Bently Nevada 330505 Specifications

330505 Low Frequency Velocity Sensor
Datasheet
Bently Nevada Machinery Condition Monitoring

Description

The Bently Nevada 330505 Low Frequency Velocity Sensor is specifically designed for hydroelectric turbines where slow rotating speeds require detecting a low signal to noise ratio. It detects vibration of the stator core, stator frame, and bearing housing supports. It is designed to provide early warning of pending machinery problems and to help you diagnose problems before they become serious.
1.0kHz range. Its two-wire design uses moving-coil technology and embedded signal conditioning circuitry to provide a voltage output directly proportional to the vibration velocity.
Stator core and stator frame vibration can cause fretting and damage to the winding insulation. To detect these problems before serious damage occurs, mount a 330505 sensor on the outer diameter of the stator core and frame.
169872 Rev. F
Bearing housing vibration can distort levels of vibration measured by shaft-observing proximity probes. To detect premature failure of machine components and prevent significant machine problems, place 330505 sensors in locations that measure both shaft-relative and bearing­absolute vibration signals. You can mount 330505 sensors to the bearing housing either as a stand-alone measurement or in the same orientation as existing proximity sensors.
The 330505 Transducer connects to the 3500/46M Hydro Monitor, meeting the requirements of International Organization for Standardization (ISO) Standard 10816-5 for mechanical vibration on non-rotating parts in hydraulic power and pumping plants.
Due to the nature of high amplitude, low frequency velocity events, the 330505 Low Frequency Velocity Sensor is not recommended for automated machinery protection. Due to capacitance constraints, this sensor is not approved for hazardous areas.
330505 Low Frequency Velocity Sensor Datasheet 169872 Rev. F

Specifications

Parameters are specified from +20 to +30°C (+68 to +86°F) and 80Hz unless otherwise indicated.
Operation outside the specified limits may result in false readings or loss of machine monitoring.
Electrical
Sensitivity 20 mV/mm/s (508mV/in/s) ±10%
Frequency Response
Velocity Range
Amplitude Range
Amplitude Linearity
Output Bias Voltage
Maximum Cable Length
Environmental Limits
Operating and storage temperature range
Shock Survivability
0.5—1000 Hz (30—60,000 cpm) ±3.0 dB; 1—200 Hz (60—12,000 cpm) ±0.9 dB
102 mm/s (4 in/s) peak
See 330505 Vibration Nomograph on page6.
±3%—102 mm/s (4 in/s) peak
-12 ±1 VDC
305 metres (1000 feet) with no degradation of signal, when used with 3500/46M
Maximum mounted surface temperature
-40°C to +100°C (-40°F to +212°F)
981 m/s2 (100g) peak
(typical)
Mounting See 330505 System Dimensional
Drawing on page7.
Case material
Connector 2-pin Mil-C-5015 receptacle,
Mounting Torque
Polarity Pin A becomes positive with
300 series stainless steel.
hermetically sealed, 300 series stainless steel.
46 kg cm (40 in-lb) max.
respect to Pin B when the applied velocity is from the base to the top of the transducer.

Compliance and Certifications

FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
l This device may not cause harmful
interference.
l This device must accept any
interference received, including interference that may cause undesired operation.
EMC
EMC Directive 2014/30/EU

RoHS

Relative Humidity
To 100% non-submerged; case is hermetically sealed.
Physical
Weight < 375grams (13.2oz)
RoHS Directive 2011/65/EU
2/12
330505 Low Frequency Velocity Sensor Datasheet 169872 Rev. F
89411-01 Individual 1/4 - 28 UNF mounting

Ordering Information

For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from Bently.com.
330505-AA-BB-CC
89412-01 Individual 1/4 - 20 UNC mounting
89413-01 Individual 1/4 - 18 NPT mounting
04300015 Individual 5/8 - 18 UNF mounting
adapter
adapter
adapter
adapter.
A: Transducer Mounting Angle
0 1 0° ± 10°
0 2 90° ± 5°
0 3 180° ± 10°
B: Internal Mounting Thread
0 2 3/8-24 UNF-2B
C: Mounting Adapter Option
0 0 No Adapter
0 1 1/2 - 20 UNF
0 2 M8 x 1
0 3 1/4 - 28 UNF
0 4 1/4 - 20 UNC
0 5 1/4 - 18 NPT
0 6 5/8 - 18 UNF
161191 Individual 1/2 - 13 UNC mounting
adapter
Interconnection Cables
The following standard cable lengths are available. You can order custom cable lengths in increments of one foot at additional cost. Some cables have a minimum and maximum length. For details, see each part description below.
Standard Cable Lengths
Feet Meters (approximate)
6 ft 1.8 m
8 ft 2.4 m
10 ft 3.0 m
12 ft 3.6 m
15 ft 4.5 m
0 7 3/8 – 16 UNC
Accessories
For more information, please refer to the 330505 Low Frequency Velocity Sensor User Guide (document 169873).
Part number
89409-01 Individual 1/2 - 20 UNF mounting
adapter.
89410-01 Individual M8 x 1 mounting
adapter
Description
17 ft 5.0 m
20 ft 6.0 m
25 ft 7.6 m
30 ft 9.0 m
33 ft 10.0 m
50 ft 15.2 m
99 ft 30.0 m
3/12
330505 Low Frequency Velocity Sensor Datasheet 169872 Rev. F
Cable Part Numbers
Part number Description
† NOTE: Use ‘AA’ in the part numbers below to specify the length (in feet) of the cable you want to order.
02173034 Splash-Proof Interconnect
Cable
Recommended for high electromagnetic noise environment and European Conformance (CE).
Shielded 0.382 mm2 (22 AWG) cable with a splash proof boot over a female connector at the transducer end and flush cut at the monitor end. Temperature range -55 to 125°C (-67 to 257°F). See Graphs and
Figures.
CB2W100­AAA†
Splash-Proof Interconnect Cable
Shielded 0.382 mm2 (22 AWG) cable with splash proof over molded boot, blunt cut at the monitor end. Temperature range -50 to 200°C (-58 to 392°F). See
Graphs and Figures.
Standard lengths:
Part number Description
9571-AA† Standard Interconnect Cable
Shielded 0.382 mm2 (22 AWG) cable with a moisture resistant female connector at the transducer end and ring lugs at the monitor end. Temperature range -29 to 121°C (-20 to 250°F). See
Graphs and Figures.
Minimum length 2 ft (0.60 m); maximum length 99 ft (30 m).
84661-AA† Standard Armored
Interconnect Cable
Stainless steel armor over shielded 0.382 mm2 (22 AWG) cable with a moisture resistant female connector at the transducer end and ring lugs at the monitor end. Temperature range -29 to 121°C (-20 to 250°F). See
Graphs and Figures.
Minimum length 3 ft (0.91 m); maximum length 96 ft (29 m).
89477-AA† Right Angle Interconnect
Cable
01515 ft (4.5 m)
03232 ft (9.8 m)
06464 ft (19.5 m)
112112 ft (34.1 m)
125125 ft (38.1 m)
150150 ft (45.7 m)
200200 ft (61.09 m)
Shielded 0.963 mm2 (18 AWG) cable with a moisture resistant right angle female connector at the transducer end and ring lugs at the monitor end. Temperature range -29 to 121°C (-20 to 250°F). See Graphs and