Bently Nevada 3500/62 Datasheet

3500/62 Process Variable Monitor
Datasheet
Bently Nevada Machinery Condition Monitoring

Description

The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters that merit continuous monitoring, such as pressures, flows, temperatures, and levels. The monitor accepts +4 to +20 mA current inputs or any proportional voltage inputs between -10 Vdc and +10 Vdc. It conditions these signals and compares the conditioned signals to user-programmable alarm setpoints.
The 3500/62 monitor:
l Continuously compares monitored parameters
against configured alarm setpoints to drive alarms for machinery protection.
l Provides essential machine information for both
operations and maintenance personnel.
You can program the 3500/62 using the 3500 Rack Configuration Software to perform either current or voltage measurements. The 3500/62 offers I/O modules for three signal input scenarios: +/-10 Volts DC, isolated 4-20 mA, or 4­20 mA with Intrinsically Safe zener barriers. The Internal Barrier I/O provides external power input terminals to provide intrinsically safe power to the 4-20 mA transducers
141541 Rev. L
When used in a Triple Modular Redundant (TMR) configuration, you must install Process Variable Monitors adjacent to each other in groups of three. When used in this configuration, the monitor employs two types of voting to ensure accurate operation and to avoid loss of machinery protection due to single-point failures.
Triple Modular Redundant (TMR)Units are no longer available for purchase.
3500/62 Process Variable Monitor Datasheet 141541 Rev. L
Specified at +25 °C (+77 °F). Full-scale

Specifications

Inputs
range for each channel is set in the field via 3500 Configuration Software. No calibration is required.
Signal
+/-10 Vdc I/O -10 Vdc to +10 Vdc
4-20 mA Barrier I/O 4-20 mA DC
4-20 mA Isolated I/O 4-20 mA DC.
Voltage Compliance (4-20 mA Barrier I/O 4-20mA out)
Isolation (4-20 mA ISO I/O only)
Input Impedance
+/-10V I/O 1 MΩ
4-20 mA Barrier I/O 50 Ω
4-20 mA Isolated I/O 50 Ω
Power Consumption
External transducer Power (Internal Barrier I/O Only)
13.66 V
500 volts
7.0 watts, typical.
+24 Vdc. +/- 5% @ 250 mA max. Fused
Outputs
Front Panel LEDs
Accuracy Within ±0.33% of full-scale
typical, ±1% maximum.
Full Scale Range
Maximum 20,000 units mapped over the input signal span. Minimum input signal span for voltage input is 2 volts.
Alarms
Alarm Setpoints
User can set Alert and Danger setpoints for the value measured by the monitor. Alarms are adjustable and can normally be set from 0 to 100% of full-scale for each measured value. The exception is when the full-scale range exceeds the range of the sensor in which case the setpoint will be limited to the range of the sensor. Accuracy of alarms is to within 0.13% of the desired value. The Process Variable Monitor has both under and over alarm setpoints.
Alarm Time Delays
User can use software to set alarm delays as follows:
Alert From 1 to 60 seconds in 1 second
intervals.
Danger From 1 to 60 seconds in 0.5
second intervals.
OK LED Indicates when the Process
Variable Monitor is operating properly.
TX/RX LED Indicates when the Process
Variable Monitor is communicating with other modules in the 3500 rack.
Bypass LED Indicates when the Process
Variable is in Bypass Mode.
Signal Conditioning
Proportional Values
Proportional values are Process Variable measurements used to monitor the machine. The Process Variable Monitor returns current or voltage proportional values in a variety of different units that are configurable.
Environmental Limits
Operating Temperature
2/10
-30°C to +65°C (-22°F to +149°F) when used with Internal/External Termination
3500/62 Process Variable Monitor Datasheet 141541 Rev. L
I/O Module.
Operating Temperature
Storage Temperature
Humidity 95%, noncondensing.
0°C to +65°C (+32°F to +149°F) when used with Internal Barrier I/O Module (Internal Termination).
40°C to +85°C (-40°F to +185°F).
Monitor Module
Dimensions (height x width x depth)
Weight 0.82 kg (1.8 lbm)
I/O Modules (without barriers)
Dimensions (height x width x depth)
241.3 mm x 24.4 mm x 241.8 mm
9.50 in x 0.96 in x 9.52 in)
241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Weight: 0.20 kg (0.44 lbm)
I/O Module (with barriers)
Dimensions (height x width x depth)
Weight 0.46 kg (1.01 lbm)
241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
Rack Space Requirements
Monitor Module
I/O Modules
1 full-height front slot.
1 full-height rear slot.