Intrusion Alarm Systems | Blue Line Gen2 TriTech Motion Detectors
Blue Line Gen2 TriTech Motion Detectors
www.boschsecurity.com
u Pet‑friendly Selectable model available – optimize
installation for pet (45 kg [100 lb]) and non‑pet
applications
u Dynamic Temperature Compensation – superior
catch performance in any environment
The Blue Line Gen2 TriTech Motion Detectors (ISCBDL2) use a combination of passive infrared (PIR) and
microwave detection technologies with advanced
signal processing. The pet‑friendly (‑WP) models
generate alarms for human intruders without
generating false alarms for pets. These small
unobtrusive detectors are simple to install and do not
need field adjustments.
Functions
First Step Processing (FSP)
First Step Processing (FSP) almost instantly responds
to human targets without producing false alarms from
other sources. FSP adjusts the detector's sensitivity
based on signal amplitude, polarity, slope, and timing.
This eliminates the need for the installer to select the
sensitivity level, thus improving ease of installation and
reliability.
Pet‑friendly Selectivity (‑WP models only)
The installer can turn pet immunity on or off based
upon application requirements. When pet immunity is
turned off, the detector provides superior catch
performance identical to the non‑pet models. When
pet immunity is turned on, the detector can
u Microwave Noise Adaptive processing – reduce false
alarms from repetitive sources
u Wall to Wall Coverage – superior catch performance
u Flexible Mounting Height, No Adjustments – reduce
installation time and false alarms, improve catch
performance
distinguish between signals caused by humans and
signals caused by pets. It ignores signals caused by
one or two pets up to 45 kg (100 lb) or numerous
rodents.
Microwave Noise Adaptive Processing
Microwave Noise Adaptive Processing adjusts to
background disturbances, reducing false alarms
without sacrificing intruder detection.
Dynamic Temperature Compensation
The detector intelligently adjusts its sensitivity so that
it can identify human intruders at virtually any
temperature.
Wall-to-Wall Coverage
An improved lookdown zone and coverage range of
12 m x 12 m (40 ft x 40 ft) provide wall-to-wall
coverage.
Self-locking Enclosure
The sliding self‑locking enclosure has an integrated
bubble level and custom gap‑free, lift‑gate style
terminal blocks to make installation easier.
2 | Blue Line Gen2 TriTech Motion Detectors
Sealed Optics and Electronics
The optics and electronics are assembled into the
front enclosure and sealed with a protective cover to
prevent damage during installation. The sealed optical
chamber also prevents drafts and insects from
affecting the detector.
Test Features
Externally visible alarm LED can be disabled after
installation.
Certifications and approvals
These detectors are also designed to comply with the following:
Europe Complies with EN50131-2-4 Grade 2
Complies with EN50130-5 Class II
Complies with EN60529, EN50102 (IP30, IK04)
Complies with Directive 2002/95/EC - Restriction of the
use of certain Hazardous Substances (RoHS)
China Complies with CCC GB10408.1 and GB10408.9
Region Certification
GODKJENNELSESBEVIS [-WP6, -W12, WP12]
Europe CE 2004/108/EC: EMC Directive,
2006/95/EC: Low-Voltage Directive,
and 1999/5/EC Radio Equipment and
Telecommunications Terminal Equipment (R&TTE), 2011/65/EU: Restriction
of the use of certain hazardous substances in electrical and electronic equipment [-WP6G, WP12G, and W12G]
CE 2004/108/EC: EMC Directive,
2006/95/EC: Low-Voltage Directive,
and 1999/5/EC Radio Equipment and
Telecommunications Terminal Equipment (R&TTE), 2011/65/EU: Restriction
of the use of certain hazardous substances in electrical and electronic equipment [-WP12H, -W12H]
EN50131EN50131-2-4 [-WP12G]
Region Certification
FCC T3X-BLG2 [-W12G, -WP12G, -WP6G]
Canada IC 1249A-BLG2 [-W12G, -WP12G, -
France AFNOR 2820200003D0 [-WP12G]
AFNOR 2820200003C0 [-W12G]
AFNOR 2820200003B0 [-WP12H]
AFNOR 2820200003E0 [-WP6G]
AFNOR 2820200003A0 [-W12H]
China CCC 2010031901000323 [-CHI]
Sweden INTYG 11-266 [-W12G]
INTYG 11-264 [-WP6G]
INTYG 11-265 [-WP12G]
Brazil ANATEL 2140-10-1855 [-W12G, -WP12G, -
the Netherlands
NCP 2011062 [ISC-BPR2-w12, -WP12, ISC-
WP6G]
WP6G]
BPQ2-W12, ISC-BDL2-W12G, ISCBDL2-WP12G, ISC-BDL2-WP6G]]
EN50131EN50131-2-4 [-W12G]
EN50131EN50131-2-4 [-WP12H]
EN50131EN50131-2-4 [-WP6G]
EN50131EN50131-2-4 [-W12H]
Belgium INCERT B-509-0052/f [ISC-BDL2-W12G, -
INCERT B-509-0052/f [ISC-PDL1-W18G, -
USA UL cULus - ANSR: Intrusion-detection Units
WP12G, -WP6G]
WC30G, -WA18x; ISC-BDL2-WP12G]
(UL 639), ANSR7: Intrusion-detection
Units Certified for Canada (ULC-S306)
[-W12G, -WP12G, -WP6G]