The 3300 XL 8 mm Proximity Transducer System consists of:
oOne 3300 XL 8 mm probe,
oOne 3300 XL extension cable1, and
oOne 3300 XL Proximitor Sensor2.
The system provides an output voltage that is directly proportional to the
distance between the probe tip and the observed conductive surface
and can measure both static (position) and dynamic (vibration) values.
The system’s primary applications are vibration and position
measurements on fluid-film bearing machines, as well as Keyphasor
reference and speed measurements3.
The 3300 XL 8 mm system delivers the most advanced performance in
our eddy current proximity transducer systems. The standard 3300 XL
8 mm 5-meter system also fully complies with the American Petroleum
Institute’s (API) 670 Standard (4th Edition) for mechanical configuration,
linear range, accuracy, and temperature stability. All 3300 XL 8 mm
proximity transducer systems provide this level of performance and
support complete interchangeability of probes, extension cables, and
Proximitor sensors, eliminating the need to match or bench calibrate
individual components.
141194 Rev. AH
Each 3300 XL 8 mm Transducer System component is backward
compatible and interchangeable4 with other non-XL 3300 series 5 mm
and 8 mm transducer system components5. This compatibility includes
the 3300 5 mm probe, for applications in which an 8 mm probe is too
large for the available mounting space
6,7
.
Proximitor Sensor
The 3300 XL Proximitor Sensor incorporates numerous improvements
over previous designs. Its physical packaging allows you to use it in
high-density DIN-rail installations. You can also mount the sensor in a
traditional panel mount configuration, where it shares an identical 4-hole
mounting “footprint” with older Proximitor Sensor designs. The
mounting base for either option provides electrical isolation and
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
eliminates the need for separate isolator plates. The
3300 XL Proximitor Sensor is highly immune to radio
frequency interference, allowing you to install it in
fiberglass housings without adverse effects from
nearby radio frequency signals. The 3300 XL
Proximitor Sensor’s improved RFI/EMI immunity
satisfies European CE mark approvals without
requiring special shielded conduit or metallic housings,
resulting in lower installation costs and complexity.
The 3300 XL’s SpringLoc terminal strips require no
special installation tools and facilitate faster, more
robust field wiring connections by eliminating screwtype clamping mechanisms that can loosen.
standard 177 ˚C (350 ˚F) temperature specification. The
ETR probe has an extended temperature rating for up to
218 ˚C (425 ˚F). The ETR extension cable rating is up
to 260 ˚C (500 ˚F). Both the ETR probe and cable are
compatible with standard temperature probes and
cables, for example, you can utilize an ETR probe with
the 330130 extension cable. The ETR system uses the
standard 3300 XL Proximitor Sensor. Note that when
you use any ETR component as part of your system,
the ETR component limits the system accuracy to the
accuracy of the ETR system.
Description Notes:
Proximity Probe and Extension Cable
The 3300 XL probe and extension cable also reflect
improvements over previous designs. A patented
TipLoc molding method provides a more robust bond
between the probe tip and the probe body. The probe’s
cable incorporates a patented CableLoc design that
provides 330 N (75 lbf) pull strength to more securely
attach the probe cable and probe tip.
You can also order 3300 XL 8 mm probes and extension
cables with an optional FluidLoc cable option. This
option prevents oil and other liquids from leaking out of
the machine through the cable’s interior.
Connectors
The 3300 XL probe, extension cable, and Proximitor
sensor have corrosion-resistant, gold-plated ClickLoc
connectors. These connectors require only finger-tight
torque (the connectors will "click" when tight), and the
specially-engineered locking mechanism prevents the
connectors from loosening. These connectors require
no special tools for installation or removal.
You can order the 3300 XL 8 mm probes and extension
cables with connector protectors already installed. We
can also supply connector protectors separately for
field installations (such as when an application must
run the cable through restrictive conduit). We
recommend connector protectors for all installations to
provide increased environmental protection8.
Extended Temperature Range
Applications
An extended temperature range (ETR) probe and ETR
extension cable are available for applications in which
either the probe lead or extension cable may exceed the
1. One-meter systems do not use an extension cable.
2. Proximitor sensors are supplied by default from the
factory calibrated to AISI 4140 steel. Calibration to
other target materials is available upon request.
3. Consult Bently Nevada Applications Note,
Considerations when using Eddy Current Proximity
Probes for Overspeed Protection Applications, when
considering this transducer system for tachometer or
overspeed measurements.
4. 3300 XL 8 mm components are both electrically and
physically interchangeable with non-XL 3300 5 mm and
8 mm components. Although the packaging of the 3300
XL Proximitor Sensor differs from its predecessor, its
design fits in the same 4-hole mounting pattern when
used with the 4-hole mounting base, and will fit within
the same mounting space specifications (when
minimum permissible cable bend radius is observed).
5. Mixing XL and non-XL 3300-series 5 mm and 8 mm
system components limits system performance to the
specifications for the non-XL 3300 5 mm and 8 mm
Transducer System.
6. The 3300-series 5 mm probe (refer to Document
141605) uses smaller physical packaging, but does not
reduce the side view clearances or tip-to-tip spacing
requirements as compared to an 8mm probe. It is used
when physical (not electrical) constraints preclude the
use of an 8mm probe. When your application requires
narrow side view probes, use the 3300 NSv Proximity
Transducer System (refer to Document 147385).
7. 8 mm probes provide a thicker encapsulation of the
probe coil in the molded PPS plastic probe tip. This
results in a more rugged probe. The larger diameter of
the probe body also provides a stronger, more robust
case. We recommend that you use 8 mm probes when
2/41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
possible to provide optimal robustness against physical
abuse.
8. Each 3300 XL extension cable includes silicone tape
that you can use instead of connector protectors. We
do not recommend silicone tape for applications that
will expose the probe-to-extension cable connection to
turbine oil.
3/41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Specifications
Unless otherwise noted, the following specifications
are for a 3300 XL 8 mm Proximitor Sensor, extension
cable and 8 mm probe between +18 ˚C and +27 ˚C (+64
˚F to +80 ˚F), with a -24 Vdc power supply, a 10 kΩ
load, an AISI 4140 steel target, and a probe gapped at
1.27 mm (50 mils). Performance characteristics apply
to systems that consist solely of 3300 XL 8 mm
components. The system accuracy and
interchangeability specifications do not apply to
transducer systems that are calibrated to any target
other than our AISI 4140 steel target.
Electrical
Proximitor
Sensor Input
PowerRequires -17.5 Vdc to -26 Vdc
Supply
Sensitivity
Output
Resistance
Accepts one non-contacting 3300series 5mm, 3300 XL 8mm
Proximity Probe and Extension
Cable.
without barriers at 12 mA maximum
consumption, -23 Vdc to -26 Vdc
with barriers. Operation at a more
positive voltage than -23.5 Vdc can
result in reduced linear range.
Less than 2 mV change in output
voltage per volt change in input
voltage.
50 Ω
2.0
3.0
7.88±0.50
8.17±0.50
5.08.73±0.50
9.09.87±0.50
Nominal Extension Cable DC Resistance
Resistance
(R
) from Center Conductor to
CORE
Center Conductor
Length of
RCORE (Ω)
Extension
Cable
(m)
3.00.66±0.10
3.50.77±0.12
4.00.88±0.13
4.50.99±0.15
6.01.32±0.21
7.01.54±0.23
7.51.65±0..25
8.01.76±0.26
8.51.87±0.28
Nominal Probe DC Resistance
Resistance
(R
PROBE
) from Center Conductor to
Outer Conductor)
Probe
R
PROBE
Length
(m)
0.57.45±0.50
1.0
1.5
7.59±0.50
7.73±0.50
(Ω)
Resistance (R
Outer Conductor
4/41
JACKET
) from Outer Conductor to
Length of
R
JACKET
Extension
Cable
(m)
3.00.20±0.04
3.50.23±0.05
4.00.26±0.05
4.50.30±0.06
6.00.39±0.08
(Ω)
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
7.00.46±0.09
7.5
0.49±0.10
8.00.53±0.11
8.50.56±0.11
Extension
69.9 pF/m (21.3 pF/ft) typical
Cable
Capacitance
Field Wiring0.2 to 1.5 mm2 (16 to 24 AWG) .
Recommend using 3 conductor
shielded triad cable and tinned field
wiring. Maximum length of 305
meters (1,000 feet) between the
3300 XL Proximitor Sensor and the
monitor. See the frequency
response graphs, Figures 10 and
12, for signal rolloff at high
frequencies when using longer field
wiring lengths.
Linear Range2 mm (80 mils). Linear range begins
at approximately 0.25 mm (10 mils)
from target and is from 0.25 to 2.3
mm (10 to 90 mils) (approximately –
1 to –17 Vdc).
Extended
Temperature
Range (ETR)
for 5 and 9
Meter Systems
7.87 V/mm (200 mV/mil) ± 6.5%
including interchangeability error
when measured in increments of
0.25 mm (10 mils) over the 80 mil
linear range from 0 °C to +45 °C
(+32 °F to +113 °F).
Deviation from best fit straight line (DSL)
Standard 5 or 1
meter System
Less than ±0.025 mm (±1 mil) with
components at 0 °C to +45 °C (+32
°F to +113 °F).
Standard 9
meter System
Less than ±0.038 mm (±1.5 mil)
with components at 0 °C to +45 °C
(+32 °F to +113 °F).
Extended
Temperature
Range 5 and 9
Less than ±0.038 mm (±1.5 mil)
with components at 0 °C to +45 °C
(+32 °F to +113 °F).
meter Systems
Performance over Extended Temperatures
Standard 5 or 1
meter System
Over a probe temperature range of –
35 °C to +120 °C (-31 °F to +248 °F)
with the Proximitor sensor and
extension cable between 0 °C to
+45°C (+32 °F to +113 °F), the ISF
remains within ±10% of 7.87 V/mm
(200 mV/mil) and the DSL remains
within ±0.076 mm (±3 mils).
Recommended
Gap Setting for
Radial
Vibration
Incremental Scale Factor (ISF)
Standard 5 or 1
meter System
Standard 9
meter System
-9 Vdc [approximately 1.27 mm (50
mils)]
7.87 V/mm (200 mV/mil) ± 5%
including interchangeability error
when measured in increments of
0.25 mm (10 mils) over the 80 mil
linear range from 0 °C to +45 °C
(+32 °F to +113 °F).
7.87 V/mm (200 mV/mil) ± 6.5%
including interchangeability error
when measured in increments of
0.25 mm (10 mils) over the 80 mil
linear range from 0 °C to +45 °C
(+32 °F to +113 °F).
Standard 9
meter System
Over a Proximitor sensor and
extension cable temperature range
of –35 °C to +65 °C (-31 °F to +149
°F) with the probe between 0 °C to
+45 °C (+32 °F to +113 °F), the ISF
remains within ±10% of 7.87 V/mm
(200 mV/mil) and the DSL remains
within ±0.076 mm (±3 mils).
Over a probe temperature range of
–35 °C to +120 °C (-31 °F to +248
°F) with the Proximitor sensor and
extension cable between 0 °C to
+45°C (+32 °F to +113 °F), the ISF
remains within ±18% of 7.87 V/mm
(200 mV/mil) and the DSL remains
within ±0.152 mm (±6 mils).
Over a Proximitor sensor and
5/41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
extension cable temperature range
of –35 °C to +65 °C (-31 °F to +149
°F) with the probe between 0 °C to
+45 °C (+32 °F to +113 °F), the ISF
remains within ±18% of 7.87 V/mm
(200 mV/mil) and the DSL remains
within ±0.152 mm (±6 mils).
Extended
Temperature
Range 5 and 9
meter Systems
Frequency
Response
Minimum
Target Size
Minimum50.8 mm (2 in)
Recommended
Minimum
When gapped at the center of the linear
range, the interaction between two separate
transducer systems (cross-talk) will be less
than 50 mV on shaft diameters of at least 50
mm (2 in) or greater. You should take care to
maintain minimum separation of transducer
tips, generally at least 40 mm (1.6 in) for axial
position measurements or 38 mm (1.5 in) for
radial vibration measurements to limit crosstalk to 50 mV or less. Radial vibration or
position measurements on shaft diameters
smaller than 76.2 mm (3 in) will generally
change the scale factor.
Effects of 60 Hz Magnetic Fields Up to 300 Gauss
Output Voltage in Mil pp/Gauss
Gap
5 or 1-meter
Over a probe and extension cable
temperature range of –35 °C to +260
°C (-31 °F to +500 °F) with the
Proximitor sensor between 0 °C to
+45 °C (+32 °F to +113 °F), the ISF
remains within ±18% of 7.87 V/mm
(200 mV/mil) and the DSL remains
within ±0.152 mm (±6 mils).
(0 to 10 kHz), +0, -3 dB, with up to
305 meters (1000 feet) of field
wiring.
15.2 mm (0.6 in) diameter (flat
target)
Shaft Diameter
76.2 mm (3 in)
9 meter ProbeExt.
Proximitor
Sensor
100.0119
500.0131
900.0133
Proximitor
Sensor
0.02470.0004 0.0004
0.03230.0014 0.0014
0.03480.0045 0.0045
Mechanical
Probe Tip MaterialPolyphenylene sulfide (PPS).
Probe Case
Material
Probe Cable Specifications
Standard cable75Ω triaxial, fluoroethylene
Extended
Temperature
Range cable
Armor (optional on
both)
Tensile Strength
(Maximum Rated)
Connector
Material
Probe Case Torque
Probe TypeMaximum
Standard forward
mounted probes
Standard forwardmount probes first three threads
Reverse-mount
probes
AISI 303 or 304 stainless steel
(SST).
propylene (FEP) insulated probe
cable in the following total probe
lengths: 0.5, 1, 1.5, 2, 3, 5, or 9
meters.
75Ω triaxial, perfluoroalkoxy
(PFA) insulated probe cable in
the following total probe lengths:
0.5, 1, 1.5, 2, 5, or 9 meters.
Flexible AISI 302 or 304 SST
with FEP outer jacket.
330 N (75 lbf) probe case to
probe lead.
270 N (60 lbf) at probe lead to
extension cable connectors.
Gold-plated brass or gold-plated
beryllium copper.
Recommended
Rated
33.9 N•m
(300 in•lbf)
22.6 N•m
(200 in•lbf)
22.6 N•m
(200 in•lbf)
11.2 N•m (100
in•lbf)
7.5 N•m (66
in•lbf)
7.5 N•m (66
in•lbf)
Cable
6/41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Extension Cable Material
Standard cable75 Q triaxial, fluoroethylene
propylene (FEP) insulated
Extended
Temperature
Range cable
Minimum Cable
Bend Radius
3300 XL 8 mm components are both
electrically and physically interchangeable
with non-XL 3300 5 mm and 8 mm
components when minimum permissible
cable bend radius is observed.
Connector
Material
Maximum
Connector Torque
Connector-to-Connector Recommended Torque
Connector TypeTightening Instructions
75Ω triaxial, perfluoroalkoxy
(PFA) insulated.
25.4 mm (1.0 in)
Gold-plated brass or gold-plated
beryllium copper.
0.565 N•m (5 in•lbf)
Probe 323 g/m (11.4
oz.)
Extension
Cable
Armored
Extension
Cable
Proximitor
Sensor
34 g/m (0.4
oz/ft)
103 g/m (1.5
oz/ft)
246 g (8.67 oz)
Environmental Limits
Probe Temperature Range
Operating and Storage Temperature
Standard Probe
-52 °C to +177 °C (-62 °F to
+350 °F)
Extended
Temperature Range
Probe
-52°C to +218°C (-62°F to
+425°F) for the probe tip; -51°C
to +260°C (-60°F to +500°F) for
the probe cable and connector.
Two 3300 XL gold
"click" type
connectors
One non-XL
stainless steel
connector and one
3300 XL connector
Proximitor Sensor
Material
Connector
Material
System Length5 or 9 meters (including
Total System
Weight (TypicaI)
Finger tight
Finger tight plus 1/8 turn using
pliers
A308 aluminum
Gold-plated brass or goldplated beryllium copper.
extension cable) or 1 meter
(probe only).
0.7 kg (1.5 lb m)
Exposing the probe to temperatures below –
34 ˚C (-30 ˚F) may cause premature failure of
the pressure seal.
Probe Pressure
3300 XL 8 mm probes are designed to seal
differential pressure between the probe tip and case.
The probe sealing material consists of a Viton® O
ring. Probes are not pressure tested prior to
shipment. Contact our custom design department if
you require a test of the pressure seal for your
application.
It is the responsibility of the customer or user
to ensure that all liquids and gases are
contained and safely controlled should
leakage occur from a proximity probe. In
addition, solutions with high or low pH values
may erode the tip assembly of the probe
causing media leakage into surrounding
areas. Bently Nevada, LLC will not be held
7/41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
responsible for any damages resulting from
leaking 3300 XL 8 mm proximity probes. In
addition, 3300 XL 8 mm proximity probes will
not be replaced under the service plan due to
probe leakage.
Extension Cable Temperature Range
Operating and Storage Temperature
Standard Cable-52°C to +177°C
(-62°F to +350 °F)
Extended
Temperature Range
-52°C to +260 °C (-62 °F to
+500 °F)
Cable
Proximitor Sensor Temperature Range
Operating
Temperature
Storage
Temperature
-52°C to +100°C (-62°F to
+212°F)
52 °C to +105 °C (-62 °F to
+221 °F)
Probe Relative Humidity
Less than a 3% change in Average Scale Factor
(ASF) when tested in 93% humidity in accordance
with IEC standard 68 2 3 for up to 56 days.
8/41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Compliance and Certifications
FCC
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions:
l This device may not cause harmful
interference.
l This device must accept any interference
received, including interference that may
cause undesired operation.
EMC
EN 61000-6-2
EN 61000-6-4
EMC Directive 2014/30/EU
RoHS
RoHS Directive 2011/65/EU
Maritime
ABS 2009 Steel Vessels Rules
1-1-4/7.7,4-8-3/1.11.1,4-9-7/13
9/41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
with galvanic
Hazardous Area Approvals
For the detailed listing of country and product
specific approvals, refer to the
Quick Reference Guide
from Bently.com.
CSA/NRTL/C
(108M1756) available
Approvals
isolators.
nA, ec
When installed
without
barriers per
drawing
140979.
Class I, Zone 2: AEx/Ex nA IIC
T5…T1 Gc;
Class 1, Division 2, Groups A, B, C,
D;
Class 1, Zone 2: AEx/Ex ec llC
T5…T1 Gc; Class I, Division 2,
Groups A, B, C, and D;
3300 XL Proximitor Sensor
ia
When installed
with
intrinsically
safe zener
barriers per
drawing
141092 or
when installed
with galvanic
isolators.
nA, ec
When installed
without
barriers per
drawing
140979.
Class I, Zone 0: AEx/Ex ia IIC
T4/T5 Ga;
Class I, Groups A, B, C, and D,
Class II, Groups E, F and G,
Class III;
T5 @ Ta= -55°˚C to + 40°˚C.
T4 @ Ta= -55°˚C to + 80°C.
Class I, Zone 2: AEx/Ex nA IIC
T4/T5 Gc;
Class I, Division 2, Groups A, B, C,
and D;
Class I, Zone 2: AEx/Ex ec llC
T4/T5 Gc;
Class I, Division 2, Groups A, B, C,
and D;
(see Temperature Schedule table to
follow)
3300 XL Probe
ia
When installed
with
intrinsically
safe zener
barriers per
drawing
141092 or
when installed
T5 @ Ta= -55°C to + 40°C
T4 @ Ta= -55°C to + 80°C
Class I, Zone 0: AEx/Ex ia IIC
T5...T1 Ga;
Class 1, Groups A, B. C, and D,
Class II, Groups E, F, and G,
Class III;
(see Temperature Schedule table to
follow)
10/41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
ATEX/IECEx
3300 XL Proximitor Sensor
ia
nA,ec
3300 XL Probe
II 1 G
Ex ia IIC T4/T5 Ga
Ex ia IIIC T90C/T105C Dc
For EPL Dc:
T105C @ Ta = -55°C to 100°C
T90C @ Ta = -55°C to +85°C
Ui= -28V Uo= -28V
Ii= 140mAIo= 140mA
Pi= 0.91WPo= 0.742W
Ci- 47nFCo= 1.5nF
Li= 1460µHLo= 610µH
II 3 G
Ex nA IIC T4/T5 Gc
Ex ec llC T4/T5 Gc
Ui= -28V li= 140 mA
T5 @ Ta= -55˚ C to + 40˚C
T4 @ Ta= -55 ˚C to + 80˚C
nA,ec
II 3 G
Ex nA IIC T5…T1 Gc,
Ex ec llC T5…T1 Gc,
(see Temperature Schedule
table to follow)
Ui= -28V li= 140 mA
Temperature Schedule
Temperature
Classification
For EPL Ga and Gc
T1-55°C to +232°C
T2-55°C to +177°C
T3-55°C to +120°C
T4-55°C to +80°C
T5-55°C to +40°C
For EPL Dc
T280°C @ Ta-55°C to +232°C
T225°C @ Ta-55°C to +177°C
T170°C @ Ta-55C to +120°C
T130°C @ Ta-55°C to +80°C
Ambient Temperat ure (Probe
Only)
Probe entity parameters are met when used
with BN extension cables and connected to BN
Prox.
ia
II 1 G
Ex ia IIC T5…T1 Ga,
(see Temperature Schedule
table to follow)
Ex ia IIIC T90°C ... T280°C Dc
For EPL Dc:
Ui= -28V Ci = 1.5 nF
Ii = 140 mALi =610 μH
Pi = 0.91 W
T105°C @ Ta-55°C to +100°C
T90°C @ Ta-55°C to +40°C
11/41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Hazardous Area Conditions of
Safe Use
CSA/NRTL/C:
ia
Install per Bently Nevada drawing 141092.
nA, ec
Install per Bently Nevada drawing 140979.
ATEX/IECEx:
ia
Install per Bently Nevada drawing 141092.
nA, ec
The Prox must be installed so as to provide the
terminals with a degree of protection of at least IP54.
12/41
3300 XL 8mm Proximity Transducer System
Datasheet141194 Rev. AH
Ordering Information
For the detailed listing of country and product
specific approvals, refer to the
Quick Reference Guide
from Bently.com.
(108M1756) available
Ordering Information for Probes
3300 XL 8 mm Proximity Probes:
330101 3300 XL 8 mm Probe, 3/8-24 UNF thread,
without armor
330102 3300 XL 8 mm Probe, 3/8-24 UNF thread,
with armor
Part Number-AA-BB-CC-DD-EE
A: Unthreaded Length Option
Order in increments of 0.1 in.
Length configurations:
Maximum unthreaded length: 8.8 in.
Minimum unthreaded length: 0.0 in.
Example: 0 4 = 0.4 in.
(2)
(2)
Unthreaded length must be at least 0.8 in.
less than the case length.
Approvals
90
D: Connector and Cable-Type Option
01
02Miniature coaxial ClickLoc connector,
11Miniature coaxial ClickLoc connector with
12Miniature coaxial ClickLoc connector,
E: Agency Approval Option
00
05
9.0 meters (29.5 feet)
3-meter length option is only available on
330101 probes, and is designed for use with
the 9 meter Proximitor sensor only.
5-meter probes are designed for use with the
5 meter Proximitor sensor only.
Miniature coaxial ClickLoc connector with
connector protector, standard cable
standard cable
connector protector, FluidLoc cable
FluidLoc cable
Not required
CSA, ATEX, IECEx Approvals
3300 XL 8 mm Proximity Probes, Metric:
B: Overall Case Length Option
Order in increments of 0.1 in.
Standard thread configurations:
Maximum case length: 9.6 in.
Minimum case length: 0.8 in.
Example: 2 4 = 2.4 in.
C: Total Length Option
050.5 meter (1.6 feet)
10
151.5 meter (4.9 feet)
20
303.0 meters (9.8 feet)
50
1.0 meter (3.3 feet)
2.0 meters (6.6 feet)
5.0 meters (16.4 feet)
330103 3300 XL 8 mm Probe, M10 x 1 thread,
without armor
330104 3300 XL 8 mm Probe, M10 x 1 thread, with
(2)
armor
Part Number-AA-BB-CC-DD-EE
A: Unthreaded Length Option
Order in increments of 10 mm
Length configurations:
Maximum unthreaded length: 230 mm
Minimum unthreaded length: 0 mm
Example: 0 6 = 60 mm
B: Overall Case Length Option
(2)
Unthreaded length must be at least 20 mm
less than the case length.
13/41