Broan 124, 120, 128 User Manual

MODELS 120, 124 & 128 REGISTER HEATERS
MODELOS 120, 124 Y 128 CALENTADORES DE REJILLA
READ AND SAVE
THESE INSTRUCTIONS
IMPORTANT INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE
WARNING
INSTALLING OR USING THIS HEATER.
1. ALL ELECTRICAL WORK MUST BE DONE IN ACCOR-
To reduce the risk of fire, electric shock, or injury to persons,
DANCE WITH LOCAL OR NATIONAL ELECTRICAL
observe the following:
CODE AS APPLICABLE. FOR SAFETY, THIS PROD-
1. Use this unit only in the manner intended by the manufacturer. If
UCT MUST BE GROUNDED. IF YOU ARE UNFAMIL-
you have questions, contact the manufacturer at the address or
IAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED
telephone number listed in the warranty.
ELECTRICIAN.
2. Before servicing or cleaning unit, switch power off at service
2. WHEN WIRING, SERVICING OR CLEANING THIS
panel and lock the service disconnecting means to prevent
UNIT, TURN OFF POWER AND LOCK OUT SERVICE
power from being switched on accidentally. When the service
PANEL. FAILURE TO DO SO COULD ALLOW OTHERS
disconnecting means cannot be locked, securely fasten a
OR THERMOSTAT TO TURN ON POWER UNEX- PECTEDLY WHICH MAY CAUSE FATAL ELECTRICAL
prominent warning device, such as a tag, to the service panel.
SHOCK.
3. Installation work and electrical wiring must be done by a
3. To avoid electrical shock:
qualified person(s) in accordance with all applicable codes
DO NOT install unit in a tub or shower enclosure or
and standards, including fire-rated construction codes and
any location where it may come in contact with water.
standards.
NEVER place a switch where it can be reached from
4. When cutting or drilling into wall or ceiling, do not damage
a tub or shower.
electrical wiring and other hidden utilities.
4. DO NOT install this unit in an area where chemicals or other flammables are stored or used. Explosion and fire
5. This heater is hot when in use. To avoid burns, do not let bare
may result.
skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, etc. and curtains at least 3 feet (0.9 m) from the front of the heater.
CAUTION
6. Extreme caution is necessary when any heater is used by
1. This product may ONLY be installed horizontally in a wall.
or near children or invalids and whenever the heater is left
DO NOT MOUNT IN ANY OTHER POSITION.
operating and unattended.
2. Install heater at least 6" from floor or any adjacent vertical surface.
7. Do not operate any heater after it malfunctions. Disconnect
3. DO NOT locate heater behind a door, furniture, drapes,
power at service panel and have heater inspected by a reputable
etc., where the air flow to the unit would be restricted.
electrician before reusing.
4. Provide heater with an appropriately-rated electrical
8. Do not use outdoors.
circuit to prevent tripped breakers or blown fuses (See
9. To disconnect heater, turn controls to off, and turn off power
chart below.)
to heater circuit at main disconnect panel (or operate internal
5. DO NOT CONNECT HEATER TO DIMMER SWITCH
disconnect switch, if provided).
OR SPEED CONTROL.
10. Do not insert or allow foreign objects to enter any ventilation or
6. To avoid motor bearing damage and noisy and/or unbal- anced impellers, keep drywall spray, construction dust,
exhaust opening, as this may cause an electric shock or fire, or
etc., off power unit.
damage the heater.
7. Please read specification label on product for further
11. To prevent a possible fire, do not block air intakes or exhaust in
information and requirements.
any manner.
12. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable vapors or liquids
PLANNING
are used or stored.
This heater is intended to be used to supply supplemental
13. Use this heater only as described in this
heat from a wall location in new or existing construction.
manual. Any other use not recommended by the
The heater can be operated using the Broan Model 86
manufacturer may cause fire, electric shock, or
Line-Voltage Thermostat from a wall location. Purchase the control separately.
injury to persons.
Plan to supply the heater with proper line voltage and ap-
14. Install heater at least 6 inches from floor or any
propriate power cable.
adjacent wall.
NOTE: Power can be tapped from a nearby circuit depend-
15. To avoid electrical shock: Do not install unit in a
ing on the heater wattage required and the amperage rating
tub or shower enclosure or any location where
of the circuit.
it may come in contact with water. Never place
Heater can be converted to half-wattage to avoid overload- ing such circuits.
a switch where it can be reached from a tub or
The table below lists the ratings for each model.
shower.
16. This product may ONLY be installed horizontally in a wall. Do not mount in any other position.
17. Do not connect heater to dimmer switch or speed control.
18. This product must be grounded.
SAVE THESE INSTRUCTIONS
FIG. 1
DRYWALL/ PARED DE
YESO
GRILLE/ REJILLA
LEA Y CONSERVE
INSTRUCCIONES IMPORTANTES
LEA TODAS LAS INSTRUCCIONES ANTES DE INSTALAR O USAR ESTE CALENTADOR.
Para reducir el riesgo de incendios, descargas eléctricas o lesiones personales, observe las siguientes precauciones:
1. Use la unidad solo de la manera indicada por el fabricante. Si tiene preguntas, comuníquese con el fabricante a la dirección o al número telefónico que se incluye en la garantía.
2. Antes de dar servicio a la unidad o de limpiarla, interrumpa el suministro eléctrico en el panel de servicio y bloquee los medios de desconexión del servicio para evitar que la electricidad se reanude accidentalmente. Cuando no sea posible bloquear los medios de desconexión del servicio, fije firmemente una señal de advertencia (como una etiqueta) en un lugar visible del panel de servicio.
3. El trabajo de instalación y el cableado eléctrico deben estar a cargo de personal capacitado, de acuerdo con todos los códigos y normas correspondientes, incluidos los códigos y normas de construcción específicos sobre protección contra incendios.
4. Al cortar o perforar a través de la pared o del cielo raso, tenga cuidado de no dañar el cableado eléctrico ni otros servicios ocultos.
5. Este calentador se calienta cuando se usa. Para evitar quemaduras, no deje que la piel desnuda toque las superficies calientes. Mantenga materiales combustibles como muebles, almohadas, ropa de cama, papeles, ropa, etc., así como las cortinas, por lo menos a 3 pies (0.9 m) de la parte delantera del calentador.
6. Es necesario tener extremo cuidado cuando se use un calentador cerca de niños o personas inválidas, y siempre que el calentador se deje funcionando y sin atención.
7. No haga funcionar ningún calentador después de que presente una falla. Desconecte la energía eléctrica en el panel de servicio y pida que un electricista acreditado inspeccione el calentador antes de volverlo a usar.
8. No lo use en exteriores.
9. Para desconectar el calentador, mueva los controles a la posición de apagado y desconecte la energía eléctrica al circuito del calentador en el panel de desconexión principal (o active el interruptor de desconexión interna, si existe).
10. No inserte ni permita que objetos extraños entren en la abertura de ventilación o de escape, pues esto puede ocasionar una descarga eléctrica, un incendio o daños al calentador.
WALL
STUD/
VIGA DE
LA PARED
HEATER
HOUSING/
CAJA DEL
CALENTA-
DOR
POWER
CABLE/
CABLE
DE EN-
ERGIA
ADVERTENCIA
1. TODO EL TRABAJO ELECTRICO DEBE REALIZARSE DE ACUERDO CON LOS CODIGOS ELECTRICOS LOCALES Y/O NACIONALES CORRESPONDIENTES.
PARA SU SEGURIDAD, ESTE PRODUCTO DEBE SER CONECTADO A TIERRA. SI USTED NO ESTA
FAMILIARIZADO CON LOS METODOS DE INSTALACION DEL CABLEADO ELECTRICO, OBTENGA LOS SERVICIOS DE UN ELECTRICISTA COMPETENTE.
2. AL HACER EL CABLEADO, LIMPIEZA O DAR SERVICIO A ESTA UNIDAD, DESCONECTE LA POTENCIA Y ASEGURE EL PANEL DE SERVICIO. EL NO HACERLO PUEDE HACER POSIBLE QUE OTRAS PERSONAS O EL TERMOSTATO ACTIVE LA ENERGIA EN FORMA INESPERADA, LO QUE PUEDE CAUSAR UN GOPE ELECTRICO MORTAL.
3. Para evitar descarga eléctrica: * NO instale la unidad en una bañera o recinto de ducha,
ni en ningún lugar donde pueda entrar en contacto con el agua.
* NUNCA coloque un interruptor en un lugar que pueda
ser alcanzado desde una bañera o ducha.
4. NO instale esta unidad en un área donde se almacenen o usen productos químicos u otros productos inflamables. De lo contrario, pueden producirse explosiones e incendios.
CUIDADO
1. Este producto SOLAMENTE se puede instalar horizontal- mente en una pared. NO LO MONTE EN NINGUNA OTRA POSICION.
2. Instale el calentador por lo menos a 15,24 cm (6 pulg.) de distancia del piso o de alguna superficie vertical adyacente.
3. NO COLOQUE el calentador detrás de una puerta, muebles, cortinas, etc., donde el flujo de aire a la unidad se encuentre restringido.
4. Proporcione un circuito eléctrico de capacidad nominal al calentador, a fin de impedir la desconexión de disyuntores o quemado de fusibles. (Véase el diagrama abajo).
5. NO CONECTE EL CALENTADOR A UN VARIADOR DE LUZ O UN CONTROL DE VELOCIDAD.
6. Para evitar daños al cojinete del motor e impulsores ruidosos y/o desequilibrados, mantenga la unidad de energía alejada de rocíos de yeso, polvo de construcción, etc.
7. Para más información y requisitos, lea la etiqueta de especificación sobre el producto.
11. Para prevenir un posible incendio, no bloquee la entrada o salida del aire de ninguna manera.
PLANIFICACION
12. El calentador tiene piezas calientes y que pueden
Este calentador ha sido diseñado para proporcionar calefacción adi-
generar arcos eléctricos o chispas en el interior. No
cional desde una pared en una construcción nueva o una ya existente.
lo use en áreas donde se use o almacene gasolina,
El calentador se puede poner en funcionamiento desde una pared usando el termostato de tensión de línea Broan Modelo 86. Adquiera
pintura o vapores o líquidos flamables.
los controles en forma separada.
13. Use este calentador solamente como se describe en
Planifique proporcionar al calentador la tensión de línea y cable de
este manual. Cualquier otro uso no recomendado
energía eléctrica apropiados.
por el fabricante puede ocasionar un incendio, una
NOTA: La energía se puede tomar de un circuito cercano, lo que
descarga eléctrica o lesiones a personas.
dependerá del vatiaje requerido del calentador y amperaje nominal del circuito.
14. Instale el calentador por lo menos 6 pulg. desde el
El calentador se puede convertir a mitad de vatiaje para evitar sobre-
piso o cualquier pared adyacente.
cargar dichos circuitos.
15. Para evitar golpe eléctrico: No instale la unidad en una bañera o recinto de ducha. Nunca coloque un interruptor en un lugar que pueda ser alcanzado desde una bañera o ducha.
16. Este producto SOLAMENTE se puede instalar en una pared. No lo monte en ninguna otra posicion.
17. No conecte el calentador a un variador de luz o control de velocidad.
18. Este producto debe estar conectado a tierra.
GUARDE ESTAS INSTRUCCIONES
INSTALLER: Leave This Manual With The Homeowner. HOMEOWNER: Use and Care Information on Page 3.
INSTALADOR: Deje este manual con el dueño de casa. DUEÑO DE CASA: Información del uso y mantenimiento en la página 3.
1
Follow these basic steps when installing this heater.
PLANNING
Nail housing to studs.
Connect power cable.
This heater is intended to be used to supply
Fasten heater assembly and grille to
supplemental heat from a wall location in new
housing. (FIG. 1)
or existing construction. The heater can be operated using the Broan
Model 86W Line-Voltage Thermostat from a wall
PREPARATION
location. Purchase the control separately.
1. Remove the retaining screw, unplug wiring harness
Plan to supply the heater with proper line voltage
and lift heater assembly from housing. (FIG. 2)
and appropriate power cable.
2. Slide the wiring cover out of housing. (FIG. 3)
NOTE: Power can be tapped from a nearby circuit depending on the heater wattage required and the amperage rating of the circuit.
INSTALLATION
Heater can be converted to half-wattage to avoid
WARNING: To reduce the risk of fire, do not store or
overloading such circuits.
use gasoline or other flammable vapors and liquids in the vicinity of the heater.
The table below lists the ratings for each model.
CAUTION: High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other
MODELS
VOLTS
AMPS
4.16
3.61
6.25
5.41
WATTS
1000/500
1500 /750
2000/1000
1500/750
combustibles at least 3 feet (0.9 m) from the front of the heater and away from the side and rear.
(16"-ON-CENTER STUDS ONLY) NOTE: Locate housing at least 6" from the floor and
any adjacent walls.
1. Choose which side of housing will be mounted di- rectly to a wall stud. Then insert a mounting bracket from the opposite side into the channel at the top of the housing. (FIG. 4)
2. Use measuring guide on side of housing to posi-
BOLD ratings are factory wired. See "OPTIONAL
tion housing so that it will be flush with finished
WIRING CONVERSION" section for wattage and
wall. Drive to (2) nails through the holes on side of
voltage conversion instructions.
housing and into stud. (FIG. 5)
3. Extend mounting bracket, level housing, and nail
Follow these basic steps when installing this
to other stud. (FIG. 6)
heater.
(24"-ON-CENTER STUDS ONLY)
• Nail housing to studs.
1. Choose which side of housing will be mounted di- rectly to a wall stud. From this side, push a mounting
• Connect power cable.
bracket as far as possible into the channel at the
• Fasten heater assembly and grille to
top of the housing.
housing. (FIG. 1)
NOTE: Locate housing at least 6" from the floor and any adjacent walls.
2. Use measuring guide on side of housing to posi- tion housing so that it will be flush with finished
PREPARATION
wall. Drive two (2) nails through the holes in side
1. Remove the retaining screw, unplug wiring
of housing and into stud. (FIG. 7)
har ness and lift heater assembly from housing.
3. Secure the two (2) mounting brackets together (with screw supplied). Level housing and nail to opposite
(FIG. 2)
stud, as shown.
2. Slide the wiring cover out of housing. (FIG.
120
124
128
120
240 208 120 240 208
240
208
8.33/4.16
12.5/6.25
6.33/4.16
7.21/3.61
1000
750
1500 112 5
BTU/HR
3413/1707
3413 2560
5120/2560
5120 3840
6827/3413 5120/2560
3)
WIRING
(ALL INSTALLATIONS)
1. Feed electrical power cable through open knockout in corner of housing and attach with appropriate connector. Allow 6" of wire inside of housing.
NOTE: Use other housing knockout when wiring units in parallel. (FIG. 8)
2. Connect black to black, white to white. Use ground- ing clip to attach green or bare wire to housing. Replace wiring cover. (FIG. 9)
OPTIONAL WIRING CONVERSIONS
(FIGS. 10, 11, 12)
1. Conversion to half-wattage. (FIG. 10) The heater will produce less heat and use less
electricity if converted to half-wattage. Disconnect ONE of the two (2) black wires (with
insulated terminals) from the motor.
2. 120 VAC to 240 VAC Conversion (FIGS. 11 &
12)
(Factory-wired 120 VAC Models 120 and 124 ONLY)
These heaters can be converted to operate on 240 VAC.
1) Disconnect ONE of the two (2) black wires (with
insulated terminals) from the motor.
2) Disconnect the two (2) white wires (with insulated
terminals) from each other. Do not remove the white wire from beneath plastic wire tie.
3) Connect the black wire to the white wire. NOTE: When heater is converted from 120 VAC to
240 VAC, half-wattage conversion is not possible.
FIG. 2
FIG. 3
FIG. 4
FIG. 5
FIG. 6
FIG. 7
MEASURING
GUIDES/
GUIAS DE
MEDIDA
2
MEASURING GUIDE/GUIA
DE MEDIDA
NAIL
HERE/
CLAVE
AQUI
La tabla abajo demuestra el grado para cada modelo.
PLANIFICACION
Al instalar este calentador, siga estos pasos básicos:
Clave la caja en las vigas.
Este calentador ha sido diseñado para proporcionar
Conecte el cable de potencia.
calefacción adicional desde una pared en una con-
Fije el conjunto del calentador y la rejilla a la caja.
strucción nueva o una ya existente.
(FIG. 1)
El calentador se puede poner en funcionamiento desde una pared usando el termostato de tensión
PREPARACION
de línea Broan Modelo 86W. Adquiera los controles
1. Saque el tornillo de retención, desenchufe el conjunto
en forma separada.
de cables preconfigurado y saque de la caja el conjunto
Planifique proporcionar al calentador la tensión de
del calentador. (FIG. 2)
línea y cable de energía eléctrica apropiados.
2. Saque la cubierta de la caja. (FIG. 3)
NOTA: La energía se puede tomar de un circuito cercano, lo que dependerá del vatiaje requerido del
INSTALACION
calentador y amperaje nominal del circuito.
ADVERTENCIA: Para reducir el riesgo de incendio, no
El calentador se puede convertir a mitad de vatiaje
almacene ni use gasolina u otros vapores y líquidos
para evitar sobrecargar dichos circuitos.
flamables en las cercanías del calentador. PRECAUCIÓN: Temperatura alta, el riesgo de incendio,
MODELOS
VOLTIOS
AMPS
4.16
3.61
6.25
5.41
VATIOS
1000/500
1500 /750
2000/1000
1500/750
mantenga los cables eléctricos, cortinas, muebles y otros materiales combustibles por lo menos 3 pies (0,9 m) del frente del calentador y lejos de la cara y la parte trasera.
(VIGAS DE 40,64 CM DE CENTRO SOLAMENTE) NOTA: sitúe la caja a no menos de 15,24 cm (6 pulg.) del
piso o cualquier pared adyacente.
1. Elija cuál lado de la caja se va a montar directamente a una viga de la pared. Después, meta un soporte de montaje, desde el lado opuesto, dentro del canal en la parte superior de la caja. (FIG. 4)
El cableado viene de fábrica para las corrientes nomi-
2. Use la guía de medida que está en el lado de la caja
nales en letras oscuras. Sección “CONVERSIONES
para colocar ésta a nivel con la pared terminada. Pase
DE CABLEADO ORIGINAL” encontrará las instruc-
dos (2) clavos por los agujeros en el costado de la caja y clávelos en la viga de la pared. (FIG. 5)
ciones de vatiaje y conversión de tensión.
3. Extienda los soportes de montaje, nivele la caja, y clave a la otra viga. (FIG. 6)
La tabla abajo demuestra el grado para cada modelo.
(VIGAS DE 60,96 CM (24 PULG.) DE CENTRO)
Al instalar este calentador, siga estos pasos básicos:
1. Elija cuál lado de la caja se va a montar directamente
• Clave la caja en las vigas.
a la viga de la pared. Desde este lado, meta un soporte de montaje hasta lo más profundo que se pueda dentro
• Conecte el cable de potencia.
del canal en la parte superior de la caja.
• Fije el conjunto del calentador y la rejilla a la caja.
NOTA: sitúe la caja cuando menos 15,24 cm (6 pulg.)
(FIG. 1)
del piso y cualquier pared cercana.
2. Use la guía de medida que está en un costado de la caja para colocar ésta para que quede a nivel con la pared terminada. Pase dos (2) clavos por los agujeros en el
PREPARACION
lado de la caja y clávelos en la viga de la pared. (FIG. 7)
1. Saque el tornillo de retención, desenchufe el
3. Fije los dos (2) soportes de montaje juntos (con el tornillo que se incluye). Nivele la caja y clávela a la viga opuesta,
conjunto de cables preconfigurado y saque de
tal como se muestra.
la caja el conjunto del calentador. (FIG. 2)
2. Saque la cubierta de la caja. (FIG. 3)
CABLEANDO
(TODAS LAS INSTALACIONES)
1. Traiga el cable de energía eléctrica por la abertura del disco removible en una esquina de la caja y fije con el conector apropiado. Deje 15,24 cm (6 pulg.) de cable dentro de la caja. NOTA: use otro disco removible cuando cablee unidades en paralelo. (FIG. 8)
2. Conecte negro a negro, blanco a blanco. Use el sujetador para conexión a tierra para fijar el alambre verde o descubierto a la caja. Coloque de nuevo la cubierta de cableado. (FIG. 9)
120
124
128
120
240 208 120 240 208
240
208
8.33/4.16
12.5/6.25
6.33/4.16
7.21/3.61
1000
750
1500 112 5
BTU/HR
3413/1707
3413 2560
5120/2560
5120 3840
6827/3413 5120/2560
CONVERSIONES DE CABLEADO OPCIO- NALES (FIGS. 10, 11, 12)
1. Conversión a medio vatiaje (FIG. 10)
El calentador produce menos calor y usa menos electricidad si se convierte a medio vatiaje.
Desconecte del motor UNO de los dos (2) cables negros (que tienen terminals aisladas).
2. Conversión de 120 VCA a 240 VCA (FIGS. 11 y 12) (Solamente modelos 120 y 124 cableados de fábrica
para 120 VCA). Estos calentadores de pueden convertir para que
funcionen en 240 VCA.
1) Desconecte del motor UNO de los dos (2) cables negros (que tienen terminal aislada).
2) Desconecte los dos (2) cables blancos (con terminales aisladas). No saque el cable blanco debajo del enlace de cable plástico.
3) Conecte el cable negro al cable blanco. NOTA: cuando el calentador se convierte de 120 VCA
a 240 VCA, no es posible convertir a medio vatiaje.
INSTALLATION
WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapors and liquids in the vicinity of the heater.
CAUTION: High temperature, risk of fire, keep electrical cords, drapery, furnishings, and other combustibles at least 3 feet (0.9 m) from the front of the heater and away from the side and rear.
(16"-ON-CENTER STUDS ONLY) NOTE: Locate housing at least 6" from the floor and
any adjacent walls.
1. Choose which side of housing will be mounted di­rectly to a wall stud. Then insert a mounting bracket from the opposite side into the channel at the top of the housing. (FIG. 4)
2. Use measuring guide on side of housing to posi­tion housing so that it will be flush with finished wall. Drive to (2) nails through the holes on side of housing and into stud. (FIG. 5)
3. Extend mounting bracket, level housing, and nail to other stud. (FIG. 6)
(24"-ON-CENTER STUDS ONLY)
1. Choose which side of housing will be mounted directly to a wall stud. From this side, push a mount­ing bracket as far as possible into the channel at the top of the housing.
NOTE: Locate housing at least 6" from the floor and any adjacent walls.
2. Use measuring guide on side of housing to posi­tion housing so that it will be flush with finished wall. Drive two (2) nails through the holes in side of housing and into stud. (FIG. 7)
3. Secure the two (2) mounting brackets together (with screw supplied). Level housing and nail to opposite stud, as shown.
WIRING
(ALL INSTALLATIONS)
1. Feed electrical power cable through open knockout in corner of housing and attach with appropriate connector. Allow 6" of wire inside of housing.
NOTE: Use other housing knockout when wiring units in parallel.
2. Connect black to black, white to white, green to green or bare wire. Replace wiring cover. (FIG. 8)
OPTIONAL WIRING CONVERSIONS
(FIGS. 9, 10, 11)
1. Conversion to half-wattage. (FIG. 9) The heater will produce less heat and use less
electricity if converted to half-wattage. Disconnect ONE of the two (2) black wires (with
insulated terminals) from the motor.
2. 120 VAC to 240 VAC Conversion (FIGS. 10 &
11)
(Factory-wired 120 VAC Models 120 and 124 ONLY)
These heaters can be converted to operate on 240 VAC.
1) Disconnect ONE of the two (2) black wires (with
insulated terminals) from the motor.
2) Disconnect the two (2) white wires (with insu-
lated terminals) from each other. Do not remove the white wire from beneath plastic wire tie.
3) Connect the black wire to the white wire. NOTE: When heater is converted from 120 VAC to
240 VAC, half-wattage conversion is not possible.
FIG. 8
DISCONNECT FOR HALF-
WAT TAGE
BLACK
NEGRO
HEATING
ELEMENT
ELEMENTO
DE CALOR
FACTORY-WIRED
HEATER
(FULL WATTAGE)
CALENTADOR
CABLEADO DE
FABRICA (VATIAJE
COMPLETO)
WHITE
BLANCO
DESCONECTE PARA MEDIO
VATIAJE
BLACK
BLACK
NEGRO
NEGRO
M
WHITE
WHITE
LINE IN LINEA DE ENTRADA
BLACK
BLANCO
BLACK
BLANCO
THERMAL
OVERLOAD
SOBRECARGA
TERMICA
NEGRO
GROUND
NEGRO
TIERRA
BLACK
NEGRO
FIG. 9 - HALF-WATTAGE CONVERSION CONVERSIÓN DE MEDIO VATIAJE
(2) BLACK WIRES (connected to motor)
(2) CABLES NEGROS (conectados al motor)
MOTOR
FIG. 10 - 120VAC TO 240VAC CONVERSION CONVERSIÓN DE 120VCA A 240VCA
WHITE WIRES
CABLES BLANCOS
BLACK WIRE (from motor)
CABLE NEGRO (del motor)
MOTOR
FIG. 11
BLACK
BLACK
NEGRO
NEGRO
BLACK
BLANCO
BLACK
BLANCO
THERMAL
OVERLOAD
SOBRECARGA
TERMICA
NEGRO
GROUND
NEGRO
TIERRA
BLACK
NEGRO
BLACK
NEGRO
HEATING ELEMENT
WHITE
ELEMENTO
BLANCO
DE CALOR
WHITE
BLANCO
WHITE
BLANCO
CONVERTED 240 VAC HEATER
CALENTADOR CONVERTIDO
240 VCA
LINE IN LINEA DE ENTRADA 240VCA
M
WHITE
WHITE
INSTALACION
ADVERTENCIA: Para reducir el riesgo de incendio, no almacene ni use gasolina u otros vapores y líquidos flamables en las cercanías del calentador.
PRECAUCIÓN: Temperatura alta, el riesgo de incendio, mantenga los cables eléctricos, cortinas, muebles y otros materiales combustibles por lo menos 3 pies (0,9 m) del frente del calentador y lejos de la cara y la parte trasera.
(VIGAS DE 40,64 CM DE CENTRO SOLAMENTE) NOTA: sitúe la caja a no menos de 15,24 cm (6 pulg.) del
piso o cualquier pared adyacente.
1. Elija cuál lado de la caja se va a montar directamente a una viga de la pared. Después, meta un soporte de montaje, desde el lado opuesto, dentro del canal en la parte superior de la caja. (FIG. 4)
2. Use la guía de medida que está en el lado de la caja para colocar ésta a nivel con la pared terminada. Pase dos (2) clavos por los agujeros en el costado de la caja y clávelos en la viga de la pared. (FIG. 5)
3. Extienda los soportes de montaje, nivele la caja, y clave a la otra viga. (FIG. 6)
(VIGAS DE 60,96 CM (24 PULG.) DE CENTRO)
1. Elija cuál lado de la caja se va a montar directamente a la viga de la pared. Desde este lado, meta un soporte de montaje hasta lo más profundo que se pueda dentro del canal en la parte superior de la caja. NOTA: sitúe la caja cuando menos 15,24 cm (6 pulg.) del piso y cualquier pared cercana.
2. Use la guía de medida que está en un costado de la caja para colocar ésta para que quede a nivel con la pared terminada. Pase dos (2) clavos por los agujeros en el lado de la caja y clávelos en la viga de la pared. (FIG. 7)
3. Fije los dos (2) soportes de montaje juntos (con el tornillo que se incluye). Nivele la caja y clávela a la viga opuesta, tal como se muestra.
CABLEANDO
(TODAS LAS INSTALACIONES)
1. Traiga el cable de energía eléctrica por la abertura del disco removible en una esquina de la caja y fije con el conector apropiado. Deje 15,24 cm (6 pulg.) de cable dentro de la caja. NOTA: use otro disco removible cuando cablee unidades en paralelo.
2. Conecte negro a negro, blanco a blanco, verde a verde o a cable desnudo. Coloque de nuevo la cubierta de cableado. (FIG. 8)
CONVERSIONES DE CABLEADO OPCIO­NALES (FIGS. 9, 10, 11)
1. Conversión a medio vatiaje (FIG. 9)
El calentador produce menos calor y usa menos electricidad si se convierte a medio vatiaje.
Desconecte del motor UNO de los dos (2) cables negros (que tienen terminals aisladas).
2. Conversión de 120 VCA a 240 VCA (FIGS. 10 y 11) (Solamente modelos 120 y 124 cableados de fábrica
para 120 VCA). Estos calentadores de pueden convertir para que
funcionen en 240 VCA.
1) Desconecte del motor UNO de los dos (2) cables negros (que tienen terminal aislada).
2) Desconecte los dos (2) cables blancos (con terminales aisladas). No saque el cable blanco debajo del enlace de cable plástico.
3) Conecte el cable negro al cable blanco. NOTA: cuando el calentador se convierte de 120 VCA a
240 VCA, no es posible convertir a medio vatiaje.
3
Loading...
+ 5 hidden pages