OBJ_BUCH-2563-003.book Page 1 Thursday, June 23, 2016 11:28 AM
WEUWEU
Robert Bosch Power Tools GmbH
70538 Stuttgart
GERMANY
www.bosch-pt.com
1 609 92A 2ZU (2016.01) T / 145
Quigo Plus
de Originalbetriebsanleitung
en Original instructions
fr Notice originale
es Manual original
pt Manual original
it Istruzioni originali
nl Oorspronkelijke gebruiksaanwijzing
da Original brugsanvisning
sv Bruksanvisning i original
no Original driftsinstruks
fi Alkuperäiset ohjeet
el Πρωτότυπο οδηγιών χρήσης
tr Orijinal işletme talimatı
ar
OBJ_BUCH-2563-003.book Page 2 Thursday, June 23, 2016 11:28 AM
OBJ_BUCH-2563-003.book Page 3 Thursday, June 23, 2016 11:28 AM
| 3
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
8
7
5
4
6
OBJ_BUCH-2563-003.book Page 4 Thursday, June 23, 2016 11:28 AM
4 |
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
9
90°
B
A
OBJ_BUCH-2563-003.book Page 5 Thursday, June 23, 2016 11:28 AM
| 5
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
10
9
2 607 990 031
3
OBJ_BUCH-2563-003.book Page 6 Thursday, June 23, 2016 11:28 AM
6 |
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 7 Thursday, June 23, 2016 11:28 AM
Deutsch | 7
Deutsch
Sicherheitshinweise
Sämtliche Anweisungen sind zu lesen und zu beachten, um
mit dem Messwerkzeug gefahrlos und sicher zu arbeiten.
Wenn das Messwerkzeug nicht entsprechend den vorliegenden Anweisungen verwendet wird, können die integrierten
Schutzvorkehrungen im Messwerkzeug beeinträchtigt werden. Machen Sie Warnschilder am Messwerkzeug niemals
unkenntlich. BEWAHREN SIE DIESE ANWEISUNGEN GUT AUF
UND GEBEN SIE SIE BEI WEITERGABE DES MESSWERKZEUGS MIT.
Vorsicht – wenn andere als die hier angegebenen Bedienungs- oder
Justiereinrichtungen benutzt oder andere Verfahrensweisen ausgeführt
werden, kann dies zu gefährlicher Strahlungsexposition führen.
Das Messwerkzeug wird mit einem Warnschild ausgeliefert (in der
Darstellung des Messwerkzeugs auf der Grafikseite mit Nummer 7
gekennzeichnet).
Ist der Text des Warnschildes nicht in Ihrer Landessprache, dann über-
kleben Sie ihn vor der ersten Inbetriebnahme mit dem mitgelieferten
Aufkleber in Ihrer Landessprache.
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
OBJ_BUCH-2563-003.book Page 8 Thursday, June 23, 2016 11:28 AM
8 | Deutsch
Richten Sie den Laserstrahl nicht auf Personen oder Tiere
und blicken Sie nicht selbst in den direkten oder reflektierten Laserstrahl. Dadurch können Sie Personen blenden, Un-
fälle verursachen oder das Auge schädigen.
Falls Laserstrahlung ins Auge trifft, sind die Augen bewusst zu schließen
und der Kopf sofort aus dem Strahl zu bewegen.
Nehmen Sie keine Änderungen an der Lasereinrichtung vor.
Verwenden Sie die Laser-Sichtbrille nicht als Schutzbrille. Die Laser-
Sichtbrille dient zum besseren Erkennen des Laserstrahls, sie schützt jedoch
nicht vor der Laserstrahlung.
Verwenden Sie die Laser-Sichtbrille nicht als Sonnenbrille oder im Stra-
ßenverkehr. Die Laser-Sichtbrille bietet keinen vollständigen UV-Schutz und
vermindert die Farbwahrnehmung.
Lassen Sie das Messwerkzeug von qualifiziertem Fachpersonal und nur
mit Original-Ersatzteilen reparieren. Damit wird sichergestellt, dass die
Sicherheit des Messwerkzeuges erhalten bleibt.
Lassen Sie Kinder das Laser-Messwerkzeug nicht unbeaufsichtigt benut-
zen. Sie könnten unbeabsichtigt Personen blenden.
Arbeiten Sie mit dem Messwerkzeug nicht in explosionsgefährdeter Um-
gebung, in der sich brennbare Flüssigkeiten, Gase oder Stäube befinden.
Im Messwerkzeug können Funken erzeugt werden, die den Staub oder die
Dämpfe entzünden.
Bringen Sie das Messwerkzeug nicht in die Nähe von Herzschrittmachern. Durch den Magnet im Inneren des Messwerk-
zeugs wird ein Feld erzeugt, das die Funktion von Herzschrittmachern beeinträchtigen kann.
Halten Sie das Messwerkzeug fern von magnetischen Datenträgern und
magnetisch empfindlichen Geräten. Durch die Wirkung des Magnets kann
es zu irreversiblen Datenverlusten kommen.
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 9 Thursday, June 23, 2016 11:28 AM
Deutsch | 9
Produkt- und Leistungsbeschreibung
Bestimmungsgemäßer Gebrauch
Das Messwerkzeug ist bestimmt zum Ermitteln und Überprüfen von waagrechten und senkrechten Linien.
Das Messwerkzeug ist ausschließlich für den Betrieb an geschlossenen Einsatzorten geeignet.
Abgebildete Komponenten
Die Nummerierung der abgebildeten Komponenten bezieht sich auf die Darstellung des Messwerkzeugs auf der Grafikseite.
1) Der Arbeitsbereich kann durch ungünstige Umgebungsbedingungen (z.B. direkte
Sonneneinstrahlung) verringert werden.
Zur eindeutigen Identifizierung Ihres Messwerkzeugs dient die Seriennummer 8 auf dem
Typenschild.
3 603 F63 6..
±0,8 mm/m
±1,0 mm/m
+5 °C ...+ 40 ° C
–20 ° C... +70 °C
635 nm, <1 mW
0,5 mrad (Vollwinkel)
2x1,5VLR3(AAA)
7m
±4°
6s
90 %
2
1
1/4"
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 11 Thursday, June 23, 2016 11:28 AM
Deutsch | 11
KreuzlinienlaserQuigo Plus
Betriebsdauer ca.
Gewicht entsprechend EPTA-Procedure 01:2014
Maße (Länge x Breite x Höhe)
1) Der Arbeitsbereich kann durch ungünstige Umgebungsbedingungen (z.B. direkte
Sonneneinstrahlung) verringert werden.
Zur eindeutigen Identifizierung Ihres Messwerkzeugs dient die Seriennummer 8 auf dem
Typenschild.
65x65x65mm
>5h
0,27 kg
Montage
Batterien einsetzen/wechseln
Für den Betrieb des Messwerkzeugs wird die Verwendung von Alkali-ManganBatterien empfohlen.
Zum Öffnen des Batteriefachdeckels 6 drücken Sie die Arretierung 4 in Pfeilrichtung und nehmen den Batteriefachdeckel ab. Setzen Sie die mitgelieferten Batterien ein. Achten Sie dabei auf die richtige Polung entsprechend der Darstellung im Batteriefach.
Werden die Batterien schwach, dann blinken die Laserlinien für einige Sekunden
in schnellem Takt.
Ersetzen Sie immer alle Batterien gleichzeitig. Verwenden Sie nur Batterien
eines Herstellers und mit gleicher Kapazität.
Nehmen Sie die Batterien aus dem Messwerkzeug, wenn Sie es längere
Zeit nicht benutzen. Die Batterien können bei längerer Lagerung korrodie-
ren und sich selbst entladen.
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
OBJ_BUCH-2563-003.book Page 12 Thursday, June 23, 2016 11:28 AM
12 | Deutsch
Betrieb
Inbetriebnahme
Schützen Sie das Messwerkzeug vor Nässe und direkter Sonneneinstrah-
lung.
Setzen Sie das Messwerkzeug keinen extremen Temperaturen oder Tem-
peraturschwankungen aus. Lassen Sie es z.B. nicht längere Zeit im Auto lie-
gen. Lassen Sie das Messwerkzeug bei größeren Temperaturschwankungen
erst austemperieren, bevor Sie es in Betrieb nehmen. Bei extremen Temperaturen oder Temperaturschwankungen kann die Präzision des Messwerkzeugs
beeinträchtigt werden.
Vermeiden Sie heftige Stöße oder Stürze des Messwerkzeugs. Durch Be-
schädigungen des Messwerkzeugs kann die Genauigkeit beeinträchtigt werden. Vergleichen Sie nach einem heftigen Stoß oder Sturz die Laserlinie zur
Kontrolle mit einer bekannten waagrechten oder senkrechten Referenzlinie.
Schalten Sie das Messwerkzeug aus, wenn Sie es transportieren. Beim
Ausschalten wird die Pendeleinheit verriegelt, die sonst bei starken Bewegungen beschädigt werden kann.
Ein-/Ausschalten
Zum Einschalten des Messwerkzeugs schieben Sie den Ein-/Ausschalter 1 nach
oben. Das Messwerkzeug sendet sofort nach dem Einschalten zwei Laserlinien
aus der Austrittsöffnung 2.
Richten Sie den Laserstrahl nicht auf Personen oder Tiere und blicken
Sie nicht selbst in den Laserstrahl, auch nicht aus größerer Entfernung.
Zum Ausschalten des Messwerkzeugs schieben Sie den Ein-/Ausschalter 1
nach unten über die Laser-Austrittsöffnung 2. Beim Ausschalten wird die Pendeleinheit verriegelt.
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 13 Thursday, June 23, 2016 11:28 AM
Deutsch | 13
Lassen Sie das eingeschaltete Messwerkzeug nicht unbeaufsichtigt und
schalten Sie das Messwerkzeug nach Gebrauch ab. Andere Personen
könnten vom Laserstrahl geblendet werden.
Wenn Sie das Messwerkzeug nicht benutzen, schalten Sie es aus, um Energie zu
sparen.
Nivellierautomatik
Um mit Nivellierautomatik zu arbeiten, stellen Sie das Messwerkzeug auf eine
waagrechte, feste Unterlage oder befestigen Sie es auf dem Stativ 3.
Nach dem Einschalten gleicht die Nivellierautomatik Unebenheiten innerhalb
des Selbstnivellierbereiches von ±4 ° automatisch aus. Die Nivellierung ist abgeschlossen, sobald die Laserlinien nicht mehr blinken.
Ist die automatische Nivellierung nicht möglich, z.B. weil die Unterseite des
Messwerkzeugs mehr als 4° von der Waag rechten abweicht oder das Messwerkzeug frei in der Hand gehalten wird, dann blinken die Laserlinien dauerhaft in
langsamem Takt und das Messwerkzeug arbeitet ohne Nivellierautomatik. Die
Laserlinien bleiben eingeschaltet, die beiden gekreuzten Linien verlaufen aber
nicht mehr zwingend im rechten Winkel zueinander.
Um wieder mit Nivellierautomatik zu arbeiten, positionieren Sie das Messwerkzeug so, dass die Unterseite waagrecht ausgerichtet ist, und warten die Selbstnivellierung ab. Sobald sich das Messwerkzeug innerhalb des Selbstnivellierbereiches von ±4 ° befindet und einnivelliert ist, leuchten die Laserlinien wieder
dauerhaft.
Bei Erschütterungen oder Lageänderungen während des Betriebs wird das
Messwerkzeug automatisch wieder einnivelliert. Überprüfen Sie nach einer
erneuten Nivellierung die Position der waagrechten bzw. senkrechten Laserlinie
in Bezug auf Referenzpunkte, um Fehler zu vermeiden.
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
OBJ_BUCH-2563-003.book Page 14 Thursday, June 23, 2016 11:28 AM
14 | Deutsch
Arbeitshinweise
Verwenden Sie immer nur die Mitte der Laserlinie zum Markieren. Die
Breite der Laserlinie ändert sich mit der Entfernung.
Arbeiten mit den Markierungen auf den Laserlinien (siehe Bilder A– B)
Auf den Laserlinien werden in gleichen Abständen Markierungen angezeigt, die
als Orientierungshilfe dienen können. Die Abstände der Markierungen sind nur
gleich, wenn das Messwerkzeug senkrecht zur Wand ausgerichtet ist. Den 90°Winkel können Sie mithilfe der Laser-Zieltafel 9 kontrollieren.
Stellen Sie das Messwerkzeug an der gewünschten Stelle auf, schalten Sie es ein
und lassen Sie es einnivellieren. Stellen Sie die Laser-Zieltafel 9 mit der Rückseite
an die Wand. Richten Sie das Messwerkzeug so aus, dass die senkrechte Laserlinie
durch die obere und die untere rote Markierung auf der Laser-Zieltafel verläuft.
Die Abstände der Markierungen untereinander sind von der Entfernung des
Messwerkzeugs zur Wand abhängig. Kontrollieren Sie den 90°-Winkel erneut,
wenn Sie die Entfernung verändern.
Arbeiten mit dem Stativ
Ein Stativ bietet eine stabile, höheneinstellbare Messunterlage. Setzen Sie das
Messwerkzeug mit der Stativaufnahme 5 auf das 1/4"-Gewinde des Stativs auf
und schrauben Sie es mit der Feststellschraube des Stativs fest.
Richten Sie das Stativ grob aus, bevor Sie das Messwerkzeug einschalten.
Laser-Sichtbrille (Zubehör)
Die Laser-Sichtbrille filtert das Umgebungslicht aus. Dadurch erscheint das rote
Licht des Lasers für das Auge heller.
Verwenden Sie die Laser-Sichtbrille nicht als Schutzbrille. Die Laser-
Sichtbrille dient zum besseren Erkennen des Laserstrahls, sie schützt jedoch
nicht vor der Laserstrahlung.
Verwenden Sie die Laser-Sichtbrille nicht als Sonnenbrille oder im
Straßenverkehr. Die Laser-Sichtbrille bietet keinen vollständigen UV-Schutz
und vermindert die Farbwahrnehmung.
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 15 Thursday, June 23, 2016 11:28 AM
Deutsch | 15
Wartung und Service
Wartung und Reinigung
Halten Sie das Messwerkzeug stets sauber.
Tauchen Sie das Messwerkzeug nicht ins Wasser oder andere Flüssigkeiten.
Wischen Sie Verschmutzungen mit einem feuchten, weichen Tuch ab. Verwen-
den Sie keine Reinigungs- oder Lösemittel.
Reinigen Sie insbesondere die Flächen an der Austrittsöffnung des Lasers regel-
mäßig und achten Sie dabei auf Fusseln.
Kundendienst und Anwendungsberatung
Der Kundendienst beantwortet Ihre Fragen zu Reparatur und Wartung Ihres
Produkts sowie zu Ersatzteilen. Explosionszeichnungen und Informationen zu
Ersatzteilen finden Sie auch unter:
www.bosch-pt.com
Das Bosch-Anwendungsberatungs-Team hilft Ihnen gerne bei Fragen zu unseren
Produkten und deren Zubehör.
www.bosch-do-it.de, das Internetportal für Heimwerker und Gartenfreunde.
www.1-2-do.com
In der Heimwerker-Community 1-2-do.com können Sie Produkttester werden,
Ideen sammeln oder sich mit anderen Heimwerkern austauschen.
www.diy-academy.eu, das komplette Service-Angebot der DIY Academy.
Geben Sie bei allen Rückfragen und Ersatzteilbestellungen bitte unbedingt die
10-stellige Sachnummer laut Typenschild des Produkts an.
Deutschland
Robert Bosch Power Tools GmbH
Servicezentrum Elektrowerkzeuge
Zur Luhne 2
37589 Kalefeld – Willershausen
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
OBJ_BUCH-2563-003.book Page 16 Thursday, June 23, 2016 11:28 AM
16 | Deutsch
Unter www.bosch-pt.de können Sie online Ersatzteile bestellen oder Reparaturen anmelden.
Kundendienst: Tel.: (0711) 40040480
Fax: (0711) 40040481
E-Mail: Servicezentrum.Elektrowerkzeuge@de.bosch.com
Anwendungsberatung: Tel.: (0711) 40040480
Fax: (0711) 40040482
E-Mail: kundenberatung.ew@de.bosch.com
Österreich
Unter www.bosch-pt.at können Sie online Ersatzteile bestellen.
Tel.: (01) 797222010
Fax: (01) 797222011
E-Mail: service.elektrowerkzeuge@at.bosch.com
Schweiz
Unter www.bosch-pt.com/ch/de können Sie online Ersatzteile bestellen.
Tel.: (044) 8471511
Fax: (044) 8471551
E-Mail: Aftersales.Service@de.bosch.com
Messwerkzeuge, Zubehör und Verpackungen sollen einer umweltgerechten
Wiederverwertung zugeführt werden.
Werfen Sie Messwerkzeuge und Akkus/Batterien nicht in den Hausmüll!
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 17 Thursday, June 23, 2016 11:28 AM
English | 17
Nur für EU-Länder:
Gemäß der europäischen Richtlinie 2012/19/EU müssen nicht
mehr gebrauchsfähige Messwerkzeuge und gemäß der europäischen Richtlinie 2006/66/EG müssen defekte oder
verbrauchte Akkus/Batterien getrennt gesammelt und einer
umweltgerechten Wiederverwendung zugeführt werden.
Nicht mehr gebrauchsfähige Akkus/Batterien können direkt abgegeben werden
bei:
All instructions must be read and observed in order to work
safely with the measuring tool. The integrated protections in
the measuring tool may be compromised if the measuring tool
is not used in accordance with the instructions provided.
Never make warning signs on the measuring tool unrecognisable. STORE THESE INSTRUCTIONS IN A SAFE PLACE AND
INCLUDE THEM WITH THE MEASURING TOOL WHEN GIVING
IT TO A THIRD PARTY.
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
OBJ_BUCH-2563-003.book Page 18 Thursday, June 23, 2016 11:28 AM
18 | English
Caution – The use of other operating or adjusting equipment or the appli-
cation of other processing methods than those mentioned here can lead
to dangerous radiation exposure.
The measuring tool is provided with a warning label (marked with num-
ber 7 in the representation of the measuring tool on the graphics page).
If the text of the warning label is not in your national language, stick the
provided warning label in your national language over it before operating for the first time.
Do not direct the laser beam at persons or animals and do
not stare into the direct or reflected laser beam yourself,
not even from a distance. You could blind somebody, cause
accidents or damage your eyes.
If laser radiation strikes your eye, you must deliberately close your eyes
and immediately turn your head away from the beam.
Do not make any modifications to the laser equipment.
Do not use the laser viewing glasses as safety goggles. The laser viewing
glasses are used for improved visualisation of the laser beam, but they do not
protect against laser radiation.
Do not use the laser viewing glasses as sun glasses or in traffic. The laser
viewing glasses do not afford complete UV protection and reduce colour perception.
Have the measuring tool repaired only through qualified specialists us-
ing original spare parts. This ensures that the safety of the measuring tool is
maintained.
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 19 Thursday, June 23, 2016 11:28 AM
English | 19
Do not allow children to use the laser measuring tool without supervi-
sion. They could unintentionally blind other persons or themselves.
Do not operate the measuring tool in explosive environments, such as in
the presence of flammable liquids, gases or dusts. Sparks can be created
in the measuring tool which may ignite the dust or fumes.
Keep the measuring tool away from cardiac pacemakers. The
magnet inside the measuring tool generates a field that can impair
the function of cardiac pacemakers.
Keep the measuring tool away from magnetic data media and magneti-
cally-sensitive equipment. The effect of the magnet can lead to irreversible
data loss.
Product Description and Specifications
Intended Use
The measuring tool is intended for determining and checking horizontal and vertical lines.
The measuring tool is suitable exclusively for operation in enclosed working sites.
Product Features
The numbering of the product features shown refers to the illustration of the
measuring tool on the graphic page.
1 On/Off switch
2 Exit opening for laser beam
3 Tripod
4 Latch of battery lid
5 Tripod mount 1/4"
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
OBJ_BUCH-2563-003.book Page 20 Thursday, June 23, 2016 11:28 AM
20 | English
6 Battery lid
7 Laser warning label
8 Serial number
9 Laser target plate
10 Laser viewing glasses*
* The accessories illustrated or described are not included as standard delivery.
Technical Data
Cross-line LaserQuigo Plus
Article number
Working range, min.
1)
Levelling Accuracy
–at0°
– at±4°
Self-levelling range, typically
Levelling duration, typically
Operating temperature
Storage temperature
Relative air humidity, max.
Laser class
Laser type
1) The working range can be decreased by unfavourable environmental conditions (e. g. direct
sun irradiation).
The measuring tool can be clearly identified with the serial number 8 on the type plate.
3 603 F63 6..
±0.8 mm/m
±1.0 mm/m
+5 °C ...+ 40 ° C
–20 ° C... +70 °C
635 nm, <1 mW
7m
±4°
6s
90 %
2
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 21 Thursday, June 23, 2016 11:28 AM
English | 21
Cross-line LaserQuigo Plus
C
6
Divergence
–Laser line
0.5 mrad (full angle)
Tripod mount
Batteries
Operating time, approx.
Weight according to EPTA-Procedure 01:2014
Dimensions (length x width x height)
1) The working range can be decreased by unfavourable environmental conditions (e. g. direct
sun irradiation).
The measuring tool can be clearly identified with the serial number 8 on the type plate.
2x1.5VLR3(AAA)
>5h
0.27 kg
65x65x65mm
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the measuring tool.
To open the battery lid 6, press the latch 4 in the direction of the arrow and remove
the battery lid. Insert the batteries provided. Pay attention to the correct polarity
of the batteries according to the representation in the battery compartment.
If the batteries become weak, the laser lines will flash quickly for a few seconds.
Always replace all batteries at the same time. Only use batteries from one brand
and with the identical capacity.
Remove the batteries from the measuring tool when not using it for
extended periods. When storing for extended periods, the batteries can
corrode and self-discharge.
1
1/4"
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
OBJ_BUCH-2563-003.book Page 22 Thursday, June 23, 2016 11:28 AM
22 | English
Operation
Initial Operation
Protect the measuring tool against moisture and direct sun light.
Do not subject the measuring tool to extreme temperatures or variations
in temperature. As an example, do not leave it in vehicles for a long time. In
case of large variations in temperature, allow the measuring tool to adjust to
the ambient temperature before putting it into operation. In case of extreme
temperatures or variations in temperature, the accuracy of the measuring
tool can be impaired.
Avoid heavy impact to or falling down of the measuring tool. Damage to
the measuring tool can impair its accuracy. After heavy impact or shock, compare the laser line with a known horizontal or vertical reference line.
Switch the measuring tool off during transport. When switching off, the
levelling unit, which can be damaged in case of intense movement, is locked.
Switching On and Off
To switch on the measuring tool, push the On/Off switch 1 upward. Immediately
after switching on, the measuring tool sends two laser beams out of the exit
opening 2.
Do not point the laser beam at persons or animals and do not look into the
laser beam yourself, not even from a large distance.
To switch off the measuring tool, push the On/Off switch 1 downward over the
laser beam exit opening 2. When switching off, the levelling unit is locked.
Do not leave the switched-on measuring tool unattended and switch the
measuring tool off after use. Other persons could be blinded by the laser
beam.
When not using the measuring tool, switch it off in order to extend the battery
life.
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 23 Thursday, June 23, 2016 11:28 AM
English | 23
Automatic Levelling
To work with automatic levelling, place the measuring tool on a level, firm support or fasten it to the tripod 3.
After switching on, the automatic levelling function automatically compensates
irregularities within the self-levelling range of ±4 °. The levelling is finished as
soon as the laser lines do not flash anymore.
If automatic levelling is not possible, e.g. because the underside of the measuring
tool deviates by more than 4° from the horizontal plane or the measuring tool is
held freely in the hand, the laser lines will continuously flash slowly and the measuring tool will work without automatic levelling. The laser lines remain switched on,
but the two crossed lines will no longer necessarily be at a right angle to each other.
To work with automatic levelling again, position the measuring tool so that the
underside is aligned horizontally and wait for the self-levelling to be performed.
As soon as the measuring tool is within the self-levelling range of ± 4° and is levelled in, the laser lines will light up continuously again.
In case of ground vibrations or position changes during operation, the measuring
tool is automatically levelled in again. To avoid errors, check the position of the horizontal and vertical laser line with regard to the reference points upon re-levelling.
Working Advice
Always use the centre of the laser line for marking. The width of the laser
line changes with the distance.
Working with the Markings on the Laser Lines (see figures A– B)
Markings are displayed at equal intervals on the laser lines , whic h can be use d to
assist with orientation. The intervals between the markings are equal only when
the measuring tool is aligned perpendicular to the wall. You can check the 90°
angle using the laser target plate 9.
Place the measuring tool in the required position, switch it on and allow it to level
in. Place the laser target plate 9 with its back against the wall. Align the measur-
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
OBJ_BUCH-2563-003.book Page 24 Thursday, June 23, 2016 11:28 AM
24 | English
ing tool so that the vertical laser line runs through the upper and lower red marking on the laser target plate.
The intervals between the markings are dependent on the distance of the measuring tool to the wall. Check the 90° angle again if you change the distance.
Working with the Tripod
A tripod offers a stable, height-adjustable measuring support. Place the measuring tool via the tripod mount 5 onto the 1/4" male thread of the tripod and screw
the locking screw of the tripod tight.
Adjust the tripod roughly before switching on the measuring tool.
Laser Viewing Glasses (Accessory)
The laser viewing glasses filter out the ambient light. This makes the red light of
the laser appear brighter for the eyes.
Do not use the laser viewing glasses as safety goggles. The laser viewing
glasses are used for improved visualisation of the laser beam, but they do not
protect against laser radiation.
Do not use the laser viewing glasses as sun glasses or in traffic. The laser
viewing glasses do not afford complete UV protection and reduce colour perception.
Maintenance and Service
Maintenance and Cleaning
Keep the measuring tool clean at all times.
Do not immerse the measuring tool in water or other fluids.
Wipe off debris using a moist and soft cloth. Do not use any cleaning agents or
solvents.
Regularly clean the surfaces at the exit opening of the laser in particular, and pay
attention to any fluff or fibres.
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 25 Thursday, June 23, 2016 11:28 AM
English | 25
After-sales Service and Application Service
Our after-sales service responds to your questions concerning maintenance and
repair of your product as well as spare parts. Exploded views and information on
spare parts can also be found under:
www.bosch-pt.com
Bosch’s application service team will gladly answer questions concerning our
products and their accessories.
In all correspondence and spare parts orders, please always include the 10-digit
article number given on the nameplate of the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange the collection of a
product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: boschservicecentre@bosch.com
Ireland
Origo Ltd.
Unit 23 Magna Drive
Magna Business Park
City West
Dublin 24
Tel. Service: (01) 4666700
Fax: (01) 4666888
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
OBJ_BUCH-2563-003.book Page 26 Thursday, June 23, 2016 11:28 AM
26 | English
Australia, New Zealand and Pacific Islands
Robert Bosch Australia Pty. Ltd.
Power Tools
Locked Bag 66
Clayton South VIC 3169
Customer Contact Center
Inside Australia:
Phone: (01300) 307044
Fax: (01300) 307045
Inside New Zealand:
Phone: (0800) 543353
Fax: (0800) 428570
Outside AU and NZ:
Phone: +61 3 95415555
www.bosch.com.au
Republic of South Africa
Customer service
Hotline: (011) 6519600
Gauteng – BSC Service Centre
35 Roper Street, New Centre
Johannesburg
Tel.: (011) 4939375
Fax: (011) 4930126
E-Mail: bsctools@icon.co.za
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 27 Thursday, June 23, 2016 11:28 AM
English | 27
KZN – BSC Service Centre
Unit E, Almar Centre
143 Crompton Street
Pinetown
Tel.: (031) 7012120
Fax: (031) 7012446
E-Mail: bsc.dur@za.bosch.com
OBJ_BUCH-2563-003.book Page 28 Thursday, June 23, 2016 11:28 AM
28 | English
Disposal
Measuring tools, accessories and packaging should be sorted for environmentalfriendly recycling.
Do not dispose of measuring tools and batteries/rechargeable batteries into
household waste!
Only for EC countries:
According to the European Guideline 2012/19/EU, measuring
tools that are no longer usable, and according to the European
Guideline 2006/66/EC, defective or used battery packs/batteries, must be collected separately and disposed of in an environmentally correct manner.
Batteries no longer suitable for use can be directly returned at:
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange the collection of a
product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: boschservicecentre@bosch.com
Subject to change without notice.
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
OBJ_BUCH-2563-003.book Page 29 Thursday, June 23, 2016 11:28 AM
Français | 29
Français
Avertissements de sécurité
Pour une utilisation sans danger et en toute sécurité de l’appareil de mesure, lisez attentivement toutes les instructions
et tenez-en compte. Si l’appareil de mesure n’est pas utilisé
conformément aux présentes instructions, les dispositifs de
endommagés. Faites en sorte que les étiquettes d’avertissement se trouvant sur l’appareil de mesure restent toujours lisibles. CONSERVEZ CES
INSTRUCTIONS DANS UN LIEU SÛR ET REMETTEZ-LES À TOUT NOUVEL
UTILISATEUR DE L’APPAREIL DE MESURE.
Attention – si d’autres dispositifs d’utilisation ou d’ajustage que ceux in-
diqués ici sont utilisés ou si d’autres procédés sont appliqués, ceci peut
entraîner une exposition dangereuse au rayonnement.
Cet appareil de mesure est fourni avec une plaque d’avertissement (dans
la re prése ntati on de l’ appare il de m esure se trou vant s ur la pa ge des graphiques elle est marquée du numéro 7).
Avant la première mise en service, recouvrir le texte de la plaque d’aver-
tissement par l’autocollant fourni dans votre langue.
protection intégrés dans l’appareil sont susceptibles d’être
Bosch Power Tools1 609 92A 2ZU | (23.6.16)
OBJ_BUCH-2563-003.book Page 30 Thursday, June 23, 2016 11:28 AM
30 | Français
Ne pas diriger le faisceau laser vers des personnes ou des
animaux et ne jamais regarder soi-même dans le faisceau
laser. Vous risquez sinon d’éblouir des personnes, de causer
des accidents ou de blesser les yeux.
Au cas où le faisceau laser frappe un œil, fermez immédiatement les yeux
et dé placez la tête p our l’é loigner du fais ceau. N e jamais apport er de mo difications au dispositif laser.
Ne jamais apporter de modifications au dispositif laser.
Ne pas utiliser les lunettes de vision du faisceau laser en tant que lunettes
de protection. Les lunettes de vision du faisceau laser servent à mieux visualiser le faisceau laser, elles ne protègent cependant pas du rayonnement laser.
Ne pas utiliser les lunettes de vision du faisceau laser en tant que lu-
nettes de soleil ou en circulation routière. Les lunettes de vision du fais-
ceau laser ne protègent pas parfaitement contre les rayons ultra-violets et réduisent la perception des couleurs.
Ne faire réparer l’appareil de mesure que par une personne qualifiée et
seulement avec des pièces de rechange d’origine. Ceci permet d’assurer la
sécurité de l’appareil de mesure.
Ne pas laisser les enfants utiliser l’appareil de mesure laser sans surveil-
lance. Ils risqueraient d’éblouir d’autres personnes par mégarde.
Ne pas faire fonctionner les appareils de mesure en atmosphère explo-
sive, par exemple en présence de liquides inflammables, de gaz ou de
poussières. L’appareil de mesure produit des étincelles qui peuvent enflam-
mer les poussières ou les vapeurs.
Ne pas mettre l’appareil de mesure à proximité de stimulateurs cardiaques. L’aimant génère un champ magnétique à l’inté-
rieur de l’appareil de mesure qui peut entraver le fonctionnement
des stimulateurs cardiaques.
1 609 92A 2ZU | (23.6.16)Bosch Power Tools
Loading...
+ 114 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.