U
i
= 30 V
I
i
= 131 mA
P
i
= 983 mW Eective internal inductance Li is negligible; eective internal capacity Ci is negligible
Indicating and adjustment circuit: (ter-
minal 5, 6, 7, 8 in electronics compart­ment or plug connection with double chamber housing version)
In ame proong intrinsic safety EEx ia IIC For connection to the intrinsically safe power
supply and signal circuit of a passive/external indication unit (PTB 02 ATEX 2136 X). The rules for the interconnection of intrinsically safe circuits between the ultrasonic sensors
LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** and the external indication
unit are maintained, if the total inductance and total capacity of the connection cable between microwave sensors LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** and the indication unit L
cable
= 100 µH and C
cable
=
2,8 µF is not exceeded. The indication and adjustment module (AB-MODUL-BÜRKERT) integrated in LEVEL TRANSMITTER LT8176. C***H***, LT8177.C***H*** and connected in­terface converter are taken into account.
Communication circuit: (I²C-BUS socket in the electronics compartment, addi­tionally in the connection compartment with double chamber housing version)
In ignition protection type intrinsic safety EEx ia IIC For connection to the intrinsically safe signal
circuit of an interface converter
(PTB 07 ATEX 2013 X).
Indicating and adjustment module cir-
cuit: (spring contacts in the electronics compartment)
In ignition protection type intrinsic safety EEx ia IIC Only for connection to the indicating and adjustment module (AB-MODUL-BÜRKERT)
6 LEVEL TRANSMITTER LT817*.C***H***
32829-EN-070615
The intrinsically safe circuits are electrically separated from parts which can be grounded.
For applications requiring instruments of category 2G, the intrinsically safe power supply and
signal circuit can correspond to protection class ia or ib. For connection to a circuit with protection class ib, the ame proong identication is EEx ib IIC T6.
For applications requiring instruments of category 1/2G, the intrinsically safe power supply and signal circuit must be in conformity with protection class ia.
For applications requiring instruments of category 1/2G the LEVEL TRANSMITTER LT8176. C***H***, LT8177.C***H*** is preferably connected to appropriate instruments with electrically
separated intrinsically safe circuits.
4 App
lication conditions
4.1 Perm
issible ambient temperatures
4.1.1 For use as category 1/2G instrument
Temperature class Permissible ambient temperature
on the electronics
Permissible ambient temperature on the transducer
T6 -40 … +57 °C -20 +58 °C T5 -40 … +72 °C -20 +60 °C T4, T3, T2, T1 -40 … +85 °C -20 +60 °C
For the specied permissible ambient temperatures on the sensor and electronics, the 80% consideration of EN 1127-1 sect. 6.4.2 is taken into account.
If the LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** are operated at higher
temperatures than those specied in the above table, please make sure by means of appropriate measures that there is no danger of ignition from these hot surfaces, under consideration of the 6 K self-warming on the transducer. The permissible temperature on the electronics/housing should not exceed the values specied in the above table.
The application conditions during operation without explosive mixtures are mentioned in the manufacturer instructions.
4.1.2 For use as category 2G instrument
Temperature class Permissible ambient temperature
on the electronics
Permissible ambient temperature on the transducer
T6 -40 … +57 °C -20 +74 °C T5 -40 … +72 °C -20 +89 °C T4, T3, T2, T1 -40 … +85 °C -20 +90 °C
LEVEL TRANSMITTER LT817*.C***H*** 7
32829-EN-070615
If the LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** are operated with higher
temperatures as stated in the above mentioned table, please make sure by appropriate measures, that the danger of ignition caused by these hot surfaces can be excluded, under consideration of the self-heating of 6 K on the transducer. The max. permissible temperature on the electronics/housing should not exceed the values stated in the above mentioned table.
The application conditions during operation without explosive mixtures are mentioned in the manufacturer instructions.
4.2 Permissible operating pressure
For applications requiring instruments of category 1/2G, the process pressure of the media must be between 0.8 … 1.1 bar.
5 Prot
ection against static electricity
The ultrasonic sensors LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** have surfaces that can get electrostatically charged. A caution label on the housing refers to the safety measures that must be applied when the danger of electrostatic charges exists during operation and maintenance work.
Caution: Plastic parts! Danger of static charge!
l Avoid
friction
l No
dry cleaning
l Do
not mount in pneumatic lling stream
6 Use
of an overvoltage arrester
On
request the ultrasonic sensors LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H***
can be connected to an overvoltage arrester.
If the ultrasonic sensors LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** are used as category 1/2G instruments, lightning protection measures according to EN 60079-14 sect.
12.3 are not required.
7 Gro
unding
The LEVEL
TRANSMITTER LT8176.C***H***, LT8177.C***H*** must be electrostatically
grounded (transfer resistance ≤1MOhm), e.g. via the ground terminal,
8 LEVEL TRANSMITTER LT817*.C***H***
32829-EN-070615
8 Material resistance
For
applications requiring instruments of category 1/2G the LEVEL TRANSMITTER LT8176. C***H***, LT8177.C***H*** should only be used in media against which the wetted materials are suciently resistant.
9 Ins
tallation
To
exclude the danger of mechanical damage the LEVEL TRANSMITTER LT8176.C***H***, LT8177.C***H*** must be installed in such a way, that the transducer is protected against environmental stress.
LEVEL TRANSMITTER LT817*.C***H*** 9
32829-EN-070615
10 LEVEL TRANSMITTER LT817*.C***H***
32829-EN-070615
LEVEL TRANSMITTER LT817*.C***H*** 11
32829-EN-070615
Loading...
+ 25 hidden pages