TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring (including switch location) must be done by a qualified person(s) in accordance
with all applicable codes and standards, including fire-rated
construction.
4. Provide sufficient air for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the combustion equipment
standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE),
and local codes.
5. This product may have sharp edges. Be careful to avoid cuts
and abrasions during installation and cleaning.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Use only metal
9. Do not use this fan with any solid-state speed control device.
10. As an alternative, this product may be installed with the ULapproved cord kit designated for the product, following instructions packed with the cord kit.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
3. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for
the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal t r ay, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
ductwork.
WARNING
2. NEVER PICK UP A FLAMING PAN — You may be burned or
spread the fire.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Firesafety Tips” published by NFPA.
CAUTION
1. F o r indoor use only.
2. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced impeller, keep drywall spray, construction dust, etc.,
off power unit.
4. Do not use over cooking equipment greater than 60,000
BTU/hr. as the blower motor will shut down intermittantly.
5. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor
will restart when it cools down. If the motor continues to shut
off and restart, have the hood serviced.
6. The top of the hood MUST NOT BE LESS than 24” and at a
maximum of 30” above
impurities.
7. This hood is not intended to be used as a shelf.
8. Please read specification label on product for further information and requirements.
NOTE If hood is to be installed non-ducted:
Purchase a set of (3) non-ducted filters (Model
BPPF42) from your local distributor or retailer and
attach them to the aluminum mesh filters.
Register your product online at: www.broan.com
Installer: Leave this manual
with the homeowner.
Homeowner: Cleaning, Maintenance and
Operating instructions on page 2.
cookt
op for best capture of cooking
MODELS QP142SS • QP142WW • QP142BL
Page 2
CONTENTS
INCLUDED WITH THE HOOD:
(3)
GREASE
FILTERS
(1) PARTS BAG CONTAINING:
(3)
WIRE
NUTS
(9)
#8 X 1/4”
DUCT
CONNECTOR
SCREWS
CUP TOOL
#10 X 5/8”
RD. HD.
MOUNTING
SCREWS
(1)
BULB
SUCTION
(5)
DAMPER / DUCT
CONNECTOR
(1) 7” ROUND
DUCT
CONNECTOR
#8 WASHERS
FOR NON-DUCT
(1) 3¼” X 10”
(1)
NON-DUCT
DIVERTER
(2)
#8 X 5/16”
MACHINE
SCREWS
&
(2)
DIVERTER
OPERATION
Always turn the hood ON before cooking in order to establish an
air flow in the kitchen. After turning off the range, let the hood run
for a few minutes to clear the air.
Operate the hood as follows:
120
BLOWER SWITCH
This 3-position rocker switch turns blower ON and OFF and
controls blower speed.
Left rocker position (0) turns blower OFF.
Center rocker position (1) turns blower ON to low speed.
Right rocker position (2) turns blower ON to high speed.
LIGHT SWITCH
This 3-position rocker switch turns lights ON and OFF and controls
their intensity.
Left rocker position (0) turns lights OFF.
Center rocker position (1) turns lights ON to low intensity.
Right rocker position (2) turns lights ON to high intensity.
NOTE
This hood utilizes an offset blower design to achieve greater
performance and lower sound levels. As a result, you may notice
that cooking impurities are more attracted to one side or appear
to be pulled-in faster than they appear on the opposite side. This
is completely normal. The hood has been designed and tested
to provide good capture of cooking impurities and odors under
all normal cooking conditions regardless of the cooking location
on the cooktop. Please note that cooking on the rear burners will
always result in the best capture of cooking impurities, regardless
of the hood design.
120
CLEANING & MAINTENANCE
For performance, appearance, and health reasons, clean filter,
fan and grease-laden surfaces. Use only a clean cloth and mild
detergent solution on stainless and painted surfaces.
Clean all-metal filters in the dishwasher using a non-phosphate
detergent. Discoloration of the filter may occur if using phosphate
detergents, or as a result of local water conditions - but this will
not affect filter performance. This discoloration is not covered by
the warranty.
Clean the non-duct recirculating filter surfaces frequently with
a damp cloth and a mild detergent. DO NOT immerse filters in
water or put in dishwasher. The special “Clean Sense” feature
indicates when the filter is to be replaced. The blue and yellow
strips will blend to green when it is time to change the filter. The
“Clean Sense” feature works best when facing toward the cooking surface. Change the non-duct recirculating filters every 6
months. For replacement non-duct recirculating filters - purchase
S99010360 or Model BPPF42.
The motor is permanently lubricated and never needs oiling. If
the motor bearings make excessive or unusual noise, replace
the motor with the exact service motor. The impeller should also
be replaced.
Use 120 V, 35 W, shielded halogen bulbs - MR16 with GU10 base.
urchase bulbs separately.
P
PREPARE HOOD LOCATION
ROOF CAP
SOFFIT
CABINET
HOODHOOD
24" - 30" ABOVE
COOKING SURFACE
1 Determine whether hood will discharge vertically (3¼”
x 10” or 7” Round), or horizontally (3¼” x 10” only). For
vertical or horizontal discharge, run ductwork between
the hood location and a roof cap or wall cap. For best
results, use a minimum number of transitions and
elbows.
3¼" X 10" or
7" ROUND DUCT
(For vertical
discharge)
HOUSE WIRING
(Top or Back of hood)
WALL CAP
3¼" X 10" DUCT
(For horizontal discharge)
MODELS QP142SS • QP142WW • QP142BL
Page 3
2 Use the proper diagram below, for placement of ductwork
and electrical cutout in cabinet or wall. For a non-ducted
installation, DO NOT cut a duct access hole.
HOOD MOUNTING SCREWS (5)
5
/
"
8
17
CABINET FRONT
CABINET
BOTTOM
4½"
¾"
WOOD SHIMS
(recessed-bottom
cabinets only)
5¼"
*
VERTICAL DUCT
ACCESS HOLE
5¼"
CENTER
LINE
WOOD SHIMS
(recessed-bottom
cabinets only)
CABINET FRONT
17
7
/
6
"
8
(in cabinet bottom)
HORIZONTAL DUCTING
3¼” X 10”
VERTICAL DUCTING
5
/
"
8
1
11"
/
2
"
8
ELECTRICAL
ACCESS HOLE
10
5
/
"
2
8
3¼” X 10”
13/8"
3
/8"
7
/
"
8
PREPARE THE HOOD
3 Remove parts bag from inside the hardware box included
with the hood.
4 Remove all protective polyfilm from the hood (stainless
steel hoods only).
ç
(1)
ç
PULL
DOWN
ALUMINUM
FILTERS
(2)
LIFT
OUT
5 Remove the Aluminum Filters from the hood.
HORIZONTAL DUCT
4"
CABINET
BOTTOM
ACCESS HOLE
5¼"
175/8"175/8"
HOOD
MOUNTING
SCREWS (5)
CENTER
LINE
HOOD MOUNTING SCREWS (5)
17
5/8"
8" DIA.
HOLE
45/8"
7-IN. ROUND
7-IN. ROUND
DUCT
DUCT
ACCESS
ACCESS
HOLE
HOLE
*
*
5¼"
67/8"
ELECTRICAL
ACCESS HOLE
17
5/8"
6
7/8"
11"
21/8"
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
(in wall)
7” ROUND
DUCTING
BOTTOM
PAN
6 Remove 6 Screws holding Bottom Pan to hood. Set bot-
to hood. Remove damper/duct connector from inside the
hood.
FOR DUCTED INSTALLATIONS - Skip to Step 12.
NON-DUCT
DIVERTER
AIR BOX
8 NON-DUCTED INSTALLATION ONLY:
From parts bag: Attach Non-Duct Diverter to Air Box
with 2 Screws and 2 Washers.
MODELS QP142SS • QP142WW • QP142BL
Page 4
SCREWS
NON-DUCT
PLATE
ç
NON-DUCT
PLATE
SCREWS
NON-DUCT
PLATE
10 NON-DUCTED INSTALLATION ONLY:
Insert short end of Non-Duct Plate into Non-Duct
Plenum Slot. Attach with 2 Screws removed in Step 9.
11 NON-DUCTED INSTALLATION ONLY:
Purchase a set of (3) non-ducted filters (Model BPPF42)
from your local distributor or retailer. Attach the non-ducted filters to the aluminum mesh filters following instructions packed with the non-ducted filters.
FOR NON-DUCTED INSTALLATIONS - Skip to “INSTALL
THE HOOD”.
SLOT
NON-DUCT
PLENUM
9 NON-DUCTED INSTALLATION ONLY:
Remove 2 Screws holding Non-Duct Plate to Non-Duct
Plenum and remove plate.
MODELS QP142SS • QP142WW • QP142BL
Page 5
7” ROUND
KNOCKOUT
PLATE (also
remove 3¼” x 10”
vertical plate)
3¼” X 10”
VERTICAL
KNOCKOUT
3¼” X 10”
HORIZONTAL
KNOCKOUT
PLATE
12 DUCTED INSTALLATION ONLY:
Remove 3¼” x 10 vertical, 3¼” x 10” horizontal, or 7-inch
round knockout plate(s) as appropriate for your ducting
method.
3¼” X 10”
DAMPER /
DUCT
CONNECTOR
TOP/BACK
EDGE OF
HOOD
PLATE
DAMPER
FLAP
PIVOT
INSTALL THE HOOD
WARNING
To reduce the risk of electrical shock, switch power off
at service panel. Lock or tag service panel to prevent
power from being switched on accidentally.
ELECTRICAL
WIRING BOX
COVER
ELECTRICAL
POWER
CABLE
KNOCKOUT
14 Remove Electrical Wiring Box Cover from inside
of hood and appropriate Electrical Power Cable Knockout from top or back of hood.
7” ROUND
DUCT
PLATE
13 DUCTED INSTALLATION ONLY:
Attach 3¼” x 10” Damper/Duct Connector (if using 3¼”
x 10” duct) or 7” Round Duct Plate (if using 7-inch round
duct) over the knockout opening.
Notes:
To accomodate off-center ductwork, the 3¼” x 10”
damper/duct connector can be installed up to ½” on either
side of the hood center and the 7” round duct plate can
be installed up to ½” on either side of the hood center.
Install the 3¼” x 10” Damper/Duct Connector with the
Damper Flap Pivot nearest the Top/Back Edge of
Hood.
HOUSE
POWER CABLE
15 Run House Power Cable between service panel and hood
location. Attach power cable to hood using appropriate clamp.
16 Hang hood from (4) mounting screws driven part-way into
cabinet locations (shown in illustrations under “PREPARE
HOOD LOCATION”). Mounting screws are included in parts
bag. Slide hood back towards wall until mounting screw
heads are engaged in narrow end of keyhole slots in top of
hood. Tighten screws securely. Add 5th mounting screw in
center hole in hood and tighten securely.
17 DUCTED INSTALLATION ONLY:
Connect ductwork to hood and use duct tape to make joints
secure and air-tight. Make sure the damper / duct connector
enters the ductwork and that the damper opens and closes
freely.
CONNECT THE WIRING
GROUND
SCREW
MODELS QP142SS • QP142WW • QP142BL
Page 6
LAMP SOCKET
BRACKET
HOUSE
POWER CABLE
18 Connect House Power Cable to range hood wiring -
BLACK to BLACK, WHITE to WHITE, and GREEN or
BARE WIRE to Ground Screw. Replace electrical wiring
box cover.
19 Re-attach Bottom Pan with 6 Screws removed in Step 6.
INSTALL LIGHT BULBS
SUCTION
CUP TOOL
HALOGEN
BULB
(2)
ROTATE
CLOCKWISE
LIGHT PANEL
SCREWS
CAUTION: Bulbs may be hot. Refer to bulb
packaging for further information.
Install aluminum filters and non-ducted filters - purchased
and assembled in Step 11.
WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such
products will be free from defects in materials or workmanship for a period of one
(1) year from the date of original purchase. THERE ARE NO OTHER WARRANTIES,
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one year period, Broan-NuTone will, at its option, repair or replace, without
charge, any product or part which is found to be defective under normal use and
service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS,
TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF
CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does
not cover (a) normal maintenance and service or (b) any products or parts which have
been subject to misuse, negligence, accident, improper maintenance or repair (other
than by Broan-NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of any implied warranty is limited to the one year period as specified for the
express warranty. Some states do not allow limitation on how long an implied warranty
lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S
OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER
THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION
WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation or exclusion
may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or
telephone number below, (b) give the model number and part identification and (c)
describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027
www.broan.com 800-558-1711