The 3300 XL 8 mm Proximity Transducer System consists of:
oOne 3300 XL 8 mm probe,
oOne 3300 XL extension cable1, and
oOne 3300 XL Proximitor Sensor2.
The system provides an output voltage that is directly proportional to the
distance between the probe tip and the observed conductive surface
and can measure both static (position) and dynamic (vibration) values.
The system’s primary applications are vibration and position
measurements on fluid-film bearing machines, as well as Keyphasor
reference and speed measurements3.
The 3300 XL 8 mm system delivers the most advanced performance in
our eddy current proximity transducer systems. The standard 3300 XL
8 mm 5-meter system also fully complies with the American Petroleum
Institute’s (API) 670 Standard (4th Edition) for mechanical configuration,
linear range, accuracy, and temperature stability. All 3300 XL 8 mm
proximity transducer systems provide this level of performance and
support complete interchangeability of probes, extension cables, and
Proximitor sensors, eliminating the need to match or bench calibrate
individual components.
141194 Rev. AH
Each 3300 XL 8 mm Transducer System component is backward
compatible and interchangeable4 with other non-XL 3300 series 5 mm
and 8 mm transducer system components5. This compatibility includes
the 3300 5 mm probe, for applications in which an 8 mm probe is too
large for the available mounting space
6,7
.
Proximitor Sensor
The 3300 XL Proximitor Sensor incorporates numerous improvements
over previous designs. Its physical packaging allows you to use it in
high-density DIN-rail installations. You can also mount the sensor in a
traditional panel mount configuration, where it shares an identical 4-hole
mounting “footprint” with older Proximitor Sensor designs. The
mounting base for either option provides electrical isolation and
Page 2
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
eliminates the need for separate isolator plates. The
3300 XL Proximitor Sensor is highly immune to radio
frequency interference, allowing you to install it in
fiberglass housings without adverse effects from
nearby radio frequency signals. The 3300 XL
Proximitor Sensor’s improved RFI/EMI immunity
satisfies European CE mark approvals without
requiring special shielded conduit or metallic housings,
resulting in lower installation costs and complexity.
The 3300 XL’s SpringLoc terminal strips require no
special installation tools and facilitate faster, more
robust field wiring connections by eliminating screwtype clamping mechanisms that can loosen.
standard 177 ˚C (350 ˚F) temperature specification. The
ETR probe has an extended temperature rating for up to
218 ˚C (425 ˚F). The ETR extension cable rating is up
to 260 ˚C (500 ˚F). Both the ETR probe and cable are
compatible with standard temperature probes and
cables, for example, you can utilize an ETR probe with
the 330130 extension cable. The ETR system uses the
standard 3300 XL Proximitor Sensor. Note that when
you use any ETR component as part of your system,
the ETR component limits the system accuracy to the
accuracy of the ETR system.
Description Notes:
Proximity Probe and Extension Cable
The 3300 XL probe and extension cable also reflect
improvements over previous designs. A patented
TipLoc molding method provides a more robust bond
between the probe tip and the probe body. The probe’s
cable incorporates a patented CableLoc design that
provides 330 N (75 lbf) pull strength to more securely
attach the probe cable and probe tip.
You can also order 3300 XL 8 mm probes and extension
cables with an optional FluidLoc cable option. This
option prevents oil and other liquids from leaking out of
the machine through the cable’s interior.
Connectors
The 3300 XL probe, extension cable, and Proximitor
sensor have corrosion-resistant, gold-plated ClickLoc
connectors. These connectors require only finger-tight
torque (the connectors will "click" when tight), and the
specially-engineered locking mechanism prevents the
connectors from loosening. These connectors require
no special tools for installation or removal.
You can order the 3300 XL 8 mm probes and extension
cables with connector protectors already installed. We
can also supply connector protectors separately for
field installations (such as when an application must
run the cable through restrictive conduit). We
recommend connector protectors for all installations to
provide increased environmental protection8.
Extended Temperature Range
Applications
An extended temperature range (ETR) probe and ETR
extension cable are available for applications in which
either the probe lead or extension cable may exceed the
1. One-meter systems do not use an extension cable.
2. Proximitor sensors are supplied by default from the
factory calibrated to AISI 4140 steel. Calibration to
other target materials is available upon request.
3. Consult Bently Nevada Applications Note,
Considerations when using Eddy Current Proximity
Probes for Overspeed Protection Applications, when
considering this transducer system for tachometer or
overspeed measurements.
4. 3300 XL 8 mm components are both electrically and
physically interchangeable with non-XL 3300 5 mm and
8 mm components. Although the packaging of the 3300
XL Proximitor Sensor differs from its predecessor, its
design fits in the same 4-hole mounting pattern when
used with the 4-hole mounting base, and will fit within
the same mounting space specifications (when
minimum permissible cable bend radius is observed).
5. Mixing XL and non-XL 3300-series 5 mm and 8 mm
system components limits system performance to the
specifications for the non-XL 3300 5 mm and 8 mm
Transducer System.
6. The 3300-series 5 mm probe (refer to Document
141605) uses smaller physical packaging, but does not
reduce the side view clearances or tip-to-tip spacing
requirements as compared to an 8mm probe. It is used
when physical (not electrical) constraints preclude the
use of an 8mm probe. When your application requires
narrow side view probes, use the 3300 NSv Proximity
Transducer System (refer to Document 147385).
7. 8 mm probes provide a thicker encapsulation of the
probe coil in the molded PPS plastic probe tip. This
results in a more rugged probe. The larger diameter of
the probe body also provides a stronger, more robust
case. We recommend that you use 8 mm probes when
2/41
Page 3
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
possible to provide optimal robustness against physical
abuse.
8. Each 3300 XL extension cable includes silicone tape
that you can use instead of connector protectors. We
do not recommend silicone tape for applications that
will expose the probe-to-extension cable connection to
turbine oil.
3/41
Page 4
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Specifications
Unless otherwise noted, the following specifications
are for a 3300 XL 8 mm Proximitor Sensor, extension
cable and 8 mm probe between +18 ˚C and +27 ˚C (+64
˚F to +80 ˚F), with a -24 Vdc power supply, a 10 kΩ
load, an AISI 4140 steel target, and a probe gapped at
1.27 mm (50 mils). Performance characteristics apply
to systems that consist solely of 3300 XL 8 mm
components. The system accuracy and
interchangeability specifications do not apply to
transducer systems that are calibrated to any target
other than our AISI 4140 steel target.
Electrical
Proximitor
Sensor Input
PowerRequires -17.5 Vdc to -26 Vdc
Supply
Sensitivity
Output
Resistance
Accepts one non-contacting 3300series 5mm, 3300 XL 8mm
Proximity Probe and Extension
Cable.
without barriers at 12 mA maximum
consumption, -23 Vdc to -26 Vdc
with barriers. Operation at a more
positive voltage than -23.5 Vdc can
result in reduced linear range.
Less than 2 mV change in output
voltage per volt change in input
voltage.
50 Ω
2.0
3.0
7.88±0.50
8.17±0.50
5.08.73±0.50
9.09.87±0.50
Nominal Extension Cable DC Resistance
Resistance
(R
) from Center Conductor to
CORE
Center Conductor
Length of
RCORE (Ω)
Extension
Cable
(m)
3.00.66±0.10
3.50.77±0.12
4.00.88±0.13
4.50.99±0.15
6.01.32±0.21
7.01.54±0.23
7.51.65±0..25
8.01.76±0.26
8.51.87±0.28
Nominal Probe DC Resistance
Resistance
(R
PROBE
) from Center Conductor to
Outer Conductor)
Probe
R
PROBE
Length
(m)
0.57.45±0.50
1.0
1.5
7.59±0.50
7.73±0.50
(Ω)
Resistance (R
Outer Conductor
4/41
JACKET
) from Outer Conductor to
Length of
R
JACKET
Extension
Cable
(m)
3.00.20±0.04
3.50.23±0.05
4.00.26±0.05
4.50.30±0.06
6.00.39±0.08
(Ω)
Page 5
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
7.00.46±0.09
7.5
0.49±0.10
8.00.53±0.11
8.50.56±0.11
Extension
69.9 pF/m (21.3 pF/ft) typical
Cable
Capacitance
Field Wiring0.2 to 1.5 mm2 (16 to 24 AWG) .
Recommend using 3 conductor
shielded triad cable and tinned field
wiring. Maximum length of 305
meters (1,000 feet) between the
3300 XL Proximitor Sensor and the
monitor. See the frequency
response graphs, Figures 10 and
12, for signal rolloff at high
frequencies when using longer field
wiring lengths.
Linear Range2 mm (80 mils). Linear range begins
at approximately 0.25 mm (10 mils)
from target and is from 0.25 to 2.3
mm (10 to 90 mils) (approximately –
1 to –17 Vdc).
Extended
Temperature
Range (ETR)
for 5 and 9
Meter Systems
7.87 V/mm (200 mV/mil) ± 6.5%
including interchangeability error
when measured in increments of
0.25 mm (10 mils) over the 80 mil
linear range from 0 °C to +45 °C
(+32 °F to +113 °F).
Deviation from best fit straight line (DSL)
Standard 5 or 1
meter System
Less than ±0.025 mm (±1 mil) with
components at 0 °C to +45 °C (+32
°F to +113 °F).
Standard 9
meter System
Less than ±0.038 mm (±1.5 mil)
with components at 0 °C to +45 °C
(+32 °F to +113 °F).
Extended
Temperature
Range 5 and 9
Less than ±0.038 mm (±1.5 mil)
with components at 0 °C to +45 °C
(+32 °F to +113 °F).
meter Systems
Performance over Extended Temperatures
Standard 5 or 1
meter System
Over a probe temperature range of –
35 °C to +120 °C (-31 °F to +248 °F)
with the Proximitor sensor and
extension cable between 0 °C to
+45°C (+32 °F to +113 °F), the ISF
remains within ±10% of 7.87 V/mm
(200 mV/mil) and the DSL remains
within ±0.076 mm (±3 mils).
Recommended
Gap Setting for
Radial
Vibration
Incremental Scale Factor (ISF)
Standard 5 or 1
meter System
Standard 9
meter System
-9 Vdc [approximately 1.27 mm (50
mils)]
7.87 V/mm (200 mV/mil) ± 5%
including interchangeability error
when measured in increments of
0.25 mm (10 mils) over the 80 mil
linear range from 0 °C to +45 °C
(+32 °F to +113 °F).
7.87 V/mm (200 mV/mil) ± 6.5%
including interchangeability error
when measured in increments of
0.25 mm (10 mils) over the 80 mil
linear range from 0 °C to +45 °C
(+32 °F to +113 °F).
Standard 9
meter System
Over a Proximitor sensor and
extension cable temperature range
of –35 °C to +65 °C (-31 °F to +149
°F) with the probe between 0 °C to
+45 °C (+32 °F to +113 °F), the ISF
remains within ±10% of 7.87 V/mm
(200 mV/mil) and the DSL remains
within ±0.076 mm (±3 mils).
Over a probe temperature range of
–35 °C to +120 °C (-31 °F to +248
°F) with the Proximitor sensor and
extension cable between 0 °C to
+45°C (+32 °F to +113 °F), the ISF
remains within ±18% of 7.87 V/mm
(200 mV/mil) and the DSL remains
within ±0.152 mm (±6 mils).
Over a Proximitor sensor and
5/41
Page 6
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
extension cable temperature range
of –35 °C to +65 °C (-31 °F to +149
°F) with the probe between 0 °C to
+45 °C (+32 °F to +113 °F), the ISF
remains within ±18% of 7.87 V/mm
(200 mV/mil) and the DSL remains
within ±0.152 mm (±6 mils).
Extended
Temperature
Range 5 and 9
meter Systems
Frequency
Response
Minimum
Target Size
Minimum50.8 mm (2 in)
Recommended
Minimum
When gapped at the center of the linear
range, the interaction between two separate
transducer systems (cross-talk) will be less
than 50 mV on shaft diameters of at least 50
mm (2 in) or greater. You should take care to
maintain minimum separation of transducer
tips, generally at least 40 mm (1.6 in) for axial
position measurements or 38 mm (1.5 in) for
radial vibration measurements to limit crosstalk to 50 mV or less. Radial vibration or
position measurements on shaft diameters
smaller than 76.2 mm (3 in) will generally
change the scale factor.
Effects of 60 Hz Magnetic Fields Up to 300 Gauss
Output Voltage in Mil pp/Gauss
Gap
5 or 1-meter
Over a probe and extension cable
temperature range of –35 °C to +260
°C (-31 °F to +500 °F) with the
Proximitor sensor between 0 °C to
+45 °C (+32 °F to +113 °F), the ISF
remains within ±18% of 7.87 V/mm
(200 mV/mil) and the DSL remains
within ±0.152 mm (±6 mils).
(0 to 10 kHz), +0, -3 dB, with up to
305 meters (1000 feet) of field
wiring.
15.2 mm (0.6 in) diameter (flat
target)
Shaft Diameter
76.2 mm (3 in)
9 meter ProbeExt.
Proximitor
Sensor
100.0119
500.0131
900.0133
Proximitor
Sensor
0.02470.0004 0.0004
0.03230.0014 0.0014
0.03480.0045 0.0045
Mechanical
Probe Tip MaterialPolyphenylene sulfide (PPS).
Probe Case
Material
Probe Cable Specifications
Standard cable75Ω triaxial, fluoroethylene
Extended
Temperature
Range cable
Armor (optional on
both)
Tensile Strength
(Maximum Rated)
Connector
Material
Probe Case Torque
Probe TypeMaximum
Standard forward
mounted probes
Standard forwardmount probes first three threads
Reverse-mount
probes
AISI 303 or 304 stainless steel
(SST).
propylene (FEP) insulated probe
cable in the following total probe
lengths: 0.5, 1, 1.5, 2, 3, 5, or 9
meters.
75Ω triaxial, perfluoroalkoxy
(PFA) insulated probe cable in
the following total probe lengths:
0.5, 1, 1.5, 2, 5, or 9 meters.
Flexible AISI 302 or 304 SST
with FEP outer jacket.
330 N (75 lbf) probe case to
probe lead.
270 N (60 lbf) at probe lead to
extension cable connectors.
Gold-plated brass or gold-plated
beryllium copper.
Recommended
Rated
33.9 N•m
(300 in•lbf)
22.6 N•m
(200 in•lbf)
22.6 N•m
(200 in•lbf)
11.2 N•m (100
in•lbf)
7.5 N•m (66
in•lbf)
7.5 N•m (66
in•lbf)
Cable
6/41
Page 7
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Extension Cable Material
Standard cable75 Q triaxial, fluoroethylene
propylene (FEP) insulated
Extended
Temperature
Range cable
Minimum Cable
Bend Radius
3300 XL 8 mm components are both
electrically and physically interchangeable
with non-XL 3300 5 mm and 8 mm
components when minimum permissible
cable bend radius is observed.
Connector
Material
Maximum
Connector Torque
Connector-to-Connector Recommended Torque
Connector TypeTightening Instructions
75Ω triaxial, perfluoroalkoxy
(PFA) insulated.
25.4 mm (1.0 in)
Gold-plated brass or gold-plated
beryllium copper.
0.565 N•m (5 in•lbf)
Probe 323 g/m (11.4
oz.)
Extension
Cable
Armored
Extension
Cable
Proximitor
Sensor
34 g/m (0.4
oz/ft)
103 g/m (1.5
oz/ft)
246 g (8.67 oz)
Environmental Limits
Probe Temperature Range
Operating and Storage Temperature
Standard Probe
-52 °C to +177 °C (-62 °F to
+350 °F)
Extended
Temperature Range
Probe
-52°C to +218°C (-62°F to
+425°F) for the probe tip; -51°C
to +260°C (-60°F to +500°F) for
the probe cable and connector.
Two 3300 XL gold
"click" type
connectors
One non-XL
stainless steel
connector and one
3300 XL connector
Proximitor Sensor
Material
Connector
Material
System Length5 or 9 meters (including
Total System
Weight (TypicaI)
Finger tight
Finger tight plus 1/8 turn using
pliers
A308 aluminum
Gold-plated brass or goldplated beryllium copper.
extension cable) or 1 meter
(probe only).
0.7 kg (1.5 lb m)
Exposing the probe to temperatures below –
34 ˚C (-30 ˚F) may cause premature failure of
the pressure seal.
Probe Pressure
3300 XL 8 mm probes are designed to seal
differential pressure between the probe tip and case.
The probe sealing material consists of a Viton® O
ring. Probes are not pressure tested prior to
shipment. Contact our custom design department if
you require a test of the pressure seal for your
application.
It is the responsibility of the customer or user
to ensure that all liquids and gases are
contained and safely controlled should
leakage occur from a proximity probe. In
addition, solutions with high or low pH values
may erode the tip assembly of the probe
causing media leakage into surrounding
areas. Bently Nevada, LLC will not be held
7/41
Page 8
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
responsible for any damages resulting from
leaking 3300 XL 8 mm proximity probes. In
addition, 3300 XL 8 mm proximity probes will
not be replaced under the service plan due to
probe leakage.
Extension Cable Temperature Range
Operating and Storage Temperature
Standard Cable-52°C to +177°C
(-62°F to +350 °F)
Extended
Temperature Range
-52°C to +260 °C (-62 °F to
+500 °F)
Cable
Proximitor Sensor Temperature Range
Operating
Temperature
Storage
Temperature
-52°C to +100°C (-62°F to
+212°F)
52 °C to +105 °C (-62 °F to
+221 °F)
Probe Relative Humidity
Less than a 3% change in Average Scale Factor
(ASF) when tested in 93% humidity in accordance
with IEC standard 68 2 3 for up to 56 days.
8/41
Page 9
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Compliance and Certifications
FCC
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
l This device may not cause harmful
interference.
l This device must accept any interference
received, including interference that may
cause undesired operation.
EMC
EN 61000-6-2
EN 61000-6-4
EMC Directive 2014/30/EU
RoHS
RoHS Directive 2011/65/EU
Maritime
ABS 2009 Steel Vessels Rules
1-1-4/7.7,4-8-3/1.11.1,4-9-7/13
9/41
Page 10
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
with galvanic
Hazardous Area Approvals
For the detailed listing of country and product
specific approvals, refer to the
Quick Reference Guide
from Bently.com.
CSA/NRTL/C
(108M1756) available
Approvals
isolators.
nA, ec
When installed
without
barriers per
drawing
140979.
Class I, Zone 2: AEx/Ex nA IIC
T5…T1 Gc;
Class 1, Division 2, Groups A, B, C,
D;
Class 1, Zone 2: AEx/Ex ec llC
T5…T1 Gc; Class I, Division 2,
Groups A, B, C, and D;
3300 XL Proximitor Sensor
ia
When installed
with
intrinsically
safe zener
barriers per
drawing
141092 or
when installed
with galvanic
isolators.
nA, ec
When installed
without
barriers per
drawing
140979.
Class I, Zone 0: AEx/Ex ia IIC
T4/T5 Ga;
Class I, Groups A, B, C, and D,
Class II, Groups E, F and G,
Class III;
T5 @ Ta= -55°˚C to + 40°˚C.
T4 @ Ta= -55°˚C to + 80°C.
Class I, Zone 2: AEx/Ex nA IIC
T4/T5 Gc;
Class I, Division 2, Groups A, B, C,
and D;
Class I, Zone 2: AEx/Ex ec llC
T4/T5 Gc;
Class I, Division 2, Groups A, B, C,
and D;
(see Temperature Schedule table to
follow)
3300 XL Probe
ia
When installed
with
intrinsically
safe zener
barriers per
drawing
141092 or
when installed
T5 @ Ta= -55°C to + 40°C
T4 @ Ta= -55°C to + 80°C
Class I, Zone 0: AEx/Ex ia IIC
T5...T1 Ga;
Class 1, Groups A, B. C, and D,
Class II, Groups E, F, and G,
Class III;
(see Temperature Schedule table to
follow)
10/41
Page 11
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
ATEX/IECEx
3300 XL Proximitor Sensor
ia
nA,ec
3300 XL Probe
II 1 G
Ex ia IIC T4/T5 Ga
Ex ia IIIC T90C/T105C Dc
For EPL Dc:
T105C @ Ta = -55°C to 100°C
T90C @ Ta = -55°C to +85°C
Ui= -28V Uo= -28V
Ii= 140mAIo= 140mA
Pi= 0.91WPo= 0.742W
Ci- 47nFCo= 1.5nF
Li= 1460µHLo= 610µH
II 3 G
Ex nA IIC T4/T5 Gc
Ex ec llC T4/T5 Gc
Ui= -28V li= 140 mA
T5 @ Ta= -55˚ C to + 40˚C
T4 @ Ta= -55 ˚C to + 80˚C
nA,ec
II 3 G
Ex nA IIC T5…T1 Gc,
Ex ec llC T5…T1 Gc,
(see Temperature Schedule
table to follow)
Ui= -28V li= 140 mA
Temperature Schedule
Temperature
Classification
For EPL Ga and Gc
T1-55°C to +232°C
T2-55°C to +177°C
T3-55°C to +120°C
T4-55°C to +80°C
T5-55°C to +40°C
For EPL Dc
T280°C @ Ta-55°C to +232°C
T225°C @ Ta-55°C to +177°C
T170°C @ Ta-55C to +120°C
T130°C @ Ta-55°C to +80°C
Ambient Temperat ure (Probe
Only)
Probe entity parameters are met when used
with BN extension cables and connected to BN
Prox.
ia
II 1 G
Ex ia IIC T5…T1 Ga,
(see Temperature Schedule
table to follow)
Ex ia IIIC T90°C ... T280°C Dc
For EPL Dc:
Ui= -28V Ci = 1.5 nF
Ii = 140 mALi =610 μH
Pi = 0.91 W
T105°C @ Ta-55°C to +100°C
T90°C @ Ta-55°C to +40°C
11/41
Page 12
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Hazardous Area Conditions of
Safe Use
CSA/NRTL/C:
ia
Install per Bently Nevada drawing 141092.
nA, ec
Install per Bently Nevada drawing 140979.
ATEX/IECEx:
ia
Install per Bently Nevada drawing 141092.
nA, ec
The Prox must be installed so as to provide the
terminals with a degree of protection of at least IP54.
12/41
Page 13
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Ordering Information
For the detailed listing of country and product
specific approvals, refer to the
Quick Reference Guide
from Bently.com.
(108M1756) available
Ordering Information for Probes
3300 XL 8 mm Proximity Probes:
330101 3300 XL 8 mm Probe, 3/8-24 UNF thread,
without armor
330102 3300 XL 8 mm Probe, 3/8-24 UNF thread,
with armor
Part Number-AA-BB-CC-DD-EE
A: Unthreaded Length Option
Order in increments of 0.1 in.
Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
Example: 0 4 = 0.4 in.
(2)
(2)
Unthreaded length must be at least 0.8 in.
less than the case length.
Approvals
90
D: Connector and Cable-Type Option
01
02Miniature coaxial ClickLoc connector,
11Miniature coaxial ClickLoc connector with
12Miniature coaxial ClickLoc connector,
E: Agency Approval Option
00
05
9.0 meters (29.5 feet)
3-meter length option is only available on
330101 probes, and is designed for use with
the 9 meter Proximitor sensor only.
5-meter probes are designed for use with the
5 meter Proximitor sensor only.
Miniature coaxial ClickLoc connector with
connector protector, standard cable
standard cable
connector protector, FluidLoc cable
FluidLoc cable
Not required
CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes, Metric:
B: Overall Case Length Option
Order in increments of 0.1 in.
Standard thread configurations:
Maximum case length: 9.6 in.
Minimum case length: 0.8 in.
Example: 2 4 = 2.4 in.
C: Total Length Option
050.5 meter (1.6 feet)
10
151.5 meter (4.9 feet)
20
303.0 meters (9.8 feet)
50
1.0 meter (3.3 feet)
2.0 meters (6.6 feet)
5.0 meters (16.4 feet)
330103 3300 XL 8 mm Probe, M10 x 1 thread,
without armor
330104 3300 XL 8 mm Probe, M10 x 1 thread, with
(2)
armor
Part Number-AA-BB-CC-DD-EE
A: Unthreaded Length Option
Order in increments of 10 mm
Length configurations:
Maximum unthreaded length: 230 mm
Minimum unthreaded length: 0 mm
Example: 0 6 = 60 mm
B: Overall Case Length Option
(2)
Unthreaded length must be at least 20 mm
less than the case length.
13/41
Page 14
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Order in increments of 10 mm
Metric thread configurations:
Maximum case length: 250 mm
Minimum case length: 20 mm
Example: 0 6 = 60 mm
C: Total Length Option
050.5 meter (1.6 feet)
10
1.0 meter (3.3 feet)
151.5 meter (4.9 feet)
20
50
90
2.0 meters (6.6 feet)
5.0 meters (16.4 feet)
9.0 meters (29.5 feet)
5-meter probes are designed for use with the
5 meter Proximitor sensor only.
D: Connector and Cable-Type Option
01
Miniature coaxial ClickLoc connector with
connector protector, standard cable
02Miniature coaxial ClickLoc connector,
standard cable
11Miniature coaxial ClickLoc connector with
connector protector, FluidLoc cable
050.5 meter (1.6 feet)
10
1.0 meter (3.3 feet)
151.5 meter (4.9 feet)
20
50
90
2.0 meters (6.6 feet)
5.0 meters (16.4 feet)
9.0 meters (29.5 feet)
5-meter probes are designed for use with the
5 meter Proximitor sensor only.
The FluidLoc cable option –12 is not
necessary on the vast majority of 330105
and 330106 installations due to the presence
of the probe sleeve. Consider carefully the
application before ordering the FluidLoc cable
option for these probes.
E: Agency Approval Option
00Not required
12Miniature coaxial ClickLoc connector,
FluidLoc cable
E: Agency Approval Option
00
05
Not required
CSA, ATEX, IECEx Approvals
3300 XL 8 mm Reverse Mount Probes
330105-02-12-CC-DD-EE3/8-24 UNF threads
330106-05-30-CC-DD-EE M10 x 1 threads
Option Descriptions
C: Total Length Option
(2)
(2)
05CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes, Smooth
Case:
330140 3300 XL 8 mm Probe without armor
330141 3300 XL 8 mm Probe with armor
Part Number-AA-BB-CC-DD
A: Overall Case Length Option
Order in increments of 0.1 in.
Length configurations:
Maximum unthreaded length: 9.6 in.
Minimum unthreaded length: 0.8 in.
Example: 24 = 2.4 in.
(1)
(1)
14/41
Page 15
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
B: Total Length Option
050.5 meter (1.6 feet)
10
151.5 meter (4.9 feet)
20
50
90
C: Connector and Cable-Type Option
01
02Miniature coaxial ClickLoc connector,
11Miniature coaxial ClickLoc connector with
12Miniature coaxial ClickLoc connector,
D: Agency Approval Option
00
05
1.0 meter (3.3 feet)
2.0 meters (6.6 feet)
5.0 meters (16.4 feet)
9.0 meters (29.5 feet)
5-meter probes are designed for use with the
5 meter Proximitor sensor only.
Miniature coaxial ClickLoc connector with
connector protector, standard cable
standard cable
connector protector, FluidLoc cable
FluidLoc cable
Not required
CSA, ATEX, IECEx Approvals
Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
Example: 1 5 = 1.5 in.
B: Overall Case Length Option
Order in increments of 0.5 in.
Standard thread configurations:
Maximum case length: 9.6 in.
Minimum case length: 0.8 in.
Example: 2 5 = 2.5 in.
C: Total Length Option
050.5 meter (1.6 feet)
10
151.5 meter (4.9 feet)
20
50
90
D: Agency Approval Option
00
05
1.0 meter (3.3 feet)
2.0 meters (6.6 feet)
5.0 meters (16.4 feet)
9.0 meters (29.5 feet)
5-meter probes are designed for use with the
5 meter Proximitor sensor only.
Not required
CSA, ATEX, IECEx Approvals
3300 XL 8 mm Extended Temperature Range
(ETR) Proximity Probes:
330191 3300 XL 8 mm ETR Probe, 3/8-24 UNF
thread, without armor
330192 3300 XL 8 mm ETR Probe, 3/8-24 UNF
thread, with armor
Part Number-AA-BB-CC-DD
A: Unthreaded Length Option
Unthreaded length must be at least 0.8 in.
less than the case length.
Order in increments of 0.1 in.
3300 XL 8 mm Extended Temperature Range
(ETR) Proximity Probes, Metric:
330193 3300 XL 8 mm Probe, M10 x 1 thread,
without armor
330194 3300 XL 8 mm Probe, M10 x 1 thread, with
armor
Part Number-AA-BB-CC-DD
A: Unthreaded Length Option
Unthreaded length must be at least 20 mm
less than the case length.
Order in increments of 10 mm
15/41
Page 16
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
9.0 meters (29.5 feet)
Length configurations:
Maximum unthreaded length: 230 mm
Minimum unthreaded length: 0 mm
Example: 0 6 = 60 mm
90
5-meter probes are designed for use with the
5 meter Proximitor sensor only.
B: Overall Case Length Option
Order in increments of 10 mm
Metric thread configurations:
Maximum case length: 250 mm
Minimum case length: 20 mm
Example: 0 6 = 60 mm
C: Total Length Option
050.5 meter (1.6 feet)
10
151.5 meter (4.9 feet)
20
50
90
D: Agency Approval Option
1.0 meter (3.3 feet)
2.0 meters (6.6 feet)
5.0 meters (16.4 feet)
9.0 meters (29.5 feet)
5-meter probes are designed for use with the
5 meter Proximitor sensor only.
D: Agency Approval Option
Not required
00
CSA, ATEX, IECEx approvals
05
3300 XL 8 mm Extended Temperature Range
(ETR) Proximity Probes, Smooth Case:
330197 3300 XL 8 mm Probe without armor
330198 3300 XL 8 mm Probe with armor
Part Number-AA-BB-CC
A: Overall Case Length Option
Order in increments of 0.5 in.
Length configurations:
Maximum unthreaded length: 9.5 in.
Minimum unthreaded length: 1.0 in.
Example: 3 5 = 3.5 in.
B: Total Length Option
1
1
00
05
Not required
CSA, ATEX, IECEx Approvals
3300 XL 8 mm Extended Temperature Range
(ETR) Reverse Mount Probes
330195-02-12-CC-DD3/8-24 UNF threads
330196-05-30-CC-DD M10 x 1 threads
C: Total Length Option
050.5 meter (1.6 feet)
1.0 meter (3.3 feet)
10
151.5 meter (4.9 feet)
2.0 meters (6.6 feet)
20
5.0 meters (16.4 feet)
50
050.5 meter (1.6 feet)
10
151.5 meter (4.9 feet)
20
50
90
C: Agency Approval Option
00
05
1.0 meter (3.3 feet)
2.0 meters (6.6 feet)
5.0 meters (16.4 feet)
9.0 meters (29.5 feet)
5-meter probes are designed for use with the
5 meter Proximitor sensor only.
Not required
CSA, ATEX, IECEx Approvals
Aluminum probe clamp bracket1
137491-AA
16/41
Page 17
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
A: Mounting screw option
01
10-24 UNC-2A mounting screws
02M5 x 0.8-6g mounting screws
for 330140, 330141, 330197, and 330198.
2. For a shorter delivery time, order commonly
stocked probes. The following part numbers are
currently stocked probes:
330101-00-08-05-02-00, 330101-00-08-05-02-05,
The aluminum clamp bracket is an unthreaded
mounting bracket designed for use with the smooth
case probes (330140, 330141, 330197 and 330198).
After gapping the probe, tighten the clamp bracket by
tightening the screws. The mounting screws have predrilled holes for safety wire.
The aluminum probe threaded mounting bracket is the
standard mounting bracket for most 3300 and 3300 XL
probe installations. The -01 option includes two 10-24
UNC-2A mounting screws. The -04 option includes
two M5 x 0.8-6g mounting screws. The mounting
screws have pre-drilled holes for safety wire.
Phenolic threaded probe mounting bracket
27474-AA
A: Thread size
01
04M10 x 1
Bently Nevada recommends the phenolic threaded
mounting bracket if your application requires additional
electric isolation from the mounting location (as in some
generator and electrical motor bearing locations). The 01 option includes two 10-24 UNC-2A mounting
screws. The -04 option includes two M5 x 0.8-6g
mounting screws. The mounting screws have predrilled holes for safety wire.
3/8-24
Probe Ordering Information Notes:
1. Mounting clamps must be ordered separately
17/41
Page 18
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Ordering Information for Proximitor
Sensor
3300 XL Proximitor Sensor
330180-AA-BB
A: Total Length and Mounting Option
10
111.0 meter (3.3 feet) system length, DIN
121.0 meter (3.3 feet) system length, no
50
515.0 meters (16.4 feet) system length, DIN
52
90
91
1.0 meter (3.3 feet) system length, panel
mount
mount
mounting hardware
5.0 meters (16.4 feet) system length, panel
mount
mount
5.0 meters (16.4 feet) system length, no
mounting hardware
9.0 meters (29.5 feet) system length, panel
mount
9.0 meters (29.5 feet) system length, DIN
mount
and the probe length, when added together,
equal the Proximitor Sensor total length.
A: Cable Length Option
030
0353.5 meters (13.1 feet)
0404.0 meters (11.5 feet)
045
0606.0 meters (19.7 feet)
070
075
080
085
B: Connector Protector and Cable Option
00Standard cable
01Armored cable
02Standard cable with connector protector
03Armored cable with connector protector
10FluidLoc cable
3.0 meters (9.8 feet)
4.5 meters (14.8 feet)
7.0 meters (22.9 feet)
7.5 meters (24.6 feet)
8.0 meters (26.2 feet)
8.5 meters (27.9 feet)
92
B: Agency Approval Option
00
05
9.0 meters (29.5 feet) system length, no
mounting hardware
Not required
CSA, ATEX, IECEx Approvals
Ordering Information for Extension
Cables
3300 XL Standard Extension Cable
330130-AAA-BB-CC
Make sure that the extension cable length
11Armored FluidLoc cable
12FluidLoc cable with connector protector
13
C: Agency Approval Option
00
05
Armored FluidLoc cable with connector
protector
Not required
CSA, ATEX, IECEx Approvals
18/41
Page 19
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
3300 XL Extended Temperature Range (ETR)
Extension Cable
330190-AAA-BB-CC
Make sure that the extension cable length
and the probe length, when added together,
equal the Proximitor Sensor total length.
A: Cable Length Option
3.0 meters (9.8 feet)
030
0353.5 meters (13.1 feet)
0404.0 meters (11.5 feet)
4.5 meters (14.8 feet)
045
7.0 meters (22.9 feet)
070
7.5 meters (24.6 feet)
075
8.0 meters (26.2 feet)
080
8.5 meters (27.9 feet)
085
B: Cable Option
00Standard cable
01Armored cable
C: Agency Approval Option
Not required
00
Housing. 12”x8”x6”. Can hold up to 4
3300XL Proximitor Sensors in both DINmount and panel-mount configurations.
(Available with ATEX Zone 0 and Zone 1
certifications.)
3301813300 XL Multi-Purpose Stainless Steel
Housing. 13”x9.5”x7”. Can hold up to 8
Proximitor sensors in a DIN-mount
configuration or 6 Proximitor Sensors in a
panel-mount configuration. Primarily
used by customers requiring hazardous
area approvals fro their installations.
Available with ATEX Zone 0 and Zone 1
and North American Division 1 and
Division 2 certifications.
02120015
Bulk field wire. 1.0 mm2 (18 AWG), 3
conductor, twisted, shielded cable with
drain wire. Specify length in feet.
138492-01
138493-01
148722-01
Replacement panel-mount mounting pad.
Replacement DIN-mount mounting pad.
3300 XL test plug. The 3300 XL Test Plug
contains 3 small test pins attached to 3
color-coded 1-meter wires, each
terminated in a banana plug. The 3-pin
adapter plugs into the test pin holes on
3300 XL-style Proximitor sensors. You
can use this test plug to check the
performance of the Proximitor sensor
from the test pin holes in the terminal strip
without removing the field wiring.
CSA, ATEX, IECEx Approvals
05
Accessories
1410783300 XL 8 mm and 3300 5 mm Proximity
Transducer System Manual.
175751
1764673300 XL Multi-Purpose Stainless Steel
3300 XL Multi-Purpose Stainless Steel
Housing. 12”x12”x6”. Can hold up to 8
Proximitor Sensors in a DIN-mount
configuration or 6 Proximitor Sensors in a
panel-mount configuration. (Available
with ATEX Zone 0 and Zone 1
certifications.)
04310310 3300 XL Proximitor Sensor panel-mount
screw. One 6-32 UNC thread forming
mounting screw. Four screws are
required for each Proximitor sensor.
(Screws supplied standard with
Proximitor housings [3300 XL panelmount option]).
03200006 Silicone self-fusing tape. A 9.1-meter
(10-yard) roll of silicone tape to protect
connectors. This tape is easy to install
and provides excellent electrical isolation
and protection from the environment. We
do not recommend using this tape inside
the casing of the machine.
40113-02
19/41
Connector Protector Kit. Connector
Page 20
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Protector Kit for 3300 XL 8 mm probes
and extension cables, including
connector protectors and installation
tools.
136536-01
Connector protector adapter. This allows
you to use connector protector
installation tools manufactured prior to
1998 with 75Ω ClickLoc connectors.
40180-02
Connector protectors. Package contains
10 pairs of connector protectors for 3300
XL 8 mm probes and extension cables.
03839410 75Ω triaxial male connector protector.
Male connector protectors install onto the
extension cable and attach to the female
connector protector on the probe,
providing environmental protection of
connectors.
03839420 75Ω triaxial female connector protector.
Female connector protectors install onto
the probe lead and attach to the male
connector protector on the extension
cable, providing environmental protection
of connectors. You can also place the
connector protector onto the extension
cable to slide over the connection to the
Proximitor sensor to protect that
connection from the environment.
two color-coded sleeves, two pieces of
high temperature slit FEP tubing, and one
strip of silicon tape.
163356Connector Crimp Tool Kit. Includes 1 set
of multiconnector inserts and connector
installation instructions. Compatible only
with 330153 connector kits or with probes
shipped in 2003 or later with ClickLoc
connectors uninstalled. Supplied with
carrying case.
04301007
04301008
330153-01
330153-09
3/8-24 probe lock nut with safety wire
holes. Single probe lock nut with 2 holes
drilled through the nut in order to secure
the lock nut in place with safety wire.
M10 x 1 probe lock nut with safety wire
holes. Single probe lock nut with 2 holes
drilled through the nut in order to secure
the lock nut in place with safety wire.
3300 XL connector kit. Used on 3300 XL
8 mm probes and extension cables.
Contains 1 pair each of male and female
ClickLoc connectors, 2 color-coded
sleeves, 2 pieces of slit FEP tubing, and
1 strip of silicone tape.
3300 XL ETR Connector Kit. Used on
ETR 3300 XL 8mm probes and 3300 ETR
XL extension cables. Contains one pair
of male and female ClickLoc connectors,
20/41
Page 21
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Graphs and Figures
Figure 1: Typical 3300 XL 8mm 5m or 1m System over API 670 Range
21/41
Page 22
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 2: Typical 3300 XL 8mm 9m System over API 670 Testing Range
22/41
Page 23
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 3: Typical 3300 XL 8mm Probe over API 670 Operating Range
23/41
Page 24
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 4: Typical 3300 XL 8 mm 5m Proximitor Sensor with 4m Extension Cable at Tc (Probe is at 25 °C)
24/41
Page 25
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 5: Typical 3300 XL 8 mm 5m Proximitor Sensor with 4m Extension Cable at Th (Probe is at 25°C)
25/41
Page 26
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 6: Typical 3300 XL 8mm 9 m Proximitor Sensor with 8m of Extension Cable at Tc (Probe is at 25 °C)
26/41
Page 27
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 7: Typical 3300 XL 8mm 9m Proximitor Sensor with 8m Extension Cable at Th (Probe is at 25 °C)
27/41
Page 28
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 8: Typical 3300 XL Extended Temperature Range Probe and 4m Extended Temperature Range
Extension Cable at Th (Proximitor Sensor and Probe Tip with 1-foot Cable are at +25 °C)
28/41
Page 29
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 9: Typical 3300 XL Extended Temperature Range Probe and 8m Extended Temperature Range
Extension Cable at Th (Proximitor Sensor and Probe Tip with 1-foot Cable are at +25 °C)
29/41
Page 30
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 10: Frequency Response, Typical 3300 XL 8mm 5m or 1m System with Varying Lengths of Field Wiring
Attached, No Barriers
30/41
Page 31
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 11: Phase Response, Typical 3300 XL 8mm 5m or 1m System with Varying Lengths of Field Wiring
Attached, No Barriers
31/41
Page 32
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 12: Frequency Response, Typical 3300 XL 8mm 9m System with Varying Lengths of Field Wiring
Attached, No Barriers
32/41
Page 33
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 13: Phase Response, Typical 3300 XL 8mm 9m System with Varying Lengths of Field Wiring Attached,
No Barriers
Note: All dimensions shown in millimeters (inches) except as noted.
33/41
Page 34
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
1. Probe tip, 8.0 mm (0.31 in) diameter
2. 9/16 in for 3/8-24 threads, M17 for M10 threads (see Note 2)
3. Case thread
4. 5/16 in wrench flats for 3/8-24 threads; 8mm wrench flats for M10 threads.
5. 75Ω cable, 3.68 mm (0.145 in) maximum outside diameter, 3.94 mm (0.155 in) maximum outside diameter for
FluidLoc cable, 7.67 mm (0.302 in) outside diameter of armor, 9.5 mm (0.38 in) maximum diameter of armor
ferrule
6. Miniature male coaxial connector, 7.24 mm (0.285 in) maximum outside diameter “D”
7. Unthreaded length “A”
8. Case length “B”
9. 6.0 mm (0.235 in) maximum
10. Total length “C”, +30%, -0%
3
Figure 14: 3300 XL 8mm Proximity Probes, Standard Mount
330101 and 330191, 3/8-24 UNF-2A, without armor
330102 and 330192, 3/8-24 UNF-2A, with armor
330103 and 330193, M10X1 thread, without armor
330104 and 330194, M10X1 thread, with armor
7
6
7
6
34/41
Page 35
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
1. Probe tip, 8.0 mm (0.31 in) diameter
2. 7/16 in or M10 hexagonal
3. Case thread
4. 75Ω cable, 3.68 mm (0.145 in) outside diameter
5. Miniature male coaxial connector, 7.24 mm (0.285 in) maximum outside diameter “D”
6. Unthreaded length “A”, 5.0 mm (0.20 in)
7. Case length “B”, 30 mm (1.2 in)
8. 6.0 mm (0.235 in) maximum
9. Total length “C”, +30%, -0%
3
Figure 15: 3300 XL 8mm Proximity Probes, Reverse Mount
330105 and 330195, 3/8-24 UNF-2A threads
330106 and 330196, M10X1 threads
4, 7
35/41
Page 36
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
1. Probe tip, 8 mm (0.31 in) diameter
2. 9.66 mm (0.38 in) maximum diameter
3. 5/16 in wrench flats, 4 each
4. 75Ω cable, 3.68 mm (0.145 in) maximum diameter, 3.94 mm (0.155 in) maximum diameter for FluidLoc cable,
7.67 mm (0.302 in) outside diameter with armor, 10.2 mm (0.4 in) maximum diameter for armor ferrule
5. Miniature male coaxial connector, 7.24 mm (0.285 in) maximum outside diameter “D”
6. Case length “A”,
7. 349.3 (13.75) max. distance
8. 6.0 mm (0.235 in) maximum
9. Total length “C”, +30%, -0%
3
Figure 16: 3300 XL 8mm Proximity Probes, Smooth Case
330140 and 330197, without armor
330141 and 330198, with armor
7
6
36/41
Page 37
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
1. 7.24 mm (0.285 in) maximum diameter
2. Miniature male coaxial connector
3. FEP or PFA coated armor, armor length 300 mm (11.8 in) less than cable length (see Note 6)
4. 75Ω cable, 3.7 mm (0.15 in) maximum outside diameter, 3.94 mm (0.155 in) maximum diameter for FluidLoc
cable, 7.67 mm (0.302 in) maximum outside diameter of armor, 10.2 mm (0.40 in) maximum diameter of armor
ferrule
5. 7.24 mm (0.285 in) maximum diameter
6. Stainless steel ferrules, 10.2 mm (0.40 in) max diameter
7. FEP or PFA insulated triaxial cable
8. Miniature female coaxial connector
9. Cable length, +20%, -0%
Figure 17: Extension Cable without Connector Protectors
330130, 3300 XL Extension Cable (FEP Armor and Insulation)
330190, 3300 XL ETR Extension Cable (PFA Armor and Insulation)
37/41
Page 38
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
1. 12.4 mm (0.49 in) maximum diameter
2. 51.1 mm (2.01 in) maximum
3. 36.3 mm (1.43 in) maximum.
4. 12.4 mm (0.49 in) maximum diameter
5. Connector protector (fluorosilicone material) only installed on female end when optioned. Both ends available as
accessories.
Figure 18: Extension Cable with Connector Protectors
1. Mounting option “A”, Options –50 or -90
38/41
Page 39
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Figure 19: Panel Mount 3300 XL Proximitor Sensor
1. Mounting option “A”, Options –51 or –91
2. 35mm DIN rail (not included)
3. 89.4 mm (3.52 in). Additional 3.05 mm (0.120 in) clearance required to remove DIN rail.
Figure 20: DIN Mount 3300 XL Proximitor Sensor
39/41
Page 40
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
1. Mounting option “A”, Options –50 or -90
Figure 21: Physical Mounting Characteristics Showing Interchangeability of 3300 and 3300 XL Proximitor
Sensors when 4-hole Mounting Option Is Used
8
Figure Notes:
1. All dimensions on figures are in millimeters (inches) unless otherwise noted.
2. Standard mount 8 mm probes supplied with M17 or 9/16 inch lock nut.
3. Probes ordered with 5 or 9 meter integral cables have a length tolerance of +20%, -0%.
4. Reverse mount probes not available with armor or connector protector options.
5. Letters inside quotation marks on figures refer to probe ordering options.
6. Stainless steel armor is supplied with FEP outer jacket for standard probes, PFA outer jacket for ETR probes.
7. FEP jacket is standard non-armored portion of the cable for standard probes, PFA jacket on non-armored portion
for ETR probes.
8. Use M3.5 or #6 screws for panel-mount Proximitor Sensors (screws provided when purchasing Bently Nevada
housings).
40/41
Page 41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Copyright 2020 Baker Hughes Company. All rights reserved.
Bently Nevada, Orbit Logo, Keyphasor and Proximitor are registered trademarks of Bently Nevada, a Baker Hughes
Business, in the United States and other countries. The Baker Hughes logo is a trademark of Baker Hughes Company. All
other product and company names are trademarks of their respective holders. Use of the trademarks does not imply any
affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not make
any representation as to the accuracy or completeness of the information and makes no warranties of any kind, specific,
implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness for a particular purpose
or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect, consequential or special damages, claims
for lost profits, or third party claims arising from the use of the information, whether a claim is asserted in contract, tort, or
otherwise. Baker Hughes reserves the right to make changes in specifications and features shown herein, or discontinue the
product described at any time without notice or obligation. Contact your Baker Hughes representative for the most current
information.
The information contained in this document is the property of Baker Hughes and its affiliates; and is subject to change without
prior notice. It is being supplied as a service to our customers and may not be altered or its content repackaged without the
express written consent of Baker Hughes. This product or associated products may be covered by one or more patents. See
Bently.com/legal.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 1.775.782.3611 or 1.800.227.5514 (US only)
Bently.com
41/41
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.