OMNEO module |
3
english
deutsch
русский
Table of contents 4
Inhaltsverzeichnis 10
Содержание 15
17-Jun-2015 | 03 | F01U308252

en | Short information OMNEO module
4
1
Short information
The OM-1 is a compact interface module which enables the
connection of a DYNACORD P 64 or Electro-Voice N8000 to an
OMNEO network. In addition, the OM-1 is able to send and
receive Dante audio to and from other Dante equipment.
OMNEO is a network technology for multi-channel transmission
of digital audio data and control data via Ethernet. The
transmission of up to 32 digital audio input signals and 32
digital audio output signals with low latency (typically 1 ms) is
possible with the OM-1.
Further OM-1 features are:
– Gigabit Ethernet Interface - 1000 MBit/s full-duplex
Ethernet Interface, IEEE 802.3u compatible
– Secondary Gigabit Ethernet Interface - Second Ethernet
Interface for the connection of a redundant network to
establish fault-tolerant systems
– Status LEDs - Link, Activity and Gigabit active status
indication for each Ethernet interface
Dante is a registered trademark of Audinate, Inc.
Parts included
Quantity Component
1 Interface module
1 Interconnection cord internal (190 mm)
1 Interconnection cord internal (65 mm)
17-Jun-2015 | 03 | F01U308252

OMNEO module Short information | en
Quantity Component
4 Torx screw M3✕6
1 Installation note
TORX is a registered trademarks of Acument Intellectual Properties, LLC.
5
17-Jun-2015 | 03 | F01U308252

en | Installation OMNEO module
6
2
Installation
1. Turn off the power of the unit and pull the mains plug
2. Remove the cover plate (6 screws on the sides, 3 screws on
top, 4 screws on the rear)
3. Remove the blind on the rear panel (2 screws)
4. Install the OM-1 module (see picture); first, secure it with 2
screws on the rear panel Ⓐ, then with 2 screws on the bolt
Ⓑ, tighten the screws
5. Make the following cable connections: Left connector on
OM-1 module with CN28 on main board 80500 (65 mm flat
wire cable) Ⓒ. Right connector on OM-1 module with CN5
on DSP-Board 80496 (190 mm flat wire cable) Ⓓ.
6. Re-install the cover plate
7. Plug in the mains cord and turn the unit’s power on
8. Configure OM-1 module parameter in IRIS-Net according to
application needs