L4 P G
Read all instructions. Failure to follow all instructions listed below may result in hazardous radiation exposure, electric shock, fire and/or serious injury. The term “tool” in all of the
warnings listed below refers to your mains-operated (corded) tool or battery­operated (cordless) tool.
The following labels are on your laser tool for your
convenience and safety. They indicate where the laser light is emitted by the tool. ALWAYS BE AWARE of their location when using the tool.
Do not direct the laser beam at persons or animals and do not stare into the laser beam yourself. This tool produces laser class 3R laser radiation and complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. This can lead to persons being blinded.
Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
DO NOT remove or deface any warning or caution labels. Removing labels increases the risk of exposure to laser radiation.
Use of controls or adjustments or performance of procedures other than those specified in this manual, may result in hazardous radiation exposure.
ALWAYS make sure that any bystanders in the vicinity of use are made aware of the dangers of looking directly into the laser tool.
DO NOT place the laser tool in a position that may cause anyone to stare into the laser beam intentionally or unintentionally. Serious eye injury could result.
ALWAYS position the laser tool securely. Damage to the laser tool and/or serious injury to the user could result if the laser tool fails.
ALWAYS use only the accessories that are recommended by the manufacturer of your laser tool. Use of accessories that have been designed for use with other laser tools could result in serious injury.
DO NOT use this laser tool for any purpose other than those outlined in this manual. This could result in serious injury.
DO NOT leave the laser tool “ON” unattended in any operating mode. DO NOT disassemble the laser tool. There are no user serviceable parts inside.
-4-
General Safety Rules
!
WARNING
!
WARNING
ACCORDING TO IEC/EN 60825-1: 2007
-5-
DO NOT modify the product in any way. Modifying the laser tool may result in hazardous laser radiation exposure.
DO NOT use the laser viewing glasses as safety goggles. The laser viewing glasses are used for improved visualization of the laser beam, but they do not protect against laser radiation.
DO NOT use the laser viewing glasses as sun glasses or in traffic. The laser viewing glasses do not afford complete UV protection and reduce color perception.
DO NOT use any optical tools such as, but not limited to, telescopes or transits to view the laser beam. Serious eye injury could result.
DO NOT stare directly at the laser beam or project the laser beam directly into the eyes of others. Serious eye injury could result.
SAVE THESE INSTRUCTIONS
Work area safety
Keep work area clean and well lit.
Cluttered or dark areas invite accidents.
DO NOT operate the laser tool around children or allow children to operate the laser tool. Serious eye injury could result.
Electrical safety
Batteries can
explode or leak, cause injury or fire. To reduce this
risk, always follow all instructions and warnings on the battery label and package.
DO NOT short any battery terminals. DO NOT charge alkaline batteries. DO NOT mix old and new batteries.
Replace all of them at the same time with new batteries of the same brand and type. DO NOT mix battery chemistries. Dispose of or recycle batteries per local code. DO NOT dispose of batteries in fire. Keep batteries out of reach of children. Remove batteries if the device will not be used for several months.
Personal safety
Stay alert, watch what you are doing and use common sense when operating a tool. Do not use a tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention
while operating a tool may result in serious personal injury or incorrect measurement results.
Use safety equipment. Always wear eye protection. Safety equipment such
as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries.
Mounting Magnets
Keep the tools mounting magnets away from cardiac pacemakers.
The magnets 4 generate a field that can impair the function of cardiac pacemakers.
• Keep the tools mounting magnets away from magnetic data medium and magnetically-sensitive equipment. The effect of the
magnets 4 can lead to irreversible data loss.
!
WARNING
The tool is intended for the accurate transfer of plumb up, down, level, and
square point.
Use and care
Use the correct tool for your application. The correct tool will do the
job better and safer.
Do not use the tool if the switch does not turn it on and off. Any tool
that cannot be controlled with the switch is dangerous and must be repaired.
Store idle tool out of the reach of children and do not allow persons unfamiliar with the tool or these instructions to operate the tool. Tools
are dangerous in the hands of untrained users.
Maintain tools. Check for misalignment or binding of moving parts, breakage of parts and any other condition that may affect the operation. If damaged, tool repaired before use. Many accidents are
caused by poorly maintained tools.
Use the tool, accessories, etc., in accordance with these instructions
and in the manner intended for the particular type of tool, taking into account the working conditions and the work to be performed. Use of the
tool for operations different from those intended could result in a hazardous situation.
Service
Have your tool serviced by a qualified repair person using only identical replacement parts. This will
ensure that the safety of the tool is maintained.
Develop a periodic maintenance schedule for tool. When cleaning a tool be careful not to disassemble any portion of the tool since internal wires may be misplaced or pinched or may be improperly mounted.
Certain cleaning agents such as gasoline, carbon tetrachloride, ammonia, etc. may damage plastic parts.
SAVE THESE INSTRUCTIONS.
-6-
Inserting/Replacing the Battery
Use only alkaline batteries. Open the battery cover 2 by pulling the
battery door towards back of tool. When inserting, pay attention to the correct polarity according to the representation on the inside of the battery compartment.
Always use batteries with the same power rating and from the same manufacturer.
For the proper disposal of the used batteries, see the section “Environmental Protection”.
• Remove the batteries from the tool when not using it for extended periods.
When storing for extended periods, the batteries can corrode and discharge themselves.
Low Battery Indicator
Laser blinks 8 times between 8 second intervals.
Intended Use
Preparation
The numbering of the product features shown refers to the illustration of the tool on the graphic page 2.
1 On/Off switch 2 Batter y compartment
3 Tripod mount 1/4-20 4 Magnets 5 Outlet for vertical laser dot 6 Outlet for down plumb dot 7 Outlet for front horizontal laser dot 8 Outlet for side horizontal laser dot
-7-
Features
Working range
(typical) . . . . . . . . . . . Up t o 1 00 ft (3 0m )
Accuracy Vertical (up) . . ±1/4in. at 100ft
(±6mm. at 30m)
Level. . . . . . . . . . . . . . . ±1/4in. at 100ft
(±6mm. at 30m)
Plumb Down . . . . . . . . . . ±1/4in. at 10ft
(±6mm. at 3m)
Self-Leveling Range . . . . . . . . . . . . ±5°
Operating
temperature. . . . . . . . . . . . . 32°F~104°F
(0°C ~40°C)
Ba tter ie s. . . . . . . . . . . . . . . 3 x 1 .5V AA
Weight . . . . . . . . . . . . . . 1.2lb (0.54 kg)
Tripod Mount . . . . . . . . . . . . . . . . 1/4-20
Laser Class . . . . . . . . . . . . . . . . . . . 3R
Laser Type . . . . . . . . . . . . . 630-670nm
<5mW max.
Initial Operation
• Protect the tool against moisture and direct sun irradiation.
• Do not subject the tool to extreme temperatures or variations in temperature.
For an example, do not leave it in a vehicle for long periods. In case of large variations in temperature, allow the tool to adjust to the ambient temperature before putting it into operation. In case of extreme temperatures or variations in temperature, the accuracy of the tool can be impaired.
• Avoid heavy impact or dropping of the tool. After heavy exterior
impact on the tool, an accuracy
check should always be carried out before continuing to work .
Switching On and Off
To switch on the tool, press the On/Off switch 1 once briefly. Immediately after switching on, the tool projects the three laser beams (Plumb Up, Plumb Down, Level ) from the exit openings 5, 6, and
7. Press the On/Off switch 1 twice briefly, the tool projects the four laser beams (Plumb Up, Plumb Down, Level and 90° reference Beam) from the exit openings 5, 6, 7 and 8.
Working Advice
The GPL4 has built-in magnets to mount to a metal surface to help when transferring points.
Technical Data
Operation
Keep the tool clean at all times. Do not immerse the tool into water or other fluids.
Wipe off debris using a moist and soft cloth. Do not use any cleaning agents or solvents.
If the tool should fail despite the care taken in manufacturing and testing procedures, repair should be carried out by an authorized after- sales service center for Bosch power tools. In all correspondence and spare parts orders, please always include the 10­digit article number given on the type plate of the tool.
ENVIRONMENT PROTECTION
Recycle raw materials & batteries instead of disposing of waste. The unit, accessories, packaging & used batteries should be sorted for environmentally friendly recycling in accordance with the latest regulations.
-8-
Maintenance and Service
Out of Level. If the laser is tilted too
much and can not self-leveling (>5°), the flashing laser beams will indicate the laser is not plumb. Try to reposition the laser on a level surface. Using the Laser to Plumb. (Fig. 1) To transfer a point from the floor to the ceiling, center the plumb down beam over the point you wish to transfer. The laser will project a bright laser beam on the ceiling. Mark the point as required. Using the Laser to Square. (Fig. 2) Place the unit on the floor or a fairly level surface near the walls or the objects to be squared. Measure from one wall to the laser beam at two points. One point near the unit and at another point farther away. (Note: the greater the distance between the two points the greater the possible accuracy). Rotate the unit until the two
measurements are equal. Do not move the unit until the rest of the measuring is completed. Now take two measurements from the other wall to that laser beam. If the measurements of these two points are the same, then the walls are square. If they are not equal, move the second wall until the two measurements are equal.
You can also square vertical surfaces to horizontal surfaces by using a plumb beam and a level beam.
Using the Laser to Level. Set the unit on a surface that is at a convenient height for marking a level reference plane on walls or other surfaces. The laser will generate a horizontal point of referece onto the surface.