Intrusion Alarm Systems | Conettix D6600 Communications Receiver/Gateway
Conettix D6600 Communications
Receiver/Gateway
www.boschsecurity.com
u 32 lines for public switched telephone network
(PSTN) communications with Two Way audio, Caller
ID, ANI and DNIS support
The Conettix D6600 Communications Receiver/
Gateway with Conettix IP hardware components works
in the following configurations:
• Telephone line communications over the public
switched telephone network (PSTN).
• Internet or intranet communications over a LAN or
WAN using standard user datagram protocol and
internet protocol (UDP/IP).
• Simultaneous PSTN and LAN or WAN
communications.
The Conettix network environment reduces signalreporting time, improves security, and provides instant
notification when a site experiences communication
problems. A D6600 with Conettix IP hardware is
compatible with most manufacturer’s fire and security
system control panels.
System overview
PSTN Communications Configuration
This configuration uses existing telephone lines. A
control panel's signal transmits over a PSTN analog
telephone line to the D6600. The D6600 translates the
u Award winning VOIP compensation feature reduces
signal errors caused by digitally distorted Contact ID
signals
u Up to 3200 network accounts for IPv6 and IPv4
network communications
u Supports NIST-FIPS197 certified 128 to 256 bit AES
encryption
u Designed with electrically isolated, hot-swappable
line cards and front panel access to CPU card
signal to a common data format and sends the signal
through Ethernet LAN, WAN, or RS-232 to a central
station automation system.
Internet or Intranet Communications Configuration
This configuration requires Conettix IP hardware
components, uses existing Internet or intranet
structures, and avoids additional telephone service
costs.
This configuration permits the Conettix D6200
Programming/Administration Software to connect to
the D6600 remotely. A control panel's signal transmits
over the LAN or WAN to the D6600. The D6600
translates the signal to a common data format and
sends the signal through Ethernet LAN, WAN, or
RS-232 to a central station automation system. The
central automation system sends information to
operator workstations.
parameters through a network connection or RS-232
serial port. Through the Conettix D6200 Programming/
Administration Software users can edit CPU and line
card parameters; view the status of all accounts in the
databases; add, edit, and delete accounts; and
configure network operations.
Notice
Conettix D6200 Programming/Administration
Software is compatible with the following
operating systems: Microsoft Windows XP,
Windows 7, Windows 8.
Dialed number identification
service (DNIS) adjusts line card
settings according to the
Handles more field dialers with
fewer line cards and allows you to
create virtual lines.
telephone number dialed by the
control panel.
1.Access Control
2.Commercial Monitoring
3.Residential Monitoring
4.PSTN
4.1 Private Branch Exchange (PBX)
4.2 Two-way Audio
4.3 Analog Telephone Lines
5.LAN/WAN
Caller identification (Caller ID)
alarm processing stores
corresponding handshake
formats. The processing
automatically recalls the format
Shortens the amount of time that
calls are connected to the
receiver.
Decreases money spent on fixed
hardware or monthly phone bills.
when the same caller
identification is processed.
Uses the Conettix D6641
Telephone Line Card.
Digital signal processing
technology in the cards allows the
D6600 to recognize more
communication formats and
accurately decode information.
5.1 Firewall, Router, and Hub
5.2 LAN
Page 3
| Conettix D6600 Communications Receiver/Gateway
3
Additional PSTN Communications Advantages
• Automatic number identification (ANI) system
identifies incoming telephone numbers.
• Each line card has four telephone lines.
• Receives signals on up to 32 telephone lines
simultaneously.
• Independent, configurable communication format
settings for each telephone line.
• Visual front panel light emitting diode (LED)
indicators for on-line and line-fault status conditions.
Two-way Audio
• Able to transfer calls to another line or extension.
• Activated by account numbers and by events.
LAN or WAN Gateway Communications
• Requires Conettix IP hardware components.
• Two-way communications with a control panel.
• Supervised network automation computer links.
• Supports up to 3200 network accounts.
• Ethernet configuration available.
• Supports 128-bit AES Rijndael encryption.
Supervision and Programming with Network
Communications
The protected premises sends supervision messages
to the D6600 at a programmed rate. Users can
program the supervision rate to be 5 seconds to 1275
seconds. The D6600 acknowledges the supervision
message, providing end-to-end security. If
authentication and encryption algorithms detect
potentially damaging activity, they alert the central
station operator.
The data network's communication link is continuously
supervised. Even when monitoring thousands of
control panels, the system consumes only a small
amount of bandwidth.
Front Panel Access
The D6600 enclosure design provides convenient
access to the CPU card or the hot-swappable
telephone line cards. A hot-swappable card can be
removed and replaced without affecting system
performance.
Flash Technology
Using the Conettix D6200 Programming/
Administration Software, flash technology in the
D6600 allows for software upgrades without
additional hardware or firmware changes.
(UL1610, UL1635), AMCX7: Central
Station Alarm Units Certified for Canada
(cULus), APAW: Police Station Alarm
Units (UL365, UL464), APAW7: Police
Station Alarm Units Certified for Canada
(cULus), APOU: Proprietary Alarm Units
(UL1076), APOU7: Proprietary Alarm
Units Certified for Canada (cULus),
UOJZ: Control Units, System (UL864,
9th edition)
FM
CSFM7165-1615:0242 7165 -- FIRE ALARM
CONTROL UNIT (COMMERCIAL)
CSFM7165-1615:0238 7165 -- FIRE ALARM
CONTROL UNIT (COMMERCIAL)
CSFM7300-1615:0179 7300 -- FIRE ALARM
CONTROL UNIT ACCESSORIES/MISC.
DEVICES
CSFM7300-1615:0168 7300 -- FIRE ALARM
CONTROL UNIT ACCESSORIES/MISC.
DEVICES
FCCESVUSA-25328-AL-N
CanadaULCAMCX7.S1871 - Central Station Alarm
Units Certified for Canada
ULCAPOU7.S1871 Proprietary Alarm Units
Certified for Canada
IC1249A-8925A
Hong KongHKFSD
BrazilANATEL0841-03-2045
Installation/configuration notes
The D6600 and Monitoring Centers
The D6600 has extended edges so that installers can
mount it easily into a rack cabinet. Mount up to eight
D6600 units into a standard 48.3 cm (19 in.) rack
cabinet to conserve floor space. Each D6600 connects
32 telephone lines. Eight D6600 units can connect a
total of 256 telephone lines, process 600,000 digital
accounts, and process 28,800 supervised Internet or
intranet accounts.
USAANSINational Institute of Standards and
Technology's Advanced Encryption
Standard Certification (Certificate
Number 82)
NISTNational Institute of Standards and
Technology AES Certification
Notice
Rack cabinets are sold separately by a variety of
manufacturers.
Incorporating Conettix IP Function into the D6600
With the correct Conettix IP hardware components,
the D6600 can supervise the network communications
link. The Conettix IP hardware components include:
• Conettix D6201 Series IP Security Keys
Page 4
| Conettix D6600 Communications Receiver/Gateway
4
• Conettix D6672 COM 1 Expansion Kit
• Conettix D6680 Ethernet Network Adapter
Network Communications and Control Panels
For network communications, it is necessary to use
one of following modules with the appropriate control
panel: Conettix C900V2 Dialer Capture Ethernet
Module or Conettix DX4020 Ethernet Network
Interface Module. Review the control panel
specifications for the recommended network interface
or dialer capture modules.
Parts included
QuantityComponent
1Conettix D6600 Communications Receiver/Gateway
1Conettix D6610 CPU Card
1Conettix D6615 CPU Terminator Card
1Conettix D6641 Telephone Line Card (Expanded Memory)
1Conettix D6645 Telephone Line Terminator Card
1Conettix D6200CD CD-ROM
Includes the Conettix D6200 Programming/Administration
Software
1P6601 Battery Cable
1P6602 Input and Output Cable
Technical specifications
Enclosure
Rack Mount Dimensions (4U):18 cm x 48.3 cm x 49.5 cm
(7.0 in. x 19.0 in. x 19.5 in.)
Standalone Dimensions:18 cm x 45 cm x 49.5 cm
(7.0 in. x 17.75 in. x 19.5 in.)
Weight:8.7 kg (19 lb)
Telephone
Telephone:RJ11C modular jacks, with
26 AWG or larger wire diameter
Ringer Equivalence Number (REN)
REN:0.4 B
Industry Canada (IC) REN:0.2
Display
Screen Dimensions:1.8 cm x 15.2 cm (0.7 in. x
6.0 in.) dot matrix LCD, 5 x 7
dots per character. Shows two
separate lines, 40 characters per
line.
Indicators:LED display section indicates
receiver status and power.
Inputs and Outputs
For Automation Computer
Connection:
One RS-232 interface port COM3
Electrical
Power Requirements
AC Nominal Operating Range:120 V or 230 V
AC Maximum Operating Range:100 VAC to 120 VAC, 220 VAC
to 230 VAC, 50 Hz or 60 Hz,
2.5 A maximum
Standby Power:Uninterruptible power supply
(UPS) containing a sealed leadacid battery, 12 V, 7 Ah to 18 Ah
Current Requirements
One Line Card Installed:Battery: 800 mA
UPS AC Standby: 350 mA
For Each Additional Line Card or
Terminal Card Pair:
One Network Communications
Card Installed:
Battery: 210 mA
UPS AC Standby: 35 mA
Battery: 10 mA
UPS AC Standby: 10 mA
Mechanical
Automation Outputs
Automation Outputs:SIA mode
6500 mode
For External Serial Printer, PC,
Modem, or Network Connection:
For Parallel Printer Connection:One parallel printer port
Number of Programmable Inputs:Two (wire harness included)
Number of Programmable
Outputs:
Optional Input
For Optional Network
Communications Expansion:
One RS-232 interface port COM4
Two (wire harness included)
One RS-232 interface port COM1
Environmental
Temperature (Operating):0°C to 50°C
(+32°F to +122°F)
Trademarks
Trademark names are used throughout this document.
In most cases, these designations are claimed as
trademarks or registered trademarks in one or more
countries by their respective owners. Rather than
placing a trademark symbol in every occurrence of a
trademark name, Bosch Security Systems, Inc. uses
the names only in an editorial fashion and to the
benefit of the trademark owner with no intention of
infringing the trademark.
Microsoft, Windows, and Windows NT are registered trademarks of
Microsoft Corporation in the United States and/or other countries.
Ordering information
Conettix D6600 Communications Receiver/Gateway
Supports communications through PSTN and/or LAN/
WAN. Supports 32 telephone lines, 3200 network
accounts, two-way audio, caller ID, ANI, and DNIS.
Order number D6600
Accessories
3200 Account Conettix IP Security Key (LPT)
Designed for parallel ports. Allows each Conettix
Communications Receiver/Gateway to support a
maximum of 3200 IP accounts.
Order number D6201
3200 Account Conettix IP Security Key (USB)
Allows each Conettix Communications Receiver/
Gateway to support a maximum of 3200 IP accounts.
Designed for USB ports.
Order number D6201-USB
500 Account Conettix IP Security Key (USB)
Allows each Conettix Communications Receiver/
Gateway to support 500 IP accounts. Designed for
USB ports.
Order number D6201-500-USB
P6602 Input and Output Cable
Supports use of input and output lines for Conettix
receivers.
Order number P6602
P6603 Acknowledgement Button
Spare acknowledgement button for Conettix D6600
Communications Receiver/Gateway.
Order number P6603
Conettix ITS-D6686-UL Ethernet Network Adapter
Order number ITS-D6686-UL
Conettix ITS-D6686-INTL Ethernet Network Adapter
Provides a 10/100 Base T network interface
connection for IP account monitoring and central
station automation with Conettix D6600
Communications Receiver/Gateway. Supports IPv6/
IPv4 dual stack and up to 256-bit AES encryption.
Order number ITS-D6686-INTL
Software Options
Conettix D6200CD CD‑ROM
Provides software for programming and operating
Conettix receivers. Includes PDF documentation for
hardware and software relating to the Conettix
Communications Receiver/Gateway.
Order number D6200CD
Conettix D6610 CPU Line Card
CPU card for Conettix D6600 Communications
Receiver/Gateway.
Order number D6610
Conettix D6615 CPU Terminator Card
Provides a shielded interface between the Conettix
D6610 CPU Line Card and external connections to
automation database computers and printers.
Order number D6615
Conettix D6641 Telephone Line Card
Answers and decodes signals from up to four
telephone lines using advanced digital signal
processing technology.
Order number D6641
Conettix D6645 Telephone Line Terminator Card
Provides isolation and transient suppression to the
Conettix D6641 Telephone Line Card.
Order number D6645
Conettix D6672 Com 1 Expansion Kit
Creates a third serial port on the Conettix D6600
Communications Receiver/Gateway. Provides a DB9
male connector and transient protection.
Order number D6672
P6601 Battery Cable
Connects a 12 VDC power source to the Conettix
D6600 Communications Receiver/Gateway.
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd.
203 Building, No. 333 Fuquan Road
North IBP
Changning District, Shanghai
200335 China
Phone +86 21 22181111
Fax: +86 21 22182398
www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division
Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil
Phone: +55 19 2103 2860
Fax: +55 19 2103 2862
latam.boschsecurity@bosch.com
www.boschsecurity.com