ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, ICX, MLX, MyBrocade, OpenScript, VCS, VDX, and
Vyatta are registered trademarks, and HyperEdge, The Effortless Network, and The On-Demand Data Center are trademarks of
Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names
mentioned may be trademarks of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning
any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to
this document at any time, without notice, and assumes no responsibility for its use. This informational document describes
features that may not be currently available. Contact a Brocade sales office for information on feature and product availability.
Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with
respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that
accompany it.
The product described by this document may contain “open source” software covered by the GNU General Public License or other
open source license agreements. To find out which open source software is included in Brocade products, view the licensing
terms applicable to the open source software, and obtain a copy of the programming source code, please visit
http://www.brocade.com/support/oscd.
Brocade Communications Systems, Incorporated
Corporate and Latin American Headquarters
Brocade Communications Systems, Inc.
130 Holger Way
San Jose, CA 95134
Tel: 1-408-333-8000
Fax: 1-408-333-8101
E-mail: info@brocade.com
European Headquarters
Brocade Communications Switzerland Sàrl
Centre Swissair
Tour B - 4ème étage
29, Route de l'Aéroport
Case Postale 105
CH-1215 Genève 15
Switzerland
Tel: +41 22 799 5640
Fax: +41 22 799 5641
E-mail: emea-info@brocade.com
Asia-Pacific Headquarters
Brocade Communications Systems China HK, Ltd.
No. 1 Guanghua Road
Chao Yang District
Units 2718 and 2818
Beijing 100020, China
Tel: +8610 6588 8888
Fax: +8610 6588 9999
E-mail: china-info@brocade.com
Asia-Pacific Headquarters
Brocade Communications Systems Co., Ltd. (Shenzhen WFOE)
Citic Plaza
No. 233 Tian He Road North
Unit 1308 – 13th Floor
Guangzhou, China
Tel: +8620 3891 2000
Fax: +8620 3891 2111
E-mail: china-info@brocade.com
Document History
Document titlePublication numberSummary of changesDate
Brocade VDX 6710-54 Hardware Reference
Manual
Brocade VDX 6710-54 Hardware Reference
Manual
Brocade VDX 6710-54 Hardware Reference
Manual
Brocade VDX 6710-54 Hardware Reference
Manual
53-1002390-01New documentSeptember
53-1002390-02Added KAP and RLO
information. Made
smaller corrections to
certifications.
53-1002390-03Added Canadian French
translation of
compliance statement.
Serial cable pinouts
added.
53-1002390-04Serial cable pinout
information corrected.
2011
December 2011
February 2012
March 2012
Document titlePublication numberSummary of changesDate
Brocade VDX 6710-54 Hardware Reference
Manual
Brocade VDX 6710-54 Hardware Reference
Manual
Brocade VDX 6710-54 Hardware Reference
Manual
Brocade VDX 6710-54 Hardware Reference
Manual
53-1002390-05Rack mount kit
information corrected.
Added CCC statement.
53-1002390-06Management options for
the switch have been
updated.
53-1002390-07Rack mount kit
information corrected.
53-1002390-08Optical port LED patterns
updated. Added USB
device to items included,
new information for
configuration when Layer
3 code is loaded,
removed ‘Brocadeapproved” text for directattach cables, made
slight adjustments to
physical specs.
• The LED patterns for the 1 GbE ports have been updated. Refer to “LED patterns.”
Document conventions
This section describes text formatting conventions and important notice formats used in this
document.
Text formatting
The narrative-text formatting conventions that are used are as follows:
bold textIdentifies command names
Identifies the names of user-manipulated GUI elements
Identifies keywords and operands
Identifies text to enter at the GUI or CLI
italic textProvides emphasis
Identifies variables
Identifies paths and Internet addresses
Identifies document titles
code textIdentifies CLI output
Identifies command syntax examples
For readability, command names in the narrative portions of this guide are presented in mixed
lettercase: for example, switchShow. In actual examples, command lettercase is all lowercase.
Command syntax conventions
Command syntax in this manual follows these conventions:
commandCommands are printed in bold.
--option, optionCommand options are printed in bold.
-argument, argArguments.
[ ]Optional elements appear in brackets.
variableVariables are printed in italics. In the help pages, values are underlined
enclosed in angled brackets < >.
...Repeat the previous element, for example “member[;member...]”
valueFixed values following arguments are printed in plain font. For example,
--show WWN
|Boolean. Elements are exclusive. Example:
--show -mode egress | ingress
or
xivBrocade VDX 6710-54 Hardware Reference Manual
53-1002390-08
Command examples
NOTE
ATTENTION
CAUTION
DANGER
This book describes how to perform configuration tasks using the Network OS command line
interface, but does not describe the commands in detail. For complete descriptions of all Network
OS commands, including syntax, operand description, and sample output, see the Brocade Network OS Command Reference Guide.
Notes, cautions, and warnings
The following notices and statements are used in this manual. They are listed below in order of
increasing severity of potential hazards.
A note provides a tip, guidance, or advice, emphasizes important information, or provides a
reference to related information.
An Attention statement indicates potential damage to hardware or data.
A Caution statement alerts you to situations that can be potentially hazardous to you or cause
damage to hardware, firmware, software, or data.
A Danger statement indicates conditions or situations that can be potentially lethal or extremely
hazardous to you. Safety labels are also attached directly to products to warn of these conditions
or situations.
Key terms
For definitions specific to Brocade and Fibre Channel, see the technical glossaries on MyBrocade.
See “Brocade resources” on page xvi for instructions on accessing MyBrocade.
For definitions of SAN-specific terms, visit the Storage Networking Industry Association online
dictionary at:
http://www.snia.org/education/dictionary
Notice to the reader
This document may contain references to the trademarks of the following corporations. These
trademarks are the properties of their respective companies and corporations.
For additional Brocade documentation, visit the Brocade website:
http://www.brocade.com
Release notes are available on the MyBrocade website.
Other industry resources
For additional resource information, visit the Technical Committee T11 website. This website
provides interface standards for high-performance and mass storage applications for Fibre
Channel, storage management, and other applications:
http://www.t11.org
For information about the Fibre Channel industry, visit the Fibre Channel Industry Association
website:
http://www.fibrechannel.org
Getting technical help
Contact your switch support supplier for hardware, firmware, and software support, including
product repairs and part ordering. To expedite your call, have the following information available:
1. General Information
• Switch model
xviBrocade VDX 6710-54 Hardware Reference Manual
53-1002390-08
• Switch operating system version
• Error numbers and messages received
• copy support command output
• Detailed description of the problem, including the switch or fabric behavior immediately
following the problem, and specific questions
• Description of any troubleshooting steps already performed and the results
• Serial console and Telnet session logs
• syslog message logs
2. Switch Serial Number
The switch serial number and corresponding bar code are provided on the serial number label,
as illustrated below:
*FT00X0054E9*
FT00X0054E9
The serial number label is located on the switch ID pull-out tab located on the bottom of the
port side of the switch.
3. World Wide Name (WWN)
Use the licenseIdShow command to display the WWN of the chassis.
Document feedback
Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and
completeness of this document. However, if you find an error or an omission, or you think that a
topic needs further development, we want to hear from you. Forward your feedback to:
documentation@brocade.com
Provide the title and version number of the document and as much detail as possible about your
comment, including the topic heading and page number and your suggestions for improvement.
The Brocade VDX 6710-54 is a top-of-rack switch designed to accommodate traditional 1 Gigibit
Ethernet (GbE) server connections to the Brocade 10 GbE VCS™ technology. The Brocade VDX
6710-54 features Brocade’s CloudPlex™ architecture and runs on the Brocade Network Operating
System (Network OS) v2.1.0. For details about Network OS, refer to the Brocade Network OS Administrator’s Guide.
The Brocade VDX 6710-54 switch offers 48 1 GbE, direct-attach copper ports along with 6 10 GbE
SFP+ optical ports.
1
A key feature of the Brocade VDX 6710-54 switch is Brocade VCS™ technology, which includes
virtual cluster switching, a new set of technologies that allows users to create flatter, virtualized,
and converged data center networks. VCS fabrics are scalable, permitting users to expand at their
own pace, and simplified, allowing users to manage the fabric as a single entity. VCS-based
Ethernet fabrics are convergence-capable, with technologies such as Fibre Channel over Ethernet
(FCoE) for storage.
Another feature of the Brocade VDX 6710-54 switch is reversible airflow. You can order fans that
move air either port side to nonport side or nonport side to port side depending on your needs.
Platform components and capabilities
The Brocade VDX 6710-54 switch offers the following features and capabilities:
• A system motherboard that features a Reduced Instruction Set Computer (RISC) CPU running
at 1.3 GHz with integrated peripherals
• An RJ45 10/100/1000 Ethernet out-of-band management port
• An RJ45-fronted serial (RS-232) port for terminal access
• A USB port for firmware upgrades and system log downloads
• Dual, hot-swappable 250W AC power supplies with three integrated cooling fans each, or
• Support for long-range and short-range SFP+ 10 GbE transceivers
• Support for optical cables and active twin axial (twinax) copper cables
• Support for direct-attach copper cables
• Support for inter-switch link (ISL) trunking
• A rack-mount design using existing rail kits (fixed and mid-mount or Telco rail kits) on a 19-inch
• Extensive diagnostics and system-monitoring capabilities for enhanced high Reliability,
• Optimized airflow (a choice of front-to-back or back-to-front flow)
• A real-time clock (RTC) with battery
• SEEPROM for switch identification
• Voltage monitoring
• Fan monitoring
• Three temperature sensors
• I2C interface to monitor and control environmental aspects
dual, hot-swappable 12V 250 W DC power supplies with three integrated cooling fans each
-Frame-level hardware-based trunking (even distribution of frames across trunk links)
EIA rack (also suitable for reduced-depth racks)
Availability, and Serviceability (RAS)
Port numbering for the Brocade VDX 6710-54 begins with 1, not 0.
Software features
The Brocade VDX 6710-54 switch supports the following features. For more details on these
features, refer to the Brocade Network OS Administrator’s Guide.
Layer 2 and Layer 3 security features
• VLANs
• Spanning Tree Protocol (STP, RSTP, MSTP and PVST+ and PVRST+)
• Support for unicast and multicast capabilities
• Support for IGMP snooping
• Layer 2 multi-path based on Transparent Interconnection of Lots of Links (TRILL)
• Layer 2 access control lists (ACLs)
• Switch Port Analyzer (SPAN) (also known as port mirroring)
• Management access ACLs
Virtualization
• Automatic Migration of Port Profiles (AMPP)
2Brocade VDX 6710-54 Hardware Reference Manual
53-1002390-08
Views of the Brocade VDX 6710-54 switch
• Support for VLAN, QoS, security, and FCoE port profiles
• Virtual Machine-aware network automation
Link aggregation
• 802.3ad LACP support
• Virtual Link Aggregation Group (vLAG) (a LAG that spans multiple physical switches)
• TRILL Operations, Administration, and Management (OAM)
• Distributed configuration management (DCM)
Licensing
• VCS licensing: Available multi-node license up to 24 nodes (enables Ethernet Fabric
functionality)
Views of the Brocade VDX 6710-54 switch
The port side of the Brocade VDX 6710-54 switch includes the system LEDs, management ports
and LEDs, USB port, and Gigabit Ethernet (GbE) ports and the corresponding port status LEDs.
Figure 1 shows the port side of the Brocade VDX 6710-54.