Digital Video Recorder 440/480 Series Table of Contents | en3
Table of Contents
1Safety7
1.1Safety precautions7
1.2Important safety instructions7
1.3Important Notices9
1.4FCC and UL11
1.5Bosch notices12
2Introduction13
2.1Digital video recorder applications13
2.1.1Versions13
2.1.2Manuals13
2.1.3Features14
2.2Unpacking14
2.2.1Package contents14
2.3Installation environment15
2.3.1Mounting15
2.3.2Ventilation15
2.3.3Temperature15
2.3.4Power Supply15
2.3.5Environment15
2.4Associated equipment15
2.5Warranty15
3Quick install16
3.1Connections16
3.1.1Primary connections16
3.1.2Optional connections16
3.1.3Powering up16
3.2First-time use17
3.3Quick install menu18
3.3.1International18
3.3.2Continuous Recording19
3.3.3Network20
4Hardware setup21
4.1Camera connections21
4.2Audio connections21
4.3Monitor connections22
4.3.1VGA (Monitor A)22
4.3.2CVBS22
4.4RS-232 COM port connections23
4.5Ethernet connection24
4.6USB connectors25
4.7RS485 port25
4.8External alarm I/O connection26
4.9Power supply27
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
4en | Table of ContentsDigital Video Recorder 440/480 Series
4.10Maintenance27
5Operating instructions28
5.1Front panel controls29
5.1.1Keys29
5.1.2Indicators31
5.2Mouse Controls32
5.4Viewing pictures33
5.4.1Monitor A33
5.4.2Monitor B33
5.4.3Viewing34
5.5Live and playback36
5.5.1Live mode36
5.5.2Playback mode36
5.6Overview of the menu system37
5.6.1Access using the front panel keys37
5.6.2Access using the mouse37
5.6.3Main menu38
5.7Search39
5.7.1Date/time search40
5.7.2Event search41
5.7.3Smart search42
5.8Export43
5.9System information44
5.10Log47
5.11Triggers and alarms48
5.11.1Alarm inputs48
5.11.2Motion events49
5.11.3Video loss alarm49
5.11.4Multiple alarms49
6Configuration menu50
6.1Camera52
6.1.1Camera52
6.1.2Maximum frame rates DVR 440 53
6.1.3Maximum frame rates DVR 48053
6.1.4Video adjustment53
6.1.5PTZ54
6.1.6Continuous Recording55
6.1.7Input Recording56
6.1.8Motion Recording57
6.1.9Network Live Streaming58
6.1.10Video format59
6.2Schedule60
6.2.1Schedule60
6.3Display61
6.3.1Language61
6.3.2Monitor A61
6.3.3Monitor B61
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Table of Contents | en5
6.4Event62
6.4.1Input62
6.4.2Motion63
6.5Network66
6.5.1TCP/IP66
6.5.2Streaming to mobile devices66
6.5.3Connecting using a smart mobile phone67
6.5.4DDNS68
6.5.5Notification68
6.5.6Mail69
6.6System70
6.6.1Date/Time70
6.6.2NTP70
6.6.3Beeper70
6.6.4Users71
6.6.5Configuration72
6.6.6Hard Disk73
6.6.7System74
7Web Client Software75
7.1Getting started75
7.1.1System requirements75
7.1.2Connecting to the DVR 400 Series the first time75
7.2How to log on76
7.2.1Menu structure differences76
7.3Introducing the browser window77
7.4Live mode77
7.4.1PTZ camera control77
7.4.2Camera views78
7.5Playback mode79
7.6Export mode80
7.7Configuration mode81
8Archive Player82
8.1Getting started82
8.1.1System requirements82
8.1.2Installation82
8.1.3Starting the Program82
8.2Introducing the main window83
8.2.1Open button83
8.3Camera Views83
8.4Viewing Images84
8.4.1Assigning Cameos84
8.5Using the playback controls84
8.5.1Capturing a still image85
8.6Find image85
8.7Video slider bar 85
8.8Checking authenticity 85
8.9Exit button 85
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
6en | Table of ContentsDigital Video Recorder 440/480 Series
9Menu default values86
10Technical specifications90
10.1Electrical90
10.1.1Mechanical91
10.1.2Environmental91
10.1.3Electromagnetic and Safety92
10.2USB memory sticks92
AAppendix93
A.1Software licenses93
A.1.1Bosch software93
A.1.2Other licenses — copyright notices93
A.1.3Warranties and disclaimer of warranties94
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Safety | en7
1Safety
1.1Safety precautions
DANGER!
High risk: This symbol indicates an imminently hazardous situation such as "Dangerous
Voltage" inside the product.
If not avoided, this will result in an electrical shock, serious bodily injury, or death.
WARNING!
Medium risk: Indicates a potentially hazardous situation.
If not avoided, this could result in minor or moderate bodily injury.
CAUTION!
Low risk: Indicates a potentially hazardous situation.
if not avoided, this could result in property damage or risk of damage to the unit.
1.2Important safety instructions
Read, follow, and retain for future reference all of the following safety instructions. Heed all
warnings on the unit and in the operating instructions before operating the unit.
1.Cleaning - Unplug the unit from the outlet before cleaning. Follow any instructions
provided with the unit. Generally, using a dry cloth for cleaning is sufficient but a moist,
fluff-free cloth or leather shammy may also be used. Do not use liquid cleaners or aerosol
cleaners.
2.Heat Sources - Do not install the unit near any heat sources such as radiators, heaters,
stoves, or other equipment (including amplifiers) that produce heat.
3.Ventilation - Any openings in the unit enclosure are provided for ventilation to prevent
overheating and ensure reliable operation. Do not block or cover these openings. Do not
place the unit in an enclosure unless proper ventilation is provided, or the manufacturer's
instructions have been adhered to.
4.Water - Do not use this unit near water, for example near a bathtub, washbowl, sink,
laundry basket, in a damp or wet basement, near a swimming pool, in an outdoor
installation, or in any area classified as a wet location. To reduce the risk of fire or
electrical shock, do not expose this unit to rain or moisture.
5.Object and liquid entry - Never push objects of any kind into this unit through openings
as they may touch dangerous voltage points or short-out parts that could result in a fire
or electrical shock. Never spill liquid of any kind on the unit. Do not place objects filled
with liquids, such as vases or cups, on the unit.
6.Lightning - For added protection during a lightning storm, or when leaving this unit
unattended and unused for long periods, unplug the unit from the wall outlet and
disconnect the cable system. This will prevent damage to the unit from lightning and
power line surges.
7.Controls adjustment - Adjust only those controls specified in the operating instructions.
Improper adjustment of other controls may cause damage to the unit. Use of controls or
adjustments, or performance of procedures other than those specified, may result in
hazardous radiation exposure.
8.Overloading - Do not overload outlets and extension cords. This can cause fire or
electrical shock.
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
8en | SafetyDigital Video Recorder 440/480 Series
9.Power supply cord and plug protection - Power supply cords should be routed so that
they are not likely to be walked on or pinched by items placed upon or against them,
playing particular attention to cords and plugs, convenience receptacles, and the point
where they exit from the appliance.
10. Power disconnect - Units have power supplied to the unit whenever the power cord is
inserted into the power source. The power cord plug is the main power disconnect
device for switching off the voltage for the unit.
11. Power sources - Operate the unit only from the type of power source indicated on the
label. Before proceeding, be sure to disconnect the power from the cable to be installed
into the unit.
12. Servicing - Do not attempt to service this unit yourself. Opening or removing covers may
expose you to dangerous voltage or other hazards. Refer all servicing to qualified service
personnel.
13. Damage requiring service - Unplug the unit from the main AC power source and refer
servicing to qualified service personnel when any damage to the equipment has
occurred, such as:
–the power supply cord or plug is damaged;
–exposure to moisture, water, and/or inclement weather (rain, snow, etc.);
–liquid has been spilled in or on the equipment;
–an object has fallen into the unit;
–unit has been dropped or the unit cabinet is damaged;
–unit exhibits a distinct change in performance;
–unit does not operate normally when the user correctly follows the operating
instructions.
14. Replacement parts - Be sure the service technician uses replacement parts specified by
the manufacturer, or that have the same characteristics as the original parts.
Unauthorized substitutions could void the warranty and cause fire, electrical shock, or
other hazards.
15. Safety check - Safety checks should be performed upon completion of service or repairs
to the unit to ensure proper operating condition.
16. Installation - Install in accordance with the manufacturer's instructions and in
accordance with applicable local codes.
17. Attachments, changes or modifications - Only use attachments/accessories specified by
the manufacturer. Any change or modification of the equipment, not expressly approved
by Bosch, could void the warranty or, in the case of an authorization agreement, authority
to operate the equipment.
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Safety | en9
1.3Important Notices
Accessories - Do not place this unit on an unstable stand, tripod, bracket, or mount. The unit
may fall, causing serious injury and/or serious damage to the unit. Use only with the cart,
stand, tripod, bracket, or table specified by the manufacturer. When a cart is used, use
caution and care when moving the cart/apparatus combination to avoid injury from tip-over.
Quick stops, excessive force, or uneven surfaces may cause the cart/unit combination to
overturn. Mount the unit per the manufacturer's instructions.
All-pole power switch - Incorporate an all-pole power switch, with a contact separation of at
least 3 mm in each pole, into the electrical installation of the building.If it is needed to open
the housing for servicing and/or other activities, use this all-pole switch as the main
disconnect device for switching off the voltage to the unit.
Battery replacement - For qualified service personnel only - A lithium battery is located
inside the unit enclosure. To avoid danger of explosion, replace the battery as per
instructions. Replace only with the same or equivalent type recommended by the
manufacturer. Refer all servicing to qualified service personnel.
Batteries must not be disposed of in household waste. Dispose of batteries only at suitable
collection points and, in the case of lithium batteries, mask the poles.
For further information refer to: http://www.boschsecurity.com/standards
Coax grounding:
–Ground the cable system if connecting an outside cable system to the unit.
–Connect outdoor equipment to the unit's inputs only after this unit has had its grounding
plug connected to a grounded outlet or its ground terminal is properly connected to a
ground source.
–Disconnect the unit's input connectors from outdoor equipment before disconnecting
the grounding plug or grounding terminal.
–Follow proper safety precautions such as grounding for any outdoor device connected to
this unit.
U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides
information regarding proper grounding of the mount and supporting structure, grounding of
the coax to a discharge unit, size of grounding conductors, location of discharge unit,
connection to grounding electrodes, and requirements for the grounding electrode.
Disposal - Your Bosch product was developed and manufactured with high-quality material
and components that can be recycled and reused. This symbol means that electronic and
electrical appliances, which have reached the end of their working life, must be collected and
disposed of separately from household waste material. Separate collecting systems are
usually in place for disused electronic and electrical products. Please dispose of these units
at an environmentally compatible recycling facility, per European Directive 2002/96/EC.
Electronic Surveillance - This device is intended for the use in public areas only. U.S. federal
law strictly prohibits surreptitious recording of oral communications.
Electrostatic-sensitive device - Use proper CMOS/MOS-FET handling precautions to avoid
electrostatic discharge. Wear required grounded wrist straps and observe proper ESD safety
precautions when handling the electrostatic-sensitive printed circuit boards.
Environmental statement - Bosch has a strong commitment towards the environment. This
unit has been designed to respect the environment as much as possible.
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
10en | SafetyDigital Video Recorder 440/480 Series
Fuse rating - For protection of the device, the branch circuit protection must be secured with
a maximum fuse rating of 16A. This must be in accordance with NEC800 (CEC Section 60).
Grounding and polarization - This unit may be equipped with a polarized alternating current
line plug (a plug with one blade wider than the other blade). This safety feature allows the
plug to fit into the power outlet in only one way. If unable to insert the plug fully into the
outlet, contact a locally certified electrician to replace the obsolete outlet. Do not defeat the
safety purpose of the polarized plug.
Alternately, this unit may be equipped with a 3-pole grounding plug (a plug with a third pin for
earth grounding). This safety feature allows the plug to fit into a grounded power outlet only.
If unable to insert the plug into the outlet, contact a locally certified electrician to replace the
obsolete outlet. Do not defeat the safety purpose of the grounding plug.
Moving - Disconnect the power before moving the unit. Move the unit with care. Excessive
force or shock may damage the unit and the hard disk drives.
Permanently connected equipment - Incorporate a readily accessible disconnect device
external to the equipment.
Pluggable equipment - Install the socket outlet near the equipment so it is easily accessible.
Rack-mount
–Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment may be greater than room
ambient. Therefore, consideration should be given to installing the equipment in an
environment compatible with the maximum ambient temperature (Tma) specified by the
manufacturer.
–Reduced Air Flow - Installation of the equipment in a rack should be such that the amount
of air flow required for safe operation of the equipment is not compromised.
–Mechanical loading - Mounting of the equipment in the rack should be such that a
hazardous condition is not achieved due to uneven mechanical loading.
–Circuit Overloading - Consideration should be given to the connection of the equipment
to the supply circuit and the effect that overloading of the circuits might have on
overcurrent protection and supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
–Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct connections
to the branch circuit (e.g. use of power strips).
SELV - All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits
should only be connected to other SELV circuits.
Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security
Systems cannot be held liable for any damage that results from missing video information. To
minimize the risk of lost digital information, Bosch Security Systems recommends multiple,
redundant recording systems, and a procedure to back up all analog and digital information.
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Safety | en11
1.4FCC and UL
FCC Information
(U.S.A. and Canadian Models Only)
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
–reorient or relocate the receiving antenna;
–increase the separation between the equipment and receiver;
–connect the equipment into an outlet on a circuit different from that to which the
receiver is connected;
–consult the dealer or an experienced radio/TV technician for help.
Intentional or unintentional modifications, not expressly approved by the party responsible
for compliance, shall not be made. Any such modifications could void the user's authority to
operate the equipment. If necessary, the user should consult the dealer or an experienced
radio/television technician for corrective action.
The user may find the following booklet, prepared by the Federal Communications
Commission, helpful: How to Identify and Resolve Radio-TV Interference Problems. This booklet
is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004000-00345-4.
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
12en | SafetyDigital Video Recorder 440/480 Series
1.5Bosch notices
Copyright
This manual is the intellectual property of Bosch Security Systems and is protected by
copyright.
All rights reserved.
Trademarks
All hardware and software product names used in this document are likely to be registered
trademarks and must be treated accordingly.
Note:
This manual has been compiled with great care and the information it contains has been
thoroughly verified. The text was complete and correct at the time of printing. The ongoing
development of the products may mean that the content of the user guide can change without
notice. Bosch Security Systems accepts no liability for damage resulting directly or indirectly
from faults, incompleteness or discrepancies between the user guide and the product
described.
More information
For additional information, please contact the nearest Bosch Security Systems location or
visit our web site at:
www.boschsecurity.com
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Introduction | en13
2Introduction
2.1Digital video recorder applications
The Digital Video Recorder 440/480 Series is a video and audio recording system that records
multiple camera and audio signals while simultaneously providing live multiscreen viewing and
playback. The unit has comprehensive search and playback facilities for viewing stored video.
Once configured, all recording takes place in the background without requiring operator
intervention.
Maximum recording rates for CIF resolution of 30 (NTSC) and 25 (PAL) images per second
(IPS), per channel, are guaranteed. By using only 4 channels you can record 2CIF in real time
(30/25 IPS). Recording at 4CIF is also possible by lowering the IPS setting. The recording rate
and quality are selectable per camera. An internal hard disk provides various storage
capacities for recording.
All models have extensive alarm handling functions and telemetry control. Alarm functions
include motion detection in user-definable areas of the image on any camera input.
The unit can be easily operated and programmed via the front panel control keys, mouse, and
the on-screen display menu system. Two monitor outputs provide full-screen, multiscreen,
and sequenced viewing.
The video inputs, audio input and output, and alarm inputs and output are on the rear panel. A
VGA connector provides output for an A monitor. A CVBS video output in either NTSC or PAL
is also provided for Monitor B. Monitor A displays full-screen or quad digital pictures that can
be frozen and zoomed. Monitor B displays live full-screen pictures.
Use the Web application via a network for live viewing, playback, and configuration. Four
simultaneous users can control the DVR 400 Series. The DVR 400 Series includes an
authenticity check for both local and remote playback. A dedicated PC player is provided for
playback of secure video files.
2.1.1Versions
The DVR 440 Series models have 4 video channels and 4 alarm inputs; the DVR 480 Series
models have 8 video channels and 4 alarm inputs. Both versions operate in a similar manner.
The illustrations in this manual show the 4-channel version. The 8-channel version has 4
additional video channels and 4 additional alarm inputs.
2.1.2Manuals
This manual contains information about:
–Quick Installation - a brief overview on how to set up and install the product.
–Hardware Setup - a detailed description for installers on how to install the product.
–Operation - a detailed description for end-users on how to operate the unit.
–Web Control and Archive Player - a detailed description for end-users and administrators
on how to set up and operate the Web Control and Archive Player software.
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
14en | IntroductionDigital Video Recorder 440/480 Series
2.1.3Features
The DVR 440/480 Series has the following features:
–4/8 camera inputs
–1 audio input and 1 audio output
–Simultaneous recording and playback
–H.264 compression
–10/100Base-T Ethernet port for Ethernet connection and networking
–RS485 and RS232 serial port for data communication
–VGA monitor output (Monitor A)
–Full-screen and multiscreen display capabilities in live and playback modes
–CVBS monitor output (Monitor B)
–Full-screen in live with sequence
–Motion detection
–4/8 switching (alarm) inputs and 1 alarm output
–Video loss detection
–Audible alarm
–Pan, tilt, and zoom camera control via RS485/RS232
–Local archiving via USB
–E-mail notification with 10-second video clip on alarm
–Bosch DVR viewer App for live and PTZ control
2.2Unpacking
Inspect the package for visible damage. If any items appear to have been damaged during
transport, notify the shipping company. Unpack carefully. This is electronic equipment and
should be handled with care to prevent damage to the unit. Do not attempt to use the unit if
any components are damaged. If any items are missing, notify your customer service
representative or Bosch Security Systems sales representative. The shipping carton is the
safest container in which to transport the unit. Save it and all packing materials for future use.
If the unit must be returned, use the original packing materials.
2.2.1Package contents
Check for the following items:
–Digital Video Recorder (DVR 440/480 Series unit)
–Operation manual (this manual)
–Power supply cords/power adapter
–Terminal blocks for external I/O connectors
–CD-ROM containing the software and documentation
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Introduction | en15
2.3Installation environment
2.3.1Mounting
The DVR 440/480 Series is supplied as a desktop unit.
2.3.2Ventilation
Ensure that the location planned for the installation of the unit is well ventilated. Take note of
the locations of the cooling vents in the unit's enclosure and ensure that they are not
obstructed.
2.3.3Temperature
Observe the unit's ambient temperature specifications when choosing an installation space.
Extremes of heat or cold beyond the specified operating temperature limits may cause the
unit to fail. Do not install the unit on top of hot equipment.
2.3.4Power Supply
Ensure that the site's AC power supply is stable and within the rated voltage of the unit. If the
site's AC power is likely to have spikes or power dips, use power line conditioning or an
uninterrupted power supply (UPS).
2.3.5Environment
The unit is designed to operate in a clean office environment. Elevated levels of dust may
cause the unit to fail.
2.4Associated equipment
A typical system could contain the following components (not included with the unit):
–Primary VGA monitor for multiscreen monitoring (monitor A)
–Second CVBS monitor for spot/alarm monitoring (monitor B)
–Cameras with 1 Vpp composite video outputs
–Amplified microphone
–Audio amplifier with speaker
–Video coaxial cable with BNC connectors for connecting the video signals
–Audio cable with RCA connectors for connecting audio signals.
–AC power supply outlet for the unit that allows for secure isolation (for operational
reasons, the unit has no on/off switch)
–PC and network for remote applications
–Pan/tilt/zoom control units
2.5Warranty
Failure to follow the Safety Instructions, Installation Instructions, and any other instructions
noted in this manual may result in damage to the unit and void the warranty.
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
16en | Quick installDigital Video Recorder 440/480 Series
3Quick install
To get the unit quickly operational, make the connections described below and then enter the
relevant data in the Quick install menu. The Quick install menu appears the first time the unit
is started.
3.1Connections
Figure 3.1 Back panel connections for the 4-channel model*
* 8-channel models have 8 video connectors and 2 alarm input connectors.
3.1.1Primary connections
1.Connect the cameras to the VIDEO IN BNC connectors.
2.Connect monitor A to the VGA MON A output (supporting 800x600, 1024x768, or
1280x1024).
3.Connect a USB mouse to the USB port.
3.1.2Optional connections
1.Connect monitor B to the C MON B BNC connector.
2.Connect an audio signal to the AUDIO IN RCA (CINCH) input.
3.Connect the AUDIO OUT RCA (CINCH) output to the monitor or an audio amplifier.
4.Connect up to 4/8 alarms to the ALARM IN inputs (via the supplied terminal blocks).
5.Connect the ALARM OUT output (via the supplied terminal blocks).
6.Connect a pan/tilt/zoom control unit to the RS-485 port (via the supplied terminal block).
7.Connect to your network via the RJ-45 Ethernet port.
8.Connect a “Bosch RS232 to Bi-phase converter” to the RS-232 port if required.
3.1.3Powering up
Switch on all connected equipment.
–Connect the power unit to the AC power outlet.
–Connect the DC power cord to the 12VDC connector on the unit.
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Quick install | en17
3.2First-time use
The Quick install menu opens the first time the unit is used. Fill in the basic settings in the
three tabs to get the unit operational. The unit begins recording automatically when the Quick
install menu is closed.
To open the Quick install menu at any other time:
1.Press the menu key to bring up the System Control Bar.
2.Press the menu key again to enter the main menu.
–The main menu appears on monitor A.
3.Select System, then the Configuration submenu, and finally Quick install.
Navigating
Use a USB mouse or the following front panel keys:
–Use the enter key to select a submenu or item.
–Use the arrow keys to move through a menu or list.
–Use the exit key to go back or to switch off the menu.
After bootup, the unit shows the log-in screen over a quad display. The default User ID is
ADMINISTRATOR, the default password is 000000 (six zeros).
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
18en | Quick installDigital Video Recorder 440/480 Series
3.3Quick install menu
The Quick install menu contains three tabs: International, Continuous Recording, and
Network. Click the Exit button to exit the Quick install menu. Changing Quick install settings
overwrites customized settings.
3.3.1International
Figure 3.2 Quick install - International
LanguageSelect the language for the menu from the list.
Time zoneSelect a time zone from the list.
Time formatSelect either a 12 or a 24 hour clock format.
TimeFill in the current time.
Date formatSelect from three date formats which show either the month (MM),
the day (DD), or the year (YYYY) first.
DateFill in the current date.
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Quick install | en19
3.3.2Continuous Recording
Figure 3.3 Quick install - Continuous Recording
Set the Continuous Recording Resolution, Quality, Frame rate, Covert, and Audio for each
profile in the table.
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
20en | Quick installDigital Video Recorder 440/480 Series
3.3.3Network
Figure 3.4 Quick install - Network
Fill in the settings that control the behavior of the unit with respect to a network.
DVR IDEnter a unique DVR ID to be used in the network.
DHCPEnable DHCP to have IP address, subnet mask, and default
gateway assigned automatically by the network server.
The actual values are displayed.
IP address, Subnet
mask, and Gateway
Fill in the IP, subnet mask, gateway addresses, and DNS server
addresses when DHCP is not enabled.
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Hardware se tup | en21
4Hardware setup
This chapter contains detailed information about the hardware installation and connection of
external equipment to the unit. The connector types and their pin signals are described. Most
of the connectors are located at the rear panel of the unit. For convenience, one USB port is
located on the front of the unit to connect a mouse or memory device.
All the input/output ports are Safety Extra Low Voltage (SELV) circuits. SELV circuits should
only be connected to other SELV circuits.
4.1Camera connections
Connect cameras to the VIDEO IN connectors on the back of the unit using 75 ohm video
coaxial cables with BNC connectors.
The unit automatically configures itself as a PAL or NTSC unit. The unit determines the
standard by detecting the signal format of the VIDEO IN 1 during startup. The unit can also be
manually set to PAL or NTSC in the ‘Camera menu’ under ‘Video format’.
Specifications
Input signal: Composite video 1 Vpp, 75 ohm
Color standard: PAL/NTSC, auto-detect
Gain control: Automatic gain control for each video input
Connector type: BNC
Figure 4.1 Camera video inputs - 4 channels
4.2Audio connections
The unit has 1 audio input and 1 audio output. Connect using audio cable with RCA (CINCH)
compatible connectors.
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
22en | Hardware setupDigital Video Recorder 440/480 Series
4.3Monitor connections
Up to two monitors can be connected through the VGA and CVBS connections.
4.3.1VGA (Monitor A)
Connect the unit to one VGA monitor using standard VGA cable. It is advised to use 17”
monitors or larger when using LCD(s).
Specifications
Output signal: VGA
Resolution: 800x600, 1024x768, or 1280x1024
Color: True color (32 bit)
Connector type: DE-15
Figure 4.3 VGA monitor connector
4.3.2CVBS
Connect the unit to a CCTV monitor using 75 ohm video coaxial cables with BNC connectors.
The unit provides a 1 Vpp CVBS signal.
If the monitor has a loop-through connection and the loop-through output is available, select
the 75 ohm impedance setting on the monitor. If the monitor's loop-through output is
connected to an additional device, the device's termination is set to 75 ohm and the monitor's
termination is set to high impedance.
Note: This is not necessary on devices with automatic termination.
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Hardware se tup | en23
4.4RS-232 COM port connections
The RS-232 COM port is used to connect a PC to the unit for service purposes or to connect a
Bosch “RS-232 to Bi-Phase Converter”. For service purposes, use a null-modem cable to
connect the serial port of the PC to the unit. The Baud rate can be selected in the menu
system.
Specifications
Connector type: 9-pole D-type male connector
Maximum input voltage: ±25V
Communicaton protocol: Output signals according EIA/TIA-232-F
Figure 4.5 RS-232 COM port connector
Signal namePin numberDescription
DCD_in1Carrier detection signal (not used)
RX2RS-232 receive signal
TX3RS-232 transmit signal
N/C4No connection
System ground5System ground
N/C6No connection
RTS7RS-232 request to send signal
CTS8RS-232 clear to send signal
N/C9No connection
Tab le 4 .1 RS232 console por t socket
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
24en | Hardware setupDigital Video Recorder 440/480 Series
4.5Ethernet connection
The standard RJ-45 Ethernet socket is used to connect the unit directly to a PC or to a
network. To connect directly to a network hub, use a straight-through network cable. To
connect directly to a PC, use a cross-over network cable. Consult with your local IT personnel
for the specific type of cable needed. The maximum cable length from node to node is limited
to 100 meters (300 feet).
Specifications
Connection: 10/100 BaseT, IEEE 802.3
Differential signal voltage: ± 2.8 V maximum, inputs have transient overvoltage protection
Ethernet port details: EEE 802.3/802.3u — 100Base-TX/10Base-T physical layer
Auto negotiation: 10/100, full/half duplex
Cable length: 100 meters (100 ohm unshielded twisted pair cable or 150 ohm shielded
twisted pair cable, category 5 or higher).
Impedance: built-in compensation for impedance matching
Indicators: ACT, 10/100
Figure 4.6 RJ-45 Ethernet connector
Signal namePin numberDescription
LAN_TX +1Ethernet transmit line plus
LAN_TX -2Ethernet transmit line minus
LAN_RX +3Ethernet receive line plus
N/C4No connection
N/C5No connection
LAN_RX -6Ethernet receive line minus
N/C7No connection
N/C8No connection
Tab le 4 .2 LAN - RJ-45 Ethernet socket
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Hardware se tup | en25
4.6USB connectors
A USB 2.0 connector is located at the rear panel of the unit to which a mouse, for example,
can be connected. For convenience, the USB 2.0 port is located on the front of the unit to
connect a mouse or USB memory device. (Recording to a USB-drive is not supported.)
Figure 4.7 USB connector (on front and on rear)
4.7RS485 port
Connect Bosch or third-party controllable cameras to the unit for pan, tilt, and zoom control.
The Bosch protocol is supported with the following baud settings:
–9600 baud
–8 data bits
–1 stop bit
–no parity
–no flow control
Figure 4.8 RS-485 connector
Signal namePin numberDescription
TX -1Data transmission
TX +2Data transmission
GND3Shield
Tab le 4 .3 RS485 pin definition
The recommended cable cross section is AWG 28-16 (0.08-1.5 mm2).
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
26en | Hardware setupDigital Video Recorder 440/480 Series
4.8External alarm I/O connection
Alarm inputs and outputs are supplied screw down terminal blocks. The screw terminal blocks
are supplied with the unit.
Connecting the inputs
Each (alarm) input line can be switched by a contact from external devices. Wire them as
either Normally Open (N/O) or Normally Closed (N/C). Configure the alarm inputs as N/O or
N/C in the menu system. The default is N/O.
Specifications
Alarm input impedence: Internal pull-up 10 K to +5 V
Input voltage range: -2 VDC minimum to 15 VDC maximum
Input voltage threshold: low voltage 0.5 V maximum, high voltage 2 V minimum
Cable cross section: AWG 26-16 (0.13-1.5 mm2)
Connecting the alarm output
The alarm output relay responds to input alarms and triggers. Configure the alarm output as
N/O or N/C in the menu system. The relay is active for the duration of the driving event. Only
connect resistive loads to the alarm output relays. Do not exceed 30 Vac, 24 Vdc, 500 mA
(continuous), or 10 VA on an alarm output relay's contacts.
DANGER!
Electrical voltage.
Risk of electric shock and damage to the unit.
The contacts must not be used at AC line voltages.
Specifications
Switching current (resistive): 500 mA maximum
Switching voltage (resistive): 30 VAC/24 VDC maximum
Cable cross section: AWG 26-16 (0.13-1.5 mm2)
Figure 4.9 Alarm output connector for 4 channels
Figure 4.10 Alarm output connector
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Hardware se tup | en27
4.9Power supply
DC power is supplied to the unit from an AC/DC power supply unit delivered with the unit. For
operational reasons, the unit has no on/off switch. This means that the unit is always powered
as long as the power cable from the power supply unit is connected to the 12VDC socket.
Maintenance of this unit is limited to external cleaning and inspection. Refer all servicing to
qualified service personnel.
DANGER!
Electrical voltage. Risk of electric shock.
Do not open the top cover or attempt to service the unit. No user serviceable parts inside.
Refer all servicing to qualified service personnel. Opening the top cover will void the warranty!
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
28en | Operating instructionsDigital Video Recorder 440/480 Series
5Operating instructions
These instructions explain the purpose of the front panel keys.
The functions available can be limited by setting passwords. Access to the unit’s functions are
determined by the user level of the user logged in.
FunctionAdministrator levelAdvanced User levelNormal User level
View liveYesYesYes
SequenceYesYesYes
QuadYesYesYes
OSDYesYesYes
ZoomYesYesYes
Pan/Tilt/Zoom (PTZ)YesYesYes
PlaybackYesYesNo (configurable)
SearchYesYesNo (configurable)
ExportYesYesNo (configurable)
Acknowledge AlarmYesYesNo (configurable)
System MenusYesNoNo
CovertYesNoNo
Tab le 5 .1 User Levels and Permissions
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Digital Video Recorder 440/480 Series Operating instructions | en29
5.1Front panel controls
400 series
Figure 5.1 Front panel controls - 4-channel model
400 series
Figure 5.2 Front panel controls - 8-channel model
5.1.1Keys
The keys on the front panel control all functions. Symbols on the keys show the functions.
Inactive keys emit an audible beep when pressed.
Arrow keys:
Up, Down, Left, Right
–move around through menu items or values when in menu mode
–in PTZ mode, the arrow keys can be used to control the pan or tilt functions of the
selected camera
–moves the visible area of the selected image in digital zoom mode
Enter key
–selects a submenu or menu item, or confirms selections made in menus
–displays the cameo submenu in full screen or quad modes
Menu key
–opens the system menu
Search key
–press to open the date/time search menu to look for recorded images
Export key
–press to open the export menu
PTZ key
–enables or disables the PTZ mode
Zoom in key
–PTZ zoom in key
–Digital zoom in key on active full-screen display
Zoom out key
–PTZ zoom out key
–Digital zoom out key
Bosch Security SystemsInstallation and Operation manualAM18-Q0605 | v2.0 | 2012.04
30en | Operating instructionsDigital Video Recorder 440/480 Series
Exit key
–press to return to previous level or to exit the menu system
Alarm indicator / acknowledge key
–flashes when an alarm is detected
–press to acknowledge an alarm event; an indicator light is located on the key
Camera keys (1-4)/(1-8)
–press to see a full-screen display of the video input
–the LED lights when the camera is recording
–the LED flashes during an alarm on the camera
Quad key
–press to go to quad mode
–in quad mode, press to toggle to full screen
Sequence key
–view cameras in sequence on full-screen or quad displays
OSD key
–press to view date/time and camera information, date/time only, or none
Digital zoom key (4-channel model)
–press to zoom in on the active full screen camera display
Multi-screen key (8-channel model)
–press to go to different multi-screen modes
Pause key
–press to freeze the picture
Reverse key
–in live mode, press to start reverse playback of recordings for the displayed cameras
–in playback mode, press to start or speed up reverse playback
–in pause mode, press to step back one frame
Play key
–in live mode, press to resume playback from the last selected playback position
–in pause or fast forward/reverse modes, press to resume playback
Fast forward key
–in live mode, press to start playback from one minute earlier
–in playback mode, press to speed up the forward playback rate
–in reverse playback mode, press to start forward playback
–in pause mode, press to step forward one frame
Stop key
–while in playback mode, press to return to live mode
AM18-Q0605 | v2.0 | 2012.04Installation and Operation manualBosch Security Systems
Loading...
+ 66 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.