Bently Nevada 330180 Specifications

Page 1
Bently Nevada* Asset Condition Monitoring
3300 XL 8mm Proximity Transducer System
Description
The 3300 XL 8 mm Proximity Transducer System consists of:
One 3300 XL 8 mm probe, One 3300 XL extension cable One 3300 XL Proximitor
The system provides an output voltage that is directly proportional to the distance between the probe tip and the observed conductive surface and can
measure both static (position) and dynamic (vibration) values. The system’s
primary applications are vibration and position measurements on fluid-film bearing machines, as well as Keyphasor* reference and speed measurements3.
1
, and
*
Sensor2.
The 3300 XL 8 mm system delivers the most advanced performance in our eddy current proximity transducer systems. The standard 3300 XL 8 mm 5-metre system also fully complies with the American Petroleum Institute’s (API) 670 Standard (4th Edition) for mechanical configuration, linear range, accuracy, and temperature stability. All 3300 XL 8 mm proximity transducer systems provide this level of performance and support complete interchangeability of probes, extension cables, and Proximitor sensors, eliminating the need to match or bench calibrate individual components.
Each 3300 XL 8 mm Transducer System component is backward-compatible and interchangeable4 with other non-XL 3300 series 5 mm and 8 mm transducer system components5. This compatibility includes the 3300 5 mm probe, for applications in which an 8 mm probe is too large for the available mounting
6,7
space
Proximitor Sensor
The 3300 XL Proximitor Sensor incorporates numerous improvements over previous designs. Its physical packaging allows you to use it in high-density DIN­rail installations. You can also mount the sensor in a traditional panel mount configuration, where it shares an identical 4-hole mounting “footprint” with older Proximitor Sensor designs. The mounting base for either option provides electrical isolation and eliminates the need for separate isolator plates. The 3300 XL Proximitor Sensor is highly immune to radio frequency interference, allowing you to install it in fiberglass housings without adverse effects from nearby radio
frequency signals. The 3300 XL Proximitor Sensor’s improved RFI/EMI immunity
satisfies European CE mark approvals without requiring special shielded conduit or metallic housings, resulting in lower installation costs and complexity.
.
The 3300 XL’s SpringLoc terminal strips require no special installation tools and
facilitate faster, more robust field wiring connections by eliminating screw-type clamping mechanisms that can loosen.
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 1 of 35
Page 2
Proximity Probe and Extension Cable
The 3300 XL probe and extension cable also reflect improvements over previous designs. A patented TipLoc* molding method provides a more robust bond between the probe tip and the probe body.
The probe’s cable incorporates a patented CableLoc*
design that provides 330 N (75 lbf) pull strength to more securely attach the probe cable and probe tip.
You can also order 3300 XL 8 mm probes and extension cables with an optional FluidLoc* cable option. This option prevents oil and other liquids
from leaking out of the machine through the cable’s
interior.
Connectors
The 3300 XL probe, extension cable, and Proximitor sensor have corrosion-resistant, gold-plated ClickLoc* connectors. These connectors require only finger-tight torque (the connectors will "click" when tight), and the specially-engineered locking mechanism prevents the connectors from loosening. These connectors require no special tools for installation or removal.
You can order the 3300 XL 8 mm probes and extension cables with connector protectors already installed. We can also supply connector protectors separately for field installations (such as when an application must run the cable through restrictive conduit). We recommend connector protectors for all installations to provide increased environmental protection8.
Extended Temperature Range Applications
An extended temperature range (ETR) probe and ETR extension cable are available for applications in which either the probe lead or extension cable may exceed the standard 177 C (350 F) temperature specification. The ETR probe has an extended temperature rating for up to 218 C (425 F). The ETR extension cable rating is up to 260 C (500 F). Both the ETR probe and cable are compatible with standard temperature probes and cables, for example, you can utilize an ETR probe with the 330130 extension cable. The ETR system uses the standard 3300 XL Proximitor Sensor. Note that when you use any ETR component as part of your system, the ETR component limits the system accuracy to the accuracy of the ETR system.
Description Notes:
1. One-metre systems do not use an extension cable.
2. Proximitor sensors are supplied by default from the
factory calibrated to AISI 4140 steel. Calibration to other target materials is available upon request.
3. Consult Bently Nevada* Applications Note,
Considerations when using Eddy Current Proximity Probes for Overspeed Protection Applications, when
considering this transducer system for tachometer or overspeed measurements.
4. 3300 XL 8 mm components are both electrically and
physically interchangeable with non-XL 3300 5 mm and 8 mm components. Although the packaging of the 3300 XL Proximitor Sensor differs from its predecessor, its design fits in the same 4-hole mounting pattern when used with the 4-hole mounting base, and will fit within the same mounting space specifications (when minimum permissible cable bend radius is observed).
5. Mixing XL and non-XL 3300-series 5 mm and 8 mm
system components limits system performance to the specifications for the non-XL 3300 5 mm and 8 mm Transducer System.
6. The 3300-series 5 mm probe (refer to Specifications
and Ordering Information p/n 141605-01) uses smaller physical packaging, but does not reduce the side view clearances or tip-to-tip spacing requirements as compared to an 8 mm probe. It is used when physical (not electrical) constraints preclude the use of an 8 mm probe. When your application requires narrow side view probes, use the 3300 NSv* Proximity Transducer System (refer to Specifications and Ordering Information p/n 147385-
01).
7. 8 mm probes provide a thicker encapsulation of the
probe coil in the molded PPS plastic probe tip. This results in a more rugged probe. The larger diameter of the probe body also provides a stronger, more robust case. We recommend that you use 8 mm probes when possible to provide optimal robustness against physical abuse.
8. Each 3300 XL extension cable includes silicone tape
that you can use instead of connector protectors. We do not recommend silicone tape for applications that will expose the probe-to-extension cable connection to turbine oil.
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 2 of 35
Page 3
Probe Length
R
PROBE
(Ω)
0.5
7.45 0.50
1.0
7.59 0.50
1.5
7.73 0.50
2.0
7.88 0.50
3.0
8.17 0.60
5.0
8.73 0.70
9.0
9.87 0.90
Length of Extension
Cable (m)
R
CORE
(Ω)
3.0
0.66 0.10
3.5
0.77 0.12
4.0
0.88 0.13
4.5
0.99 0.15
6.0
1.32 0.21
7.0
1.54 0.23
7.5
1.65 0.25
8.0
1.76 0.26
8.5
1.87 0.28
Length of Extension
Cable (m)
R
JACKET
(Ω)
3.0
0.20 0.04
3.5
0.23 0.05
4.0
0.26 0.05
4.5
0.30 0.06
6.0
0.39 0.08
7.0
0.46 0.09
7.5
0.49 0.10
8.0
0.53 0.11
8.5
0.56 0.11
Specifications
Unless otherwise noted, the following specifications are for a 3300 XL 8 mm Proximitor Sensor, extension cable and 8 mm probe between +18 C and +27 C (+64 F to +80 F), with a -24 Vdc power supply, a 10
kΩ load, an AISI 4140 steel target, and a probe
gapped at 1.27 mm (50 mils). Performance characteristics apply to systems that consist solely of 3300 XL 8 mm components. The system accuracy and interchangeability specifications do not apply to transducer systems that are calibrated to any target other than our AISI 4140 steel target.
Electrical
Proximitor Sensor Input
Accepts one non-contacting 3300-series 5 mm, 3300 8 mm or 3300 XL 8 mm Proximity Probe and Extension Cable.
Power
Requires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption, -23 Vdc to -26 Vdc with barriers. Operation at a more positive voltage than -23.5 Vdc can result in reduced linear range.
Nominal Probe DC Resistance
Nominal Extension Cable DC Resistance
Resistance (R
) from Center
PROBE
Conductor to Outer Conductor
Resistance (R
) from Center
CORE
Conductor to Center Conductor
Supply Sensitivity
Output Resistance
Less than 2 mV change in output voltage per volt change in input voltage.
50
Resistance (R
) from Outer
JACKET
Conductor to Outer Conductor
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 3 of 35
Page 4
Extension Cable Capacitance
Field Wiring
Linear Range
69.9 pF/m (21.3 pF/ft) typical
2
0.2 to 1.5 mm
(16 to 24 AWG) . Recommend using 3-conductor shielded triad cable and tinned field wiring. Maximum length of 305 metres (1,000 feet) between the 3300 XL Proximitor Sensor and the monitor. See the frequency response graphs in through Figure 13 (pages 27 and
28) for signal rolloff at high frequencies when using longer field wiring lengths.
2 mm (80 mils). Linear range begins at approximately 0.25 mm (10 mils) from target and is from
0.25 to 2.3 mm (10 to 90 mils) (approximately –1 to –17 Vdc).
Extended Temperature Range (ETR) for 5- and 9-Metre Systems:
7.87 V/mm (200 mV/mil) ± 6.5% including interchangeability error when measured in increments of
0.25 mm (10 mils) over the 80 mil linear range from 0 °C to +45 °C (+32 °F to +113 °F).
Deviation from best fit straight line (DSL)
Standard 5- or 1-metre System:
Less than ±0.025 mm (±1 mil) with components at 0 °C to +45 °C (+32 °F to +113 °F).
Standard 9-metre System:
Recommended Gap Setting for Radial Vibration
Incremental Scale Factor (ISF)
Standard 5- or 1- metre System:
Standard 9-metre System:
-9Vdc [approximately 1.27 mm (50 mils)]
7.87 V/mm (200 mV/mil) ± 5% including interchangeability error when measured in increments of
0.25 mm (10 mils) over the 80 mil linear range from 0 °C to +45 °C (+32 °F to +113 °F).
7.87 V/mm (200 mV/mil) ± 6.5% including interchangeability error when measured in increments of
0.25 mm (10 mils) over the 80 mil linear range from 0 °C to +45 °C (+32 °F to +113 °F).
Less than ±0.038 mm (±1.5 mil) with components at 0 °C to +45 °C (+32 °F to +113 °F).
Extended Temperature Range 5 and 9-metre Systems:
Less than ±0.038 mm (±1.5 mil) with components at 0 °C to +45 °C (+32 °F to +113 °F).
Performance over Extended Temperatures
Standard 5- or 1-metre System:
Over a probe temperature range of –35 °C to +120 °C (-31 °F to +248 °F) with the Proximitor sensor and extension cable between 0 °C to +45°C (+32 °F to +113 °F), the ISF remains within ±10% of 7.87 V/mm (200 mV/mil) and the DSL remains within ±0.076 mm (±3 mils).
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 4 of 35
Page 5
Gap (mil)
5- or
1-metre
Proximitor
Sensor
9-metre
Proximitor
Sensor
Probe
Ext.
Cable
10
0.0119
0.0247
0.0004
0.0004
50
0.0131
0.0323
0.0014
0.0014
90
0.0133
0.0348
0.0045
0.0045
Standard 9-metre System:
Over a Proximitor sensor and extension cable temperature range of –35 °C to +65 °C (-31 °F to +149 °F) with the probe between 0 °C to +45 °C (+32 °F to +113 °F), the ISF remains within ±10% of 7.87 V/mm (200 mV/mil) and the DSL remains within ±0.076 mm (±3 mils).
Over a probe temperature range of –35 °C to +120 °C (-31 °F to +248 °F) with the Proximitor sensor and extension cable between 0 °C to +45°C (+32 °F to +113 °F), the ISF remains within ±18% of 7.87 V/mm (200 mV/mil) and the DSL remains within ±0.152 mm (±6 mils).
Over a Proximitor sensor and extension cable temperature range of –35 °C to +65 °C (-31 °F to +149 °F) with the probe between 0 °C to +45 °C (+32 °F to +113 °F), the ISF remains within ±18% of 7.87 V/mm (200 mV/mil) and the DSL remains within ±0.152 mm (±6 mils).
Minimum Target Size
15.2 mm (0.6 in) diameter (flat target)
Shaft Diameter
Minimum:
50.8 mm (2 in)
Recommended Minimum:
76.2 mm (3 in)
When gapped at the center of the linear range, the interaction between two separate transducer systems (cross-talk) will be less than 50 mV on shaft diameters of at least 50 mm (2 in) or greater. You should take care to maintain minimum separation of transducer tips, generally at least 40 mm (1.6 in) for axial position measurements or 38 mm (1.5 in) for radial vibration measurements to limit cross-talk to 50 mV or less. Radial vibration or position measurements on shaft diameters smaller than 76.2 mm (3 in) will generally change the scale factor.
Extended Temperature Range 5 and 9-metre Systems:
Frequency Response
Over a probe and extension cable temperature range of –35 °C to +260 °C (-31 °F to +500 °F) with the Proximitor sensor between 0 °C to +45 °C (+32 °F to +113 °F), the ISF remains within ±18% of
7.87 V/mm (200 mV/mil) and the DSL remains within ±0.152 mm (±6 mils).
(0 to 10 kHz), +0, -3 dB, with up to 305 metres (1000 feet) of field wiring.
Effects of 60 Hz Magnetic Fields up to 300 Gauss
Output Voltage in Mil pp/Gauss
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 5 of 35
Page 6
Temperature
Classification
Ambient Temperature
(Probe Only)
T1
-51ºC to +232ºC
T2
-51ºC to +177ºC
T3
-51ºC to +120ºC
T4
-51ºC to +80ºC
T5
-51ºC to +40ºC
Note: Probe entity parameters are met when used with BN extension cables and connected to BN Prox.
Compliance and Certifications
EMC
European Community Directives: EMC Directive 2004/108/EC Standards: EN61000-6-2 EN61000-6-4
Maritime
ABS 2009 Steel Vessels Rules 1-1-4/7.7, 4-8-3/1.11.1, 4-9-7/13
Hazardous Area Approvals
Note: For a detailed listing of country and product specific
approvals, refer to the Approvals Quick Reference Guide (document 108M1756) located at the following website:
www.GEmeasurement.com.
CSA/NRTL/C
3300 XL Proximitor Sensor and probe, ia:
Ex ia IIC T4/T5; Class I Zone 0 or Class 1; Groups A, B, C, and D, Class II, Groups E, F and G, Class III when installed with intrinsically safe zener barriers per drawing 141092 or when installed with galvanic isolators.
3300 XL Proximitor Sensor and probe, nA:
Ex nA IIC T4/T5 Class I Zone 2 or Class I, Division 2, Groups A, B, C, and D, when installed without barriers per drawing 140979. T5 @ Ta= -35 C to +85 C. T4 @ Ta= -51 C to +100 C.
ATEX/IECEx
3300 XL Proximitor Sensor
ia:
II 1 G Ex ia IIC T4/T5 Ga T5 @ Ta= -35 C to +85 C T4 @ Ta= -51 C to +100 C
Ui= -28V Ci = 0 Ii= 140mA Li =10µH Pi= 0.91W
nA:
II 3 G Ex nA IIC T4/T5 Gc T5 @ Ta= -35 C to +85 C T4 @ Ta= -51 C to +100 C
3300 XL 8mm probe
ia:
II 1 G Ex ia IIC T1…T5 Ga, (see Table 1: Temperature Schedule)
Ui = -28V Ci = 1.5 nF Ii = 140 mA Li = 210 µH Pi = 0.91 W
nA:
II 3 G Ex nA IIC T1…T5 Gc, (see Table 1: Temperature Schedule).
Ui = -28V
Table 1: Temperature Schedule
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 6 of 35
Page 7
Hazardous Area Conditions of Safe Use:
CSA/NRTL/C:
ia:
nA:
ATEX/IECEx:
ia:
nA:
Install per Bently Nevada drawing
141092.
Install per Bently Nevada drawing
140979.
The Prox must be installed so as to minimize the risk of impact or friction with other metallic surfaces.
The Prox must be installed so as to provide the terminals with a degree of protection of at least IP54.
Mechanical
Probe Tip Material
Polyphenylene sulfide (PPS).
Probe Case Material
AISI 303 or 304 stainless steel (SST).
Probe Cable Specifications
Standard cable:
75Ω triaxial, fluoroethylene
propylene (FEP) insulated probe cable in the following total probe lengths: 0.5, 1, 1.5, 2, 3, 5, or 9 metres.
Extended Temperature Range cable:
75Ω triaxial, perfluoroalkoxy (PFA)
insulated probe cable in the following total probe lengths: 0.5, 1, 1.5, 2, 5, or 9 metres.
Armor (optional on both):
Tensile Strength (Maximum Rated):
Connector Material:
Flexible AISI 302 or 304 SST with FEP outer jacket.
330 N (75 lbf) probe case to probe lead.
270 N (60 lbf) at probe lead to extension cable connectors.
Gold-plated brass or gold-plated beryllium copper.
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 7 of 35
Page 8
Probe Type
Maximum
Rated
Recommended
Standard
forward-mounted
probes
33.9 Nm
(300 inlbf)
11.2 Nm
(100 inlbf)
Standard forward-
mount probes -
first three threads
22.6 Nm
(200 inlbf)
7.5 Nm
(66 inlbf)
Reverse-mount
probes
22.6 Nm
(200 inlbf)
7.5 Nm
(66 inlbf)
Connector Type
Tightening Instructions
Two 3300 XL gold
"click" type
connectors
Finger tight
One non-XL stainless
steel connector and
one 3300 XL
connector
Finger tight plus 1/8 turn
using pliers
Probe Case Torque:
Extension Cable Material
Standard cable:
Extended Temperature Range cable:
Minimum Cable Bend Radius:
75Ω triaxial, fluoroethylene
propylene (FEP) insulated.
75Ω triaxial, perfluoroalkoxy (PFA)
insulated.
Connector-to­connector recommended torque:
Proximitor Sensor Material
A308 aluminum
Connector Material:
Gold-plated brass or gold-plated beryllium copper.
System Length
5 or 9 metres (including extension cable) or 1 metre (probe only).
Total System Mass (Typical)
0.7 kg (1.5 lbm)
Note: 3300 XL 8 mm components are both electrically and
physically interchangeable with non-XL 3300 5 mm and 8 mm components when minimum permissible cable bend radius is observed..
Connector Material:
Maximum Connector Torque:
25.4 mm (1.0 in)
Gold-plated brass or gold-plated beryllium copper.
0.565 Nm (5 inlbf)
Probe:
323 g (11.4 oz)
Extension Cable:
34 g/m (0.4 oz/ft)
Armored Extension Cable:
103 g/m (1.5 oz/ft)
Proximitor Sensor:
246 g (8.67 oz)
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 8 of 35
Page 9
Environmental Limits
Probe Temperature Range
Operating and Storage Temperature
Standard Probe:
-51 °C to +177 °C (-60 °F to +350 °F)
Extended Temperature Range Probe:
-51 °C to +218 °C (-60 °F to +425°F) for the probe tip; -51 °C to +260 °C (-60 °F to +500 °F) for the probe cable and connector.
Note: Exposing the probe to temperatures below –34 C (-30 F)
may cause premature failure of the pressure seal.
Probe Pressure
3300 XL 8 mm probes are designed to seal differential pressure between the probe tip and case. The probe sealing material consists of a Viton® O-ring. Probes are not pressure tested prior to shipment. Contact our custom design department if you require a test of the pressure seal for your application.
Note: It is the responsibility of the customer or user to ensure
that all liquids and gases are contained and safely controlled should leakage occur from a proximity probe. In addition, solutions with high or low pH values may erode the tip assembly of the probe causing media leakage into surrounding areas. Bently Nevada, Inc. will not be held responsible for any damages resulting from leaking 3300 XL 8 mm proximity probes. In addition, 3300 XL 8 mm proximity probes will not be replaced under the service plan due to probe leakage.
Extension Cable Temperature Range
Operating and Storage Temperature
Standard Cable:
-51 °C to +177 °C (-60 °F to +350 °F)
Extended Temperature Range Cable:
-51 °C to +260 °C (-60 °F to +500 °F)
Proximitor Sensor Temperature Range
Operating Temperature
-51 °C to +100 °C (-60 °F to +212 °F)
Storage Temperature
-51 °C to +105 °C (-60 °F to +221 °F)
Relative Humidity
Less than a 3% change in Average Scale Factor (ASF) when tested in 93% humidity in accordance with IEC standard 68-2-3 for up to 56 days.
Patents
Components or procedures described in one or more of the following patents apply to this product: 5,016,343; 5,126,664; 5,351,588; and 5,685,884.
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 9 of 35
Page 10
Ordering Information
Note: For a detailed listing of country and product specific
approvals, refer to the Approvals Quick Reference Guide (document 108M1756) located at the following website:
www.GEmeasurement.com.
Ordering Information Probes
3300 XL 8 mm Proximity Probes:
330101 3300 XL 8 mm Probe, 3/8-24 UNF thread, without armor2
330102 3300 XL 8 mm Probe, 3/8-24 UNF thread, with armor2
Part Number-AXX-BXX-CXX-DXX-EXX
A: Unthreaded Length Option
Note: Unthreaded length must be at least 0.8 inches less than
the case length.
Order in increments of 0.1 in
Length configurations: Maximum unthreaded length: 8.8 in Minimum unthreaded length: 0.0 in Example: 0 4 = 0.4 in
B: Overall Case Length Option
Order in increments of 0.1 in
Threaded length configurations: Maximum case length: 9.6 in Minimum case length: 0.8 in Example: 2 4 = 2.4 in
C: Total Length Option
0 5 0.5 metre (1.6 feet) 1 0 1.0 metre (3.3 feet) 1 5 1.5 metre (4.9 feet) 2 0 2.0 metres (6.6 feet) 3 0 3.0 metres (9.8 feet) 5 0 5.0 metres (16.4 feet) 9 0 9.0 metres (29.5 feet)
Notes: 3-metre length option is only available on 330101 probes,
and are designed for use with the 9-metre Proximitor sensor only.
5-metre probes are designed for use with the 5-metre
Proximitor sensor only.
D: Connector and Cable-Type Option
0 1 Miniature coaxial ClickLoc
connector with connector protector, standard cable
0 2 Miniature coaxial ClickLoc
connector, standard cable
1 1 Miniature coaxial ClickLoc
connector with connector protector, FluidLoc cable
1 2 Miniature coaxial ClickLoc
connector, FluidLoc cable
E: Agency Approval Option
0 0 Not required 0 5 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes, Metric:
330103 3300 XL 8 mm Probe, M10 x 1 thread, without armor2
330104 3300 XL 8 mm Probe, M10 x 1 thread, with armor2
Part Number-AXX-BXX-CXX-DXX-EXX
A: Unthreaded Length Option
Note: Unthreaded length must be at least 20 mm less than the
case length.
Order in increments of 10 mm.
Length configuration: Maximum unthreaded length: 230
mm
Minimum unthreaded length: 0 mm Example: 0 6 = 60 mm
B: Overall Case Length Option
Order in increments of 10 mm.
Metric thread configurations: Maximum length: 250 mm Minimum length: 20 mm Example: 0 6 = 60 mm
C: Total Length Option
0 5 0.5 metre (1.6 feet) 1 0 1.0 metre (3.3 feet) 1 5 1.5 metres (4.9 feet) 2 0 2.0 metres (6.6 feet) 5 0 5.0 metres (16.4 feet)
Note: 5-metre probes are designed for use with the 5-metre
Proximitor sensor only.
9 0 9.0 metres (29.5 feet)
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 10 of 35
Page 11
D: Connector and Cable-Type Option
0 1 Miniature coaxial ClickLoc
connector with connector protector, standard cable
0 2 Miniature coaxial ClickLoc
connector, standard cable
1 1 Miniature coaxial ClickLoc
connector with connector protector, FluidLoc cable
1 2 Miniature coaxial ClickLoc
connector, FluidLoc cable
E: Agency Approval Option
0 0 Not required 0 5 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Reverse Mount Probes
330105-02-12-CXX-DXX-EXX, 3/8-24 UNF threads2
330106-05-30-CXX-DXX-EXX, M10 x 1 threads2
Option Descriptions
C: Total Length Option
0 5 0.5 metre (1.6 feet) 1 0 1.0 metre (3.3 feet) 1 5 1.5 metre (4.9 feet) 2 0 2.0 metres (6.6 feet) 5 0 5.0 metres (16.4 feet)
Note: 5-metre probes are designed for use with the 5-metre
Proximitor sensor only.
9 0 9.0 metres (29.5 feet)
D: Connector Option
0 2 Miniature ClickLoc coaxial
connector
1 2 Miniature ClickLoc coaxial
connector, FluidLoc cable
Note: The FluidLoc cable option 12 is not necessary on the vast
majority of 330105 and 330106 installations due to the presence of the probe sleeve. Consider carefully the application before ordering the FluidLoc cable option for these probes.
3300 XL 8 mm Proximity Probes, Smooth Case:
330140 3300 XL 8 mm Probe without armor1
330141 3300 XL 8 mm Probe with armor1
Part Number-AXX-BXX-CXX-DXX
Option Descriptions
A: Overall Case Length Option
Order in increments of 0.1 in
Length configurations: Maximum length: 9.6 in Minimum length: 0.8 in Example: 2 4 = 2.4 in
B: Total Length Option
0 5 0.5 metre (1.6 feet) 1 0 1.0 metre (3.3 feet) 1 5 1.5 metres (4.9 feet) 2 0 2.0 metres (6.6 feet) 5 0 5.0 metres (16.4 feet)
Note: 5-metre probes are designed for use with the 5-metre
Proximitor sensor only.
9 0 9.0 metres (29.5 feet)
C: Connector and Cable-Type Option
0 1 Miniature coaxial ClickLoc
connector with connector protector, standard cable
0 2 Miniature coaxial ClickLoc
connector, standard cable
1 1 Miniature coaxial ClickLoc
connector with connector protector, FluidLoc cable
1 2 Miniature coaxial ClickLoc
connector, FluidLoc cable
D: Agency Approval Option
0 0 Not required 0 5 CSA, ATEX, IECEx Approvals
E: Agency Approval Option
0 0 Not required 0 5 CSA, ATEX, IECEx Approvals
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 11 of 35
Page 12
3300 XL 8 mm Extended Temperature Range (ETR) Proximity Probes:
330191 3300 XL 8 mm ETR Probe, 3/8-24 UNF thread, without armor
330192 3300 XL 8 mm ETR Probe, 3/8-24 UNF thread, with armor
Part Number-AXX-BXX-CXX-DXX
A: Unthreaded Length Option
Note: Unthreaded length must be at least 0.8 inches less than
the case length.
Order in increments of 0.1 in
Length configurations: Maximum unthreaded length: 8.8 in Minimum unthreaded length: 0.0 in Example: 1 5 = 1.5 in
B: Overall Case Length Option
Order in increments of 0.5 in
Threaded length configurations: Maximum case length: 9.6 in Minimum case length: 0.8 in Example: 2 5 = 2.5 in
C: Total Length Option
0 5 0.5 metre (1.6 feet) 1 0 1.0 metre (3.3 feet) 1 5 1.5 metre (4.9 feet) 2 0 2.0 metres (6.6 feet) 5 0 5.0 metres (16.4 feet)
Note: 5-metre probes are designed for use with the 5-metre
Proximitor sensor only.
9 0 9.0 metres (29.5 feet)
D: Agency Approval Option
0 0 Not required 0 5 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Extended Temperature Range (ETR) Proximity Probes, Metric:
330193 3300 XL 8 mm Probe, M10 x 1 thread, without armor 330194 3300 XL 8 mm Probe, M10 x 1 thread, with armor
Part Number-AXX-BXX-CXX-DXX
A: Unthreaded Length Option
Note: Unthreaded length must be at least 20 mm less than the
B: Overall Case Length Option
C: Total Length Option
Note: 5-metre probes are designed for use with the 5-metre
Proximitor sensor only.
D: Agency Approval Option
case length.
Order in increments of 10 mm.
Length configuration: Maximum unthreaded length: 230
mm
Minimum unthreaded length: 0 mm Example: 0 6 = 60 mm
Order in increments of 10 mm.
Metric thread configurations: Maximum length: 250 mm Minimum length: 20 mm Example: 0 6 = 60 mm
0 5 0.5 metre (1.6 feet) 1 0 1.0 metre (3.3 feet) 1 5 1.5 metres (4.9 feet) 2 0 2.0 metres (6.6 feet) 5 0 5.0 metres (16.4 feet)
9 0 9.0 metres (29.5 feet)
0 0 Not required 0 5 CSA, ATEX, IECEx Approvals
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 12 of 35
Page 13
3300 XL 8 mm Extended Temperature Range (ETR) Reverse Mount Probes
330195-02-12-CXX-DXX, 3/8-24 UNF threads
330196-05-30-CXX-DXX, M10 x 1 threads
C: Total Length Option
0 5 0.5 metre (1.6 feet) 1 0 1.0 metre (3.3 feet) 1 5 1.5 metre (4.9 feet) 2 0 2.0 metres (6.6 feet) 5 0 5.0 metres (16.4 feet)
Note: 5-metre probes are designed for use with the 5-metre
Proximitor sensor only.
9 0 9.0 metres (29.5 feet)
D: Agency Approval Option
0 0 Not required 0 5 CSA, ATEX, IECEx Approvals
3300 XL 8 mm Extended Temperature Range (ETR) Proximity Probes, Smooth Case:
330197 3300 XL 8 mm Probe without armor1
330198 3300 XL 8 mm Probe with armor1
Part Number-AXX-BXX-CXX
A: Overall Case Length Option
Order in increments of 0.5 in
Length configurations: Maximum length: 9.5 in Minimum length: 1.0 in Example: 3 5 = 3.5 in
B: Total Length Option
0 5 0.5 metre (1.6 feet) 1 0 1.0 metre (3.3 feet) 1 5 1.5 metres (4.9 feet) 2 0 2.0 metres (6.6 feet) 5 0 5.0 metres (16.4 feet)
Note: 5-metre probes are designed for use with the 5-metre
Proximitor sensor only.
9 0 9.0 metres (29.5 feet)
C: Agency Approval Option
0 0 Not required 0 5 CSA, ATEX, IECEx Approvals
Aluminum probe clamp bracket
1
137491-AXX
A: Mounting screw option
0 1 10-24 UNC-2A mounting
screws
0 2 M5 x 0.8-6g mounting screws
The aluminum clamp bracket is an unthreaded mounting bracket designed for use with the smooth case probes (330140, 330141, 330197 and 330198). After gapping the probe, tighten the clamp bracket by tightening the screws. The mounting screws have pre-drilled holes for safety wire.
Aluminum probe threaded mounting bracket
137492-AXX
A: Thread size
0 1 3/8-24 0 4 M10 x 1
The aluminum probe threaded mounting bracket is the standard mounting bracket for most 3300 and 3300 XL probe installations. The -01 option includes two 10-24 UNC-2A mounting screws. The -04 option includes two M5 x 0.8-6g mounting screws. The mounting screws have pre-drilled holes for safety wire.
Phenolic threaded probe mounting bracket
27474-AXX
A: Thread size
0 1 3/8-24 0 4 M10 x 1
We recommend the phenolic threaded mounting bracket if your application requires additional electric isolation from the mounting location (as in some generator and electrical motor bearing locations). The -01 option includes two 10-24 UNC­2A mounting screws. The -04 option includes two M5 x 0.8-6g mounting screws. The mounting screws have pre-drilled holes for safety wire.
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 13 of 35
Page 14
Probe Ordering Information Notes:
1. Mounting clamps must be ordered separately for
330140, 330141, 330197, and 330198.
2. For a shorter delivery time, order commonly stocked probes. The following part numbers are currently stocked probes:
330101-00-08-05-02-00, 330101-00-08-05-02-05, 330101-00-08-10-02-00, 330101-00-08-10-02-05, 330101-00-12-10-02-00, 330101-00-12-10-02-05, 330101-00-16-10-02-00, 330101-00-16-10-02-05, 330101-00-20-05-02-00, 330101-00-20-10-02-00, 330101-00-20-10-02-05, 330101-00-30-10-02-00, 330101-00-30-10-02-05, 330101-00-40-05-02-00, 330101-00-40-10-02-00, 330101-00-40-10-02-05, 330101-00-60-10-02-00, 330101-00-60-10-02-05, 330102-00-20-10-02-00, 330103-00-02-10-02-05, 330103-00-04-10-02-00, 330103-00-05-10-02-00, 330104-00-06-10-02-00, 330104-01-05-50-02-00, 330105-02-12-05-02-00, 330105-02-12-05-02-05, 330105-02-12-10-02-00, 330105-02-12-10-02-05, 330106-05-30-05-02-00, 330106-05-30-05-02-05, 330106-05-30-10-02-00, 330106-05-30-10-02-05.
Ordering Information Proximitor Sensor
3300 XL Proximitor Sensor
330180-AXX-BXX
A: Total Length and Mounting Option
1 0 1.0 metre (3.3 feet) system
length, panel mount
1 1 1.0 metre (3.3 feet) system
length, DIN mount
1 2 1.0 metre (3.3 feet) system
length, no mounting hardware
5 0 5.0 metre (16.4 feet) system
length, panel mount
5 1 5.0 metre (16.4 feet) system
length, DIN mount
5 2 5.0 metre (16.4 feet) system
length, no mounting hardware
9 0 9.0 metres (29.5 feet) system
length, panel mount
9 1 9.0 metres (29.5 feet) system
length, DIN mount
9 2 9.0 metres (29.5 feet) system
length, no mounting hardware
B: Agency Approval Option
0 0 Not required 0 5 CSA, ATEX, IECEx approvals
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 14 of 35
Page 15
Ordering Information Extension Cables
3300 XL Standard Extension Cable
330130-AXXX-BXX-CXX
Note: Make sure that the extension cable length and the probe
length, when added together, equal the Proximitor Sensor total length.
A: Cable Length Option
0 3 0 3.0 metres (9.8 feet) 0 3 5 3.5 metres (11.5 feet) 0 4 0 4.0 metres (13.1 feet) 0 4 5 4.5 metres (14.8 feet) 0 6 0 6.0 metres (19.7 feet) 0 7 0 7.0 metres (22.9 feet) 0 7 5 7.5 metres (24.6 feet) 0 8 0 8.0 metres (26.2 feet) 0 8 5 8.5 metres (27.9 feet)
B: Connector Protector and Cable Option
0 0 Standard cable 0 1 Armored cable 0 2 Standard cable with connector
protector
0 3 Armored cable with connector
protector
1 0 FluidLoc cable 1 1 Armored FluidLoc cable 1 2 FluidLoc cable with connector
protector
1 3 Armored FluidLoc cable with
connector protector
C: Agency Approval Option
0 0 Not required 0 5 CSA, ATEX, IECEx Approvals
3300 XL Extended Temperature Range (ETR) Extension Cable
330190-AXXX-BXX-CXX
Note: Make sure that the extension cable length and the probe
length, when added together, equal the Proximitor Sensor total length.
A: Cable Length Option
0 3 0 3.0 metres (9.8 feet) 0 3 5 3.5 metres (11.5 feet) 0 4 0 4.0 metres (13.1 feet) 0 4 5 4.5 metres (14.8 feet) 0 7 0 7.0 metres (22.9 feet) 0 7 5 7.5 metres (24.6 feet) 0 8 0 8.0 metres (26.2 feet) 0 8 5 8.5 metres (27.9 feet)
B: Cable Option
0 0 Standard cable 0 1 Armored cable
C: Agency Approval Option
0 0 Not required 0 5 CSA, ATEX, IECEx Approvals
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 15 of 35
Page 16
Accessories
141078-01
175751
176467
330181
02120015
138492-01
138493-01
Manual.
3300 XL Multi-Purpose Stainless Steel Housing. 12”x12”x6”. Can
hold up to 8 Proximitor Sensors in a DIN-mount configuration or 6 Proximitor Sensors in a panel­mount configuration. (Available with ATEX Zone 0 and Zone 1 certifications.)
3300 XL Multi-Purpose Stainless Steel Housing. 12”x8”x6”. Can
hold up to 4 3300XL Proximitor Sensors in both DIN-mount and panel-mount configurations. (Available with ATEX Zone 0 and Zone 1 certifications.)
3300 XL Multi-Purpose Stainless Steel Housing. 13”x9.5”x7”. Can
hold up to 8 Proximitor sensors in a DIN-mount configuration or 6 Proximitor Sensors in a panel­mount configuration. Primarily used by customers requiring hazardous area approvals fro their installations. Available with ATEX Zone 0 and Zone 1 and North American Division 1 and Division 2 certifications.
Bulk field wire. 1.0 mm2 (18 AWG), 3 conductor, twisted, shielded cable with drain wire. Specify length in feet.
Replacement panel-mount mounting pad.
Replacement DIN-mount mounting pad.
148722-01
3300 XL test plug. The 3300 XL
Test Plug contains 3 small test pins attached to 3 color-coded 1­metre wires, each terminated in a banana plug. The 3-pin adapter plugs into the test pin holes on 3300 XL-style Proximitor sensors. You can use this test plug to check the performance of the Proximitor sensor from the test pin holes in the terminal strip without removing the field wiring.
04310310
3300 XL Proximitor Sensor panel-mount screw. One 6-32
UNC thread forming mounting screw. Four screws are required for each Proximitor sensor. (Screws supplied standard with Proximitor housings [3300 XL panel-mount option]).
03200006
Silicone self-fusing tape. A 9.1-
metre (10-yard) roll of silicone tape to protect connectors. This tape is easy to install and provides excellent electrical isolation and protection from the environment. We do not recommend using this tape inside the casing of the machine.
40113-02
Connector Protector Kit.
Connector Protector Kit for 3300 XL 8 mm probes and extension cables, including connector protectors and installation tools.
136536-01
Connector protector adapter.
This allows you to use connector protector installation tools manufactured prior to 1998 with 75Ω ClickLoc connectors.
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 16 of 35
Page 17
40180-02
03839410
03839420
04301007
Connector protectors. Package
contains 10 pairs of connector protectors for 3300 XL 8 mm probes and extension cables.
75Ω triaxial male connector
protector. Male connector protectors install onto the extension cable and attach to the female connector protector on the probe, providing environmental protection of connectors.
75Ω triaxial female connector
protector. Female connector protectors install onto the probe lead and attach to the male connector protector on the extension cable, providing environmental protection of connectors. You can also place the connector protector onto the extension cable to slide over the connection to the Proximitor sensor to protect that connection from the environment.
330153-01
3300 XL connector kit. Used on
3300 XL 8 mm probes and extension cables. Contains 1 pair each of male and female ClickLoc connectors, 2 color-coded sleeves, 2 pieces of slit FEP tubing, and 1 strip of silicone tape.
330153-09
3300 XL ETR Connector Kit. Used
on ETR 3300 XL 8mm probes and 3300 ETR XL extension cables. Contains one pair of male and female ClickLoc connectors, two color-coded sleeves, two pieces of high temperature slit FEP tubing, and one strip of silicon tape.
163356
Connector Crimp Tool Kit.
Includes 1 set of multiconnector inserts and connector installation instructions. Compatible only with 330153 connector kits or with probes shipped in 2003 or later with ClickLoc connectors uninstalled. Supplied with carrying case.
04301008
3/8-24 probe lock nut with safety wire holes. Single probe
lock nut with 2 holes drilled through the nut in order to secure the lock nut in place with safety wire.
M10 x 1 probe lock nut with safety wire holes. Single probe
lock nut with 2 holes drilled through the nut in order to secure the lock nut in place with safety wire.
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 17 of 35
Page 18
-4
-2
0
2
4
DSL Error (mils)
Referenced to
7.87 V/mm (200
mV/mil)
-0.10
-0.05
0.00
0.05
0.10
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Gap (mm)
DSL Error (mm)
-10
-5
0
5
10
ISF Error (%)
Referenced to 7.87
V/mm (200 mV/mil)
-24
-22
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2 0
0 10 20 30 40 50 60 70 80 90 100
Gap (mils)
Output (Volts)
5m @ 25 °C (77 °F) 5m @ 45 °C (113 °F) 5m @ 0 °C (32 °F)
Graphs
Figure 1: Typical 3300 XL 8 mm 5m or 1m System over API 670 Testing Range
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 18 of 35
Page 19
-6
-4
-2
0
2
4
6
DSL Error (mils)
Referenced to
7.87 V/mm (200
mV/mil)
-0.15
-0.10
-0.05
0.00
0.05
0.10
0.15
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Gap (mm)
DSL Error (mm)
-10
-5
0
5
10
ISF Error (%)
Referenced to 7.87
V/mm (200 mV/mil)
-24
-22
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2 0
0 10 20 30 40 50 60 70 80 90 100
Gap (mils)
Output (Volts)
9m @ 25 °C (77 °F) 9m @ 45 °C (113 °F) 9m @ 0 °C (32 °F)
Figure 2: Typical 3300 XL 8 mm 9m System over API 670 Testing Range
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 19 of 35
Page 20
-6
-4
-2
0
2
4
6
DSL Error (mils)
Referenced to
7.87 V/mm (200
mV/mil)
-0.15
-0.10
-0.05
0.00
0.05
0.10
0.15
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Gap (mm)
DSL Error (mm)
-10
-5
0
5
10
ISF Error (%)
Referenced to 7.87
V/mm (200 mV/mil)
-24
-22
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2 0
0 10 20 30 40 50 60 70 80 90 100
Gap (mils)
Output (Volts)
1m Probe @ 25 °C (77 °F) 1m Probe @ -35 °C (-31 °F) 1m Probe @ 120 °C (248 °F)
Figure 3: Typical 3300 XL 8mm Probe over API 670 Operating Range
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 20 of 35
Page 21
-6
-4
-2
0
2
4
6
DSL Error (mils)
Referenced to
7.87 V/mm (200
mV/mil)
-0.15
-0.10
-0.05
0.00
0.05
0.10
0.15
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Gap (mm)
DSL Error (mm)
-10
-5
0
5
10
ISF Error (%)
Referenced to 7.87
V/mm (200 mV/mil)
-24
-22
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2 0
0 10 20 30 40 50 60 70 80 90 100
Gap (mils)
Output (Volts)
TC=25 °C (77 °F) Tc=-34 °C (-30 °F) Tc=-51 °C (-60 °F)
Figure 4: Typical 3300 XL 8 mm 5m Proximitor Sensor with 4m Extension Cable at Tc (Probe is at 25 C)
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 21 of 35
Page 22
-8
-6
-4
-2
0
2
4
6
8
DSL Error (mils)
Referenced to
200(mV/mil)
-0.20
-0.15
-0.10
-0.05
0.00
0.05
0.10
0.15
0.20
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Gap (mm)
DSL Error (mm)
-15
-10
-5
0
5
10
15
ISF Error (%)
Referenced to
200(mV/mil)
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2 0
0 10 20 30 40 50 60 70 80 90 100
Gap (mils)
Output (Volts)
25 °C (77 °F) 65 °C (149 °F) 85 °C (185 °F) 100 °C (212 °F)
Figure 5: Typical 3300 XL 8 mm 5m Proximitor Sensor with 4m Extension Cable at Th (Probe is at 25C)
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 22 of 35
Page 23
-8
-6
-4
-2
0
2
4
6
8
DSL Error (mils)
-0.20
-0.15
-0.10
-0.05
0.00
0.05
0.10
0.15
0.20
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Gap (mm)
DSL Error (mm)
-15
-10
-5
0
5
10
15
ISF Error (%)
-22
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2 0
0 10 20 30 40 50 60 70 80 90 100
Gap (mils)
Output (Volts)
Tc=+25 °C (+77 °F) Tc=-34 °C (-30 °F) Tc=-51 °C (-60 °F)
Figure 6: Typical 3300 XL 8mm 9 m Proximitor Sensor with 8m of Extension Cable at Tc (Probe is at 25 C)
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 23 of 35
Page 24
-8
-6
-4
-2
0
2
4
6
8
DSL Error (mils)
-0.20
-0.15
-0.10
-0.05
0.00
0.05
0.10
0.15
0.20
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Gap (mm)
DSL Error (mm)
-15
-10
-5
0
5
10
15
ISF Error (%)
-22
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2 0
0 10 20 30 40 50 60 70 80 90 100
Gap (mils)
Output (Volts)
Th=+25 °C (+77 °F) Th=+65 °C (+149 °F) Th=+85 °C (+185 °F) Th=+100 °C (+212 °F)
Figure 7: Typical 3300 XL 8mm 9m Proximitor Sensor with 8m Extension Cable at Th (Probe is at 25 C)
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 24 of 35
Page 25
-10
-8
-6
-4
-2
0
2
4
6
8
10
DSL Error (mils)
-0.25
-0.20
-0.15
-0.10
-0.05
0.00
0.05
0.10
0.15
0.20
0.25
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Gap (mm)
DSL Error (mm)
-15
-10
-5
0
5
10
15
ISF Error (%)
-24
-22
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2 0
0 10 20 30 40 50 60 70 80 90 100
Gap (mils)
Output (Volts)
Th=+25 °C (+77 °F) Th =+260 °C (+500 °F)
Figure 8: Typical 3300 XL Extended Temperature Range Probe and 4m Extended Temperature Range Extension
Cable at Th (Proximitor Sensor and Probe Tip with 1-foot Cable are at +25 C)
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 25 of 35
Page 26
-10
-8
-6
-4
-2
0
2
4
6
8
10
DSL Error (mils)
-0.25
-0.20
-0.15
-0.10
-0.05
0.00
0.05
0.10
0.15
0.20
0.25
0.00 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50
Gap (mm)
DSL Error (mm)
-15
-10
-5
0
5
10
15
ISF Error (%)
-24
-22
-20
-18
-16
-14
-12
-10
-8
-6
-4
-2 0
0 10 20 30 40 50 60 70 80 90 100
Gap (mils)
Output (Volts)
Th=+25 °C (+77 °F) Th=+260 °C (+500 °F)
Figure 9: Typical 3300 XL Extended Temperature Range Probe and 8m Extended Temperature Range Extension
Cable at Th (Proximitor Sensor and Probe Tip with 1-foot Cable are at +25 C)
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 26 of 35
Page 27
Frequency Response to Different Field Wiring Lengths
without Barriers (5 m System)
-5
-4
-3
-2
-1
0
1
100 1,000 10,000 100,000
Frequency (Hz)
Magnitude (dB)
No field wiring 1000' wiring 2000' wiring 5000' wiring 12,000' wiring
Phase Response with Different Field Wiring Lengths, No
Barriers (5 m System)
-100
-90
-80
-70
-60
-50
-40
-30
-20
-10
0
100 1,000 10,000 100,000
Frequency (Hz)
Phase Angle (degrees)
No field wiring 1000' wiring 2000' wiring 5000' wiring 12,000' wiring
Figure 10: Frequency Response, Typical 3300 XL 8mm 5m or 1m System with Varying Lengths of Field Wiring
Attached, No Barriers
Figure 11: Phase Response, Typical 3300 XL 8mm 5m or 1m System with Varying Lengths of Field Wiring Attached,
No Barriers
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 27 of 35
Page 28
Frequency Response to Different Field Wiring Lengths without
Barriers (9 m System)
-5
-4
-3
-2
-1
0
1
100 1,000 10,000 100,000
Frequency (Hz)
Magnitude (dB)
No field wiring 1000' field wiring 2000' field wiring 5000' field wiring 12,000' field wiring
Phase Response with Different Field Wiring Lengths, No
Barriers (9 m System)
-100.00
-90.00
-80.00
-70.00
-60.00
-50.00
-40.00
-30.00
-20.00
-10.00
0.00
100 1,000 10,000 100,000
Frequency (Hz)
Phase Angle (degrees)
No field wiring 1000' field wiring 2000' field wiring 5000' field wiring 12,000' field wiring
Figure 12: Frequency Response, Typical 3300 XL 8mm 9m System with Varying Lengths of Field Wiring Attached,
No Barriers
Figure 13: Phase Response, Typical 3300 XL 8mm 9m System with Varying Lengths of Field Wiring Attached, No
Barriers
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 28 of 35
Page 29
2.5 (0.10)
2
1
4
5
7
8
9
6
10
3
Figures
Note: All dimensions shown in millimetres (inches) except as noted.
1. Probe tip, 8.0 mm (0.31 in) diameter
2. 9/16 in for 3/8-24 threads, M17 for M10 threads (see Note 2)
3. Case thread
4. 5/16 in wrench flats for 3/8-24 threads; 8mm wrench flats for M10 threads.
5. 75Ω cable, 3.68 mm (0.145 in) maximum outside diameter, 3.94 mm (0.155 in) maximum outside diameter for FluidLoc cable,
7.67 mm (0.302 in) outside diameter of armor, 9.5 mm (0.38 in) maximum diameter of armor ferrule
6. Miniature male coaxial connector, 7.24 mm (0.285 in) maximum outside diameter “D”
7. Unthreaded length “A”
8. Case length “B”
9. 6.0 mm (0.235 in) maximum
10. Total length “C”, +30%, -0%
3
Figure 14: 3300 XL 8mm Proximity Probes, Standard Mount
330101 and 330191, 3/8-24 UNF-2A, without armor
7
330102 and 330192, 3/8-24 UNF-2A, with armor 6
330103 and 330193, M10X1 thread, without armor 7
330104 and 330194, M10X1 thread, with armor 6
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 29 of 35
Page 30
2 (0.08)
5 (0.2)
1
2
3
4
6
5
7
8
9
1. Probe tip, 8.0 mm (0.31 in) diameter
2. 7/16 in or M10 hexagonal
3. Case thread
4. 75Ω cable, 3.68 mm (0.145 in) outside diameter
5. Miniature male coaxial connector, 7.24 mm (0.285 in) maximum outside diameter “D”
6. Unthreaded length “A”, 5.0 mm (0.20 in)
7. Case length “B”, 30 mm (1.2 in)
8. 6.0 mm (0.235 in) maximum
9. Total length “C”, +30%, -0%
330105 and 330195, 3/8-24 UNF-2A threads
3
Figure 15: 3300 XL 8mm Proximity Probes, Reverse Mount
4, 7
330106 and 330196, M10X1 threads
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 30 of 35
Page 31
2.54 (0.100)
1
2
3
4
5
6
8
7
9
1. Probe tip, 8 mm (0.31 in) diameter
2. 9.66 mm (0.38 in) maximum diameter
3. 5/16 in wrench flats, 4 each
4. 75Ω cable, 3.68 mm (0.145 in) maximum diameter, 3.94 mm (0.155 in) maximum diameter for FluidLoc cable, 7.67 mm (0.302
in) outside diameter with armor, 10.2 mm (0.4 in) maximum diameter for armor ferrule
5. Miniature male coaxial connector, 7.24 mm (0.285 in) maximum outside diameter “D”
6. Case length “A”,
7. 349.3 (13.75) max. distance
8. 6.0 mm (0.235 in) maximum
9. Total length “C”, +30%, -0%
3
Figure 16: 3300 XL 8mm Proximity Probes, Smooth Case
330140 and 330197, without armor
330141 and 330198, with armor
7
6
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 31 of 35
Page 32
3
2
4
5
1
(3.30)
83.8 (3.30)
83.8
(3.30)
83.883.8
(3.30)
1
2
3
4
5
6
7
8
9
1. 7.24 mm (0.285 in) maximum diameter
2. Miniature male coaxial connector
3. FEP or PFA coated armor, armor length 300 mm (11.8 in) less than cable length (see Note 6)
4. 75Ω cable, 3.7 mm (0.15 in) maximum outside diameter, 3.94 mm (0.155 in) maximum diameter for FluidLoc cable, 7.67 mm
(0.302 in) maximum outside diameter of armor, 10.2 mm (0.40 in) maximum diameter of armor ferrule
5. 7.24 mm (0.285 in) maximum diameter
6. Stainless steel ferrules, 10.2 mm (0.40 in) max diameter
7. FEP or PFA insulated triaxial cable
8. Miniature female coaxial connector
9. Cable length, +20%, -0%
Figure 17: Extension Cable without Connector Protectors
330130, 3300 XL Extension Cable (FEP Armor and Insulation)
330190, 3300 XL ETR Extension Cable (PFA Armor and Insulation)
1. 12.4 mm (0.49 in) maximum diameter
2. 51.1 mm (2.01 in) maximum
3. 36.3 mm (1.43 in) maximum.
4. 12.4 mm (0.49 in) maximum diameter
5. Connector protector (fluorosilicone material) only installed on female end when optioned. Both ends available as accessories.
Figure 18: Extension Cable with Connector Protectors
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 32 of 35
Page 33
1. Mounting option “A”, Options –50 or -90
Figure 19: Panel Mount 3300 XL Proximitor Sensor
1. Mounting option “A”, Options –51 or –91
2. 35mm DIN rail (not included)
3. 89.4 mm (3.52 in). Additional 3.05 mm (0.120 in) clearance required to remove DIN rail.
Figure 20: DIN Mount 3300 XL Proximitor Sensor
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 33 of 35
Page 34
1. Mounting option “A”, Options –50 or -90
Figure 21: Physical Mounting Characteristics Showing Interchangeability of 3300 and 3300 XL Proximitor Sensors
when 4-hole Mounting Option Is Used
8
Figure Notes:
1. All dimensions on figures are in millimetres (inches) unless otherwise noted.
2. Standard mount 8 mm probes supplied with M17 or 9/16 inch lock nut.
3. Probes ordered with 5 or 9 metre integral cables have a length tolerance of +20%, -0%.
4. Reverse mount probes not available with armor or connector protector options.
5. Letters inside quotation marks on figures refer to probe ordering options.
6. Stainless steel armor is supplied with FEP outer jacket for standard probes, PFA outer jacket for ETR probes.
7. FEP jacket is standard non-armored portion of the cable for standard probes, PFA jacket on non-armored portion
for ETR probes.
8. Use M3.5 or #6 screws for panel-mount Proximitor Sensors (screws provided when purchasing Bently Nevada
housings).
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 34 of 35
Page 35
* Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company.
Viton is a trademark of E. I. Du Pont de Nemours and Company.
© 1999-2016 Bently Nevada, Inc. All rights reserved.
Printed in USA. Uncontrolled when transmitted electronically.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 775.782.3611 Fax: 775.215.2873
www.GEmeasurement.com
Specifications and Ordering Information
Part Number 141194-01
Rev. AA (01/16)
Page 35 of 35
Loading...