BFT Moovi User Manual

I
AUTOMATISMO ELETTROMECCANICO PER BARRIERA VEICOLARE
GB
ELECTROMECHANICAL CONTROL DEVICE FOR VEHICULAR BARRIERS
F
AUTOMATISME ELECTROMECANIQUE POUR BARRIERE POUR VÉHICULES
D
ELEKTROMECHANISCHER ANTRIEB FÜR FAHRZEUGSCHRANKEN
E
AUTOMATISMOS ELECTROMECANICOS PARA BARRÉRAS VEHICULAR
P
AUTOMATIZAÇÃO ELECTROMECÂNICA PARA BARREIRA VEICULAR
MOOVI 30S / 30-50 RMM
D811480 ver. 07 13-07-12
8
027908 2 8 3 8 1 8
ISTRUZIONI D’USO E DI INSTALLAZIONE
INSTALLATION AND USER’S MANUAL
INSTRUCTIONS D’UTILISATION ET D’INSTALLATION
INSTALLATIONS-UND GEBRAUCHSANLEITUNG
INSTRUCCIONES DE USO Y DE INSTALACION
INSTRUÇÕES DE USO E DE INSTALAÇÃO
Via Lago di Vico, 44 36015 Schio (VI) Tel.naz. 0445 696511 Tel.int. +39 0445 696533 Fax 0445 696522 Internet: www.bft.it E-mail: sales@bft.it
D811480_07
2 - MOOVI 30S-30RMM-50RMM Ver. 06
USER’S MANUALENGLISH
Thank you for buying this product. Our company is sure that you will be
more than satised with the performance of the product. This product is
supplied with a “WARNINGS” leaet and an “INSTRUCTION MANUAL”. These should both be read carefully as they provide important information about safety, installation, operation and maintenance. This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Directives: 89/336/ CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.
1) GENERAL OUTLINE
Compact electromechanical barrier suitable for limiting private areas, park­ings, access areas for vehicles only. Available for passageways from 3 to 5 metres. Adjustable electromechanical limit devices ensuring a correct stop position for the boom. In case of intensive use, a thermal sensor activates the cooling fan. The emergency release device for manual manoeuvre is controlled by a personalised key lock. The actuator is always supplied for left-hand side tting. However, when neces­sary, the opening direction can be reversed by means of simple operations. The CBO mod. foundation base (on request) makes barrier installation easier .
Appropriate ttings make it easy to install accessories without needing to
drill any holes.
WARNING! The barrier must be exclusively used for vehicles to drive through. Pedestrians must not walk within the operator
manoeuvring area. An appropriate pedestrian passageway must be provided for.
2) EMERGENCY RELEASE (Fig.1)
The emergency release allows the bar to be manoeuvred manually. It is activated from the outside of the box by inserting the personalised key into the lock placed under the bar and rotating it anticlockwise by 180°. WARNING! When an actuator without bar needs to be released, ensure that the balancing spring is not compressed (bar in the opening position).
3) USE OF AUTOMATION
As automation can be remotely controlled and therefore not within sight, it
is essential to frequently check that all safety devices are perfectly efcient.
WARNING! In case of any malfunction in the safety devices, take immediate action and require the assistance of a specialised technician. It is recommended to keep children at a safe distance from the automation
eld of action.
4) SCRAPPING
Materials must be disposed of in conformity with the current regulations. In case of scrapping, the automation devices do not entail any particular risks or danger. In case of recovered materials, these should be sorted out by type (electrical components, copper, aluminium, plastic etc.).
The descriptions and illustrations contained in the present manual are not binding. The Company reserves the right to make any alterations deemed appropriate for the technical, manufacturing and commercial improvement of the product, while leaving the essential product fea­tures unchanged, at any time and without undertaking to update the present publication.
D811480_07
Fig. 1
4 - MOOVI 30S-30RMM-50RMM Ver. 06
INSTALLATION MANUAL
ENGLISH
Thank you for buying this product. Our Company is sure that you will be
D811480_07
more than satised with the performance of the product. This product is
supplied with a “WARNINGS” leaet and an “INSTRUCTION MANUAL”. These should both be read carefully as they provide important informa­tion about safety, installation, operation and maintenance. This product complies with recognised technical standards and safety regulations. We declare that this product is in conformity with the following European Direc­tives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.
1) GENERAL OUTLINE
Compact electromechanical barrier suitable for limiting private areas, parkings, access areas for vehicles only. Available for passageways from 3 to 5 metres. Adjustable electromechanical limit devices ensuring a correct stop position for the boom. In case of intensive use, a thermal sensor activates the cooling fan. The emergency release device for manual manoeuvre is controlled by a personalised key lock.
The actuator is always supplied for left-hand side tting. However, when
necessary, the opening direction can be reversed by means of simple operations. The CBO mod. foundation base (on request) makes barrier installation easier.
Appropriate ttings make it easy to install accessories without needing
to drill any holes. The LEO-MV-D control panel is supplied by the manufacturer with standard
setting. Any alteration must be set by means of the incorporated display programmer or by means of Universal palmtop programmer. The Control unit completely supports the EELINK protocol, including the programmer self-supply from the control unit. Its main characteristics are:
- Closing / opening limit-switch inputs
- Separate inputs for safety devices
- Clock input
- Serial protocol connection input
- Incorporated radio receiver The board is provided with a terminal board which can be pulled out for
easier maintenance or replacement. The board is supplied with a series of pre-wired jumpers to facilitate the installer’s work. The jumpers relate to the following terminals: 21-23, 21-24 and 21-30. If the above-mentioned terminals are in use, remove their respective jumpers.
2) GENERAL SAFETY WARNING! An incorrect installation or improper use of the product can cause damage to persons, animals or things.
• The “Warnings” leaet and “Instruction booklet” supplied with this product should be read carefully as they provide important information about safety, installation, use and maintenance.
• Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene bags out of children’s reach.
• Keep the instructions together with the technical brochure for future
reference.
• This product was exclusively designed and manufactured for the use specied in the present documentation. Any other use not specied
in this documentation could damage the product and be dangerous.
• The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specied in the present documentation.
• Do not install the product in explosive atmosphere.
• The construction components of this product must comply with the
following European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments. As for all non-EEC countries, the above­mentioned standards as well as the current national standards should be respected in order to achieve a good safety level.
• The Company declines all responsibility for any consequences result­ing from failure to observe Good Technical Practice when constructing closing structures (door, gates etc.), as well as from any deformation which might occur during use.
• The installation must comply with the provisions set out by the follow­ing European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent amendments.
• Disconnect the electrical power supply before carrying out any work on the installation. Also disconnect any buffer batteries, if tted.
• Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
• Check that a differential switch with a 0.03A threshold is tted just
before the power supply mains.
• Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an earth terminal.
• Fit all the safety devices (photocells, electric edges etc.) which are
needed to protect the area from any danger caused by squashing, conveying and shearing, according to and in compliance with the ap­plicable directives and technical standards.
• Position at least one luminous signal indication device (blinker) where it can be easily seen, and x a Warning sign to the structure.
• The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers’ components are used.
• Only use original parts for any maintenance or repair operation.
• Do not modify the automation components, unless explicitly authorised
by the company.
• Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
• Do not allow persons or children to remain in the automation operation
area.
• Keep radio control or other control devices out of children’s reach, in
order to avoid unintentional automation activation.
• The user must avoid any attempt to carry out work or repair on the automation system, and always request the assistance of qualied
personnel.
• Anything which is not expressly provided for in the present instructions,
is not allowed.
• Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
3) TECHNICAL SPECIFICATIONS
MOOVI 30S
Power supply:
Absorbed power: ............................................................................300W
Motor: Capacitor: Absorption: Insulation class: Ventilation intervention temperature: Circuit-breaking intervention temperature: Reduction gear lubrication:
Max torque:.....................................................................................72Nm
Minimum opening time:
Boom (aluminium) length:.......................................................... 3m max.
Impact reaction: Limit devices: Manual manoeuvre: Maximum no. manoeuvres in 24h (peak): Working temperature: Degree of protection: Operator weight (without boom): Dimensions: (*) Special supply voltages available on request.
MOOVI 30 RMM - MOOVI 50 RMM
Power supply:
Absorbed power: ............................................................................300W
Motor: Capacitor: Absorption: Insulation class: Ventilation intervention temperature: Circuit-breaker intervention temperature: Reduction gear lubrication:
Max torque:...................................MOOVI-30 85Nm: MOOVI-50 250Nm
Opening time: (Aluminium) bar length:
ATG6 6m max Max
Impact reaction: ......................Obstacle detection device (Encoder)
Limiting devices: Manual manoeuvre: No. manoeuvres in 24 hour: Working temperature: Degree of protection: Actuator weight (without bar): Dimensions: (*) Special power voltages available on request.
4) OPTIONAL ACCESSORIES (Fig.15)
- CBO. Foundation base
- MOOVI PRM. Antishearing Kit
- MOOVI 130. Kit for Cellula 130 xing post
..........................................................220-230V 50/60Hz(*)
.........................................................................2800 min-1 2 poles
..........................25µF 450V (220-230V): 100µF 250V (110V)
..........................................................................0.8 A - 1.6 A
.....................................................................................F
.............................110 °C (winding)
...........130 °C (self-resetting)
.........................................Permanent grease
.................................................................. 1.5 s
.............................Obstacle detection device (Encoder)
.................................Electric, incorporated and adjustable
.....................................................Quick key release
.......................................3000
.....................................................-10°C to +55 C°
........................................................................IP24
................................... 356N (~35.6 kg)
..............................................................................See g. 1
.............................................................220-230V 50/60Hz
........................................................................1400 min-1, 4 poles
...............................8µF 450V (220-230V):32µF 250V (110V)
............................................................................ 0.8 A:1.6 A
.....................................................................................F
..............................110°C (winding)
..............130°C (self-resetting)
.........................................Permanent grease
...........................................MOOVI-30 4s : MOOVI-50 8s
MOOVI-30 3m max: MOOVI-50 5m max: MOOVI-50 +
............................Electric, incorporated and adjustable
.....................................................Quick key release
...........1200 (MOOVI-30) :600 (MOOVI-50)
.......................................................-10°C ÷ +55°C
........................................................................IP24
........................................ 356N (~35.6 kg)
...............................................................................See g.1
MOOVI 30S-30RMM-50RMM Ver. 06 - 17
ENGLISH
INSTALLATION MANUAL
- FAF. Fixed fork for boom rest
- MOOVI GA. Movable rod for boom rest (Only for MOOVI 50 RMM)
- MOOVI GAMA. Movable cushioned rod for boom rest (Only for MOOVI 30/50 RMM).
- SB. Skirt already assembled to the boom (Only for MOOVI 30/50 RMM).
- Safety edge BIR
- MOOVI LIGHT. Light kit for booms from 3m to 4.5m
- MOOVI LIGHT 1. Light kit for booms from 5m to 6m
- MOOVI PCA. Lower or upper boom covering contour
- ELL 3/5
- AQG3 - AQG5
- GTO AQG -GTO A TG
- ATG3 - ATG5 - ATG6
For further information about installation and use of the accessories, make reference to their respective instruction manuals.
5) FOUNDATION PLATE (Fig.2)
- Prepare a foundation hole suitable for the particular kind of ground.
- Layout several raceways for the electric cables to pass through.
- Position the screws supplied with the CBO mod. base into the 4 xing
holes with the thread facing upwards. Weld the 4 screw heads to the base and protect the welds with rust preventer. Position the base so
that it protrudes about 20mm from the oor (g.2).
- Fill the hole with concrete, checking the position of the base in both directions by means of a level, and let the cement harden.
6) FITTING OF THE ACTUATOR
WARNING! The barrier must be exclusively used for vehicles to drive through. Pedestrians must not walk within the operator
manoeuvring area. An appropriate pedestrian passageway must be provided for. The passageway must be suitably indicated by means of the warning signs illustrated in Fig.10.
WARNING: before opening the door, make sure that the spring has been unloaded (rod at 43°). The door of the box must face the inside of
the property. When standing in the middle of the passageway, if the box is on the left the barrier opens to the left, and if the box is on the right the barrier opens to the right.
The actuator is always supplied for left-hand side tting.
6.1) Left-hand tting
- Fix the operator to the foundation base and secure it by means of nuts
M12 (g.4 ref.1). The door of the box must face towards the inside of the
property.
- The upper surface of the operator is slightly tilted so as to prevent any rain water from being trapped there. Therefore use a side surface to
check correct positioning by means of a level (g.2).
- The installation of the MOOVI PRM antishearing Kit (optional) is easier
when carried out before tting the boom to the operator.
Make reference to Fig.18 and paragraph 6.4 for correct tting of the
MOOVI PRM Kit, then proceed to t the boom.
- Fit the boom in its opening position (vertical) as indicated in g.3, ref.7.
The operator balancing is pre-calibrated for the nominal boom in the opening position (balancing spring stretched).
- Position the cover closing element (g.3 ref.10) on the boom, as indi­cated in g. 3. After positioning, drill part 10 and boom using a 2 mm
bit. Insert the screw supplied.
- Fix the boom using the bracket (g.3 ref.4) and the screws and wash­ers supplied as standard, then x the protection cover (g.3 ref.8) and nally the screw cover (g.3 ref.9). Close the protection cover by making the closing element slide over the boom (g.3 ref.10).
WARNING! The boom must be positioned so as to have the double
contour facing down (g.3 ref.11).
- Balance the boom as described in relevant paragraph 7.
6.2) Right-hand tting
Some internal members need to be moved, with reference to g. 4 and
the following procedure: A) Fix the box to the foundation base and lock it in position using M12
nuts.
B) Ensure that the balancing spring is in the opening position (stretched
spring - g.5).
C) Completely slacken the spring stretcher (g.4/ref. 2) until the screw
(g. 4/ref.3) anchoring it to the bottom of the box can be removed.
D) Remove the bar locking bracket (g.4/ref.4) and slacken the screw
(g. 4/ref.5) by means of a CH19 socket spanner until the lever can be rota-ted (g.4/ref.6).
E) Rotate the lever (g.4/ref.6) by 180° and fasten it into the correct posi-
tion.
F) Tighten the tie rod (g. 4/ref.5) blocking the lever (g.4/ref.6) by means
of a torque wrench set at about 80 N/m.
G) Bring the release key (g.6) to the manual operation position and
manually rotate the lever (g.4/ref.6) downwards by 90° (g.7) so as
to bring the barrier to the right-hand opening position.
H) Lock the spring stretcher (g.4/ref.2) into position (g.4/ref.Dx) with
the screw and self-locking nut.
I) Adjust the spring stretcher (g.4/ref.2) until the spring comes under
tension.
L) Ret and partially x the U bolt (g.4/ref.4) holding the bar to the actua-
tor in the opening position.
M) The installation of the MOOVI PRM antishearing Kit (optional) is easier
when carried out before tting the boom to the operator.
Make reference to Fig.18 and paragraph 6.4 for correct tting of the
MOOVI PRM Kit, then proceed to t the boom. Fit the boom in its opening position (vertical) as indicated in g.3, ref.7. The operator
balancing is pre-calibrated for the nominal boom in the opening posi­tion (balancing spring stretched).
Position the cover closing element (g.3 ref.10) on the boom, as indi-
cated in g. 3. After positioning, drill part 10 and boom using a 2 mm
bit. Insert the screw supplied.
Fix the boom using the bracket (g.3 ref.4) and the screws and wash-
ers supplied as standard, then x the protection cover (g.3 ref.8) and nally the screw cover (g.3 ref.9). Close the protection cover by making the closing element slide over the boom (g.3 ref.10).
WARNING! The boom must be positioned so as to have the double
contour facing down (g.3 ref.11).
N) Carry out bar balancing as described in paragraph 7. O) Invert the limit switch connections and the motor drive connections
insi-de the control unit (Fig.19), with reference to the instructions regar­ding the existing control unit. Fig.8 shows a diagram highlighting the connections to be inverted.
6.3) Fitting of the metal mass detector device
A DIN bar, which allows the DIN module to be connected, is tted to the
versions suitable for the use of a mass detector. For connection, refer to the relevant instruction manual. In the case where the bar balancing device hinders the adjustment of this device (left-hand barrier), remove it from its socket, carry out the adjustment and then reposition it.
6.4) Fitting of MOOVI PRM antishearing Kit (Fig.16)
1) Remove the rubber plugs.
2) Join two pivots “P” to antishearing plate “L” so as to obtain a single body.
3) Fix the plate to the box by putting screw M6x20 through the central threaded hole in the box.
4) Fix rotation lock screw M6x10 through the side threaded hole in the box.
5) The antishearing plate is to be positioned on the boom opening, the lock screw through the remaining hole.
6) During subsequent tting of the cover, the plate must be inserted between two guide pivots “D” xed by means of screws C.
Having completed the tting procedure, check that the antishearing plate
operates correctly. When the barrier is lifted, it must be in the position indicated in Fig.16, ref.7; when the barrier is being closed, the plate must follow the boom movement until it reaches the position indicated in Fig.16, ref.8.
6.5) Assembling the ashing light RADIUS B LTA230 R1/
RADIUS B LTA 230 R2.(FIG.23)
- Complete assembly and wiring as directed in instructions provided for RADIUS B LTA230 R1/ RADIUS B LTA230 R2.
6.6) Photocell tting (Fig. 24)
The photocell can be installed on the MOOVI barrier as follows: 1- By directly xing the CELLULA 130 photocell to the side of the barrier
(Fig. 24 “A”)
2- By fastening the MOOVI 130 photocell post to one of the front ttings
(Fig. 24 ”B”)
A) Cellula 130 tting
1) Remove the protection cover positioned on the barrier.
2) Lay the wiring needed for photocell connection.
3) Fit the photocell as shown in Fig. 24 A by means of the appropriate screws.
Refer to the instruction sheet for Cellula 130 for further information.
B) MOOVI 130 post tting
1) Remove the protection cover positioned on the barrier.
2) Lay the wiring needed for photocell connection.
D811480_07
18 - MOOVI 30S-30RMM-50RMM Ver. 06
INSTALLATION MANUAL
ENGLISH
3) Fit post “F” and protection frame “G” as shown in Fig. 24B. The post
D811480_07
is fastened from inside the barrier by means of 3 screws (supplied).
4) Fit the photocell to the post, as shown in the instruction sheet for Cel­lula 130.
Refer to the instruction sheet for Cellula 130 for further information.
6.7) Moovi accessories: boom length limits and balancing (Fig.25)
6.7.1) Moovi 30RMM and Moovi 50RMM
All barriers belonging to the MOOVI series are equipped with a hooking bracket with 3 securing points located on the device for boom balancing (Fig. 25 - ref. A points A-B-C). The ideal securing point for correct balancing of the boom must be chosen according to the barrier type and to the length of the boom and accessories installed. Tab.1 of Fig.25 shows the weight expressed in kgs by linear meter (kg/m) for each accessory. When the supporting leg Moovi GA/GAMA is used, it is necessary to calculate the arbitrary weight in Kg/m, using the following formula:
Kg/m = 1,2/L
where L stands for the length of the boom. Then proceed as follows:
1) Sum up the total linear weight of the accessories installed (including
boom weight).
2) Find the crossing point between the length of the boom and the total
weight of the accessories on the diagram, making reference to the MOOVI model.
3) The point found in this way will indicate the correct hooking point (A-
B-C).
Example
MOOVI 50 with: (boom measuring 4,0m + BIR + GAMA +1PCA). (1,028+0,510+(1,2/4,0)+0,160)= 1,97 The crossing point between value 1,97 and boom length equal to 4,0 is within the “A” area of MOOVI 50 graph. “A” hooking point will therefore be suitable for correct boom balancing. Calibrate the spring as described in paragraph 7.
WARNING!:
The securing points marked with A and B can be used with MOOVI 50RMM only. The securing point marked with C can be used with MOOVI 30S/30RMM only. If the point found is within the crossed area that means that installation is not possible and it is necessary to shorten the boom or reduce the number of accessories.
If no accessory is used, only use the weight of the “PA” boom to nd the
securing point.
6.7.2) Moovi 30S
For Moovi 30S model, observe the following: Max. boom length: 3m Hooking point: C Accessories that can be used without shortening the boom: BIR - PCA
- Moovi Light
Accessories that cannot be used: GA/GAMA – SB
7) BAR BALANCING (Fig.9)
- Activate the emergency release (g.14).
- Position the bar at about 45° (g.9). The bar must remain still.
- If the bar tends to open, unload the spring by operating on the “T” tie rod.
- If the bar tends to close, load the spring by operating on the “T” tie rod.
- In both cases, load or unload the spring until the bar remains still at about 45°.
- Reset the motorised operation by rotating the release key to the op-
posite direction (g.14).
WARNING! During the closing operation, the balancing spring must never be reduced to a pack (be totally compressed). Fig.9 indicates the position where the minimum value of the compressed spring is measured with the rod in the opening (vertical bar) position.
8) ELECTRICAL INSTALLATION SET-UP
WARNING: before opening the door, make sure that the spring has been unloaded (rod at 43°). Set up the electrical installation (g. 10) with
reference to the current regu-lations for electrical installations CEI64-8, IEC364, in conformity with HD384 and other national standards. Keep
the mains power supply con-nections denitely separate from the service
connections (photocells, elec-tric edges, control devices etc.).
Warning! For connection to the mains, use a multipolar cable having minimum 3x1.5mm
2
cross section and complying with the previously
mentioned regulations (for example, if the cable is not protected, it
must be at least equal to H07 RN-F, whereas if it is protected it must be at least equal to H07 VV-F with a 3x1.5 sq mm
2
cross section).
Connect the control and safety devices in conformity with the previously mentioned installation standards. Fig.10 shows the number of connections and section for a 100m length of power supply cables; for greater lengths, calculate the section for the true automation load. When the auxiliary connections exceed 50-metre lengths or go through critical disturbance areas, it is recommended to decouple the control and safety devices by means of suitable relays.
The main automation components are (g.10):
Type-approved adequately rated omnipolar circuit-breaker with
I)
at least 3,5 mm contact opening, provided with protection against overloads and short circuits, suitable for cutting out automation from the mains. Place, if not al ready installed, a type-approved differential switch with a 0.03A threshold just before the automa­tion system.
Control panel and incorporated receiver.
QR) S) Key selector. AL) Blinker with tuned antenna. M) Actuators. A) Bar. F) Rest fork. CS) Electric edge. CC) Edge control. Ft,Fr) Pair of photocells. CF) Photocell post. T) 1-2-4 channel transmitter. RMM) Inductive metal mass detector. LOOP) Mass detector loops.
9) LEO-MV-D CONTROL PANEL
Power supply:
............................................................220-230V 50/60Hz
Mains/low voltage insulation: .................................... > 2MOhm 500V
Dielectric strength: ....................mains/low voltage 3750V~ for 1 minute
Motor output current: Maximum motor power:
................................................................1.5Amax
................................................................. 750W
Supply to accessories: .................................. 24V~ (1A max absorption)
Gate-open warning light:
........................................ 220-230V~ 3W max
Blinker: ..................................................................220-230V~ 40W max
Dimensions:
....................................................................... see gure 17
Fuses:..................................................................................see gure 18
10) TERMINAL BOARD CONNECTIONS (Fig.19) WARNING – During the wiring and installation operations, refer to the
current standards as well as principles of good technical practice. The cables must be tied by additional fastening next to the terminals, by means of clips for example.
All the operator wiring operations must be carried out by qualied personnel.
JP1
1 GND terminal 2-3 Single-phase mains supply 220-230V 50/60Hz (2=N) (3=L)
JP2
4-5 Blinker connection (mains voltage) 40W Max. 6-7-8-9 Motor connection: 6 operation 1 + capacitor 7 common (blue) 8 operation 2 9 capacitor
JP3
10-11 Output 24V~ 1A max – power supply for photocells or other
devices.
12-13 Gate-open warning light output (24V 3W max)
JP4 Barrier status output
20-18 Closed Contact with barrier raised 20-19 Closed Contact with barrier lowered Contact switching for barrier status control. To be used in Parky systems.
Encoder connection
JP5
WARNING! The maximum length of the connection cable of
the encoder should not exceed 3.00 mt.
JP8
21-22 Open-Close button (N.O. Start), key selector. 21-23 Block button (N.C. Stop). If not used, leave jumped. 21-24 Photocell input (N.C.). If not used, leave jumped. 21-25 Opening limit switch connection (N.C. SWO). If not used,
leave jumped.
21-26 Closing limit switch connection (N.C. SWC). If not used, leave
jumped.
MOOVI 30S-30RMM-50RMM Ver. 06 - 19
ENGLISH
INSTALLATION MANUAL
21-27 Not used 21-28 Open-Button connection (N.O. Open) 21-29 Close-Button connection (N.O. Close) 21-30 Rubber edge connection (N.C.). If not used, leave jumped. 21-31 Connection of clock input (N.O.). If the contact connected is
JP9
32 Photocell check input (PHOT FAULT) (see Fig. 19) 33 Electric edge check input (EDGE FAULT) (see Fig. 19) 38-39 Antenna input for radio-receiver (38 signal - 39 braid). Cable
11) PROGRAMMING
The control panel provided with a microprocessor is supplied with func­tion parameters preset by the manufacturer, suitable for standard instal-
lations. The predened parameters can be altered by means of either
the incorporated display programmer or Universal palmtop programmer. In the case where programming is carried out by means of Universal palmtop
programmer, carefully read the instructions relating to Universal palmtop programmer, and proceed in the following way.
Connect the Universal palmtop programmer to the control unit through the
UNIFLAT accessory (See g. 20). Enter the “CONTROL UNITS” menu,
and the “PARAMETERS” submenu, then scroll the display screenfuls us­ing the up/down arrows, and set the numerical values of the parameters listed below. For the function logics, refer to the “LOGIC” submenu. In the case where programming is carried out by means of the incorporated
programmer, refer to Fig. A and B and to the “conguration” paragraph.
12) CONFIGURATION
The display programmer is used to set all the LEO MV D control panel functions. The programmer is provided with three pushbuttons for menu scrolling
and function parameter congurations:
+ menu scrolling/value increment key
- menu scrolling/value reduction key
OK Enter (conrm) key
The simultaneous pressure of the + and – keys is used to exit the active menu and move to the preceding menu. If the + and – keys are pressed simultaneously at the main menu level (parameters, logics, radio, language, autosetting), programming is exited and the display is switched off (the OK message is displayed).
The modications made are only set if the OK key is subsequently pressed. When the OK key is pressed for the rst time, the programming mode
is entered.
The following pieces of information appear on the display at rst:
- Control unit Software version
- Number of total manoeuvres carried out (the value is expressed in thousands, therefore the display constantly shows 0000 during the
rst thousand manoeuvres)
- Number of manoeuvres carried out since the latest maintenance operation (the value is expressed in thousands, therefore the display
constantly shows 0000 during the rst thousand manoeuvres)
- Number of memorised radio control devices.
When the OK key is pressed during the initial presentation phase, the
rst menu (parameters) can be accessed directly.
Here follows a list of the main menus and the respective submenus available. The predened parameter is shown between square brackets [ 0 ]. The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the control unit conguration procedure.
12.1) Parameter Menu (PARAM)
1 - Automatic Closing Time (TCA) [ 10s ]
Set the numerical value of the automatic closing time from 1 to 180
seconds.
2 - Slow-down Distance (Cm. rall) [ 5 ]
Set the required slow-down distance for opening and closing between
1 and 90.
NOTE: power failure, reset, or manual gate release, the control panel carries out a complete manoeuvre at reduced speed, in order to learn the length of stroke.
3- Alarm time (alarm. time) [ 30s ] In the case of obstacle detection or photocell engagement, at the end
of the time set (ranging from 10s to 240s) the SCA contact is closed. The contact is subsequently opened by the STOP command or by triggering of the closing limit switch. Only active when the SCA Alarm logic is set to OFF.
4- Zone (zone) [ 0 ]
open, the barrier closes and gets ready for normal operation. If the contact is closed (N.C.), the barrier opens and remains open until contact opening.
RG58.
Set the zone number between a minimum value of 0 and a maximum
value of 128. See paragraph 8 on “Serial connection”.
5- Slow-down torque (slud torque ) [ 99% ]
Set the motor torque value during the slow-down phase between 0%
and 99%.
6- Opening torque (open torque) [ 70% ]
Set the motor opening torque value between 1% and 99%.
7- Closing torque (cls. torque) [ 70% ]
Set the motor closing torque value between 1% and 99%.
8 - Brake (Brake) [ 52% ]
Set the required brake value between 0 and 99%, compatibly with the
weight of the rod and the existing stresses.
9 - Encoder (Encoder) [ 1 ] 0: encoder disabled: timed slow-down, obstacle detection function
not active. (The encoder can be disconnected).
1: encoder enabled: slow-down and obstacle detection by means of
encoder (default).
WARNING: Check that the impact force value measured at the points established by the EN 12445 standard is lower than
that specied in the EN 12453 standard.
Incorrect sensitivity setting can cause injuries to persons or
animals, or damage to things.
10- Type of barrier (barrier) [1]
0: MOOVI 30RMM/50RMM mod. barrier 1: MOOVI 30S mod. barrier 2: BGV mod. barrier Factory-preset value, in case of maintenance or malfunctions, check
the correspondence between the setting and the barrier model.
With the MOOVI 30RMM/50RMM barrier (0) , the following func-
tions are not active:
- slow down
- torque setting (the barrier always works at maximum torque).
With the BGV barrier (2) , the following functions are not active:
- slow down
- torque setting (the barrier always works at maximum torque). obstacle detection.
12.2) Logic Menu (logic.)
- TCA ( tca ) [ ON ]
ON Activates automatic closing OFF Excludes automatic closing
- 3 Steps (3 step) [ ON ]
ON Enables 3-step logic. A start impulse has the following effects:
barrier closed: ......................................................................opens
on opening: ........................stops and enters TCA (if congured)
barrier open: ........................................................................closes
on closing:......................................stops and reverses movement
after stopping: ......................................................................opens
OFF Disables 3-step logic
- Opening Impulse lock (Ibl open) [ ON ]
ON The Start impulse has no effect during the opening phase. OFF The Start impulse becomes effective during the opening phase.
- Impulse lock TCA (ibl TCA ) [ OFF ]
ON The Start impulse has no effect during the TCA dwell period. OFF The Start impulse becomes effective during the TCA dwell period.
- Pre alarm (pre-alarM) [ OFF ]
ON The blinker comes on about 3 seconds before the motor starts. OFF The blinker comes on at the same time as the motor starts.
- Photocells on opening (photc. open) [ ON ]
ON: In case of obscuring, this excludes photocell operation on opening.
During the closing phase, it immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and
on closing. When a photocell is obscured on closing, it reverses the motion only after the photocell is disengaged.
- Rapid closing (fast cls )
ON: Closes barrier after photocell disengagement, before waiting for
the end of the TCA (automatic closing time) set.
OFF: Command not entered.
- SCA Alarm (SCA alarm) [ ON ]
ON: The SCA contact (terminals 12-13) behaves as follows: with barrier open and on opening:...contact closed (warning light on)
with barrier closed:contact open.........................(warning light off)
on closing:........................................intermittent contact (blinking)
OFF: The SCA contact closes according to the modes set by the Alarm
Time parameter.
- Master/Slave (Master) [ OFF ]
ON: The control panel is set as Master in a centralised connection (see
Paragraph 7).
OFF: The control panel is set as Slave in a centralised connection (see
Paragraph 7).
[ OFF ]
D811480_07
20 - MOOVI 30S-30RMM-50RMM Ver. 06
Loading...
+ 16 hidden pages