Bently Nevada 3500/05 Data sheet

Page 1
3500/05 System Rack
Datasheet
Bently Nevada Machinery Condition Monitoring

Description

Use the 3500 System rack to mount all 3500 monitor modules and power supplies. The rack allows you to place 3500 modules near one another, enabling them to easily communicate, and to mount power supplies necessary to distribute power to each module.
3500 racks are available in two sizes:
Full-size rack. 19-inch EIA rack with 14 available module slots.
You can order 3500 racks in three formats:
Panel mount. This rack format mounts to rectangular cut-
outs in panels, and secures to the panel using clamps supplied with the rack. Wiring connections and I/O modules are accessible from the rear of the rack.
Rack mount. This rack format mounts the 3500 Rack on 19­inch EIA rails. Wiring connections and I/O modules are accessible from the rear of the rack.
141525 Rev. M
Bulkhead mount. This rack format mounts the rack against a wall or panel when it is not possible to access the rear of the rack. Wiring connections and I/O modules are accessible from the front of the rack. The 3500/05 Mini-Rack is not available in this format.
The power supplies and rack interface module must occupy the far-left rack positions. The remaining 14 rack positions (seven rack positions for the mini-rack) are available for any combination of modules.
If you plan to install internal barriers in the 3500 rack, consult Specifications and Ordering Information for 3500 Internal Barriers (document 141495) available from Bently.com.
Page 2
3500/05 System Rack Datasheet 141525 Rev. M

Compliance and Certifications

FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
l This device may not cause harmful
interference.
l This device must accept any
interference received, including interference that may cause undesired operation.
EMC
European Community Directive:
EMC Directive 2014/30/EU
Standards:
EN 61000-6-2 Immunity for
Industrial Environments
EN 61000-6-4 Emissions for
Industrial Environments
Electrical Safety
European Community Directive:

Hazardous Area Approvals

For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from
Bently.com.
CSA/NRTL/C
Class I, Zone 2: AEx/Ex nA nC ic IIC T4 Gc; Class I, Zone 2: AEx/Ex ec nC ic IIC T4 Gc; Class I, Division 2, Groups A, B, C, and D;  T4 @ Ta= -20˚C to +65˚C (-4˚F to +149˚F) When installed per drawing 149243 or 149244.
ATEX/IECEx
II 3 G
Ex nA nC ic IIC T4 Gc Ex ec nC ic IIC T4/T5 Gc  T4 @ Ta= -20˚C to +65˚C (-4˚F to +149˚F) When installed per drawing 149243 or 149244. 
LV Directive 2014/35/EU
Standards:
EN 61010-1
European Community Directive:
RoHS Directive 2011/65/EU
ABS - Marine and Offshore Applications
DNV GL Rules for Classification – Ships, Offshore Units, and High Speed and Light Craft
2/8
Page 3
3500/05 System Rack Datasheet 141525 Rev. M
02 ATEX/IECEx/CSA (Class 1, Zone 2)

Ordering Considerations

Racks with Internal Barriers installed require a 3500/04-01 Internal Barrier Earthing Module to provide the IS Earth connection to the 3500/05 rack. This earthing module requires a dedicated rack position.
The 3500/93 System Display A01 System Face Mount option is incompatible with the 3500/05 Mini-rack.
The 3500/05 mini-rack is not available in the Bulkhead Mount option.
The 3500/06 weatherproof housing is not compatible with the 3500/05 Bulkhead Mount option.
When using a 3500 mini-rack in an EIA rack, a 144863-01 19-inch EIA Adapter Panel is required.
The 3500 mini-rack requires Version 2.70 or later of the 3500/01 Software.

Ordering Information

For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from
Bently.com.
Product Description
3500/05-AA-BB-CC-DD-EE
A: Rack Size 01 19-inch Rack (14 module slots) 02 12-inch Mini-Rack (7 module slots)
B: Mounting Options 01 Panel Mount Option, Full-Size Rack
02
03
04 Panel Mount Option, Mini-Rack 05 Rack Mount Option, Mini-Rack
C: Agency Approval Option 00 None 01 CSA/NRTL/C (Class 1, Division 2)
Rack Mount Option, Full-Size Rack (mounts to 19-inch EIA Rack)
Bulkhead Mount Option (not available in Mini-Rack)
D: Reserved 00 None
E: European Compliance Option 01 CE
Spares
Part Number Description
Half-height Module Adapter
125388-01
125565-01
04300111
Power Supply Blank Cover Kit
131150-01
128085-01
04310251
Full-height Blank Monitor Cover Kit Order as 130768-01. Includes:
130944-01
128031-01
04310251 Screw for I/O Module Cover (qty 2)
Half-height Blank Monitor Cover Kit
131151-01
Miscellaneous Components
00561941
144863-01 Adapter Panel, Mini-rack, 19-inch
129766-01
130432-01 Field Wiring Diagrams
Half-height module Internal Chassis (qty 1)
Half-height Module Card Guide (qty
1) Screws for half-height Module
Internal Chassis (qty 3)
Power Supply Blank Front Panel (qty 1, includes screws)
Power Supply Input Connector Cover (qty 1) Order part 04310251 for screws.
Screws for Power Supply Input Cover (qty 2)
Full-height Monitor Blank Front Panel (qty 1, includes screws)
I/O Module Cover (qty 1) Order part 04310251 for screws.
Half-height Blank Front Panel Cover (qty 1, includes screws)
TMR/SIM jumper (installed on the 3500 backplane)
Rack Installation and Maintenance Manual
3/8
Page 4
3500/05 System Rack Datasheet 141525 Rev. M

Figures and Drawings

1. 265.94 mm (10.470 in.) 2. 482.60 mm (19.000 in.) 3. 441.96 mm (17.400 in.) 4. 246.38 mm (9.700 in.) 5. 349.25 mm (13.750 in.), 422.91 mm (16.650 inches) if used
with internal barriers
Figure 1: 3500 Full-Size rack mounting dimensions for the Rack and Panel Mount Configuration
1. 452.1 +/- 1.5 mm (17.80 +/- 0.06 in.) 2. 3.2 mm (0.125 in.) radius, maximum 3. 251.5 +/- 1.5 mm (9.90 +/- 0.60 in.)
1. 452.1 +/- 1.5 mm (17.80 +/- 0.06 in.) 2. 3.2 mm (0.125 in.) radius, maximum 3. 251.5 +/- 1.5 mm (9.90 +/- 0.60 in.)
Figure 2: 3500 Full-Size Rack Recommended Panel Cutout
4/8
Page 5
3500/05 System Rack Datasheet 141525 Rev. M
1. 10.470 inches (265.94 mm). 2. 12.000 inches (304.80 mm). 3. 10.400 inches (264.16 mm). 4. 9.700 inches (246.38 mm). 5. 13.750 inches (349.25 mm), 16.650 inches (422.91 mm) if
used with internal barriers
Figure 3: 3500 Mini-rack mounting dimensions for the Panel Mount Configuration
1. 274.3 +/- 1.5 mm (10.80 +/- 0.06 in.) 2. 3.2 mm (0.125 in.) radius, maximum. 3. 251.5 +/- 1.5 mm (9.90 +/- 0.60 in)
Figure 4: 3500 Mini-rack Recommended Panel Cutout
5/8
Page 6
3500/05 System Rack Datasheet 141525 Rev. M
1. 3500 Mini-rack 2. Adapter Panel 3. Standard 19-inch EIA rack
Figure 5: 3500 Mini-rack and Adapter Panel mounting to a 19-inch EIA Rack
6/8
Page 7
3500/05 System Rack Datasheet 141525 Rev. M
1. 482.60 mm (19.000 inches) 2. 459.59 mm (18.094 inches) 3. 133.35 mm (5.250 inches) 4. 190.50 mm (7.500 inches) 5. 133.35 mm (5.250 inches) 6. 532.64 mm (20.970 inches)
7. 266.70 mm (10.500 inches)
Figure 6:  Dimensions of a Bulkhead Mount 3500 rack
7/8
Page 8
3500/05 System Rack Datasheet 141525 Rev. M
Copyright 2020 Baker Hughes Company. All rights reserved.
Bently Nevada and Orbit Logo are registered trademarks of Bently Nevada, a Baker Hughes Business, in the United States and other countries. The Baker Hughes logo is a trademark of Baker Hughes Company. All other product and company names are trademarks of their respective holders. Use of the trademarks does not imply any affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not make any representation as to the accuracy or completeness of the information and makes no warranties of any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect, consequential or special damages, claims for lost profits, or third party claims arising from the use of the information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of BakerHughes and its affiliates; and is subject to change without prior notice. It is being supplied as a service to our customers and may not be altered or its content repackaged without the express written consent of Baker Hughes. This product or associated products may be covered by one or more patents. See Bently.com/legal.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 1.775.782.3611 or 1.800.227.5514 (US only)
Bently.com
8/8