Blodgett RE User Manual

ZEPHAIRE-G
CONVECTION OVEN
INSTALLATION -- OPERATION -- MAINTENANCE
ZEPHAIRE-G
MANUEL D’INSTALLATION -- FONCTIONNEMENT -- ENTRETIEN
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone (800) 331-5842, (802) 860-3700 Fax: (802)864-0183
PN 90139 Rev J (6/01)
E 2001 --- G.S. Blodgett Corporation
IMPORTANT
WARNIN G:IMPROPERINSTALLATION,ADJUSTMENT,ALTERATION,SERVICEOR MAINTENAN C ECAN CAUSEPROPERTY DAMAGE,INJURY ORDEATH .READTHE INSTALLA TION,OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT
AVERTI SSEMEN T: UNE INST A LL ATION, UN AJUSTEMENT, UNE ALTÉRATION, UN SERVICEOU UN ENTRETIEN NON CONFORMEAUXNORMESPEUT CAUSERDES DOMMAGESÀLAPROPRIÉTE,DESBLESSURESOULAMORT. LISEZATTENTIVE­MENTLES DIRECTIVESD’INST A L LATION,D’OPÉRATI O NET D’ENTRETIENAVANT DE FAIRE L’INST A L LATION OU L’ENTRETIEN DE CET ÉQUIPEMENT.
INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS MUST BE POSTED IN A PROMINENT LOCATION. THIS INFORMATION MAY BE OBTAINED BY CONTACTING YOUR LOCAL GAS SUPPLIER.
LES INSTRUCTIONSÀ RESPECTER AU CAS OÙ L’UTILISATEUR PERÇOIT UNE ODEURDE GAZ DOIVENT ÊTRE AFFICHÉESDANSUN ENDROIT BIENVISIBLE. VOUS POUVEZ VOUS LES PROCURER AUPRÈS DE VOTRE FOURNISSEUR DE GAZ LOCAL.
FORYOURSAFETY
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
AVERTISSEMENT
Ne pas entreposer ni utiliser de l’essence ni d’autres vapeurs ou liquides inflam­mables dans le voisinage de cet appariel, ni de tout autre appareil.
The information contained in thismanual is importantforthe properinstallation, use,and maintenanceofthisoven. Adherenceto theseproceduresand instruc­tions will result in satisfactory baking results and long, trouble free service. Please read this manual carefully and retain it for future reference.
Les informationsdonnées dans le présent manuel sont importantes pour installer, utiliseret entretenir correctementce four. Le respect de ces instructio n s et procé­durespermettra d’obtenir de bonsrésultats de cuisson et une longuedurée de ser­vice sans problèmes. Veuillez lire le présent manuel et le conserver pour pouvoir vous y reporter à l’avenir.
Errors: Descriptive,typographicor pictorial errors are subjectto correction.Specifica-
tions are subject to change without notice.
Erreurs:Les erreurs de description, de typographie ou d’illustration font l’objet de
corrections. Les caractéristiques sont sujettes à modifications sans préavis.
THE REPUTATION YOU CAN COUNT ON
UNE RÉPUTATION SUR LAQUELLE VOUS POUVEZ COMPTER
Forover acentury and a half,The BlodgettOven Companyhas been building ovensand nothing but ovens. We’veset the industry’s qualitystandard forall kinds of ovens for every foodservice operation regardless of size, application or budget. In fact, no one offers more models, sizes, and oven applications than Blodgett;gas andelectric,full-size, half-size,countertop and deck, con­vection, Cook’n Hold, Combi-Ovens and the industry’s highest quality Pizza Oven line. For more information on the fullline of Blodgett ovens contact your Blodgett representative.
Celafait maintenantdessus unsiècle etdemi queBlodgettse spécialisedans la fabrication de fours. Nous avons établi les normes de qualité qui s’appli­quent dans l’industrie à tous les types de fours utilisés dans les services ali­mentaires,quelqu’en soitlataille,l’exploitationoulebudget. Enfait, nin’offre plus de modèles, de tailles et d’applications de fours que Blodgett. À gaz et électriques. De tailles différentes, sur plan de travail et superposables. Qu’il s’agisse de foursà convection,des modèles Cook’n Holdet Combi-Oven,ou de la gamme de fours à pizzas de la plus haute qualité offerte sur le marché. Pourde plus amples informations sur la gamme complète de fours Blodgett, veuillez contacter votre représentant Blodgett.
Your Service Agency’s Address: Adressedevotreagencedeservice:
Model/Modèl:
Serial Number/Numéro de série:
Your oven was installed by/ Installateur de votre four:
Your oven’s installation was checked by/ Contrôleur de l’installation de votre four:
Table of Contents/Table des Matières
Introduction
Oven Description and Specifications 2....
Oven Components 3....................
Installation
Delivery and Location 4.................
Oven Assembly 5......................
NSF Bolts 5..........................
Leg Attachment 6.....................
Caster Assembly 6....................
Double Section Assembly 7............
Oven Leveling 7......................
Ventilation 8...........................
Canopy Type Exhaust Hood 8..........
Direct Flue Arrangement 9.............
Utility Connections ---
Standards and Codes 10.................
Gas Connection 11......................
Electrical Connection 14.................
Initial Startup 15.........................
Introduction
Description et Spécifications du Four 26....
Éléments du Four 27.....................
Installation
Livraison et Implantation 28...............
Montage du Four 29.....................
Boulons NSF 29.......................
Assemblage des Pieds 30...............
Montage des Roulettes 30..............
Montage de la Section Double 31........
MiseàNiveauduFour 31...............
Ventilation 32...........................
Hotte D’évacuation Type Voûte 32.......
En Prise Directe 33.....................
Branchements de Service --- Normes et
Codes 34...............................
Branchement de Gaz 35.................
Raccordement Électrique 38..............
Mise en Marche Initiale 39................
Operation
Safety Information 16....................
Single Speed Blower 17..................
Single Speed Blower with Cavity Lights 18..
Dual Speed Blower 19...................
Dual Speed Blower with Cavity Lights 20... General Guidelines for Operating
Personnel 21............................
Suggested Times and Temperatures 22....
Maintenance
Cleaning and Preventative Maintenance 23.
Troubleshooting Guide 24................
Utilisation
Informations de Sécurité 40...............
Soufflerie Une Vitesse 41.................
Soufflerie Une Vitesse avec Lumières de
Cavité 42...............................
Soufflerie Deux Vitesses 43...............
Soufflerie Deux Vitesses avec Lumières de
Cavité 44...............................
Consignes Générales à l’Intention des
Utilasateurs 45..........................
Durées et Températures Suggérées 46.....
Entretien
Nettoyage et Entretien Préventif 47........
GuidedeDétectiondesPannes 48........
Introduction
Oven Description and Specifications
Cooking in a convection oven differs from cooking ina conventionaldeckor rangeovensince heated air is constantly recirculated over the product by afan inan enclosedchamber.Themovingaircon­tinually strips away the layer of cool air surround­ingthe product, quicklyallowing theheat to pene­trate. The result is a high quality product, cooked at alower temperature ina shorter amount of time.
Blodgettconvectionovensrepresent thelatestad­vancement in energy efficiency, reliability, and ease of operation. Heat normally lost, is recircu­lated within the cooking chamber before being vented from the oven: resulting in substantial re­ductions in energy consumption and enhanced oven performance.
AirFlowPatternforBlodgettConvectionOvens
Figure 1
GAS SPECIFICATIONS
Natural Gas Propane Gas
US Units SI Units US Units SI Units
Heating Value 1000 BTU/cu. ft. 37.3 MJ/m Specific Gravity (air=1.0) 0.63 0.63 1.53 1.53 Gas Manifold Pressure 3.5” W.C. .87 kPa 10” W.C. 2.49 kPa Oven Input 60,000 BTU/hr 17.6 kW 60,000 BTU/hr 17.6 kW Main Burner Orifice Size .1065” dia. 2.7 mm .0635” dia. 1.6 mm Pilot Burner Orifice Size .021” dia. .53 mm .014” dia. .36 mm
GAS SPECIFICATIONS -- Zephaire G-L for Australia
Oven Input --- 63 MJ/h --- 63 MJ/h Main Burner Orifice Size .1065” dia. 2.7 mm .0635” dia. 1.6 mm
3
2550 BTU/cu. ft. 95.0 MJ/m
3
2
Introduction
Oven Components
Combustion Cover --- provides access to the
combustion compartment on gas ovens. Combustion Compartment --- contains combus-
tion burners on gas ovens. Combustion Burners --- provide heat to the bak-
ing chamber on gas ovens. Control Panel --- containswiringandcomponents
to control the oven operation. Oven Racks --- five racks are provided standard.
Additional racks are available.
Oven
Lights
Blower
Wheel
Convection
Motor
Rack Supports --- hold oven racks. BlowerWheel Cover --- locatedontheback interi-
or wall of the oven. Protects the blower wheel. Blower Wheel --- spins to circulate hot air in the
baking chamber. Convection Motor --- provides power to turn the
blower w h eel. Oven Lights --- provide lighting inside the baking
compartment.
Blower
Wheel Cover
Rack Support
Combustion
Cover
Control Panel
Oven Rack
Combustion
Burners
Figure 2
3
Installation
Delivery and Location
DELIVERY AND INSPECTION
All Blodgett ovens are shipped in containers to preventdamage. Upondelivery ofyour new oven:
D
Inspecttheshippingcontainerforexternaldam­age. Any evidenceof damage should be noted onthe deliveryreceipt which mustbe signed by the driver.
D
Uncrate the oven and check for internal dam­age. Carriers will accept claims for concealed damage if notified within fifteendays of delivery and the shipping container is retained for in­spection.
The Blodgett Oven Company cannot assume responsibility for loss or damage suffered in transit. The carrier assumed full responsibility for delivery in good order when the shipment was accepted. We are, however, prepared to assist you if filing a claim is necessary.
OVEN LOCATION
The well planned and proper placement of your oven will result in long term operator convenience and satisfactory performance.
The following clearances must be maintainedbe­tween the ovenand any combustible or non-com­bustible construction.
D
Oven body right side --- 6” (15 cm)
D
Oven body left side --- 6” (15 cm)
D
Oven body back --- 6” (15 cm)
D
Oven body bottom --- 4.5” (11.4 cm)
Thefollowingclearancesmustbe availablefor ser­vicing.
D
Oven body sides --- 12” (30 cm)
D
Oven body back --- 12” (30 cm)
NOTE: Ongasmodels, routineservicingcanusu-
ally be accomplished within the limited movement provided by the gas hose re­straint. If the oven needs to be moved fur­ther from the wall, the gas must first be turned offand disconnected from theoven before removing the restraint. Reconnect the restraint after the oven has been re­turned to its normal position.
It is essential that an adequate air supply to the oven be maintained to provide a sufficient flow of combustion and ventilation air.
D
Place the oven in an area that is free of drafts.
D
Keeptheovenareafree andclear ofallcombus­tiblessuchas paper, cardboard,and flammable liquids and solvents.
D
Do not place the ovenon a curb base or seal to awall.Thiswill restricttheflow ofairandprevent proper ventilation. Tripping of the blower mo­tor’s thermal overload device is caused by an excessive ambient t emperature on the right side of the oven. This condition must be cor­rected to prevent permanent damage to the oven.
D
The location must provide adequate clearance for the air opening into the combustion cham­ber.
Beforemakingany utilityconnectionstothis oven, check the rating plate to be sure the oven specifi­cations are compatible with the gas and electrical services supplied for the oven.
1. Remove the combustion compartment cover. Theratingplateis attachedto theframeonthe left side of the combustion compartment.
4
Installation
Oven Assembly
NSF BOLTS
These bolts are required by NSF to block any ex­posed hole on the back of an oven. This includes:
D
any unit, single or stacked, without a back panel.
D
any holes in stacked units not used for mount­ing stacking brackets.
1. Locate the 5/16” bolts that were shipped with
the oven.
2. InstalltheboltsasshowninFigure3.
Double Stacked Units Units without back panels
Figure 3
5
Installation
Oven Assembly
LEG ATTACHMENT
1. Lay the oven on its back.
2. Align the threaded stud in each leg with the nut located inside each bottom corner of the ovenframe. Turnthe legs clockwiseand tight­en to the nearest full turn.
3. Align the two leg plate holes in each leg with thosein the ovenbottom. Secure each legus­ing two 1/2” bolts.
NOTE: If using casters see CASTER AS-
SEMBLY before proceeding.
4. Tip the oven up on the legs.
5. Levelthe ovenby screwing the adjustableleg feet in or out as necessary.
CASTER ASSEMBLY
NOTE: Install the locking casters on the front of
theoven.Installthenon-lockingcasters on the back of the oven.
NOTE: Use a gas hose restraint on all units with
casters. See page 13.
Casters for Single and Double Stacked Ovens:
1. Attach the legs as described.
2. Pry the adjustable feet out of the legs.
3. Insert one caster into each leg as shown. Tighten the lock nuts to secure the casters.
Adjustable
Leg Foot
Gas Hose
Restraint Bracket
Caster Assembly
Figure 5
6” (15 cm) Legs Shown
Figure 4
LowProfileCastersfor DoubleStackedOvens:
1. Alignthe three holes in each caster assembly plate with those in the oven bottom. Secure each caster using three 1/2” bolts.
Gas Hose Restraint Bracket
Figure 6
6
Installation
Oven Assembly
DOUBLE SECTION ASSEMBLY
NOTE: Oldstyleovens refer to units with painted ex-
posed rear angle. New style ovens refer to units with rear angle iron enclosed in steel.
The following instructions apply to stacking two new style ovens.
1. Secure the short legs to the bottom sections as described.
2. Place the upper section in position on top of the lower oven.
3. Attach the stacking brackets using the re­maining 5/16” bolts shipped with the ovens.
4. Attach the flue connector.
The following instructions apply to stacking a new styleovenonanoldstyleoven.
1. Secure the short legs to the bottom sections as described.
2. Place the upper section in position on top of the lower oven.
3. Attach the stacking brackets using the re­maining 5/16” bolts shipped with the ovens.
4. Drill a clearance hole for a 5/16” bolt in the angle iron of the old style oven. Use the holes in the stacking brackets as a pilot.
5. Attach the stacking brackets to the old style ovenwith the 5/16” bolts and nuts provided in the kit.
6. Attach the flue connector.
WARNING!! Whenstackingovensbesuretoremove
thesingleovenflueboxespriortoattach­ing three-piece connector.
OVEN LEVELING
After assembly, the oven should be leveled and moved to the operating location.
1. The oven can be leveled by adjusting the feet or casters located on the bottom of each leg.
Figure 7
7
Flue
Connector
Installation
Ventilation
On gas models the installation of a proper ventila­tionsystem cannotbe overemphasized.This sys­tem removes unwanted vapors and products of combustion from the operating area.
This oven may be vented using either:
D
A mechanically driven, canopy type, exhaust hood, or
D
A direct flue arrangement.
U.S. and Canadian installations
Refer to your local ventilation codes. In the ab­sence of local codes, refer to the Nationalventila­tion code titled, “Standard for the Installation of
Equipment for the Removal of Smoke and Grease Laden Vapors from Commercial Cooking Equip­ment”, NFPA-96-Latest Edition.
Australia and general export installations
Installationmust conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questionsregarding the proper installationand/or operation of your Blodgett oven, please contact yourlocaldistributor. If youdonot have alocaldis­tributor,please calltheBlodgettOven Companyat 0011-802-860-3700.
CANOPY TYPE EXHAUST HOOD
A mechanicallydriven, canopytype exhausthood is the preferred method of ventilation.
The hood should be sized to completelycover the equipmentplus an overhang of at least 6” (15 cm) on all sides not adjacent to a wall. The distance from the floor to the lower edgeof the hood should not exceed 7’ (2.1m).
Thetotalmakeupandexhaust airrequirementsfor hood capacity should be approximately 30 CFM
3
(.85 m
Installing the canopy hood draft diverter
Ovens ordered for hood venting are supplied with a draft diverter.Install the draft diverter as follows:
1. Placethe diverter over the flue connector with
2. Securebothends with thesheet metalscrew s
) for each oven section.
theopen areafacing the frontof the oven.See Figure 8.
provided.
Draft Diverter
WARNING: Failure to properly vent the oven can be
hazardous to the health of the operator and may result in operational problems, unsatisfactory baking and possible dam­age to the equipment.
Damage sustainedas a directresult of im­proper ventilation will not be covered by the manufacturer’s warranty.
Front of
Oven
Figure 8
8
Installation
Ventilation
DIRECT FLUE ARRANGEMENT
When the installationof a mechanically driven ex­haust hoodis impractical the oven may be vented by a direct flue arrangement.
WARNING!! It is essential that the direct flue be
installed as follows. Incorrectinstallation will result in unsatisfactory baking and oven damage.
ThefluemustbeclassBorbetterwithadiameter of6” (15 cm). Theheight of the flueshould rise6-8 ft (2-2.5 m) above the roof of the building or any proximate structure. Never direct vent the oven into a hood. The flue should be capped with a UL Listed type vent cap to isolate the unit from exter­nal environmental conditions.
Thedirectventcannotreplaceairconsumedand vented by the oven. Provisions must be made to supply the room with sufficient make-up air. Total make-up air requirements for each oven section shouldbe approximately30 CFM (.85m tion. To increase t he supply air entering the room, a ventilation expert should be consulted.
3
)persec-
Installing the draft hood
Ovensordered fordirect venting are suppliedwith a draft hood. Install the draft hood as follows:
1. Place the draft hood over the flue connector . SeeFigure9.
2. Securebothends with thesheet metalscrew s provided.
Flue
Draft Hood
Front of
Oven
Figure 9
9
Installation
Utility Connections --- Standards and Codes
THE INSTALLATION INSTRUCTIONS CON­TAINED HEREIN ARE FOR THE USE OF QUALI­FIEDINSTALLATIONAND SERVICEPERSONNEL ONLY. INSTALLATION OR SERVICE BY OTHER THAN QUALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN AND/OR INJURY TO THE OPERATOR.
Qualified installation personnel are individuals, a firm, a corporation, or a company which either in person or through a representative are engaged in, and responsible for:
D
the installation or replacement of gas piping and the connection, installation, repair or s erv­icing of equipment.
D
the installationofelectrical wiring from the elec­tric meter, main control box or service outlet to the electric appliance.
Qualified installation personnel must be experi­enced in such work, familiar with all precautions required,and havecompliedwith allrequirements of state or local authorities having jurisdiction.
U.S. and Canadian installations
Installation must conform with local codes, or in the absence of local codes, with the National Fuel
Gas Code, NFPA54/ANSI Z223.1---Latest Edition, the Natural Gas Installation Code CAN/CGA­B149.1 or the Propane Installation Code, CAN/ CGA-B149.2 as applicable.
Installation must conform with local codes, or in theabsence oflocal codes, withthe NationalElec-
trical Code, ANSI/NFPA 70---Latest Edition and/or CanadianNationalElectricCodeC22.2asapplica-
ble.
Australia and general export installations
Installationmust conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questionsregarding the proper installationand/or operation of your Blodgett oven, please contact yourlocaldistributor. If youdonot have alocaldis­tributor,please calltheBlodgettOven Companyat 0011-802-860-3700.
10
Installation
p
p
g
Gas Connection
GAS PIPING
Aproperlysized gas supplysystemis essentialfor maximum oven performance. Piping should be sized to provide a supply of gas sufficient to meet themaximumdemandof allapplianceson theline without loss of pressure at the equipment.
Example:
NOTE: BTU values in the following example are
for natural gas.
You purchase a Zephaire-G convection oven to add to your existing cook line.
1. AddtheBTUratingof yourcurrentappliances. Pitco Fryer 120,000 BTU
6 Burner Range 60,000 BTU Deck Oven 50,000 BTU Total 230,000 BTU
2. Add the BTU rating of the new oven to the to­tal.
Previous Total 230,000 BTU Zephaire-G 60,000 BTU New Total 290,000 BTU
3. Measure the distance from the gas meter to the cookline. This is the pipelength.Let’s say the pipe length is 40’ (12.2 m) and the pipe size is 1” (2.54 cm).
4. Usethe appropriate table to determine the to­tal capacity of your current gas piping.
The total capacity for this example is 320,000 BTU. Since the total required gas pressure, 290,000 BTU is less than 320,000 BTU, the current gas piping will not have to be in­creased.
NOTE: TheBTU capacitiesgiven inthe tables are
for straight pipe lengths only. Any elbows orotherfittings willdecreasepipecapaci­ties. Contactyour local gas supplier if you have any questions.
Maximum Capacity of Iron Pipe in Cubic Feet
of Natural Gas Per Hour
(Pressure drop of 0.5 Inch W.C.)
Pipe
Length (ft)
10 360 680 1400 2100 3950 20 250 465 950 1460 2750 30 200 375 770 1180 2200 40 170 320 660 990 1900 50 151 285 580 900 1680 60 138 260 530 810 1520 70 125 240 490 750 1400 80 118 220 460 690 1300 90 110 205 430 650 1220
100 103 195 400 620 1150
From the National Fuel Gas Code Part 10 Table 10-2
Maximum Capacity of Pipe in Thousands of
BTU/hr of Undiluted L.P. Gas at 11” W.C.
(Pressure drop of 0.5 Inch W.C.)
Pipe Length
(ft)
10 608 1146 3525 20 418 788 2423 30 336 632 1946 40 287 541 1665 50 255 480 1476 60 231 435 1337 70 215 404 1241 80 198 372 1144 90 187 351 1079
100 175 330 1014
From the National Fuel Gas Code Part 10 Ta ble 10-15
Nominal Size, Inches
3/4” 1” 1-1/4” 1-1/4” 2”
Outside Diameter, Inches 3/4” 1” 1-1/2”
11
Installation
Gas Connection
PRESSURE REGULATION AND TESTING
Zephaire-G ovens are rated at 60,000 BTU/Hr. (17.6kW)(63MJ)persection.Eachovenhas been adjusted at the factory to operate with the type of gas specified on the rating plate.
Inlet Pressure
Natural Propane
Min Max Min Max
W.C. 7.0 10.5 11.0 13.0 kPa 1.43 2.61 2.74 3.23 Manifold Pressure
Natural Propane
W.C. 3.5 10.0 kPa .87 2.49
D
InletPressure --- the pressure ofthegas before it reaches the oven.
D
Manifold Pressure --- the pressure of the gas as it enters the main burner(s).
D
Min - -- the minimum pressure recommended to operate the oven.
D
Max --- the maximum pressure at which the manufacturer warrants the oven’s operation.
Each oven is supplied with a regulator to maintain the propergas pressure. The regulator isessen-
tial to the proper operation of the oven and shouldnotberemoved.It ispreset toprovidethe
oven with 3.5” W.C. (0.87 kPa) for natural gas and
10.5” W.C. (2.50 kPa) for Propane at the manifold. DO NOT INSTALLAN ADDITIONAL REGULATOR
WHERE THE OVEN CONNECTS TO THE GAS SUPPL Y UNLESS THE INLET PRESSURE IS ABOVE MAXIMUM.
Prior to connecting the oven, gas lines should be thoroughly purged of all metal filings, shavings, pipedope, and other debris.Afterconnection, the ovenshould be checked for correct gaspressure.
The oven and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressuresinexcessof1/2psig(3.45kPa).
The oven must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas piping system at test pressures equal or less than 1/2 psig (3.45kPa).
Gas Connection 2.5” (64 mm)
Gas Connection 3.75” (86 mm)
Figure 10
12
Loading...