Broan NuTone Eclipse 2830, NuTone Eclipse 2836 Specification Sheet

MODELS 2830 & 2836
ECLIPSE
REMOTE DOWNDRAFT
SPECiFiCATiON SHEET
Control a powerful exterior blower from the cooktop location.
FEATURES HOUSING:
Finished with black, electrically-bonded epoxy paint
Space-saving - can be used with most cooktops on the market
30" or 36" size - Fits standard-size cabinets
AIR VENT ASSEMBLY:
® Brushed stainless steel cover - just press button
to turn unit "ON"
Designer White or Black doors - available
separately
Air vent rises to 7" from cooktop for optimum removal of cooking contaminants
Two washable aluminum grease filters
Stainless steel face plate - makes cleanup quick
and easy
Flush-mounted, infinite speed blower control
Conveniently located button - press to lower air
vent and turn unit "OFF"
TYPICAL SPECiFiCATiON
Downdraft blower system shall be Broan Model 2830 (Broan Model 2836).
Unit to have steel housing with electrically-bonded paint finish. Air vent to rise at least 7" and have a stainless steel
face plate for ease of cleaning. Filters to be washable and removable from above.
31_'' x 10" duct connector shall be adjustable to accomodate different duct positions.
Downdraft system shall operate on 120 VAC and be able to be plugged into a standard grounded outlet. It will have
an infinite speed blower control.
SPECIFICATIONS
VOLTS Hz AMPS
120 60 6 Amps
DISCHARGE
31_" x 10"
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
REFERENCE
QTY. REMARKS Project
Location
Architect
Engineer Contractor
Submitted by
Date
20G 99041821E
iNSTALLATiON PLANNING - MODELS 2830 & 2836
DiMENSiONS
NOTE: Dimensions shown are for reference only. Before cutting out countertop, refer to instructions packed with downdraft and cooktop.
DOWNDRAFT
A
COOKTOP
DOWNDRAFT
-- FRONT TO BACK -- INSIDE CABINET DEPTH I
I
Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements. The 2830
and 2836 can be installed in most standard 30" and 36" wide cabinets.
Cooktop depth can vary greatly from one to another. This may cause the fit of these two appliances to be rather tight.
Pay special attention to the 4 areas of potential interference highlighted above. The back of the downdraft cut-out will be 1-3/ 4" from the cooktop and 2" of FLAT countertop is needed behind cooktop.
DUCTWORK
TYPICAL iNSTALLATiON
COUNTER
TOP COOKTOP
VENT
3-1/4"x10" DUCTCONNECTOR
CHIMNEYTOP
/
7 7/8
1
3 5/8
4.
120VAC GROUNDED
OUTLET
The downdraft has 31A"x 10" discharge. Transitions are available to connect it to the 10" round inlet on the Broan Models 331 or 332
exterior blowers. See below.
3¼"X10"
DUCT CONNECTOR
3-1/4" x 10"
TRANSITION __
TO 8"
3-1/4" X 10"
8" x 10" TO
INCREASER
8" RD,
ELBa6 FT,
ELECTRICAL
The unit has a 2 ft. power cord with a 3-pronged plug. Plan to provide a grounded outlet within reach of this cord. Outlet may
also be wall-mounted, with access hole in cabinet. If local codes call for hard-wiring, see installation instructions.
The system will operate most efficiently when the ductwork does not exceed 40 feet of equivalent duct. The illustrations above, show equivalent feet of elbows and transitions. The number of feet of straight 3-1/4" x 10" or 6" duct plus the equivalent feet of elbows or transitions to be used should equal 40 feet or less.