Brocade, Brocade Assurance, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, MLX, NetIron, SAN Health, ServerIron, TurboIron, VCS, and VDX
are registered trademarks, and AnyIO, Brocade One, CloudPlex, Effortless Networking, ICX, NET Health, OpenScript, and The Effortless Network
are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service
names mentioned may be trademarks of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment,
equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time,
without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available.
Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may
require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss,
cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
The product described by this document may contain “open source” software covered by the GNU General Public License or other open source
license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open
source software, and obtain a copy of the programming source code, please visit
http://www.brocade.com/support/oscd.
Brocade Communications Systems, Incorporated
Corporate and Latin American Headquarters
Brocade Communications Systems, Inc.
130 Holger Way
San Jose, CA 95134
Tel: 1-408-333-8000
Fax: 1-408-333-8101
E-mail: info@brocade.com
European Headquarters
Brocade Communications Switzerland Sàrl
Centre Swissair
Tour B - 4ème étage
29, Route de l'Aéroport
Case Postale 105
CH-1215 Genève 15
Switzerland
Tel: +41 22 799 5640
Fax: +41 22 799 5641
E-mail: emea-info@brocade.com
Asia-Pacific Headquarters
Brocade Communications Systems China HK, Ltd.
No. 1 Guanghua Road
Chao Yang District
Units 2718 and 2818
Beijing 100020, China
Tel: +8610 6588 8888
Fax: +8610 6588 9999
E-mail: china-info@brocade.com
Asia-Pacific Headquarters
Brocade Communications Systems Co., Ltd. (Shenzhen WFOE)
Citic Plaza
No. 233 Tian He Road North
Unit 1308 – 13th Floor
Guangzhou, China
Tel: +8620 3891 2000
Fax: +8620 3891 2111
E-mail: china-info@brocade.com
Brocade VDX 8770-8 QuickStart Guide3 of 34
Publication Number: 53-1002555-01
Introduction
DANGER
You can set up and install the Brocade VDX 8770-8 in the following ways:
• As a standalone unit on a flat surface
• In a four-post rack
• In a two-post telecommunications (Telco) rack
This manual describes how to set up the Brocade VDX 8770-8 as a standalone unit. For rack mount installation
instructions, refer to the manual that comes with the separately ordered rack kit.
Tab le 1 describes the main installation and setup tasks, the estimated time required for each, and the items
required to complete the task based on a fully populated Brocade VDX 8770-8 (384 10 GbE ports). Configurations
with fewer ports require less time. These time estimates assume a prepared installation site and appropriate power
and network connectivity.
The procedures in this manual are for qualified service personnel.
TABLE 1Installation tasks, time, and items required
Installation taskTime estimateItems required
Site preparation and unpacking Brocade
VDX 8770-8
Installing the rack mount kit30 minutes
Mounting and securing Brocade VDX
8770-8 in the rack
Inserting modules and power supplies5-10 minutes per
Installing power cables and powering on
the Brocade VDX 8770-8
Establishing a serial connection, logging on
to the Brocade VDX 8770-8, and
configuring the IP addresses
Installing an Ethernet cable, opening a
Telnet session, and configuring the
Brocade VDX 8770-8 date and time and
additional system parameters. Verify and
back up configuration.
30 minutes#2 Phillips screwdriver.
30 minutes
unit
20 minutesPower cables (provided in the Brocade VDX
20 minutesSerial cable (also called the console cable -
20 minutesEthernet cabling (optional) for Telnet access.
Pallet jack.
Hydraulic lift or assisted lift, able to raise to a
minimum of 140 cm (55 in.), with a minimum
capacity of 113 kg (250 lb). A fully loaded
version of the Brocade VDX 8770-8 weighs
165.56 kg (365 lbs).
Refer to the proper rack mount kit instructions
for your specific rack..
Management modules, switch fabric modules,
line cards, power supplies (AC or DC).
8770-8 accessory kit).
provided in the accessory kit).
Workstation computer with a serial (console)
port or terminal server port and a terminal
emulator application (such as HyperTerminal).
Ethernet IP addresses for the Brocade VDX
8770-8 switch and for management modules:
total two or three addresses, depending on the
number of management modules installed.
Refer to the Brocade Network OS Administrator’s Guide.
4 of 34Brocade VDX 8770-8 QuickStart Guide
Publication Number: 53-1002555-01
CAUTION
CAUTION
NOTE
DANGER
TABLE 1Installation tasks, time, and items required (Continued)
Installation taskTime estimateItems required
Installing transceivers as needed30-60 minutes Copper and optical transceivers and
direct-attach cables as needed.
Attaching cables, cable ties, and cable
guides
The Brocade VDX 8770-8 with DC power sources are intended for installation in restricted access areas
only. A restricted access area is a location where access can be gained only by service personnel through
the use of a special tool, lock and key, or other means of security, and is controlled by the authority
responsible for the location.
The Brocade VDX 8770-8 with AC power sources are intended for installation in restricted access areas
only. A restricted access area is a location where access can be gained only by service personnel through
the use of a special tool, lock and key, or other means of security.
2-3 hoursCables, cable ties, and cable comb.
Safety notices
When using this product, observe the danger, caution, and attention notices in this manual. The notices are
accompanied by symbols that represent the severity of the safety condition.
Translated safety notices are in the Brocade Product Safety Notices publication, which is on the CD-ROM that
accompanies this product.
The danger and caution notices are listed in numerical order based on their IDs, which are displayed in parentheses,
for example (D004), at the end of each notice. Use this ID to locate the translations of these danger and caution
notices in the Brocade Product Safety Notices.
Danger notices
A danger notice calls attention to a situation that is potentially lethal or extremely hazardous to people. A
lightning bolt symbol accompanies a danger notice to represent a dangerous electrical condition. Read and
comply with the following danger notice before installing or servicing this device.
Use the supplied power cords. Ensure the facility power receptacle is the correct type, supplies the
required voltage, and is properly grounded. (D004)
Brocade VDX 8770-8 QuickStart Guide5 of 34
Publication Number: 53-1002555-01
Caution notices
CAUTION
NOTE
A caution notice calls attention to a situation that is potentially hazardous to people because of some existing
condition. Read and comply with the following caution notice before installing or servicing this device.
Use safe lifting practices when moving the product. (C015)
ESD precautions
The Brocade VDX 8770-8 contains ESD-sensitive FRUs. When working with any Brocade VDX 8770-8 FRU, use
correct electrostatic discharge (ESD) procedures.
• Wear a wrist grounding strap connected to chassis ground (if the Brocade VDX 8770-8 is plugged in) or a
bench ground. Refer to Figure 1 on page 7 for the location of the ESD jack.
• Store ESD-sensitive components in antistatic packaging.
Brocade VDX 8770-8, port side
Airflow in the Brocade VDX 8770-8 is from the port side and left side (viewed from the port side) to the rear (fan side)
of the chassis.
Figure 1 displays a sample configuration of the port side of the Brocade VDX 8770-8.
6 of 34Brocade VDX 8770-8 QuickStart Guide
Publication Number: 53-1002555-01
1Line cards L1 through L4 (left to right)6Intake Vent
2Cable management comb7Management modules MM1 and MM2 (left to
right)
3Switch fabric modules S1 through S6 (odd numbers
above, even numbers below, left to right)
4Line cards L5 through L8 (left to right)9ESD jack
5Mounting flanges
8Power supplies 1 through 8 (1 through 4 above,
left to right, 5 through 8 below, left to right))
FIGURE 1Port side of the Brocade VDX 8770-8 (sample configuration)
Brocade VDX 8770-8 QuickStart Guide7 of 34
Publication Number: 53-1002555-01
Brocade VDX 8770-8, nonport side
Figure 2 displays a sample configuration of the nonport side view of the Brocade VDX 8770-8.
1Fan assemblies 1 and 2 (left to right)3Power supply exhaust vent
2Fan assemblies 3 and 4 (left to right)4Ground lug
FIGURE 2Nonport side of the Brocade VDX 8770-8 (sample configuration)
8 of 34Brocade VDX 8770-8 QuickStart Guide
Publication Number: 53-1002555-01
Items included with the Brocade VDX 8770-8
NOTE
The Brocade VDX 8770-8 ships with the following items:
• Brocade VDX 8770-8 chassis, populated with: (management modules, switch fabric modules, and line cards are
all packaged separately)
-Management modules (one)
-Switch fabric modules (up to six)
-Line cards (up to eight)
-Filler panels for unoccupied slots for all modules
-Power supplies (up to eight)
-Power supply filler panels for unoccupied bays
-Fan assemblies (four)
• Accessory kit containing the following items:
-Console cable (RS-232 serial cable: The RS-232 cable has an adapter at one end that can be removed to
Order the Brocade-branded transceivers (SFP, SFP+, or QSFP) and cables or direct-attach cables from your Brocade
distributor. The Brocade VDX 8770-8 supports SR and LR SFP and SFP+ transceivers. The QSFP transceivers are SR
transceivers only.
For information about the transceivers that are qualified for the Brocade VDX 8770-8, refer to
Brocade VDX 8770-8 QuickStart Guide9 of 34
Publication Number: 53-1002555-01
Preparing for the Brocade VDX 8770-8 installation
NOTE
NOTE
CAUTION
DANGER
Refer to the safety notices before installation (“Safety notices”).
Refer to “Power specifications” to plan for meeting power supply standards before installing the chassis.
Refer to “Environmental requirements” to plan for your environmental needs.
Refer to “Managing cables” to plan for cable management.
The following steps are required to ensure correct installation and operation.
1. Provide a space that is 15 rack units (15U) high, 61.29 cm (24.09 in.) deep, and 43.74 cm (17.22 in.) wide. One
rack unit is equal to 4.45 cm (1.75 in.).
Plan to install the Brocade VDX 8770-8 with the port side facing the air-intake aisle. Airflow is from the port side
of the switch to the fan side.
Ensure that the rack is balanced and mechanically secured to provide stability in the event of an earthquake
and that the equipment does not exceed the rack’s weight limits.
Doorways must be wider than 91 cm (36 in.) to accommodate the switch.
2. Ensure that dedicated electrical branch circuits with the following characteristics are available:
• Up to eight dedicated fused 200–240 VAC, 50–60 Hz feeds or -48 VDC (one per power supply)
• One cable for each power supply
Use a separate branch circuit for each AC power cord for redundancy in case one of the circuits fails.
• Protected by a circuit breaker in accordance with local electrical codes
• Supply circuit, line fusing, and wire size adequate to the electrical rating on the switch nameplate
• Location close to the switch and easily accessible
• Grounded outlets installed by a licensed electrician and compatible with the power cords
If the installation requires a different power cord than the one supplied with the switch, make sure you
use a power cord displaying the mark of the safety agency that defines the regulations for power cords in
your country. The mark is your assurance that the power cord can be used safely with the switch.
3. Plan for cable management before installing the switch.
Cables can be managed in a variety of ways, such as by routing cables below the switch, to either side of the
switch, through cable channels on the sides of the rack, or by using patch panels.
4. Ensure that the following items are available for configuration of the Brocade VDX 8770-8:
• Workstation with an installed terminal emulator, such as HyperTerminal
• Console (serial) cable (provided)
• Ethernet cables (not provided)
10 of 34Brocade VDX 8770-8 QuickStart Guide
Publication Number: 53-1002555-01
• Either access to an FTP server or a Brocade USB device for backing up the switch configuration or collecting
CAUTION
supportsave output data (optional)
• Transceivers (copper and optical) and compatible cables and direct-attach cables if needed
5. Ensure that the air intake and exhaust vents have a minimum of 5.1 cm (2 in.) of airspace.
6. Ensure that the air temperature on the air intake side is less than 40°C (104°F) during operation.
Power specifications
Power for the Brocade VDX 8770-8 can be supplied with either AC- or DC-based 3000 watt power supplies. The
Brocade VDX 8770-8 has room for up to eight power supplies.
Tab le 2 shows the basic power specifications for each power supply.
.
TABLE 2Power specifications
SpecificationValue for 3000W AC power supplyValue for 3000W DC power supply
Input rating16A70A
Input voltage200–240 VAC, 50-60 Hz, 16.0 Amp
maximum
Operating range180 ot 264 VAC-40 to -60 VDC
Inrush currentLimited to 60 Amp peak for any initial
current surge or spike of 10 ms or less at
either cold or warm start. Any additional
inrush current surges or spikes in the form
of AC cycles or multiple AC cycles greater
than 10 ms and less than 150 ms, must not
exceed 25 Amp peak.
Output12 VDC, 245 Amps12 VDC, 245 Amps
-48 VDC
Limited to 70 Amp peak for any initial
current surge or spike of 10 ms or less at
either cold or warm start.
For the DC input circuit to the system of a Brocade VDX 8770-8 (3000W power supply), make sure there
is an 80 Amp circuit breaker, minimum -48 VDC, double pole, on the input lugs to the power supply. The
input wiring for the connection to the switch should be copper wire, 2 American Wire Guage (AWG),
marked VW-1, and rated minimum 90°C.
The power requirements for a given switch configuration depend on which modules have been installed in the
switch. Tabl e 3 shows the power consumption for the modules that can be used in the Brocade VDX 8770-8 switch
along with the power consumption for the cooling fans.
All numbers for the line cards assume that the card is fully populated with optical transceivers, including QSFPs for
the 12x40 GbE line cards. All ports are Ethernet.