Bently Nevada 3300 XL 11 Specifications

3300 XL 11mm Proximity Transducer System
Datasheet
Bently Nevada Machinery Condition Monitoring

Description

Transducer System
The 3300 XL 11 mm Proximity Transducer System consists of:
l 3300 XL 11 mm probe l 3300 XL 11 mm extension cable l 3300 XL 11 mm Proximitor Sensor
The 3300 XL 11 mm Proximity Transducer System has a 3.94 V/mm (100 mV/mil) output for non-contacting vibration and displacement measurements on fluid film bearing machines. The large 11 mm tip enables this transducer system to have a longer linear range compared to our standard 3300 XL 8 mm Transducer System. It is primarily used in the following applications where the longer linear range is necessary:
l Axial (thrust) position measurements l Ramp differential expansion measurements on steam
turbines
l Rod position or rod drop measurements on
reciprocating compressors l Tachometer and zero speed measurements l Phase reference (Keyphasor) signals
146256 Rev. K
1
The 3300 XL 11 mm Proximitor Sensor is designed to replace the 7200-series 11 mm and 14 mm Transducer Systems. When upgrading from the 7200-series system to the 3300 XL 11 mm system, every component must be replaced with 3300 XL 11 mm components. In addition, the monitoring system must be updated. If using a 3500 Monitoring System, an updated version of the configuration software that lists the 3300 XL 11 mm Transducer System as a compatible option is required. Existing 3300 Monitoring Systems may need a modification. Contact your local sales and service representative for assistance.
3300 XL 11mm Proximity Transducer System Datasheet 146256 Rev. K
 The 3300 XL 11 mm Proximity Transducer is designed for measuring position or vibration within a frequency range of 0 to 8 kHz. Typical applications of this system include radial vibration and position, axial position and Keyphasor measurements.
Although the terminals and connector on the Proximitor sensor have protection against electrostatic discharge, take reasonable precautions to avoid electrostatic discharge during handling.
Proximitor Sensor
The 3300 XL 11 mm Proximitor Sensor has the same advanced features found in the 3300 XL 8 mm Proximitor Sensor. Its thin design allows it to be mounted in either a high-density DIN-rail installation or a more traditional panel mount configuration. Improved RFI/EMI immunity allows the 3300 XL Proximitor Sensor to achieve European CE mark approvals without any special mounting considerations. This RFI immunity also prevents the transducer system from being adversely affected by nearby high frequency radio signals. SpringLoc terminal strips on the Proximitor Sensor require no special installation tools and facilitate faster, highly robust field wiring connections.
3300 XL Probes and Extension Cables can also be ordered with a FluidLoc cable option. This option prevents oil and other liquids from leaking out of the machine through the cable’s interior. The connector protector option provides additional protection of the connectors in a humid or moist environment. Connector protectors are recommended for all installations and provide increased environmental protection2. Additionally, the 3300 XL 11 mm probe comes standard with a locknut with pre-drilled safety wire holes.
Notes:
1. Proximitor Sensors are supplied by
default from the factory calibrated to AISI 4140 steel. Calibration to other target materials is available upon request.
2. Silicone tape is also provided with each
3300 XL extension cable and can be used instead of connector protectors. Silicone tape is not recommended in applications where the probe-to-extension cable connection will be exposed to turbine oil.
Proximity Probe and Extension Cable
The 3300 XL 11 mm probe comes in varying probe case configurations, including armored and unarmored ½-20, 5⁄8 -18, M14 X 1.5 and M16 X
1.5 probe threads. The reverse mount 3300 XL 11 mm probe comes standard with either 3⁄8 -24 or M10 X 1 threads. All components of the transducer system have gold-plated brass ClickLoc connectors. ClickLoc connectors lock into place, preventing the connection from becoming loose. The patented TipLoc molding method provides a robust bond between the probe tip and the probe body. The probe cable is securely attached to the probe tip utilizing our patented CableLoc design that provides 330 N (75 lb) pull strength.
2/25
3300 XL 11mm Proximity Transducer System Datasheet 146256 Rev. K
Extension

Specifications

Unless otherwise noted, the following specifications are for a 3300 XL 11 mm Proximitor Sensor, extension cable and probe between 0°C and +45°C (+32°F to +113°F), with a -24 Vdc power supply, a 10 kW load, our supplied AISI 4140 steel target that is 31 mm (1.2 in) diameter or larger, and a probe gap of 2.5 mm (100 mils). The system accuracy and interchangeability specifications do not apply when using a transducer system calibrated to any target other than our AISI 4140 steel target.
Electrical
Proximitor Sensor
Accepts one non-contacting 3300 XL
Input
Power
Supply Sensitivity
Output resistance
Probe dc Resistance
Probe Length (m)
1.0 5.9 ± 0.5
5.0 7.2 ± 0.8
9.0 8.5 ± 1.1
Length of Extension Cable (m)
4.0 1.0 ± 0.25 0.3 ± 0.1
8.0 2.0 ± 0.5 0.6 ± 0.2
11 mm Proximity Probe and Extension Cable.
Requires -17.5 Vdc to -26 Vdc without barriers at 12 mA maximum consumption, -23 Vdc to -26 Vdc with barriers. Operation at a more positive voltage than -23.5 Vdc can result in reduced linear range.
Less than 2 mV change in output voltage per volt change in input voltage.
50 Ω
Resistance from the Center Conductor to the Outer Conductor (R
Extension Cable dc Resistance
Resistance from Center Conductor to Center Conductor (R (ohms)
PROBE
) (ohms)
CORE)
Resistance from Coaxial Conductor to Coaxial Conductor (R
JACKET
) (ohms)
cable capacitance
Field wiring
Linear Range
Recommended Gap Setting
Incremental Scale Factor (ISF)
Deviation from best fit straight line (DSL)
Standard DSL range
Extended DSL range
System Performance over extended temperatures
69.9 pF/m (21.3 pF/ft) typical
0.2 to 1.5 mm2 (16 to 24 AWG) [0.25 to 0.75 mm2 (18 to 23 AWG) with ferrules]. Recommend using three­conductor shielded triad cable. Maximum length of 305 meters (1,000 feet) between the 3300 XL Proximitor Sensor and the monitor. See the frequency response graph for signal rolloff at high frequencies when using longer field wiring lengths.
4.0 mm (160 mils). Linear range begins at approximately 0.5 mm (20 mils) from target and is from
0.5 to 4.5 mm (20 to 180 mils) (approximately –1 to –17 Vdc). Extended Deviation from Straight Line (DSL) range is from approximately 0.5 to 5.0 mm (20 to 200 mils) (–1 to –19 Vdc). The extended DSL range is not applicable when using zener barriers.
2.5 mm (100 mils)
3.94 V/mm (100 mV/mil) ±10% including interchangeability error when measured in increments of
0.5 mm (20 mils) over the 4.0 mm (160 mil) linear range.
Less than ±0.10 mm (±4 mils).
Less than ±0.15 mm (±6 mils).
Over a probe temperature range of
-35°C to +120°C (-31°F to +248°F) with the Proximitor Sensor and extension cable between 0°C to +45°C (+32°F to +113°F), the ISF remains within ±25% of 3.94 V/mm (100 mV/mil), the DSL remains within ±0.51 mm (±20 mils) and the extended range DSL remains within ±0.59 mm (±23 mils)
Over a Proximitor Sensor and extension cable temperature range of -35°C to +65°C (-31°F to +149°F) with the probe between 0°C to +45°C (+32°F to +113°F), the ISF remains within ±25% of 3.94 V/mm
3/25
3300 XL 11mm Proximity Transducer System Datasheet 146256 Rev. K
(100 mV/mil), the DSL remains within ±0.51 mm (±20 mils) and the extended range DSL remains within ±0.59 mm (±23 mils)
Frequency Response
Recommended Minimum Target Size
Recommended Minimum Shaft Diameter
0 to 8 kHz: +0, -3 dB typical, with up to 305 meters (1000 feet) of field wiring.
30.5 mm (1.2 in) diameter (flat target)
152 mm (6.0 in)
Measurements on shaft diameters smaller than 76 mm (3.0 in) usually require close spacing of radial vibration or axial position transducers with the potential for their electromagnetic emitted fields to interact with one another (cross talk), resulting in erroneous readings. Care should be taken to maintain minimum separation of transducer tips, generally at least 64 mm (2.5 in) for dual axial position measurements or 54 mm (2.1 in) for radial vibration measurements to prevent cross talk. Radial vibration or position measurements on shaft diameters smaller than 152 mm (6.0 in) will generally result in a change in scale factor due to the curvature of the shaft surface. Consult Performance Specification, document 144979, for additional information.
Effects of 60 Hz Magnetic Fields Up to 300 Gauss
(5 meter system)
Output voltage in mil pp/gauss
Gap
0.5 mm (20 mil)
2.5 mm (100 mil)
4.6 mm (180 mil)
Proximitor Sensor
0.006 0.001 0.001
0.033 0.009 0.005
0.033 0.027 0.007
Probe Ext. Cable
Mechanical
cable in the following total probe lengths: 1, 5 or 9 meters.
Extension Cable Material
Proximitor Sensor Material
System Length
Extension Cable Armor (optional)
Tensile Strength (maximum rated)
Connector Material
Probe Case Torque
Maximum Rated Recommended 1/2-20 and
5/8-18 probe cases
M14x1.5 and M16x1.5 probe cases
Reverse mount probes
Connector-to-connector torque
Recommended torque
Maximum torque
Minimum Bend Radius (with or without SST armor)
System Weight (typical)
Probe
70 g (2.5 oz) (minimum length case, 1m lead, no armor)
170 g (6.0 oz) (minimum length case, 1m lead, with armor)
75 Ω triaxial, fluoroethylene propylene (FEP) insulated.
A380 aluminum
5 or 9 meters including extension cable
Flexible AISI 302 SST with FEP outer jacket.
330 N (75 pounds) probe case to probe lead. 270 N (60 pounds) at probe lead to extension cable connectors.
Gold-plated brass
45.2 N•m
(400 in•lb)
63.3 N•m
(560 in•lb)
22.6 N•m
(200 in•lb)
Finger tight
0.565 N·m (5 in·lb)
25.4 mm (1.0 in)
15.2 N•m
(133 in•lb)
21.1 N•m
(187 in•lb)
7.5 N•m
(66 in•lb)
Probe Tip Material
Probe Case Material
Probe Cable Specification
Polyphenylene sulfide (PPS).
AISI 304 stainless steel (SST).
75 Ω triaxial, fluoroethylene propylene (FEP) insulated probe
For longer case lengths add 1.1 g/mm (1.0 oz/in).
For 5 m probe length add 180 g (6 oz) for non­armored probe or 560 g (20 oz) for armored probe.
For 9 m probe length add 360 g (12 oz) for non­armored probe or 1120 g (40 oz) for armored probe.
4/25
3300 XL 11mm Proximity Transducer System Datasheet 146256 Rev. K
Extension Cable
Armored Extension Cable
Proximitor Sensor
45 g/m (0.5 oz/ft)
140 g/m (1.5 oz/ft)
255 g (9 oz)
Environmental Limits
Probe Temperature Range
Operating and Storage Temperature
Exposing the probe to temperatures below ­34°C (30°F) may cause premature failure of the pressure seal.
Extension Cable Temperature Range
Operating and Storage Temperature
Proximitor Sensor Temperature Range
Operating Temperature
Storage Temperature
Relative Humidity
Probe Pressure
-52°C to +177°C (62°F to +351°F)
-52°C to +177°C (62°F to +351°F)
-52°C to +100°C (62°F to +212°F)
-52°C to +105°C (62°F to +221°F)
100% condensing, non-submersible when connectors are protected. Tested to IEC 68-2-3 damp heat.
3300 XL probes are designed to seal differential pressure between the probe tip and case. The probe sealing material consists of a Viton O-ring. Probes are not pressure tested prior to shipment. Contact our custom design department if you require a test of the pressure seal for your application
It is the responsibility of the customer or user to ensure that all liquids and gases are contained and safely controlled should leakage occur from a proximity probe. In addition, solutions with high or low pH values may erode the tip assembly of the probe causing media leakage into surrounding areas. Bently Nevada, LLC not be held responsible for any damages resulting from leaking 3300 XL proximity probes. In addition, 3300 XL proximity probes will not be replaced under the service plan due to probe leakage.
5/25
3300 XL 11mm Proximity Transducer System Datasheet 146256 Rev. K
or when

Compliance and Certifications

FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
l This device may not cause harmful
interference.
l This device must accept any
installed with galvanic isolators.
nA, ec
When installed without barriers per drawing
140979.
Class I, Zone 2: AEx/Ex nA IIC T4/T5 Gc; Class I, Division 2, Groups A, B, C, and D; Class I, Zone 2: AEx/Ex ec llC T4/T5 Gc; Class I, Division 2, Groups A, B, C, and D;
 T5 @ Ta= -55°C to + 40°C T4 @ Ta= -55°C to + 80°C
interference received, including interference that may cause
3300 XL Probe
undesired operation.
EMC
EN 61000-6-2
EN 61000-6-4
EMC Directive 2014/30/EU
RoHS
RoHS Directive 2011/65/EU
Maritime
ABS 2009 Steel Vessels Rules
1-1-4/7.7,4-8-3/1.11.1,4-9-7/13

Hazardous Area Approvals

For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from
Bently.com.
CSA/NRTL/C
ia
When installed with intrinsically safe zener barriers per drawing 141092 or when installed with galvanic isolators.
nA, ec
When installed without barriers per drawing
140979.
Class I, Zone 0: AEx/Ex ia IIC T5...T1 Ga; Class 1, Groups A, B. C, and D, Class II, Groups E, F, and G, Class III;  (see Temperature Schedule table to follow)
Class I, Zone 2: AEx/Ex nA IIC T5…T1 Gc; Class 1, Division 2, Groups A, B, C, D; Class 1, Zone 2: AEx/Ex ec llC T5…T1 Gc; Class I, Division 2, Groups A, B, C, and D;
(see Temperature Schedule table to follow)
3300 XL Proximitor Sensor
ia
When installed with intrinsically safe zener barriers per drawing 141092
Class I, Zone 0: AEx/Ex ia IIC T4/T5 Ga; Class I, Groups A, B, C, and D, Class II, Groups E, F and G, Class III;  T5 @ Ta= -55°˚C to + 40°˚C. T4 @ Ta= -55°˚C to + 80°C.
6/25
3300 XL 11mm Proximity Transducer System Datasheet 146256 Rev. K
ATEX/IECEx
3300 XL Proximitor Sensor
II 1 G
Ex ia IIC T4/T5 Ga Ex ia IIIC T90C/T105C Dc For EPL Dc:
T105C @ Ta = -55°C to 100°C T90C @ Ta = -55°C to +85°C
ia
nA,ec
Ui= -28V Uo= -28V
Ii= 140mA Io= 140mA
Pi= 0.91W Po= 0.742W
Ci- 47nF Co= 1.5nF
Li= 1460µH Lo= 610µH
II 3 G
Ex nA IIC T4/T5 Gc Ex ec llC T4/T5 Gc
Ui= -28V li= 140 mA
T5 @ Ta= -55˚ C to + 40˚C T4 @ Ta= -55 ˚C to + 80˚C
Ui= -28V li= 140 mA
Temperature Schedule
Temperature Classification
For EPL Ga and Gc
T1 -55°C to +232°C
T2 -55°C to +177°C
T3 -55°C to +120°C
T4 -55°C to +80°C
T5 -55°C to +40°C
For EPL Dc
T280°C @ Ta -55°C to +232°C
T225°C @ Ta -55°C to +177°C
T170°C @ Ta -55C to +120°C
T130°C @ Ta -55°C to +80°C
T105°C @ Ta -55°C to +100°C
Ambient Temperature
(Probe Only)
3300 XL Probe
Probe entity parameters are met when used with BN extension cables and connected to BN Prox.
ia
nA,ec
T90°C @ Ta -55°C to +40°C
II 1 G
Ex ia IIC T5…T1 Ga, (see Temperature Schedule table to follow)
Ex ia IIIC T90°C ... T280°C Dc For EPL Dc:
Ui= -28V Ci = 1.5 nF
Ii = 140 mA Li =610 μ H
Pi = 0.91 W
II 3 G
Ex nA IIC T5…T1 Gc, Ex ec llC T5…T1 Gc, (see Temperature Schedule table to follow)
7/25
3300 XL 11mm Proximity Transducer System Datasheet 146256 Rev. K

Hazardous Area Conditions of Safe Use

CSA/NRTL/C:
ia
Install per Bently Nevada drawing 141092.
nA, ec
Install per Bently Nevada drawing 140979.
ATEX/IECEx:
ia
Install per Bently Nevada drawing 141092.
nA, ec
The Prox must be installed so as to provide the terminals with a degree of protection of at least IP54.
8/25
Loading...
+ 17 hidden pages