The 3300 XL 11 mm Proximity Transducer System consists of:
l 3300 XL 11 mm probe
l 3300 XL 11 mm extension cable
l 3300 XL 11 mm Proximitor Sensor
The 3300 XL 11 mm Proximity Transducer System has a 3.94
V/mm (100 mV/mil) output for non-contacting vibration and
displacement measurements on fluid film bearing machines.
The large 11 mm tip enables this transducer system to have a
longer linear range compared to our standard 3300 XL 8 mm
Transducer System. It is primarily used in the following
applications where the longer linear range is necessary:
l Axial (thrust) position measurements
l Ramp differential expansion measurements on steam
turbines
l Rod position or rod drop measurements on
reciprocating compressors
l Tachometer and zero speed measurements
l Phase reference (Keyphasor) signals
146256 Rev. K
1
The 3300 XL 11 mm Proximitor Sensor is designed to replace
the 7200-series 11 mm and 14 mm Transducer Systems. When
upgrading from the 7200-series system to the 3300 XL 11 mm
system, every component must be replaced with 3300 XL 11
mm components. In addition, the monitoring system must
be updated. If using a 3500 Monitoring System, an updated
version of the configuration software that lists the 3300 XL 11
mm Transducer System as a compatible option is required.
Existing 3300 Monitoring Systems may need a modification.
Contact your local sales and service representative for
assistance.
3300 XL 11mm Proximity Transducer System
Datasheet146256 Rev. K
The 3300 XL 11 mm Proximity Transducer
is designed for measuring position or
vibration within a frequency range of 0
to 8 kHz. Typical applications of this
system include radial vibration and
position, axial position and Keyphasor
measurements.
Although the terminals and connector
on the Proximitor sensor have
protection against electrostatic
discharge, take reasonable precautions
to avoid electrostatic discharge during
handling.
Proximitor Sensor
The 3300 XL 11 mm Proximitor Sensor has the
same advanced features found in the 3300 XL 8
mm Proximitor Sensor. Its thin design allows it
to be mounted in either a high-density DIN-rail
installation or a more traditional panel mount
configuration. Improved RFI/EMI immunity
allows the 3300 XL Proximitor Sensor to achieve
European CE mark approvals without any
special mounting considerations. This RFI
immunity also prevents the transducer system
from being adversely affected by nearby high
frequency radio signals. SpringLoc terminal
strips on the Proximitor Sensor require no
special installation tools and facilitate faster,
highly robust field wiring connections.
3300 XL Probes and Extension Cables can also
be ordered with a FluidLoc cable option. This
option prevents oil and other liquids from
leaking out of the machine through the cable’s
interior. The connector protector option
provides additional protection of the
connectors in a humid or moist environment.
Connector protectors are recommended for all
installations and provide increased
environmental protection2. Additionally, the
3300 XL 11 mm probe comes standard with a
locknut with pre-drilled safety wire holes.
Notes:
1. Proximitor Sensors are supplied by
default from the factory calibrated to AISI
4140 steel. Calibration to other target
materials is available upon request.
2. Silicone tape is also provided with each
3300 XL extension cable and can be used
instead of connector protectors. Silicone
tape is not recommended in applications
where the probe-to-extension cable
connection will be exposed to turbine oil.
Proximity Probe and Extension Cable
The 3300 XL 11 mm probe comes in varying
probe case configurations, including armored
and unarmored ½-20, 5⁄8 -18, M14 X 1.5 and M16 X
1.5 probe threads. The reverse mount 3300 XL 11
mm probe comes standard with either 3⁄8 -24
or M10 X 1 threads. All components of the
transducer system have gold-plated brass
ClickLoc connectors. ClickLoc connectors lock
into place, preventing the connection from
becoming loose. The patented TipLoc molding
method provides a robust bond between the
probe tip and the probe body. The probe cable
is securely attached to the probe tip utilizing
our patented CableLoc design that provides
330 N (75 lb) pull strength.
2/25
3300 XL 11mm Proximity Transducer System
Datasheet146256 Rev. K
Extension
Specifications
Unless otherwise noted, the following
specifications are for a 3300 XL 11 mm Proximitor
Sensor, extension cable and probe between 0°C
and +45°C (+32°F to +113°F), with a -24 Vdc
power supply, a 10 kW load, our supplied AISI
4140 steel target that is 31 mm (1.2 in) diameter
or larger, and a probe gap of 2.5 mm (100 mils).
The system accuracy and interchangeability
specifications do not apply when using a
transducer system calibrated to any target
other than our AISI 4140 steel target.
Electrical
Proximitor Sensor
Accepts one non-contacting 3300 XL
Input
Power
Supply
Sensitivity
Output
resistance
Probe dc Resistance
Probe Length
(m)
1.05.9 ± 0.5
5.07.2 ± 0.8
9.08.5 ± 1.1
Length of
Extension
Cable
(m)
4.01.0 ± 0.250.3 ± 0.1
8.02.0 ± 0.50.6 ± 0.2
11 mm Proximity Probe and Extension
Cable.
Requires -17.5 Vdc to -26 Vdc
without barriers at 12 mA maximum
consumption, -23 Vdc to -26 Vdc
with barriers. Operation at a more
positive voltage than -23.5 Vdc can
result in reduced linear range.
Less than 2 mV change in output
voltage per volt change in input
voltage.
50 Ω
Resistance from the Center
Conductor to the Outer Conductor
(R
Extension Cable dc Resistance
Resistance from
Center Conductor
to Center
Conductor (R
(ohms)
PROBE
) (ohms)
CORE)
Resistance from
Coaxial Conductor
to Coaxial
Conductor
(R
JACKET
) (ohms)
cable
capacitance
Field wiring
Linear Range
Recommended
Gap Setting
Incremental
Scale Factor
(ISF)
Deviation from best fit straight line (DSL)
Standard DSL
range
Extended DSL
range
System
Performance
over extended
temperatures
69.9 pF/m (21.3 pF/ft) typical
0.2 to 1.5 mm2 (16 to 24 AWG) [0.25
to 0.75 mm2 (18 to 23 AWG) with
ferrules]. Recommend using threeconductor shielded triad cable.
Maximum length of 305 meters
(1,000 feet) between the 3300 XL
Proximitor Sensor and the monitor.
See the frequency response graph
for signal rolloff at high frequencies
when using longer field wiring
lengths.
4.0 mm (160 mils). Linear range
begins at approximately 0.5 mm
(20 mils) from target and is from
0.5 to 4.5 mm (20 to 180 mils)
(approximately –1 to –17 Vdc).
Extended Deviation from Straight
Line (DSL) range is from
approximately 0.5 to 5.0 mm (20 to
200 mils) (–1 to –19 Vdc). The
extended DSL range is not
applicable when using zener
barriers.
2.5 mm (100 mils)
3.94 V/mm (100 mV/mil) ±10%
including interchangeability error
when measured in increments of
0.5 mm (20 mils) over the 4.0 mm
(160 mil) linear range.
Less than ±0.10 mm (±4 mils).
Less than ±0.15 mm (±6 mils).
Over a probe temperature range of
-35°C to +120°C (-31°F to +248°F)
with the Proximitor Sensor and
extension cable between 0°C to
+45°C (+32°F to +113°F), the ISF
remains within ±25% of 3.94 V/mm
(100 mV/mil), the DSL remains
within ±0.51 mm (±20 mils) and the
extended range DSL remains within
±0.59 mm (±23 mils)
Over a Proximitor Sensor and
extension cable temperature range
of -35°C to +65°C (-31°F to +149°F)
with the probe between 0°C to
+45°C (+32°F to +113°F), the ISF
remains within ±25% of 3.94 V/mm
3/25
3300 XL 11mm Proximity Transducer System
Datasheet146256 Rev. K
(100 mV/mil), the DSL remains
within ±0.51 mm (±20 mils) and the
extended range DSL remains within
±0.59 mm (±23 mils)
Frequency
Response
Recommended
Minimum
Target Size
Recommended
Minimum Shaft
Diameter
0 to 8 kHz: +0, -3 dB typical, with up
to 305 meters (1000 feet) of field
wiring.
30.5 mm (1.2 in) diameter (flat
target)
152 mm (6.0 in)
Measurements on shaft diameters smaller than
76 mm (3.0 in) usually require close spacing of
radial vibration or axial position transducers
with the potential for their electromagnetic
emitted fields to interact with one another
(cross talk), resulting in erroneous readings.
Care should be taken to maintain minimum
separation of transducer tips, generally at least
64 mm (2.5 in) for dual axial position
measurements or 54 mm (2.1 in) for radial
vibration measurements to prevent cross talk.
Radial vibration or position measurements on
shaft diameters smaller than 152 mm (6.0 in)
will generally result in a change in scale factor
due to the curvature of the shaft surface.
Consult Performance Specification, document
144979, for additional information.
Effects of 60 Hz Magnetic Fields Up to 300 Gauss
(5 meter system)
Output voltage in mil pp/gauss
Gap
0.5 mm (20
mil)
2.5 mm (100
mil)
4.6 mm (180
mil)
Proximitor
Sensor
0.0060.0010.001
0.0330.0090.005
0.0330.0270.007
ProbeExt. Cable
Mechanical
cable in the following total probe
lengths: 1, 5 or 9 meters.
Extension
Cable Material
Proximitor
Sensor Material
System Length
Extension
Cable Armor
(optional)
Tensile
Strength
(maximum
rated)
Connector
Material
Probe Case Torque
Maximum Rated Recommended
1/2-20 and
5/8-18 probe
cases
M14x1.5 and
M16x1.5 probe
cases
Reverse mount
probes
Connector-to-connector torque
Recommended
torque
Maximum
torque
Minimum Bend
Radius (with or
without SST
armor)
System Weight (typical)
Probe
70 g (2.5 oz) (minimum length case, 1m lead, no
armor)
170 g (6.0 oz) (minimum length case, 1m lead, with
armor)
For 5 m probe length add 180 g (6 oz) for nonarmored probe or 560 g (20 oz) for armored probe.
For 9 m probe length add 360 g (12 oz) for nonarmored probe or 1120 g (40 oz) for armored probe.
4/25
3300 XL 11mm Proximity Transducer System
Datasheet146256 Rev. K
Extension
Cable
Armored
Extension
Cable
Proximitor
Sensor
45 g/m (0.5 oz/ft)
140 g/m (1.5 oz/ft)
255 g (9 oz)
Environmental Limits
Probe Temperature Range
Operating
and Storage
Temperature
Exposing the probe to temperatures below 34°C (30°F) may cause premature failure of
the pressure seal.
Extension Cable Temperature Range
Operating
and Storage
Temperature
Proximitor Sensor Temperature Range
Operating
Temperature
Storage
Temperature
Relative
Humidity
Probe
Pressure
-52°C to +177°C (62°F to +351°F)
-52°C to +177°C (62°F to +351°F)
-52°C to +100°C (62°F to +212°F)
-52°C to +105°C (62°F to +221°F)
100% condensing, non-submersible
when connectors are protected.
Tested to IEC 68-2-3 damp heat.
3300 XL probes are designed to seal
differential pressure between the
probe tip and case. The probe sealing
material consists of a Viton O-ring.
Probes are not pressure tested prior to
shipment. Contact our custom design
department if you require a test of the
pressure seal for your application
It is the responsibility of the customer or
user to ensure that all liquids and gases
are contained and safely controlled
should leakage occur from a proximity
probe. In addition, solutions with high or
low pH values may erode the tip
assembly of the probe causing media
leakage into surrounding areas. Bently
Nevada, LLC not be held responsible for
any damages resulting from leaking
3300 XL proximity probes. In addition,
3300 XL proximity probes will not be
replaced under the service plan due to
probe leakage.
5/25
3300 XL 11mm Proximity Transducer System
Datasheet146256 Rev. K
or when
Compliance and
Certifications
FCC
This device complies with part 15 of the
FCC Rules. Operation is subject to the
following two conditions:
l This device may not cause harmful
interference.
l This device must accept any
installed with
galvanic
isolators.
nA, ec
When installed
without
barriers per
drawing
140979.
Class I, Zone 2: AEx/Ex nA IIC T4/T5
Gc;
Class I, Division 2, Groups A, B, C,
and D;
Class I, Zone 2: AEx/Ex ec llC T4/T5
Gc;
Class I, Division 2, Groups A, B, C,
and D;
T5 @ Ta= -55°C to + 40°C
T4 @ Ta= -55°C to + 80°C
interference received, including
interference that may cause
3300 XL Probe
undesired operation.
EMC
EN 61000-6-2
EN 61000-6-4
EMC Directive 2014/30/EU
RoHS
RoHS Directive 2011/65/EU
Maritime
ABS 2009 Steel Vessels Rules
1-1-4/7.7,4-8-3/1.11.1,4-9-7/13
Hazardous Area Approvals
For the detailed listing of country and product
specific approvals, refer to the Approvals Quick Reference Guide (108M1756) available from
Bently.com.
CSA/NRTL/C
ia
When installed
with
intrinsically
safe zener
barriers per
drawing 141092
or when
installed with
galvanic
isolators.
nA, ec
When installed
without
barriers per
drawing
140979.
Class I, Zone 0: AEx/Ex ia IIC T5...T1
Ga;
Class 1, Groups A, B. C, and D,
Class II, Groups E, F, and G,
Class III;
(see Temperature Schedule table to
follow)
Class I, Zone 2: AEx/Ex nA IIC T5…T1
Gc;
Class 1, Division 2, Groups A, B, C, D;
Class 1, Zone 2: AEx/Ex ec llC T5…T1
Gc; Class I, Division 2, Groups A, B, C,
and D;
(see Temperature Schedule table to
follow)
3300 XL Proximitor Sensor
ia
When installed
with
intrinsically
safe zener
barriers per
drawing 141092
Class I, Zone 0: AEx/Ex ia IIC T4/T5
Ga;
Class I, Groups A, B, C, and D,
Class II, Groups E, F and G,
Class III;
T5 @ Ta= -55°˚C to + 40°˚C.
T4 @ Ta= -55°˚C to + 80°C.
6/25
3300 XL 11mm Proximity Transducer System
Datasheet146256 Rev. K
ATEX/IECEx
3300 XL Proximitor Sensor
II 1 G
Ex ia IIC T4/T5 Ga
Ex ia IIIC T90C/T105C Dc
For EPL Dc:
T105C @ Ta = -55°C to 100°C
T90C @ Ta = -55°C to +85°C
ia
nA,ec
Ui= -28V Uo= -28V
Ii= 140mAIo= 140mA
Pi= 0.91WPo= 0.742W
Ci- 47nFCo= 1.5nF
Li= 1460µHLo= 610µH
II 3 G
Ex nA IIC T4/T5 Gc
Ex ec llC T4/T5 Gc
Ui= -28V li= 140 mA
T5 @ Ta= -55˚ C to + 40˚C
T4 @ Ta= -55 ˚C to + 80˚C
Ui= -28V li= 140 mA
Temperature Schedule
Temperature
Classification
For EPL Ga and Gc
T1-55°C to +232°C
T2-55°C to +177°C
T3-55°C to +120°C
T4-55°C to +80°C
T5-55°C to +40°C
For EPL Dc
T280°C @ Ta-55°C to +232°C
T225°C @ Ta-55°C to +177°C
T170°C @ Ta-55C to +120°C
T130°C @ Ta-55°C to +80°C
T105°C @ Ta-55°C to +100°C
Ambient Temperature
(Probe Only)
3300 XL Probe
Probe entity parameters are met when
used with BN extension cables and
connected to BN Prox.
ia
nA,ec
T90°C @ Ta-55°C to +40°C
II 1 G
Ex ia IIC T5…T1 Ga,
(see Temperature Schedule
table to follow)
Ex ia IIIC T90°C ... T280°C Dc
For EPL Dc:
Ui= -28V Ci = 1.5 nF
Ii = 140 mALi =610 μ H
Pi = 0.91 W
II 3 G
Ex nA IIC T5…T1 Gc,
Ex ec llC T5…T1 Gc,
(see Temperature Schedule
table to follow)
7/25
3300 XL 11mm Proximity Transducer System
Datasheet146256 Rev. K
Hazardous Area Conditions of
Safe Use
CSA/NRTL/C:
ia
Install per Bently Nevada drawing 141092.
nA, ec
Install per Bently Nevada drawing 140979.
ATEX/IECEx:
ia
Install per Bently Nevada drawing 141092.
nA, ec
The Prox must be installed so as to provide the
terminals with a degree of protection of at least
IP54.
8/25