AUTOMATISMO ELETTROMECCANICO PER BARRIERA VEICOLARE
GB
ELECTROMECHANICAL CONTROL DEVICE FOR VEHICULAR BARRIERS
F
AUTOMATISME ELECTROMECANIQUE POUR BARRIERE POUR VÉHICULES
D
ELEKTROMECHANISCHER ANTRIEB FÜR FAHRZEUGSCHRANKEN
E
AUTOMATISMOS ELECTROMECANICOS PARA BARRÉRAS VEHICULAR
P
AUTOMATIZAÇÃO ELECTROMECÂNICA PARA BARREIRA VEICULAR
MOOVI 30S / 30-50 RMM
D811480 ver. 07 13-07-12
8
027908 2 8 3 8 1 8
ISTRUZIONI D’USO E DI INSTALLAZIONE
INSTALLATION AND USER’S MANUAL
INSTRUCTIONS D’UTILISATION ET D’INSTALLATION
INSTALLATIONS-UND GEBRAUCHSANLEITUNG
INSTRUCCIONES DE USO Y DE INSTALACION
INSTRUÇÕES DE USO E DE INSTALAÇÃO
Via Lago di Vico, 44
36015 Schio (VI)
Tel.naz. 0445 696511
Tel.int. +39 0445 696533
Fax 0445 696522
Internet: www.bft.it
E-mail: sales@bft.it
D811480_07
2 - MOOVI 30S-30RMM-50RMM Ver. 06
USER’S MANUALENGLISH
Thank you for buying this product. Our company is sure that you will be
more than satised with the performance of the product. This product is
supplied with a “WARNINGS” leaet and an “INSTRUCTION MANUAL”.
These should both be read carefully as they provide important information
about safety, installation, operation and maintenance. This product complies
with recognised technical standards and safety regulations. We declare that
this product is in conformity with the following European Directives: 89/336/
CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.
1) GENERAL OUTLINE
Compact electromechanical barrier suitable for limiting private areas, parkings, access areas for vehicles only. Available for passageways from 3 to 5
metres. Adjustable electromechanical limit devices ensuring a correct stop
position for the boom. In case of intensive use, a thermal sensor activates
the cooling fan.
The emergency release device for manual manoeuvre is controlled by a
personalised key lock.
The actuator is always supplied for left-hand side tting. However, when necessary, the opening direction can be reversed by means of simple operations.
The CBO mod. foundation base (on request) makes barrier installation easier .
Appropriate ttings make it easy to install accessories without needing to
drill any holes.
WARNING! The barrier must be exclusively used for vehicles to
drive through. Pedestrians must not walk within the operator
manoeuvring area. An appropriate pedestrian passageway must be
provided for.
2) EMERGENCY RELEASE (Fig.1)
The emergency release allows the bar to be manoeuvred manually. It is
activated from the outside of the box by inserting the personalised key into
the lock placed under the bar and rotating it anticlockwise by 180°.
WARNING! When an actuator without bar needs to be released, ensure
that the balancing spring is not compressed (bar in the opening position).
3) USE OF AUTOMATION
As automation can be remotely controlled and therefore not within sight, it
is essential to frequently check that all safety devices are perfectly efcient.
WARNING! In case of any malfunction in the safety devices, take immediate
action and require the assistance of a specialised technician.
It is recommended to keep children at a safe distance from the automation
eld of action.
4) SCRAPPING
Materials must be disposed of in conformity with the current regulations. In
case of scrapping, the automation devices do not entail any particular risks
or danger. In case of recovered materials, these should be sorted out by
type (electrical components, copper, aluminium, plastic etc.).
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product features unchanged, at any time and without undertaking to update the
present publication.
D811480_07
Fig. 1
4 - MOOVI 30S-30RMM-50RMM Ver. 06
INSTALLATION MANUAL
ENGLISH
Thank you for buying this product. Our Company is sure that you will be
D811480_07
more than satised with the performance of the product. This product is
supplied with a “WARNINGS” leaet and an “INSTRUCTION MANUAL”.
These should both be read carefully as they provide important information about safety, installation, operation and maintenance. This product
complies with recognised technical standards and safety regulations. We
declare that this product is in conformity with the following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.
1) GENERAL OUTLINE
Compact electromechanical barrier suitable for limiting private areas,
parkings, access areas for vehicles only. Available for passageways
from 3 to 5 metres. Adjustable electromechanical limit devices ensuring
a correct stop position for the boom. In case of intensive use, a thermal
sensor activates the cooling fan.
The emergency release device for manual manoeuvre is controlled by a
personalised key lock.
The actuator is always supplied for left-hand side tting. However, when
necessary, the opening direction can be reversed by means of simple
operations.
The CBO mod. foundation base (on request) makes barrier installation
easier.
Appropriate ttings make it easy to install accessories without needing
to drill any holes.
The LEO-MV-D control panel is supplied by the manufacturer with standard
setting. Any alteration must be set by means of the incorporated display
programmer or by means of Universal palmtop programmer. The Control
unit completely supports the EELINK protocol, including the programmer
self-supply from the control unit.
Its main characteristics are:
- Closing / opening limit-switch inputs
- Separate inputs for safety devices
- Clock input
- Serial protocol connection input
- Incorporated radio receiver
The board is provided with a terminal board which can be pulled out for
easier maintenance or replacement. The board is supplied with a series
of pre-wired jumpers to facilitate the installer’s work.
The jumpers relate to the following terminals: 21-23, 21-24 and 21-30. If the
above-mentioned terminals are in use, remove their respective jumpers.
2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
• The “Warnings” leaet and “Instruction booklet” supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children’s reach.
• Keep the instructions together with the technical brochure for future
reference.
• This product was exclusively designed and manufactured for the use
specied in the present documentation. Any other use not specied
in this documentation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specied in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with the
following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC
and subsequent amendments. As for all non-EEC countries, the abovementioned standards as well as the current national standards should
be respected in order to achieve a good safety level.
• The Company declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.
• The installation must comply with the provisions set out by the following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and
subsequent amendments.
• Disconnect the electrical power supply before carrying out any work
on the installation. Also disconnect any buffer batteries, if tted.
• Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
• Check that a differential switch with a 0.03A threshold is tted just
before the power supply mains.
• Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with
an earth terminal.
• Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing,
conveying and shearing, according to and in compliance with the applicable directives and technical standards.
• Position at least one luminous signal indication device (blinker) where
it can be easily seen, and x a Warning sign to the structure.
• The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers’ components
are used.
• Only use original parts for any maintenance or repair operation.
• Do not modify the automation components, unless explicitly authorised
by the company.
• Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
• Do not allow persons or children to remain in the automation operation
area.
• Keep radio control or other control devices out of children’s reach, in
order to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualied
personnel.
• Anything which is not expressly provided for in the present instructions,
is not allowed.
• Installation must be carried out using the safety devices and controls
Impact reaction:
Limit devices:
Manual manoeuvre:
Maximum no. manoeuvres in 24h (peak):
Working temperature:
Degree of protection:
Operator weight (without boom):
Dimensions:
(*) Special supply voltages available on request.
Limiting devices:
Manual manoeuvre:
No. manoeuvres in 24 hour:
Working temperature:
Degree of protection:
Actuator weight (without bar):
Dimensions:
(*) Special power voltages available on request.
- MOOVI GA. Movable rod for boom rest (Only for MOOVI 50 RMM)
- MOOVI GAMA. Movable cushioned rod for boom rest (Only for MOOVI
30/50 RMM).
- SB. Skirt already assembled to the boom (Only for MOOVI 30/50
RMM).
- Safety edgeBIR
- MOOVI LIGHT. Light kit for booms from 3m to 4.5m
- MOOVI LIGHT 1. Light kit for booms from 5m to 6m
- MOOVI PCA. Lower or upper boom covering contour
- ELL 3/5
- AQG3 - AQG5
- GTO AQG -GTO A TG
- ATG3 - ATG5 - ATG6
For further information about installation and use of the accessories, make
reference to their respective instruction manuals.
5) FOUNDATION PLATE (Fig.2)
- Prepare a foundation hole suitable for the particular kind of ground.
- Layout several raceways for the electric cables to pass through.
- Position the screws supplied with the CBO mod. base into the 4 xing
holes with the thread facing upwards. Weld the 4 screw heads to the
base and protect the welds with rust preventer. Position the base so
that it protrudes about 20mm from the oor (g.2).
- Fill the hole with concrete, checking the position of the base in both
directions by means of a level, and let the cement harden.
6) FITTING OF THE ACTUATOR
WARNING! The barrier must be exclusively used for vehicles to
drive through. Pedestrians must not walk within the operator
manoeuvring area. An appropriate pedestrian passageway must be
provided for.
The passageway must be suitably indicated by means of the warning
signs illustrated in Fig.10.
WARNING: before opening the door, make sure that the spring has
been unloaded (rod at 43°). The door of the box must face the inside of
the property. When standing in the middle of the passageway, if the box
is on the left the barrier opens to the left, and if the box is on the right the
barrier opens to the right.
The actuator is always supplied for left-hand side tting.
6.1) Left-hand tting
- Fix the operator to the foundation base and secure it by means of nuts
M12 (g.4 ref.1). The door of the box must face towards the inside of the
property.
- The upper surface of the operator is slightly tilted so as to prevent any
rain water from being trapped there. Therefore use a side surface to
check correct positioning by means of a level (g.2).
- The installation of the MOOVI PRM antishearing Kit (optional) is easier
when carried out before tting the boom to the operator.
Make reference to Fig.18 and paragraph 6.4 for correct tting of the
MOOVI PRM Kit, then proceed to t the boom.
- Fit the boom in its opening position (vertical) as indicated in g.3, ref.7.
The operator balancing is pre-calibrated for the nominal boom in the
opening position (balancing spring stretched).
- Position the cover closing element (g.3 ref.10) on the boom, as indicated in g. 3. After positioning, drill part 10 and boom using a 2 mm
bit. Insert the screw supplied.
- Fix the boom using the bracket (g.3 ref.4) and the screws and washers supplied as standard, then x the protection cover (g.3 ref.8)
and nally the screw cover (g.3 ref.9). Close the protection cover by
making the closing element slide over the boom (g.3 ref.10).
WARNING! The boom must be positioned so as to have the double
contour facing down (g.3 ref.11).
- Balance the boom as described in relevant paragraph 7.
6.2) Right-hand tting
Some internal members need to be moved, with reference to g. 4 and
the following procedure:
A) Fix the box to the foundation base and lock it in position using M12
nuts.
B) Ensure that the balancing spring is in the opening position (stretched
spring - g.5).
C) Completely slacken the spring stretcher (g.4/ref. 2) until the screw
(g. 4/ref.3) anchoring it to the bottom of the box can be removed.
D) Remove the bar locking bracket (g.4/ref.4) and slacken the screw
(g. 4/ref.5) by means of a CH19 socket spanner until the lever can
be rota-ted (g.4/ref.6).
E) Rotate the lever (g.4/ref.6) by 180° and fasten it into the correct posi-
tion.
F) Tighten the tie rod (g. 4/ref.5) blocking the lever (g.4/ref.6) by means
of a torque wrench set at about 80 N/m.
G) Bring the release key (g.6) to the manual operation position and
manually rotate the lever (g.4/ref.6) downwards by 90° (g.7) so as
to bring the barrier to the right-hand opening position.
H) Lock the spring stretcher (g.4/ref.2) into position (g.4/ref.Dx) with
the screw and self-locking nut.
I) Adjust the spring stretcher (g.4/ref.2) until the spring comes under
tension.
L) Ret and partially x the U bolt (g.4/ref.4) holding the bar to the actua-
tor in the opening position.
M) The installation of the MOOVI PRM antishearing Kit (optional) is easier
when carried out before tting the boom to the operator.
Make reference to Fig.18 and paragraph 6.4 for correct tting of the
MOOVI PRM Kit, then proceed to t the boom. Fit the boom in its
opening position (vertical) as indicated in g.3, ref.7. The operator
balancing is pre-calibrated for the nominal boom in the opening position (balancing spring stretched).
Position the cover closing element (g.3 ref.10) on the boom, as indi-
cated in g. 3. After positioning, drill part 10 and boom using a 2 mm
bit. Insert the screw supplied.
Fix the boom using the bracket (g.3 ref.4) and the screws and wash-
ers supplied as standard, then x the protection cover (g.3 ref.8)
and nally the screw cover (g.3 ref.9). Close the protection cover by
making the closing element slide over the boom (g.3 ref.10).
WARNING! The boom must be positioned so as to have the double
contour facing down (g.3 ref.11).
N) Carry out bar balancing as described in paragraph 7.
O) Invert the limit switch connections and the motor drive connections
insi-de the control unit (Fig.19), with reference to the instructions regarding the existing control unit. Fig.8 shows a diagram highlighting the
connections to be inverted.
6.3) Fitting of the metal mass detector device
A DIN bar, which allows the DIN module to be connected, is tted to the
versions suitable for the use of a mass detector. For connection, refer
to the relevant instruction manual. In the case where the bar balancing
device hinders the adjustment of this device (left-hand barrier), remove it
from its socket, carry out the adjustment and then reposition it.
6.4) Fitting of MOOVI PRM antishearing Kit (Fig.16)
1) Remove the rubber plugs.
2) Join two pivots “P” to antishearing plate “L” so as to obtain a single
body.
3) Fix the plate to the box by putting screw M6x20 through the central
threaded hole in the box.
4) Fix rotation lock screw M6x10 through the side threaded hole in the
box.
5) The antishearing plate is to be positioned on the boom opening, the
lock screw through the remaining hole.
6) During subsequent tting of the cover, the plate must be inserted
between two guide pivots “D” xed by means of screws C.
Having completed the tting procedure, check that the antishearing plate
operates correctly. When the barrier is lifted, it must be in the position
indicated in Fig.16, ref.7; when the barrier is being closed, the plate must
follow the boom movement until it reaches the position indicated in Fig.16,
ref.8.
6.5) Assembling the ashing light RADIUS B LTA230 R1/
RADIUS B LTA 230 R2.(FIG.23)
- Complete assembly and wiring as directed in instructions provided for
RADIUS B LTA230 R1/ RADIUS B LTA230 R2.
6.6) Photocell tting (Fig. 24)
The photocell can be installed on the MOOVI barrier as follows:
1- By directly xing the CELLULA 130 photocell to the side of the barrier
(Fig. 24 “A”)
2- By fastening the MOOVI 130 photocell post to one of the front ttings
(Fig. 24 ”B”)
A) Cellula 130 tting
1) Remove the protection cover positioned on the barrier.
2) Lay the wiring needed for photocell connection.
3) Fit the photocell as shown in Fig. 24 A by means of the appropriate
screws.
Refer to the instruction sheet for Cellula 130 for further information.
B) MOOVI 130 post tting
1) Remove the protection cover positioned on the barrier.
2) Lay the wiring needed for photocell connection.
D811480_07
18 - MOOVI 30S-30RMM-50RMM Ver. 06
INSTALLATION MANUAL
ENGLISH
3) Fit post “F” and protection frame “G” as shown in Fig. 24B. The post
D811480_07
is fastened from inside the barrier by means of 3 screws (supplied).
4) Fit the photocell to the post, as shown in the instruction sheet for Cellula 130.
Refer to the instruction sheet for Cellula 130 for further information.
6.7) Moovi accessories: boom length limits and balancing (Fig.25)
6.7.1) Moovi 30RMM and Moovi 50RMM
All barriers belonging to the MOOVI series are equipped with a hooking
bracket with 3 securing points located on the device for boom balancing
(Fig. 25 - ref. A points A-B-C).
The ideal securing point for correct balancing of the boom must be
chosen according to the barrier type and to the length of the boom and
accessories installed.
Tab.1 of Fig.25 shows the weight expressed in kgs by linear meter (kg/m)
for each accessory.
When the supporting leg Moovi GA/GAMA is used, it is necessary to
calculate the arbitrary weight in Kg/m, using the following formula:
Kg/m = 1,2/L
where L stands for the length of the boom.
Then proceed as follows:
1) Sum up the total linear weight of the accessories installed (including
boom weight).
2) Find the crossing point between the length of the boom and the total
weight of the accessories on the diagram, making reference to the
MOOVI model.
3) The point found in this way will indicate the correct hooking point (A-
B-C).
Example
MOOVI 50 with:
(boom measuring 4,0m + BIR + GAMA +1PCA).
(1,028+0,510+(1,2/4,0)+0,160)= 1,97
The crossing point between value 1,97 and boom length equal to 4,0 is
within the “A” area of MOOVI 50 graph. “A” hooking point will therefore
be suitable for correct boom balancing.
Calibrate the spring as described in paragraph 7.
WARNING!:
The securing points marked with A and B can be used with MOOVI
50RMM only.
The securing point marked with C can be used with MOOVI 30S/30RMM
only.
If the point found is within the crossed area that means that installation
is not possible and it is necessary to shorten the boom or reduce the
number of accessories.
If no accessory is used, only use the weight of the “PA” boom to nd the
securing point.
6.7.2) Moovi 30S
For Moovi 30S model, observe the following:
Max. boom length: 3m
Hooking point: C
Accessories that can be used without shortening the boom: BIR - PCA
- Moovi Light
Accessories that cannot be used: GA/GAMA – SB
7) BAR BALANCING (Fig.9)
- Activate the emergency release (g.14).
- Position the bar at about 45° (g.9). The bar must remain still.
- If the bar tends to open, unload the spring by operating on the “T” tie
rod.
- If the bar tends to close, load the spring by operating on the “T” tie rod.
- In both cases, load or unload the spring until the bar remains still at
about 45°.
- Reset the motorised operation by rotating the release key to the op-
posite direction (g.14).
WARNING! During the closing operation, the balancing spring must never
be reduced to a pack (be totally compressed). Fig.9 indicates the position
where the minimum value of the compressed spring is measured with the
rod in the opening (vertical bar) position.
8) ELECTRICAL INSTALLATION SET-UP
WARNING: before opening the door, make sure that the spring has
been unloaded (rod at 43°). Set up the electrical installation (g. 10) with
reference to the current regu-lations for electrical installations CEI64-8,
IEC364, in conformity with HD384 and other national standards. Keep
the mains power supply con-nections denitely separate from the service
connections (photocells, elec-tric edges, control devices etc.).
Warning! For connection to the mains, use a multipolar cable having
minimum 3x1.5mm
2
cross section and complying with the previously
mentioned regulations (for example, if the cable is not protected, it
must be at least equal to H07 RN-F, whereas if it is protected it must
be at least equal to H07 VV-F with a 3x1.5 sq mm
2
cross section).
Connect the control and safety devices in conformity with the previously
mentioned installation standards. Fig.10 shows the number of connections
and section for a 100m length of power supply cables; for greater lengths,
calculate the section for the true automation load. When the auxiliary
connections exceed 50-metre lengths or go through critical disturbance
areas, it is recommended to decouple the control and safety devices by
means of suitable relays.
The main automation components are (g.10):
Type-approved adequately rated omnipolar circuit-breaker with
I)
at least 3,5 mm contact opening, provided with protection against
overloads and short circuits, suitable for cutting out automation
from the mains. Place, if not al ready installed, a type-approved
differential switch with a 0.03A threshold just before the automation system.
Control panel and incorporated receiver.
QR)
S) Key selector.
AL) Blinker with tuned antenna.
M) Actuators.
A) Bar.
F) Rest fork.
CS) Electric edge.
CC) Edge control.
Ft,Fr) Pair of photocells.
CF) Photocell post.
T) 1-2-4 channel transmitter.
RMM) Inductive metal mass detector.
LOOP) Mass detector loops.
10) TERMINAL BOARD CONNECTIONS (Fig.19)
WARNING – During the wiring and installation operations, refer to the
current standards as well as principles of good technical practice.
The cables must be tied by additional fastening next to the terminals, by
means of clips for example.
All the operator wiring operations must be carried out by qualied personnel.
10-11 Output 24V~ 1A max – power supply for photocells or other
devices.
12-13 Gate-open warning light output (24V 3W max)
JP4 Barrier status output
20-18 Closed Contact with barrier raised
20-19 Closed Contact with barrier lowered
Contact switching for barrier status control.
To be used in Parky systems.
Encoder connection
JP5
WARNING! The maximum length of the connection cable of
the encoder should not exceed 3.00 mt.
JP8
21-22 Open-Close button (N.O. Start), key selector.
21-23 Block button (N.C. Stop). If not used, leave jumped.
21-24 Photocell input (N.C.). If not used, leave jumped.
21-25 Opening limit switch connection (N.C. SWO). If not used,
leave jumped.
21-26 Closing limit switch connection (N.C. SWC). If not used, leave
jumped.
MOOVI 30S-30RMM-50RMM Ver. 06 - 19
ENGLISH
INSTALLATION MANUAL
21-27 Not used
21-28 Open-Button connection (N.O. Open)
21-29 Close-Button connection (N.O. Close)
21-30 Rubber edge connection (N.C.). If not used, leave jumped.
21-31 Connection of clock input (N.O.). If the contact connected is
JP9
32 Photocell check input (PHOT FAULT) (see Fig. 19)
33 Electric edge check input (EDGE FAULT) (see Fig. 19)
38-39 Antenna input for radio-receiver (38 signal - 39 braid). Cable
11) PROGRAMMING
The control panel provided with a microprocessor is supplied with function parameters preset by the manufacturer, suitable for standard instal-
lations. The predened parameters can be altered by means of either
the incorporated display programmer or Universal palmtop programmer.
In the case where programming is carried out by means of Universal palmtop
programmer, carefully read the instructions relating to Universal palmtop
programmer, and proceed in the following way.
Connect the Universal palmtop programmer to the control unit through the
UNIFLAT accessory (See g. 20). Enter the “CONTROL UNITS” menu,
and the “PARAMETERS” submenu, then scroll the display screenfuls using the up/down arrows, and set the numerical values of the parameters
listed below.
For the function logics, refer to the “LOGIC” submenu.
In the case where programming is carried out by means of the incorporated
programmer, refer to Fig. A and B and to the “conguration” paragraph.
12) CONFIGURATION
The display programmer is used to set all the LEO MV D control panel
functions.
The programmer is provided with three pushbuttons for menu scrolling
and function parameter congurations:
+ menu scrolling/value increment key
- menu scrolling/value reduction key
OK Enter (conrm) key
The simultaneous pressure of the + and – keys is used to exit the active
menu and move to the preceding menu.
If the + and – keys are pressed simultaneously at the main menu level
(parameters, logics, radio, language, autosetting), programming is exited
and the display is switched off (the OK message is displayed).
The modications made are only set if the OK key is subsequently pressed.
When the OK key is pressed for the rst time, the programming mode
is entered.
The following pieces of information appear on the display at rst:
- Control unit Software version
- Number of total manoeuvres carried out (the value is expressed in
thousands, therefore the display constantly shows 0000 during the
rst thousand manoeuvres)
- Number of manoeuvres carried out since the latest maintenance
operation (the value is expressed in thousands, therefore the display
constantly shows 0000 during the rst thousand manoeuvres)
- Number of memorised radio control devices.
When the OK key is pressed during the initial presentation phase, the
rst menu (parameters) can be accessed directly.
Here follows a list of the main menus and the respective submenus available.
The predened parameter is shown between square brackets [ 0 ].
The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the control unit conguration procedure.
12.1) Parameter Menu (PARAM)
1 - Automatic Closing Time (TCA) [ 10s ]
Set the numerical value of the automatic closing time from 1 to 180
seconds.
2 - Slow-down Distance (Cm. rall) [ 5 ]
Set the required slow-down distance for opening and closing between
1 and 90.
NOTE: power failure, reset, or manual gate release, the control panel
carries out a complete manoeuvre at reduced speed, in order to learn
the length of stroke.
3- Alarm time (alarm. time) [ 30s ]
In the case of obstacle detection or photocell engagement, at the end
of the time set (ranging from 10s to 240s) the SCA contact is closed.
The contact is subsequently opened by the STOP command or by
triggering of the closing limit switch. Only active when the SCA Alarm
logic is set to OFF.
4- Zone (zone) [ 0 ]
open, the barrier closes and gets ready for normal operation.
If the contact is closed (N.C.), the barrier opens and remains
open until contact opening.
RG58.
Set the zone number between a minimum value of 0 and a maximum
value of 128. See paragraph 8 on “Serial connection”.
5- Slow-down torque (slud torque ) [ 99% ]
Set the motor torque value during the slow-down phase between 0%
and 99%.
6- Opening torque (open torque) [ 70% ]
Set the motor opening torque value between 1% and 99%.
7- Closing torque (cls. torque) [ 70% ]
Set the motor closing torque value between 1% and 99%.
8 - Brake (Brake) [ 52% ]
Set the required brake value between 0 and 99%, compatibly with the