The 21000 and 24701 Proximity Probe Housing Assemblies
consist of the following parts:
l A dome cover that screws into the body of the housing
l Threaded ports for conduit connections
l A probe sleeve of optional length
l 0-rings
l A reverse mount proximity probe
l A thread seal
l Optional conduit fittings
l An optional standoff adapter
141600 Rev. R
A newer 31000/32000 proximity probe housing
assembly is available with more flexible mounting
options, better environmental resistance, and other
improved features. We recommend this proximity
probe housing assembly for installations where an
explosion proof housing is not required. See 31000 and
32000 Proximity Probe Housings product datasheet
(document 141610).
The 21000 and 24701 Proximity Probe Housing Assemblies are
available with Canadian Standards Association (CSA)
approvals. They are rated explosion proof for hazardous
areas.
You can order hazardous area approved proximity probes
with 21000 aluminum and 24701 stainless steel housings for
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
intrinsically safe applications. Both housings
are certified as CSA Type 4 enclosures and are
fully compliant with the American Petroleum
Institute's (API) 670 Standard for externally
mounted proximity probe housings.
The 164818 Compact Proximity Probe Housing is
also available for applications with space
restrictions. Ceramic capped probes are
available with the 164818 housing.
Sleeve length is determined by the location in
which the probe and housing are installed. The
probe lead must be longer than the sleeve.
Sleeve lengths longer than 304 mm (12 inches)
require additional sleeve support to reduce the
vibration associated with unsupported long
sleeve lengths.
Bently Nevada offers a probe support and oil
seal (part number 37948-01) for long sleeves
that must go through an inner bearing
housing. We also make custom sleeve
supports.
Related Documents
For probe information, refer to the following
manuals:
n 3300 XL 8mm & 3300 5mm Proximity
Transducer System User Guide
(Document 141078)
n 3300 XL NSv Proximity Transducer System
User Guide (Document 147357)
n 3300 XL 11mm Proximity Transducer
System Installation User Guide
(Document 146255)
n Radiation Resistant Probe and Proximitor
System (Document TW8029407)
2/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
Monitor Module1 full-height front slot
Specifications
Environmental
I/O Modules1 full-height rear slot
Temperature Range
3300 XL 8 mm Probe
Operating and
storage
3300 XL 11 mm Probe
Operating and
storage
3300 NSV Probe
Operating-34 °C to +177 °C (-30 °F to +
Storage
-51 °C to +177 °C (-60 °F to +
351 °F)
-51 °C to + 177 °C (-60 °F to +
351 °F)
351 °F)
-51°C to +177 °C (-60 °F to
+351 °F)
CAUTION
EQUIPMENT
DAMAGEExposing 3300 XL or
3300 NSV probes to temperatures
below -34 °C (-30 °F) may cause
premature failure of their
pressure seals.
Mechanical
Material
21000Aluminum body with 304
stainless steel sleeve
24701
Mass (Weight)
210001.1 kg (2.4 lb) typical,
247011.8 kg (4.1 lb) typical,
303 stainless steel body,
with 304 stainless steel
sleeve
without fittings
without fittings
3/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
Compliance and
Certifications
FCC
This device complies with part 15 of the
FCC Rules. Operation is subject to the
following two conditions:
l This device may not cause harmful
interference.
l This device must accept any
interference received, including
interference that may cause
undesired operation.
RoHS
RoHS Directive 2011/65/EU
Hazardous Area Approvals
For the detailed listing of country and
product specific approvals, refer to the
Approvals Quick Reference Guide
(108M1756) available from Bently.com.
21000 and 24701
CA housings are certified by CSA for explosion proof applications in the following areas:
North
America
Class 1 Divisions 1 and 2 Groups C
and D
Class 2 Divisions 1 and 2 Groups E, F
and G
Circuit is non-incendive when
connected per drawing 140979
Class III
Enclosure Type 4
T5 @ Ta = -50 °C to +40 °C
T4 @ Ta = -50 °C to +80 °C
4/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
protector, selectable hazardous area
Ordering Information
approvals
For the detailed listing of country and
product specific approvals, refer to the
Approvals Quick Reference Guide
(108M1756) available from Bently.com.
Proximity Probe Housing
Assemblies
21000 - AA-BB-CC-DDD-EE-FF
A: Probe with Connector
00Probe not required
14420 nuclear
15300 nuclear
163300 XL 8 mm probe
263300 XL NSv probe
273300 XL NSv probe, selectable
hazardous area approvals
283300 XL 8 mm probe, selectable
hazardous area approvals
293300 XL 11 mm probe
303300 XL 11 mm probe, selectable
hazardous area approvals
313300 XL NSv probe with connector
protector
323300 XL NSv probe with connector
protector, selectable hazardous area
approvals
373300 XL 8 mm probe, ETR, selectable
hazardous area approvals
(available for 21000 only)
B: Probe Cable Length
00Probe cable not required
050.5 m (20 in)
101.0 m (39 in)
1212.0 in
1818.0 in
2424.0 in
3030.0 in
3636.0 in
C: Standoff Adapter Length (Option C
Dimension)
15Minimum length 1.5 in (38 mm)
75Maximum length 7.5 in (191 mm)
Recommendation
Order in increments of 0.5 in (13 mm)
Examples
1.5 in (38 mm) = 15
No standoff adapter = 00
Must be ordered if Standoff
Adapter Length option is not
00.
333300 XL 8 mm probe with connector
protector
343300 XL 8 mm probe with connector
protector, selectable hazardous area
approvals
353300 XL 11 mm probe with connector
protector
363300 XL 11 mm probe with connector
D: Probe Penetration (Option D Dimension)
10Minimum length 1.0 in (25.4 mm)
Other
5/18
Recommendation
Order in increments of 0.1 in (3 mm)
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
Examples
3.7 in (94 mm) = 037
2.4 in (569 mm) = 224
Probe P/N and S/N may be displayed on a flag
label for some combinations of the C plus D
options where only a small section of the probe
cable is visible.
For probe penetration lengths between 1.0 and
2.0 inches, it may be necessary to counter bore
the machine case to reduce probe side view or
rear view effects.
If you select a probe penetration length (C plus
D) greater than 300 mm (12 in), you must add
sleeve support near the probe to prevent
resonance from occurring. Adjustment range of
probe penetration option D is 13 mm (± 0.5 in).
For the maximum value of C plus D, See
21000/CA21000 Dimensions on page15..
E: Fittings
00Without fittings
One explosion-proof fitting and one plug
01
02Two explosion-proof fittings
03One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
One cable seal grip with grommets for
the following cable sizes:
• 1/8 to 3/16 inches
• 1/4 to 5/16 inches
• 5/16 to 3/8 inches
04One 3/4-14 NPT plug only
Option Standoff Adapter Length
option is not 00.
041/2-14 BSP
24701 -AA-BB-CC-DDD-EE-FF
A: Probe with Connector
00Probe not required
14420 nuclear
163300 XL series 8mm probe
263300 XLNSv probe
273300XL NSv probe, with approval
option
283300 XL series 8mm, with approval
option
293300 XL series 11mm
303300 XL series 11mm, with approval
option
313300 XL NSv with connector protector
323300 XL NSv with connector protector
and approval option
333300XL 8mm with connector
protector
34
3300XL 8mm with connector
protector and approval option
Although explosion-proof fittings are available
for all housings, only CA versions of the housing
are rated as explosion-proof by CSA when
ordered with the E:00, E:01, E:02, or E:04 options.
F: Mounting Thread
01As cast without threads
02
3/4-14 NPT
Will default to 02 option if C:
353300 XL 11mm with connector
protector
363300 XL 11mm with connector
protector and approval option
373300 XL 8mm ETR, with approval
option
B: Probe Cable Length
00Probe cable not required
6/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
0520 in (0.5 m)
1039 in (1.0 m)
1212.0 ft (3.6 m)
1818.0 ft (3.6 m)
2424.0 ft (7.3 m)
3024.0 ft (7.3 m)
3636.0 ft (10.9 m)
C: Standoff Adaptor (Option C Dimension)
15Minimum length 1.5 in (38 mm)
75Maximum length 7.5 in (191 mm)
Examples
1.5 in (38 mm) = 15
No standoff adapter = 00
Recommendation
Order in increments of 0.5 in (13 mm)
D: Probe Penetration (Option DDimension)
If you select a probe penetration
length (C plus D) greater than 300
mm (12 in), you must add sleeve
support near the probe to prevent
resonance from occurring.
Adjustment range of probe
penetration option D is 13 mm (± 0.5
in). For the maximum value of C plus
D, See 21000/CA21000 Dimensions on
page15..
E: Fittings (1)
00Without fittings
01One explosion-proof fitting and one
plug
02
Two explosion-proof fittings
One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
03
One cable seal grip with grommets
for the following cable sizes:
• 1/8 to 3/16 inches
• 1/4 to 5/16 inches
• 5/16 to 3/8 inches
010Minimum length 1.0 in (25.4 mm)
Other
See 21000/CA21000 Dimensions on
page15.
Example
3.7 in (94 mm) = 037
22.4 in (569 mm) = 224
Recommendation
Order in increments of 0.1 in (3 mm)
Probe P/N and S/N may be
displayed on a flag label for
some combinations of the C
plus D options where only a
small section of the probe
cable is visible.
For probe penetration lengths
between 1.0 and 2.0 inches, it may be
necessary to counter bore the
machine case to reduce probe side
view or rear view effects.
04One 3/4-14 NPT plug only
F: Mounting Thread
01As cast without threads
02
3/4-14 NPT (see note(2) below).
Must be ordered if Standoff Adapter
Length Option is not 00.
031-11 1/2 NPT (see note below)
041/2-14 BSP
057/8-14 UNF-2A
Although explosion-proof fittings are available
for all housings, only CA versions of the housing
are rated as explosion-proof by CSA when
ordered with the E:00, E:01, E:02, or E:04 options.
For CA21000 housing, option F must be 02.
Options 02 and 03 for mounting threads have
more threads than standard NPT threads. They
have been machined to have approximately 5 - 7
7/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
full threads to increase mounting strength and
stiffness.
Explosion-Proof Housing
Assemblies
CA21000-AA-BB-CC-DDD-EE-F02
Options A:00 and B:00 are linked. If you choose
A:00, you must also select B:00.
A: Probe with Connector
00Probe not required
01190 series, CSA, BNPSconnector
02190 series, CSA, APIconnector
273300 XL NSv, multiple approval
283300 XL series 8mm, multiple
approval
303300 XL series 11mm, multiple
approval
323300 XL NSv with connector protector,
multiple approval
343300 XL 8mm with connector
protector, multiple approval
363300 XL11mm with connector
protector, multiple approval
B: Probe Cable Length
050.5 metre (20 inches)
201.0 metre (39 inches)
C: Adaptor (Option CDimension)
15Minimum length 1.5 in (38 mm)
75Maximum length 7.5 in (191 mm)
Must be ordered if Standoff Adapter
Length option is not 00.
Example
1.5 in (38 mm) = 15
No Standoff adaptor = 00
8/18
Recommendation
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
Order in increments of 0.5 in (13 mm)
D: Probe Penetration (Option D Dimension)
010Minimum length 1.0 in (25.4 mm)
Other
See 21000/CA21000 Proximity Probe
Housing Assembly on page15.
Example
3.7 in (94 mm) = 037
22.4 in (569 mm) = 224
Recommendation
Order in increments of 0.1 in (3 mm)
Probe P/N and S/N may be
displayed on a flag label for
some combinations of the C
plus D options where only a
small section of the probe
cable is visible.
For probe penetration lengths
between 1.0 and 2.0 inches, it may be
necessary to counter bore the
machine case to reduce probe side
view or rear view effects.
If you select a probe penetration
length (C plus D) greater than 300
mm (12 in), you must add sleeve
support near the probe to prevent
resonance from occurring.
Adjustment range of probe
penetration option D is 13 mm (± 0.5
in).
03
04One 3/4-14 NPT plug only
One cable seal grip with grommets
for the following cable sizes:
• 1/8 to 3/16 inches
• 1/4 to 5/16 inches
• 5/16 to 3/8 inches
Although explosion-proof
fittings are available for all
housings, only CA versions of
the housing are rated as
explosion-proof by CSA when
ordered with the E:00, E:01, E:02,
or E:04 options.
For non-explosion-proof housings, if
you choose a probe with selectable
hazardous area approvals, you must
choose a probe with matching
approval options.
When ordering a proximitor and an
extension cable with the housing,
choose a probe with matching
approval options.
You can only order probes for
CA21000 or CA24701 with
multiple approvals. To order
CA versions with no probe,
select the A:00 option.
CA24701-AA-BB-CC-DDD-EE-FF
For the maximum value of C plus D,
See 21000/CA21000 Proximity Probe
Housing Assembly on page15.
E: Fittings
00Without fittings
01One explosion-proof fitting and one
plug
02
Two explosion-proof fittings
One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
A: Probe with Connector
00Probe not required
01190 series, CSA, BNPSconnector
02190 series, CSA, APIconnector
273300 XL NSv , multiple approval
283300 XL series 8mm, multiple
approval
303300 XLseries 11mm, multiple
9/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
approval
323300 XL NSv with connector protector,
multiple approval
343300 XL 8mm with connector
protector, multiple approval
363300 XL 11mm with connector
protector, multiple approval
B: Probe Cable Length
00Probe cable not required
0520 in (0.5 m)
1039 in (1.0 m)
1212.0 ft (3.6 m)
1818.0 ft (3.6 m)
2424.0 ft (7.3 m)
3024.0 ft (7.3 m)
Order in increments of 0.1 in (3 mm)
Probe P/N and S/N may be
displayed on a flag label for
some combinations of the C
plus D options where only a
small section of the probe
cable is visible.
For probe penetration lengths
between 1.0 and 2.0 inches, it may be
necessary to counter bore the
machine case to reduce probe side
view or rear view effects.
If you select a probe penetration
length (C plus D) greater than 300
mm (12 in), you must add sleeve
support near the probe to prevent
resonance from occurring.
Adjustment range of probe
penetration option D is 13 mm (± 0.5
in). For the maximum value of C plus
D, See 24701/CA24701 Proximity Probe
Housing Assembly on page16.
3636.0 ft (10.9 m)
C: Adapter (Option C Dimension)
15Minimum length 1.5 in (38 mm)
75Maximum length 7.5 in (191 mm)
Examples
1.5 in (38 mm) = 15
No standoff adapter = 00
Recommendation
Order in increments of 0.5 in (13 mm)
D: Probe Penetration (Option DDimension)
010Minimum length 1.0 in (25.4 mm)
Other
See 24701/CA24701 Proximity Probe
Housing Assembly on page16.
Example
3.7 in (94 mm) = 037
22.4 in (569 mm) = 224
Recommendation
E: Fittings
00Without fittings
01One explosion-proof fitting and one
plug
02
Two explosion-proof fittings
One 3/4-14 NPT plug
One 3/4-14 to 1/2-14 NPT reducer
03
One cable seal grip with grommets
for the following cable sizes:
• 1/8 to 3/16 inches
• 1/4 to 5/16 inches
• 5/16 to 3/8 inches
04One 3/4-14 NPT plug only
Although explosion-proof
fittings are available for all
housings, only CA versions of
the housing are rated as
explosion-proof by CSA when
ordered with the E:00, E:01, E:02,
or E:04 options.
10/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
For non-explosion-proof housings, if
you choose a probe with selectable
hazardous area approvals, you must
choose a probe with matching
approval options.
When ordering a proximitor and an
extension cable with the housing,
choose a probe with matching
approval options.
You can only order probes for
CA21000 or CA24701 with
multiple approvals. To order
CA versions with no probe,
select the A:00 option
F: Mounting Thread (1)
01As cast without threads
02
3/4-14 NPT (see note below).
Must be ordered if Standoff Adapter
Length Option is not 00.
031-11 1/2 NPT (see note below)
164818 Compact Proximity Probe
Housing
164818-AA-BB-CCC-DD-EE-FF-GG
A: Probe with Connector
00No probe
013300 XL NSv probe
023300 XL 8 mm probe
033300 XL 11 mm probe
043300 8 mm ceramic-capped probe
053300 XL NSv probe with multiple
approvals
063300 XL 8 mm probe with multiple
approvals
073300 XL 11 mm probe with multiple
approvals
083300 8 mm Ceramic Capped Probe
with multiple approvals
041/2-14 BSP
057/8-14 UNF-2A
For CA21000 housing, option F must
be 02. Options 02 and 03 for
mounting threads have more
threads than standard NPT threads.
They have been machined to have
approximately 5 - 7 full threads to
increase mounting strength and
stiffness.
(1) For CA21000 housing, option F must be 02.
Options 02 and 03 for mounting threads have
more threads than standard NPT threads. They
have been machined to have approximately 5 - 7
full threads to increase mounting strength and
stiffness.
123300 XL 8 mm probe with connector
protector
163300 XL 8 mm probe with connector
protector, multiple approvals
B: Cap Height
202.0 inches
404.0 inches
606.0 inches
C: Sleeve Length
010Minimum length 1.0 in (25.4 mm)
292
Maximum length 29.1 in (167 mm)
Examples
3.0 in (76.2mm) = 030
22.4 in (569 mm) = 224
Recommendation
Order in increments of 0.1 in (3 mm)
11/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
the target material. If only the part number of
D: Mounting Thread
013/4-14 NPT
the original housing is known, and the sleeve
cannot be measured, use the following table to
determine the sleeve length:
02G 3/4 (3/4-14 BSPP)
AAADescription
03M24 x 1.5
E: O-ring Option
01Viton
02Neoprene
03Ethylene propylene
F: Read Thread Type
011/2-14 NPT
02M16 x 1.5
03M20 x 1.5
G: Probe Cable Length
050.5 metre (20 in)
101.0 metre (39 in)
Accessories
Part
Number
Description
Standoff adapter
option from original
housing (21000,
CA21000,24701, or
CA24701 option C)
plus
Probe penetration
option from original
housing (21000,
CA21000, 24701, or
CA24701 option D)
and 045
Standoff Adapter
Option from original
housing (21000,
CA21000,24701, or
CA24701 option C)
plus
Probe penetration
option from original
housing (21000,
CA21000, 24701, or
CA24701 option D)
and 046
All housing AAA options
except NSv and 11 mm
probes (options other than
A:06, A:12, A:26, A:27, A:29,
A:30, A:31, A:32, A:35, or
A:36)
5.5 in (140 mm) = 0 55
except NSv and 11
mm probes
3300 XL NSv probe5.5 in (142 mm) = 05 6
3300 XL 11 mm
4.7 in (119 mm) = 04 7
probe
Maximum Probe Sleeve Length
All 0.5 meter probes
18.0 in (457 mm) = 180
except NSv and 11
mm probes
3300 XLNSv 0.5
18.1 in (460 mm) = 181
meter probe
7200-series 0.5
15.4 in (391 mm) = 15 4
meter 11 mm probe
All 1.0 meter probes
33.7 in (856 mm) = 3 3 7
except NSv and 11
mm probes
3300XL NSv 1.0
33.8 in (859 mm) = 338
meter probe
3300 XL 1.0 meter 11
32.9 in (836 mm) = 32 9
mm probe
7200 Series 1.0
33.1 in (841 mm) = 331
meter 11 mm probe
Individual Standoff Adapter
21003-AAA
A: Individual Standoff Adapter
015
Minimum length 1.5 in (38
mm)
075
Maximum length 7.5 in (191
mm)
Recommendation
Order in increments of 0.5
in (13 mm)
4.5 in (114 mm) = 045
Example 1
For desired probe penetration
lengths of less than 25 mm (1.0
in), order a separate Individual
Standoff Adapter.
The effective probe penetration
length will then be reduced by
the length of the Individual
Standoff Adapter, plus an
additional 13 mm (0.5 in) due to
the NPT thread engagement.
Example 2
To create a probe penetration
length 13 mm (0.5 in), order a
21000 housing with DDD (probe
penetration) option of 030 [76
mm (3 in)] and a separate
individual standoff adapter that
is 51 mm (2.0 in) in length (part
number 21003-020).
The standoff adapter covers 38
mm (2.0 in) of the probe sleeve
plus an additional 13 mm (0.5
in).
Therefore, the effective probe
penetration length drops to 13
mm (0.5 in).
If you use effective
penetration lengths of
less than 1.0 inches,
signal effects are likely
due to probe side view or
rear view of metal
components.
Spare 3300 XL 8 mm Reverse
Mount Probe, 3/8-24 UNF threads
330105-02-12-CC-DD-EE
13/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
A: Total Length
05 0.5 meter (1.6 feet)
10 1.0 meter (3.3 feet)
151.5 meter (4.9 feet)
202.0 meters (6.6 feet)
505.0 meters (16.4 feet)
90
B: Connector
00
02
Agency Approval
00
05
9.0 meters (29.5 feet)
Connector not installed
Miniature ClickLoc coaxial
connector
Not required
Multiple approvals
Spare 3300 XL 11 mm Reverse
Mount Probe, 3/8-24 UNF threads
330705-02-18-CC-DD-EE
C: Total Length
10
505.0 meters (16.4 feet)
90
D: Connector
00
02
E: Agency Approval
00
05
0.5 meter (1.6 feet)
9.0 meters (29.5 feet)
Without connector
With miniature male coaxial
connector
Not required
Multiple approvals
Spare 3300 NSV Reverse Mount
Probe, 3/8-24 UNF threads
330906-02-12-CC-DD-EE
C: Total Length
05
10
505.0 meters (16.4 feet)
70
D: Connector
00
02
E: Agency Approval
00
05
0.5 meter (1.6 feet)
1.0 meter (3.3 feet)
7.0 meters (23.0 feet)
Connector not installed
Miniature ClickLoc coaxial
connector
Not required
Multiple approvals
14/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
Tables
Table 1: For Figure 1, Dimensions in mm (inches).
Catalog NumberDimension
ABC and DE
2100083.3 (3.28)161.6 (6.36)See Ordering Option C &D26.7 (1.05)
2470178.2 (3.08)151.9 (5.97)See Ordering Option C &D27.9 (1.10)
Table 2: Maximum Length of C and D Dimension for Proximity Probes
Probe Cable LengthMaximum C and D Dimension
0.5 metre (3300 Series)343 mm (13.5 in)
1.0 metre742 mm (29.2 in)
Table 3: Maximum C and Dimension with Standard P/N and S/N Label (non-flag label)
Probe Cable LengthMaximum C and D Dimension
0.5 metreNot visible
1.0 metre432 mm (17 m)
17/18
21000 and 24701 Proximity Probe Housing Assemblies
Datasheet141600 Rev. R
Copyright 2020 Baker Hughes Company. All rights reserved.
Bently Nevada, Orbit logo and Proximitor are registered trademarks of Bently Nevada, a Baker Hughes Business, in
the United States and other countries. The Baker Hughes logo is a trademark of Baker Hughes Company. All other
product and company names are trademarks of their respective holders. Use of the trademarks does not imply any
affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does
not make any representation as to the accuracy or completeness of the information and makes no warranties of
any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and
fitness for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect,
consequential or special damages, claims for lost profits, or third party claims arising from the use of the
information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make
changes in specifications and features shown herein, or discontinue the product described at any time without
notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of BakerHughes and its affiliates; and is subject to
change without prior notice. It is being supplied as a service to our customers and may not be altered or its content
repackaged without the express written consent of Baker Hughes. This product or associated products may be
covered by one or more patents. See Bently.com/legal.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 1.775.782.3611 or 1.800.227.5514 (US only)
Bently.com
18/18
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.