MODELS 165F AND 167F
FAN FORCED WALL HEATERS
FINISH ASSEMBLIES
FOR USE WITH BROAN MODEL 171H ROUGH-IN HOUSING
READ AND SAVE THESE INSTRUCTIONS
WARNING
1. ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH LOCAL OR NATIONAL ELECTRICAL CODE
AS APPLICABLE. FOR SAFETY, THIS PRODUCT MUST
BE GROUNDED. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE
THE SERVICES OF A QUALIFIED ELECTRICIAN.
2. WHEN WIRING, SERVICING OR CLEANING THIS UNIT,
TURN OFF POWER AND LOCK OUT SERVICE PANEL.
FAILURE TO DO SO COULD ALLOW OTHERS OR THERMOSTAT TO TURN ON POWER UNEXPECTEDLY WHICH
MAY CAUSE FATAL ELECTRICAL SHOCK.
3. To avoid electrical shock:
• DO NOT install unit in a tub or shower enclosure or any
location where it may come in contact with water.
• NEVER place a switch where it can be reached from a
tub or shower.
4. DO NOT install this unit in an area where chemicals or
other flammables are stored or used. Explosion and fire
may result
.
PLAN THE INSTALLATION
This wall heater finish assembly is intended for installation
into a Broan Model 171H rough-in housing — after the wall
has been completed.
The heater can be operated using the Broan Model 86 LineVoltage Thermostat from a wall location or the Broan Model
83 Integral Thermostat installed into heater. Purchase the control separately.
CAUTION
1. This product may ONLY be installed horizontally in a wall.
DO NOT MOUNT IN ANY OTHER POSITION.
2. Install heater at least 6” from floor or any adjacent vertical
surface.
3. DO NOT locate heater behind a door, furniture, drapes,
etc., where the air flow to the unit would be restricted.
4. Provide heater with an appropriately-rated electrical circuit to prevent tripped breakers or blown fuses. (See chart
below).
5. DO NOT CONNECT HEATER TO DIMMER SWITCH OR
SPEED CONTROL.
6. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust,
etc., off power unit.
7. Please read specification label on product for further information and requirements.
Follow these basic steps when installing this heater:
• Remove the housing mask.
• Fasten finish assembly inside housing.
• Plug assembly in.
• Attach grille.
The table below lists the ratings for each model.
MODELS VOLTS AMPS WATTS BTU/HR
165F 120 4.17 500 1707
240 2.08 500 1707
208 1.8 375 1280
167F 240 3.13/6.25 750/1500 2560/5120
208 2.71/5.41 563/1125 1922/3840
BOLD ratings are factory wired. See "OPTIONAL WIRING
CONVERSIONS" section on pages 2 and 3 for wattage and
voltage conversion instructions.
DRYWALL
GRILLE
WALL
STUD
HEATER
HEATER
HOUSING
HOUSING
POWER
CABLE
INSTALL THE HEATER ASSEMBLY OPTIONAL WIRING CONVERSIONS
1. Remove housing mask.
Make sure wall has been finished (including paint or wall
paper, etc.) Take out and discard the cardboard mask from
inside of housing.
FASTEN TO
HOUSING WITH
TABS
2. Install heater assembly into housing.
Place element end of heater assembly behind the tabs on
the left side of housing. Pivot the assembly in and fasten
with retaining screw from parts bag.
Plug wiring harness into receptacle.
RETAINING SCREW -
HERE
MODEL 165F
WHITE WIRES
BLACK WIRE
(from motor)
240 VAC to 120 VAC Conversion.
This heater can be converted to operate on 120 VAC.
1)Disconnect black wire from white wire.
(2) WHITE WIRES
3. Provide desired control.
The heater finish assembly has no adjustable thermostat
control.
If a wall-mounted control has been pre-wired, nothing else
need be done.
If a built-in thermostat is desired, purchase and insert the
Broan Model 83 Integral Thermostat at this time.
WIRING DIAGRAM
MODEL 165F
(2) BLACK
WIRES
(connected
to motor)
2)Connect the two (2) white wires with insulated terminals to
each other.
3)Connect black wire to terminal on motor.
2