3500/62 Process Variable Monitor
Datasheet
Bently Nevada Machinery Condition Monitoring
Description
The 3500/62 Process Variable Monitor is a 6-channel monitor
for processing machine critical parameters that merit
continuous monitoring, such as pressures, flows,
temperatures, and levels. The monitor accepts +4 to +20 mA
current inputs or any proportional voltage inputs between -10
Vdc and +10 Vdc. It conditions these signals and compares
the conditioned signals to user-programmable alarm
setpoints.
The 3500/62 monitor:
l Continuously compares monitored parameters
against configured alarm setpoints to drive alarms for
machinery protection.
l Provides essential machine information for both
operations and maintenance personnel.
You can program the 3500/62 using the 3500 Rack
Configuration Software to perform either current or voltage
measurements. The 3500/62 offers I/O modules for three
signal input scenarios: +/-10 Volts DC, isolated 4-20 mA, or 420 mA with Intrinsically Safe zener barriers. The Internal Barrier
I/O provides external power input terminals to provide
intrinsically safe power to the 4-20 mA transducers
141541 Rev. L
When used in a Triple Modular Redundant (TMR)
configuration, you must install Process Variable Monitors
adjacent to each other in groups of three. When used in this
configuration, the monitor employs two types of voting to
ensure accurate operation and to avoid loss of machinery
protection due to single-point failures.
Triple Modular Redundant (TMR)Units are no longer
available for purchase.
3500/62 Process Variable Monitor
Datasheet 141541 Rev. L
Specified at +25 °C (+77 °F). Full-scale
Specifications
Inputs
range for each channel is set in the field
via 3500 Configuration Software. No
calibration is required.
Signal
+/-10 Vdc I/O -10 Vdc to +10 Vdc
4-20 mA Barrier I/O 4-20 mA DC
4-20 mA Isolated I/O 4-20 mA DC.
Voltage Compliance
(4-20 mA Barrier I/O
4-20mA out)
Isolation
(4-20 mA ISO I/O
only)
Input Impedance
+/-10V I/O 1 MΩ
4-20 mA Barrier I/O 50 Ω
4-20 mA Isolated I/O 50 Ω
Power Consumption
External transducer
Power (Internal
Barrier I/O Only)
13.66 V
500 volts
7.0 watts, typical.
+24 Vdc. +/- 5% @ 250
mA max. Fused
Outputs
Front Panel LEDs
Accuracy Within ±0.33% of full-scale
typical, ±1% maximum.
Full Scale
Range
Maximum 20,000 units mapped
over the input signal span.
Minimum input signal span for
voltage input is 2 volts.
Alarms
Alarm Setpoints
User can set Alert and Danger setpoints for the
value measured by the monitor. Alarms are
adjustable and can normally be set from 0 to
100% of full-scale for each measured value. The
exception is when the full-scale range exceeds
the range of the sensor in which case the
setpoint will be limited to the range of the
sensor. Accuracy of alarms is to within 0.13% of
the desired value. The Process Variable Monitor
has both under and over alarm setpoints.
Alarm Time Delays
User can use software to set alarm delays as
follows:
Alert From 1 to 60 seconds in 1 second
intervals.
Danger From 1 to 60 seconds in 0.5
second intervals.
OK LED Indicates when the Process
Variable Monitor is operating
properly.
TX/RX LED Indicates when the Process
Variable Monitor is
communicating with other
modules in the 3500 rack.
Bypass LED Indicates when the Process
Variable is in Bypass Mode.
Signal Conditioning
Proportional Values
Proportional values are Process Variable
measurements used to monitor the machine.
The Process Variable Monitor returns current or
voltage proportional values in a variety of
different units that are configurable.
Environmental Limits
Operating
Temperature
2/10
-30°C to +65°C (-22°F to
+149°F) when used with
Internal/External Termination
3500/62 Process Variable Monitor
Datasheet 141541 Rev. L
I/O Module.
Operating
Temperature
Storage
Temperature
Humidity 95%, noncondensing.
0°C to +65°C (+32°F to +149°F)
when used with Internal Barrier
I/O Module (Internal
Termination).
40°C to +85°C
(-40°F to +185°F).
Monitor Module
Dimensions
(height x
width x
depth)
Weight 0.82 kg (1.8 lbm)
I/O Modules (without barriers)
Dimensions
(height x
width x
depth)
241.3 mm x 24.4 mm x 241.8 mm
9.50 in x 0.96 in x 9.52 in)
241.3 mm x 24.4 mm x 99.1 mm
(9.50 in x 0.96 in x 3.90 in)
Weight: 0.20 kg (0.44 lbm)
I/O Module (with barriers)
Dimensions
(height x
width x
depth)
Weight 0.46 kg (1.01 lbm)
241.3 mm x 24.4 mm x 99.1 mm
(9.50 in x 0.96 in x 3.90 in)
Rack Space Requirements
Monitor
Module
I/O
Modules
1 full-height front slot.
1 full-height rear slot.
3/10