Blue Line Gen2
PIR Motion Detector
ISC-BPR2-W12
en Installation Guide
Optional Brackets:
B328, B338, B335
2,2 m - 2,75 m
(7.5 ft - 9 ft)
Recommended:
2,2 m (7.5 ft)
NOTE:
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
UL/C-UL
Perform Walk Test at least once a year.
Use only a Listed limited-power source.
The Listed control unit or a Listed burglary power supply must provide 4
hours (40 mAh) of standby power.
Install the unit in accordance with National Electrical Code NFPA 70 and
Part 1 of the Canadian Electrical code CSA
För svensk installationsanvisning se www.boschsecurity.se.
C22.1.
EN 50131-2-2 Grade 2
EN 50130-5 Environmental Class II
IP30 IK04 (EN 60529, EN 50102)
Ligue todas as cablagens apenas a um circuito de
segurança de tensão extra baixa (SELV).
Alle Drähte sind ohne Ausnahme an
Niederspannung anzuschließen.
SELV
Connect all wiring to a safety extra-low voltage (SELV)
circuit only.
INCERT B-509-0051/b
Certifi cat NF A2P 2620200001
2 boucliers NF324 - H58
Autosurveillance à l’ouverture
Immunité champ magnétique
Testé sans masque de vision verticale
www.afnor.org
www.cnpp.com
Sluit alle bedrading uitsluitend aan op een
circuit met een extra lage veiligheidsspanning.
Prenez soin de connecter tous les câbles à un
circuit à très basse tension de sécurité (TBTS).
Collegare tutti i cavi esclusivamente a un circuito
SELV (circuito di sicurezza a bassissima tensione).
Conecte el cableado únicamente a un circuito
de seguridad para voltajes muy bajos (SELV).
Changes or modifi cations not expressly approved
by Bosch Security Systems, Inc. can void the
user’s authority to operate the equipment.
-30°C to +55°C
(-20°F to +130°F )
UL Listed installations,
the temperature
range is 0°C to +49°C
(+32°F to +120°F)
0 - 95% Relative Humidity
(0 - 85% UL/C-UL installations)
Pour les installations
certifi ées NFA2P,
Température de
fonctionnement
-10°C à +55°C
1 2 3
4
1
2
© 2011 Bosch Security Systems, Inc. F.01U.139.797 | 05 | 2011.6 | 1
-
5 6
+
-
+
TTNC NC-+
9 - 15 VDC
10 mA (0.12W) @ 12 VDC
9-15 Vcc
de 5 à 7 mA @ 12 Vcc en veille/
en alarme, source limitée en
puissance, ondulation
résiduelle 1 V.
7
44 mm
(1.7 in)
≤ 100 mA, 25 VDC, 2.5 W
<20 Ω closed
8 9
2 min
105 mm
(4.2 in)
61 mm
(2.4 in)