Bosch FMM-7045 Specsheet

Fire Alarm Systems | FMM‑7045 Multiplex Addressable Manual Stations
FMM‑7045 Multiplex Addressable Manual Stations
www.boschsecurity.com
u Easy addressing with rotary switches
u Terminal connections and low current draw
The FMM‑7045 Multiplex Manual Stations are UL Listed fire alarm initiating devices that can be connected along with other multiplex devices on the D7039 Multiplex Expansion Module. The FPD‑7024 or D7024 Addressable Fire Alarm Control Panel (FACP) supervises the entire multiplex loop, including the FMM‑7045 or FMM‑7045‑D manual stations, for troubles, alarms, and ground fault conditions. Because each manual station occupies only one address on the multiplex bus, it can be addressed for any point within the 9 to 255 range allowed by the multiplex expansion module. These manual stations are generally installed near building exits such as stairways and doors, allowing persons evacuating the building to activate the fire alarm. They have optional scored acrylic breakrods and a pull handle that locks in the activated position, to allow easy identification of alarm activation points. These manual stations are high‑quality units constructed entirely of non‑toxic materials. They have a low profile and rounded edges to fit most design applications. All components are painted or have plated surfaces to inhibit corrosion. Non-corroding screw terminals are provided for wire connections.
u Replaceable scored acrylic break rod option
u UL Listed and ADA compliant
They are manufactured in conformance with the standards set forth in the Americans with Disabilities Act (ADA).
Functions
Alarm Action
The single‑action FMM‑7045 has a white pull‑down lever in its center. The dual‑action FMM‑7045‑D has a white push lever above the white pull‑down lever in its center. Pulling down the pull‑down lever latches it into place and sends an alarm signal to the control panel over the multiplex bus. The pull‑down lever cannot be reset unless the correct key is inserted into the manual station's lock and the unit is opened. The latching lever can then be restored to its normal position.
2 | FMM‑7045 Multiplex Addressable Manual Stations
Certifications and approvals
Region Certification
USA UL UNIU: Boxes, Non-Coded (UL38)
CSFM see our website
FDNY­CoA
#6173
Installation/configuration notes
Compatibility Information
The following table lists control panels compatible with the FMM‑7045 and FMM-7045-D manual stations:
Control Panels
Active products:
FPD-7024
Legacy products:
D7024*
* with firmware revision 2.0 or greater and with a D7039 Multiplex Expansion module
Addressing
Addresses are set using three rotary switches. For programming information, refer to the D7024 FACP
Operation and Installation Guide or the FPD‑7024 Operation and Installation Guide and the FMM-7045, FMM-7045-D Multiplex Addressable Manual Stations Installation Instructions.
Mounting
The manual stations are for indoor use only.
Parts included
Quant. Component
1 Manual station
1 FMM‑100GR Scored Acrylic Breakrod
1 D102 Key (1358)
1 Literature pack
Technical specifications
Environmental Considerations
Environment: Dry, indoor
Radio Frequency Interference (RFI) Immunity:
Temperature (Operating):
No alarm on critical frequencies in the range from 26 MHz to 950 MHz at field strengths less than 30 V/m.
+32°F to +120°F (0°C to +49°C)
Mechanical Properties
Dimensions (H x W x D): 4.75 in. x 3.75 in. x 3.25 in.
Material: Die cast zinc alloy and steel
(12 cm x 9.5 cm x 8.2 cm)
Power Requirements
Current Draw (Mux Bus Average):
Voltage (Operating): 12 VDC nominal (provided by the MUX
Alarm: 0.55 mA Standby: 0.55 mA
bus)
Ordering information
Notice
If a pull station is needed for outdoor use or in an unheated area, use an FMM‑100 Family Pull Station rated for the environment and wired to a multiplex module within the interior of the building.
The FMM‑7045 manual stations flush or surface mount on a standard four‑inch square back box with a single‑gang mud ring so that the total depth of the box is at least 2.25 in. (5.7 cm).
Notice
These manual stations do not fit an FMM‑100BB‑R Back Box.
Wiring
The terminal block accepts wiring up to 12 AWG (ISO 4 mm2) in diameter. For multiplex wiring information, refer to the D7039 Installation Instructions.
FMM‑7045 Single‑Action Manual Station
The single‑action manual station is UL listed and meets Americans with Disabilities Act (ADA) requirements. Its address on the polling circuit is easily set with rotary switches. The pull handle locks in the activated position and is reset by opening the unit with a key and then relocking it.
Order number FMM-7045
FMM‑7045‑D Double‑Action Manual Station
The double‑action manual station is UL listed and meets Americans with Disabilities Act (ADA) requirements. Its address on the polling circuit is easily set with rotary switches. The pull handle locks in the activated position and is reset by opening the unit with a key and then relocking it.
Order number FMM-7045-D
Accessories
D102 Replacement Key
Replacement key (#1358) for LOCK‑1358 and the D101 lock.
Order number D102