Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interference at his own expense.
Canadian Notification
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set
out in the Radio Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux
appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le
Ministère des Communications du Canada.
Japanese Approvals
Korean Approvals
Safety and EMC Approvals and Markings
UL, FCC Class A, cUL, ICES Class A, CE, GS, IRAM, GOST, VCCI Class A, MIC Class A, C-Tick
AutoView® Switch
1415/1515/2015
Instal ler/ User Gu ide
Avocent, the Avocent logo, The Power of Being There, AutoView,
OutLook and OSCAR are registered trademarks of Avocent Corporation
or its affiliates. All other marks are the property of their respective owners.
This symbol is intended to alert the user to the presence of important operating and maintenance
(servicing) instructions in the literature accompanyi ng the appliance.
Dangerous Voltage
This symbol is intended to alert the user to the presenc e of uninsu la te d dang e rou s voltag e with in the
product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Power On
This symbol indicates the principal on/off switch is in the on position.
Power Off
This symbol indicates the principal on/off switch is in the off position.
Protective Grounding Terminal
This symbol indicates a terminal which must be connected to earth ground prior to making any other
connections to the eq uipment.
TABLE OF CONTENTS
Table of Contents
List of Figures ................................................................................................................ vii
List of Tables................................................................................................................... ix
x AutoView 1415/1515/2015 Switch Installer/User Guide
CHAPTER
Product Overvi ew
1
Features and Benefits
The AutoView® 1415/1515/2015 swit ches inte gr ate Avocen t field-proven analog keyboard, video
and mouse (KVM) switching technology with advan ced cable management, flexible access for two
simultaneous users, USB support and a patented, easy-to-use interface. This AutoView series of
KVM switches conveniently supports all major server platfor ms and features powerfu l on-screen
management for easy system configuration and server selection. The AutoView 1415/1515/2015
switches also feature user peripheral ports for PS/2 and USB keyboards and mice.
NOTE: With the exception of USB capability, all references to AutoView 1415/1515/2015 switches are applicable
to AutoView 1400/1500/2000 switches respectively.
1
AVRIQ Intelligent Module
A benefit of the AutoView switch is the AVRIQ intelligent module. The AVRIQ module with
CAT 5 design dramatically reduces cable clutter, while providing optimal resolution and video
settings. The built-in memory of the AVRIQ module simplifies configuration by assigning and
retaining unique server names and Electronic ID (EID) numbers for each attached server. The
AVRIQ module is powered directly from the server and provides Keep Alive functionality even if
the AutoView switch is not powered.
Each AutoView 2015 switch has 16 Avocent Rack Interface (ARI) ports for connecting AVRIQ
modules. AutoView 1415 and 1515 switches p rovide eight ARI ports . Utilizing an AVRIQ module,
you can attach additional switches to expand your AutoView switching system. This flexibility
allows you to add capacity as your data center grows.
Multiplatform support
The AVRIQ modules available with the AutoView switch support PS/2, Sun™, USB and serial
server environments. Using the OSCAR
modules allows you to switch easily across platforms.
The AutoView 1415/1515/2015 switches feature a Share Mode function that allows two users to
gain access to a primary server. The user configurable time-out feature allows you to d etermine the
amount of time (up to 600 seconds) for the target to remain idle before the other user can take
control of the target.
OSCAR graphical user interface
AutoView switches use the OSCAR interface, which features intuitive menu s to conf igur e your
switching system and select servers. server s can be ident ified by un ique name, EID o r port number ,
allowing you to assign unique server names.
Security
The OSCAR interface allows you to protect your system with a screen saver password. After a
user-defined time, the screen saver mode engages and access is prohibited until the appropriate
password is entered to reactivate the system.
Operation modes
The OSCAR user interface provides co nve nient operation modes for easy system administr ation of
the AutoView switch. These modes (Broadcast, Scan, Switch and Share) allow you to manage your
switching activities. Chapter 3 explains these modes in detail.
Video
The AutoView switch provides optimal resolution for analog VGA, SVGA and XGA video.
Achieve resolutions of up to 1600 x 1200 @ 75Hz with a 100 foot (30 meter) cable.
NOTE: Resolutions above 1280 x 1024 may need to be manually set in the operating systems display settings.
Video resolution and distance is subject to cable quality and environmental factors.
Plug and Play
The AutoView switch also supports Display Data Channel (DDC) Plug and Play, which automates
configuration of the monitor and is compliant with the VESA DDC2B standard.
Flash upgradable
Upgrade your firmware at any time through a simple update utility to ensure that your AutoView
switching system is always running the most current version available. Both the AutoView switch
and the AVRIQ modules are Flash upgradable. See Appendix A for more information.
NOTE: Firmware available for the AutoView 1415/1515/2015 switch is also compatible with the AutoView 1400/
1500/2000 switch, but it is not compatible the AutoView 2020/2030 switch.
Chapter 1: Product Overview 3
Cascading expansion
Each AutoView switch supports up to 16 directly attached servers and can conveniently scale to
support more. You can expand your system using cascadable Avocent products such as other
®
AutoView or OutLook
switches. This extra “cascade” of units allows you to attach up to 256
servers in one system. See Chapter 2 for more information.
Local user accounts
The AutoView 1415/1515/2015 switches enable an administrator to configure up to four user
accounts for use with the switch. These user accounts allow the administrator to restrict what ports
a class of user can access, as well as the name of the user account and password. See Chapter 4 for
more information.
Integrated Access Cables
The AutoView 1415/1515/2015 switches also feature Integrated Access Cable (IAC) modules
designed to provide the same ease of use as the AVRIQ module. Available in three different
lengths, IAC modules are RJ-45 style cables that provide a reduced cost alternative to AVRIQ
modules. IAC modules support PS/2 and USB connectivity. Contact your Avocent representative
for more information.
Figure 1.1: Example of an AutoView Switch Configuration
(Cascaded)
Safety Precautions
Analog
Connection
Rack of Servers
Critical Server
AutoView Switch
(Main)
Analog
Connection
To avoid potential vid eo and/or keyboard pro blems when using Avocent products:
•Ιf the building has 3-phase A C pow er, ensure that the computers and monitors are on the sa me
phase. For best results, they should be on the same circuit.
•Use only Avocent-supplied cable to connect computers and KVM switches. Avocent
warranties do not apply to damage resulting from user-supplied cable.
To avoid potentially fatal shock hazard and possible damage to equipment, please observe the
following precautions:
•Do not use a 2-wire extension cord in any Avocent product configuration.
•Test AC outlets at the computer and monitor for proper polarity
and grounding.
Chapter 1: Product Overview 5
•Use only with grounded outlets at both the computer and monitor. When using a backup
Uninterruptible Power Supply (UPS), power the computer, the monitor and the AutoView
switch off the supply.
NOTE: The AC inlet is the main disconnect.
Rack mount safety considerations
•Elevated Ambient Temperature: If installed in a closed rack assembly, the operation
temperature of the rack environment may be greater than room ambient. Use care not to exceed
the rated maximum ambient temperature of the unit.
•Reduced Air Flow: Installation of the equipment in a rack should be such that the amount of
airflow required for safe operation of the equipment is not compromised.
•Mechanical Loading: Mounting of the equipment in the rack should be such that a hazardous
condition is not achieved due to uneven mechanical loading.
•Circuit Overloading: Consideration should be given to the connection of the equi pment to the
supply circuit and the effect that overloading of circuits might have on overcurrent protection
and supply wiring. Consider equipment nameplate ratings for maximum current.
•Reliable Earthing: Reliable earthing of rack mounted equipment should be maintained. Pay
particular attention to supply connections other than direct connections to the branch circuit
Before installing your AutoView switch, refer to the following list to ensure you have all items that
shipped with the AutoView switch, as well as other items necessary for proper installation.
Supplied with the AutoView switch
•Power cord
•One null modem serial cable
•Rack mounting kit
•AutoView 1415/1515/2015 Installer/User Guide
•AutoView 1415/1515/2015 Quick Installation Guide
7
Additional items needed
One IAC or AVRIQ modul e and CAT 5 cabling per attached server or switch
Rack Mounting Your AutoView Switch
Your AutoView switch may be rack moun ted usin g the brackets supplied in your rack mounting kit.
Before installing the switch and other components in the rack cabinet (if not already installed),
stabilize the rack in a permanent location. Install your equipment starting at the bottom of the rack
cabinet, then work to the top.
CAUTION: Rack Loading - Overloading or uneven loading ofracks may result in shelf or rackfailure, causing damage to equipmentand possible personal injury. Do notexceed your rack load rating.
To install the 1U switch mounting bracket:
1.Remove the first two screws on each side of the switch.
2.Line up the holes in the “long side” of the kit’s side brackets with the screw holes in the switch.
3.With a Phillips screwdriver, fasten the mounting brackets to the switch using two screws on
each side.
4.Attach four cage nuts or clip nuts to the rack mounting flange of the rack cabinet so that the nut
is positioned on the inside of the rack.
NOTE: Nuts are not included with the rack mount kit.
5.Mount the switch assembly to the rack cabinet by matching the holes in the “short side” of
each bracket to an appropriate set of matching holes on your rack cabinet.
6.Next, insert the combination hex head screws through the slots in the bracket and the holes in
the mounting rail, then into the cage nuts or clip nuts.
Installing the AutoView Switch
Plug the supplied power cord into the back of the appliance and then into an appropriate power
source. Figure 2.2 illustrates one possible configuration for your AutoView switch. See the fol lowing
detailed set of procedures to successfully install your appliance.
Chapter 2: Installation 9
Analog User B
CAUTION: To r e d u c e th e r i s k o f e l e c t r i c s h o c k or damage t o y o u r eq u ipment -
- Do not disable the power cord grounding plug. The ground ing pl ug is an impo rta nt safety fe ature.
- Plug the power cord into a grounded (earthed) outle t that is easil y accessibl e at all t imes.
- Disconnect the power from the unit by unplugging th e power cord from either t he electri cal outlet or the unit.
Configuration Port
(for updating firmware)
AutoView Switch
Analog User A
IAC Module
AV RIQ Mod ule
Figure 2.2: Basic AutoView Switch Configuration
NOTE: Only the AutoView 1515 and the AutoView 2015 switches support two simultaneous users.
1.Locate the AVRIQ modules for your AutoView switch.
2.Attach the appropriately color-coded cable ends to the keyboard, monitor and mouse ports on the
first server you will be connecting to the appliance.
3.Attach one end of a CAT 5 cable to the RJ-45 connector on the AVRIQ module.
4.Connect the other end of the CAT 5 cable to the desired ARI port on the back of your
AutoView switch.
5.Repeat steps 2 through 4 for each server you wish to attach.
NOTE: When connecting a Sun AVRIQ module, you must use a multi-sync monitor to accommodate Sun
computers that support both VGA and sync-on-green or composite sync.
To connect a server using an IAC module:
1.Locate an IAC module for the server you wish to connect.
2.Attach the appropriately color-coded cable ends of t he IAC module to the keybo ard, monitor and
mouse ports on the server you will be connecti ng to the switch.
3.Attach the other end of the IAC module to an open ARI port.
4.Repeat steps 1 through 3 for each server you wish to attach.
Connecting Users
To connect local peripherals:
1.Select the keyboard, monitor and mouse to be connected to local analog user A.
2.Locate the port set labeled A on the back of the appliance. Connect these peripherals to their
respective ports.
3.Bundle and label the cables for easy identification.
4.Repeat these steps for user B, if desired.
Cascading AutoView Switches
You can cascade multiple AutoView 1415/1515/2015 switches to enable one or two users to
connect to as many as 256 servers. In a cascaded system, each ARI (Avocent Rack Interface) port
on the main AutoView switch will connect to the ACI (Avocent Console Interface) port on each
cascaded AutoView switch. Each cascaded switch can then be connected to a server with an
AVRIQ module or IAC. The example shown in Figure 2.3 shows one AutoView switch cascaded
under the main switch, enabling the connection of up to 15 primary servers and 16 secondary
servers. Using this configur ation, yo u could cascade 16 A utoView swi tches under the mai n switch,
enabling the connection of up to 256 servers. Only one level of tiering is supported in this type of
configuration, which means you cannot cascade any additional legacy switches or another
AutoView switch.
Chapter 2: Installation 11
In this configuration, the local port OSCAR interface is disabled in switches cascaded below the
main AutoView switch.
To cascade multiple AutoView switches:
1.Connect the cascaded AutoView switch to each server as described inthe previous Installing
the AutoView Switch section.
2.Connect the local peripherals to analog user A and/or B of the main switch as described in To
connect local peripherals.
3.Attach one end of the CA T 5 cabling that will run between your main and cascaded AutoView
switch to the RJ-45 ACI port on the cascaded AutoView switch.
4.Attach the other end of the CAT 5 cable to one of the RJ-45 ARI ports on the main
AutoView switch.
NOTE: The system will automatically “merge” the two switches together as one. All servers connected to the
cascaded AutoView switch will display on the main AutoView switch server list in the OSCAR interface.
5.Repeat steps 3 and 4 for all additional (secondary) cascaded AutoView switches you wish
Figure 2.3: AutoView 2015 Switch Configuration with a Cascaded Switch
Adding Legacy Switches
You can add legacy switches to the AutoView switching system for easy integration into your
existing configuration. In a cascaded system, each ARI port will accommodate up to 24 servers.
See the following table for legacy switches compatible with the AutoView switching system.
Table 2.1: Legacy Switch Support
Legacy ProductModel Numbers
OutLook ES switch140ES, 180ES, 280ES, 1160ES, 2160ES, 4160ES
AutoView switchAV200-4, AV200-8, AV400-4, AV400-8, AV416, AV424, AV1415, AV1515, AV2015
AVRIQ Module
PS/2, USB, Sun and serial
cables are available
Chapter 2: Installation 13
Local Analog User A
AutoView 2015 Switch
AVRIQ Module
OutLook ES Switch
Server 1
AutoView 200/400 Switch
Server 2
Figure 2.4: AutoView 2015 Switch Configuration with Legacy KVM Switches
Figure 2.5: AutoView Switch Configuration with AutoView 1415/1515/2015 Switches
NOTE: The PS2IAC modules can be utilized in Figure 2.5.
Secondary
Servers
Chapter 2: Installation 15
T o add a legacy KVM switch:
1.Mount the primary KVM switch into your rack cabinet.
2.Connect one end of a CAT 5 cable to an available port on the back of your AutoView switch.
3.Attach the keyboard, monitor and mouse connectors of the AVRIQ module to a user port on
your cascaded switch.
4.Attach the other end of the CAT 5 cabling to the RJ-45 connector on the AVRIQ module.
5.Connect the servers to your cascaded switch according to the instructions included with
the switch.
6.Power cycle the cascaded switch to enable its local user port to recognize the AVRIQ module.
7.Repeat steps 2 to 6 for all cascaded switches you wish to attach to your system.
To connect local peripherals:
1.Select the keyboard, monitor and mouse to be connected to local user A.
2.Locate the port set labeled A on the back of the switch. Connect these peripherals to their
respective ports.
3.For the multiuser, 16-port AutoView switch, repeat steps 1 and 2 for the local analog port set
labeled B.
- or -
For the AutoView 1415/1515 switch, proceed to step 4.
4.Bundle and label the cables for easy identification.
Setting Up Your AutoView Switching System
The AutoView switching system enables you to auto detect and configure each port on your
appliance. Chapter 3 provides detailed instructions on name customization and OSCAR interface
setup and configuration.
The AutoView switch features one or two analog port sets on the back of the switch that allow you
to connect a monitor and a PS/2 or USB keyboard and mouse for direct analog access. The
AutoView switch uses the OSCAR interface, featuring intuitive menus to configure your system
and select servers.
Viewing and Selecting Ports and Servers
Use the OSCAR interface Main dialog box to view, configure an d con trol s erver s in the AutoView
switching system. View your servers by name, port or by the unique Electronic ID number (EID)
embedded in each AVRIQ module and IAC. You will see an OSCAR interface-generated port list
by default when you first launch the OSCAR GUI.
The Port column indicates the ARI port to which a server is connected. If you connect a legacy KVM
switch to the main AutoView switch or a c asc ade d Aut oView switch, the por t num ber ing displays
the ARI port first, then the switch port to which the server is connected. For example, in Figure 3.1,
servers 04-03 and 01-02 are connected to switches, then to servers on ports 03 and 02 respectively.
17
To access the Main dialog box:
Print Screen to launch the OSCAR interface. The Main dialog box displays.
NOTE: You can also press the Control key twice, t he Alt key twice or the Shift key twice within one second to
launch the OSCAR interface. See Changing the display behavior later in this chapter for further details. You
can use this key sequence in any place you see Print Screen throughout this installer/user guide.
Viewing the status of your switch
The status of the servers in your system is indicated in the right columns of the Main dialog box.
The follow ing table describes the status symb ols.
Table 3.1: OSCAR Interface St atus Symbols
Symbol Description
AVRIQ modules and IACs are online (green circle).
AVRIQ modules and IACs are offline or are not operating properly.
Server is cascaded through a cascade legacy switch. The switch is online and has power.
Server is cascaded through a cascade legacy switch. The switch is offline or has no power.
AVRIQ module is being upgraded (yellow circle).
AVRIQ modules and IACs are being accessed by the indicated user channel (green
channel letter).
AVRIQ modules and IACs are blocked by the indicated user c hannel (black channel letter).
Selecting servers
Use the Main dialog box to select servers. When you select a server, the switch reconfigures the
keyboard and mouse to the proper settings for that server.
To select servers:
Double-click the server name, EID or port number.
-orIf the disp l ay order of your server list is by port (Port
and press
Enter.
button is depressed), type the port number
-orIf the display order of your server list is by name or EID number (Name
or EIDbutton is
depressed), type the first few characters of the name of the server or the EID number to establish it
as unique and press
Enter.
Chapter 3: Basic Operations 19
To select the previous server:
Press
Print Screen and then Backspace. This key combination toggles you between the previous
and current connections.
To disconnect the user from a server:
Press
Print Screen and then Alt+0. This leaves the user in a free state, with no server selected. The
status flag on your desktop displays Free.
Soft switching
Soft switching is the ability to switch serv ers using a hotkey sequence. You can soft switch to a server by
pressing
Print Screen and then typing the first few characters of its name or number. If you have set a
Screen Delay Time and you press the key sequences before that time has elapsed, the OSCAR interface
will not display.
T o configure servers for soft switching:
1.Press
Print Screen to launch the OSCAR interface. The Main dialog box displays.
2.Click Setup - Menu. The Menu dialog box displays.
3.For Screen Delay Time, type the number of seconds of delay desired before the Main dialog
box is displayed after
Print Screen is press e d .
4.Click OK.
T o soft switch to a server:
1.To select a server, press
Print Screen. If the display order of your server list is by port (Port
button is depressed), type the po rt numb er and press
-or-
If the display order of your server list is by name or EID number (Name or EID
depressed), type the first few characters of the name of the server or the EID number to
establish it as unique and press
Enter.
2.To switch back to the previous server, press
Navigating the OSCAR Interface
This table describes how to navigate the OSCAR interface using the keyboard and mouse.
Table 3.2: OSCAR Interface Navigation Basics
This KeystrokeDoes This
Print Screen, C trl-Ctrl
Shift-Shift, and/or
Alt-Alt
Activates the OSCAR interface. See Changing the display behavior later in this
chapter for further details.
Enter.
button is
Print Screen then Backspace.
Print Screen- Print
Screen
Press Print Screen twice to send the Print Screen key stroke to the currently
selected device.
Table 3.2: OSCAR Interface Navigation Basics (Continued)
This KeystrokeDoes This
F1
Escape
Alt+Hotkey
Alt+XCloses the current dialog box and return s t o th e pr ev ious one.
Alt+O
Single-click, Enter
Enter
Print Screen,
Backspace
Print Screen, Alt+0
(zero)
Print Screen, Pa use
Up/Down ArrowsMoves the cursor from line to line in lists.
Right/Left Arrows
Opens the Help screen for the current dialog box.
Closes the current dialog box without saving changes and returns to the previous
one. In the Main dialog box, it closes the OSCAR interface and returns to the flag. In
a message box, it closes the pop-up box and returns to the current dialog box.
Opens dialog boxes, selects or checks options and executes actions when used with
underlined or other designated letters.
Selects the OK button, then returns to the previous dialog box.
In a text box, selects the text for editing and enables the Left and Right Arrow keys
to move the cursor. Press Enter again to quit the edit mode.
Completes a switch in the Main dialog box and exits the OSCAR interface.
Toggles back to previous selection.
Immediately disengages a user from a server; no server is selected. Status flag
displays Free. (This only applies to the 0 on the keyboard and not the keypad.)
Immediately turns on screen saver mode and prevents access to that specific
console, if it is password protected.
Moves the cursor between columns. When editing a text box, these keys move the
cursor within the column.
Page Up/Page DownPages up and down through Name and Port lists and Help pages.
Home/EndMoves the cursor to the top or bottom of a list.
DeleteDeletes characters in a text box.
Page Up/Page DownPages up and down through Name and Port lists and Help pages.
NumbersType from the keyboard or keypad.
Print Screen, Ctrl+ F4
Logs the current user out of the switch (only available when Enable Local User
Accounts is checked on the Security screen).
Configuring OSCAR Interface Menus
You can configure your AutoView switch from the Setup menu within the OSCAR interface. Select
Names
the
other setup features to manage routine tasks for your servers from the OSCAR interface menu.
Table 3.3: Setup Features to Manage Routine Tasks for Your Servers
FeaturePurpose
button when initially setting up your swit ch to id entify servers by unique names. Select the
Chapter 3: Basic Operations 21
Menu
FlagChange display, timing, color or location of the status flag.
Broadcast
ScanSet up a custom scan pattern for up to 16 servers.
SecuritySet passwords to restrict server access. Enable the screen saver.
DevicesIdentify the appropriate number of ports on an attached cascaded switch.
NamesIdentify servers by unique names.
SwitchChoose the Switch Mode and the Share Mode time-out.
KeyboardChoose the keyboard country code that is sent to the AVRIQ module and IAC.
LanguageChoose the language supported by the OSD. Change the OSD text language.
User
NOTE: Please note that the administrative user’s name is case sensitive. You must log in as Admin to utilize
administrative functions.
Only the Menu, Flag and Security screens are available to the users without administrator privileges. All other
screens, except the User screen, are available to the administrator when Enable Local User Accounts is disabled
in the Security screen.
Change the server listing between numerically by port or EID number and
alphabetically by name. Change the Sc r e e n De l a y Time bef or e t h e O S CA R i nterface
displays after pressing Print Screen.
Set up to simultaneously control multiple servers through keyboard and
mouse actions.
Allows the administrator to set up the Local User Accounts (only visible when Enable
Local User Accounts is checked on the Security screen).
To access the Setup menu:
1.Press
Print Screen to launch the OSCAR interface. The Main dialog box displays.
NOTE: Figure 3.3 displays for the Administrator if Local User Accounts are enabled, or for all user if Local User
Accounts are disabled.
Assigning server names
Use the Names dialog box to identify individual servers by name rather than by port number. The
Names list is always sorted by port order. Names are stored in the AVRIQ or IAC module, so even
if you move the module/cable to another ARI port, the name and configuration will be recognized
by the switch.
NOTE: If a server is turned off, its respective AVRIQ or IAC module will not appear in the Names list.
To access the Names dialog box:
1.Press
2.Click Setup
Print Screen to launch the OSCAR interface. The Main dialog box will appear.
- Names. The Names dialog box displays.
Chapter 3: Basic Operations 23
Figure 3.4: Names Dialog Box
NOTE: If the server list changes, the mouse cursor will turn into an hourglass as the list is automati cally u pdated. No
mouse or keyboard input will be accepted until the list update is complete.
To assign names to servers :
1.In the Names dialog box, select a server name or port number and click Modify. The Name
Modify dialog box displays.
Figure 3.5: Name Modify Dialog Box
2.Type a name in the New Name bo x. Names of servers may be up to 15 characters long . Supported
characters include: A to Z, a to z, 0 to 9, space and hyphen.
3.Click OK to transfer the new name to the Names dialog box. Your selection is not saved until
you click OK in the Names dialog box.
4.Repeat steps 1 to 3 for each server in the system.
5.Click OK in the Names dialog box to save your changes.
-or-
Click X or press
Escape to exit the dialog box without saving changes.
NOTE: If an AVRIQ module has not been assigned a name, the EID is used as the default name.
Assigning device types
The AutoView switch automatically discovers cascaded KVM switches, but you will need to specify
the number of ports on the cascaded swi tch t hro ugh th e Devices di alog b ox. Y o u will s ee an S w-8 or
Sw-24 display in the Type category for the cascaded switch. Select the switch from the list and the
Modify button displays, all owi ng y ou t o as sign it the appropriate number of ports.
NOTE: The Modifybutton will only be available if a configurable switch is selected.
To access the Devices dialo g box:
1. Press
2. Click Setup - Devices. The Devices dialog box displays.
Print Screen to launch the OSCAR interface. The Main dialog box will appear.
Figure 3.6: Devices Dialog Box
When the AutoView switch discovers a cascaded switch, you will notice the port numbering
change to accommodate each server under that switch. For example, if the switch is connected to
ARI port 6, the switch port would be listed as 06 and each server under it would be numbered
sequentially 06-01, 06-02 and so on.
To assign a device type:
1.In the Devices dialog box, select the desired por t number.
2.Click Modify. The Device Modify dialog box displays.
Figure 3.7: Device Modify Dialog Box
3.Choose the number of port s suppor ted by y our cascaded swit ch and click OK. If the number of
desired ports is not listed, click Other and type in port number between 4 and 24 ports.
4.Repeat steps 1 to 3 for each port requiring a device type to be assigned.
5.Click OK in the Devices dialo g box to save settin gs .
NOTE: Changes made in the Device Modify dialog box are not saved until you click OK in the Devices
dialog box.
Changing the display behavior
Chapter 3: Basic Operations 25
Use the Menu dialog box to change th e di spla y order of s e rvers, chang e the key s e quen ce to l aunch
the OSCAR interface and set a Screen Delay Time for the OSCAR interface. The display order setting
alters how servers displa y in several s creens incl uding t he Main, D evices and Broadcast dialog boxes.
T o access the Menu dialog box:
1.Press
Print Screen to launch the OSCAR interface. The Main dialog box displays.
2.Click Setup - Menu in the Main dialog box. The Menu dialog box displays.
1.Select Name to display servers alphabetically by name.
-or-
Select EID to display servers numerically by EID number.
-or-
Select Port to display servers numerically by port number.
2.Click OK.
To set up key sequences to launch the OSCAR interface:
1.Click the box next to the key sequen ce yo u want to start the OSCAR interface. Unchecking all
boxes will leave
Print Screen as the default.
2.Click OK.
To set a Screen Delay Time for the OSCAR interface:
1.Type in the number of seconds (0 to 9) to delay the OSCAR interface display after you press
Screen
. Entering 0 will instantly launch the OSCAR interface with no delay.
2.Click OK.
Setting a Screen Delay Time allows you to complete a soft switch without the OSCAR interface
displaying. To perform a soft switc h, see Soft switching i n this ch apt er.
Setting the keyboard country code
The AutoView 1415/1515/2015 switch can be configured to recognize a variety of keyboards. The
default setting is for a US keyboard. If you wish to change this configuration, the Keyboard dialog
box allows you to select a different keyboard country code.
NOTE: Ensure that the country code selected on your Sun server matches the Keyboard Country Code selected
in the OSCAR interface or your keyboard will not be mapped correctly.
Print
Figure 3.9: Keyboard Box
To change the keyboard country code:
Chapter 3: Basic Operations 27
1.Press
Print Screen to launch the OSCAR interface. The Main dialog box will appear.
2.Click Setup-Keyboard. The Keyboard dialog box displays.
3.Select your desired k eyboard country code an d click OK.
4.A Keyboard Warning dialog box will appear to confirm your changes.
5.Click OK for changes to take effect.
Figure 3.10: Keyboard Warning Dialog Box
Selecting a language
The Language dialog box allows you to select the language supported by the OSD and change the
OSD text to that language.
T o select a language:
1.Press
Print Screen to launch the OSCAR interface. The Main dialog box will appear.
2.Click Setup-Language. The Language dialog box displays.
The status flag displays on your desktop and shows the name or EID number of the selected server
or the status of the selected port. Use the Flag dialog box to configure the flag to display by server
name or EID number, or to ch ange the fl ag col or , o pacit y, di sp lay t i me an d locat ion o n t h e des kto p.
Table 3.4: OSCAR Interface Status Flags
FlagDescription
Flag type by name
Flag type by EID number
Flag indicating that the user has been disconnected from all systems
Flag indicating that Broadcast Mode is enabled
To access the Flag dialog box :
1. Press
Print Screen. The Main dialog box will appear.
2. Click Setup - Flag. The Flag dialog box displays.
Chapter 3: Basic Operations 29
Figure 3.12: Flag Dialog Box
To determine how the status flag is displayed:
1.Select Name or EID to determine what information will be displayed.
2.Select Displayed to show the flag all the time or select Timed to display the flag for only five
seconds after switching.
3.Select a flag color in Display Color.
4.In Display Mode, select Opaque for a solid color flag or select Transparent to see the desktop
through the flag.
5.To position the status flag on the desktop:
a.Click Set Pos ition to gain access to the Set Position Flag screen.
b.Left-click on the title bar and drag to the desired location.
c.Right-click to return to the Flag dialog box.
Figure 3.13: Set Position Flag
NOTE: Changes made to the flag position are not saved until you click OK in the Flag dialog box.
6.Click OK to save set tings.
-or-
Click X to exit without saving changes.
Setting console security
The OSCAR interface enables you to set security on your analog port console. You can establish a
screen saver mode that engages after your console remains unused for a specified Inactivity Time.
Once engaged, your console will remain locked until you press any key or move the mouse. You
will then need to type in your password to continue.
Use the Security dialog box to lock your console with password protection, set or change your
password and enable the screen saver.
NOTE: If a password has been previously set, you will have to enter the password before you can access the
Security dialog box. If you should lose or forget your password, please contact Avocent Technical Support about
returning your switch for service. See Appendix D:Technical Support for contact information.
T o access the Security dialog box:
1.Press
Print Screen to launch the OSCAR interface. The Main dialog box will appear.
2.Click Setup - Security. The Security dialog box displays.
Figure 3.14: Security Dialog Box
NOTE: Figure 3.12 is the Security screen for the administrator and local user when the Enable User Accounts
feature is turned off. The restricted user can only access the Change Password function of this screen.
T o set or change the password:
1.Single-click and press
2.Type th e new pas sword i n the Ne w tex t box and press
Enter or double-click in the New text box.
Enter.
Passwords must contain both alpha and numeric characters, are case sensitive and may be up to
12 characters long. Supported characters are: A to Z, a to z, 0 to 9 , sp ace and h yphen .
3.In the Repeat box, type the password again and press
Enter.
4.Click OK to change only your password, and then close the dialog box.
To password protect your console:
1.Set your password as described in the previous procedure.
2.Select Enable Screen Saver.
Chapter 3: Basic Operations 31
3.Type the number of minutes for Inactivity Time (from 1 to 99) to delay activation o f pas sword
protection and the screen saver feature.
4.For Mode, select
CAUTION: Monitor damage can result from the use of Energy mode with monitors not compliant with
ENERGY STAR.
Energy
if your monitor is E
NERGY STAR
®
compliant; otherwise select
Screen
5.(Optional) Click Test to activate the screen saver test which lasts 10 seconds then returns you to
the Security dialog box.
6.Click OK.
To log in to your console:
1.Press any key or move the mouse.
2.The Password dialog box displays. Type your password, then click OK.
3.The Main dialog box displays if the password was entered prop erly.
To remove password protection from your console:
1.From the Main dialog box , click Setup - Security; the Password dialog box displays. Type your
password, then click OK.
2.In the Security dialog bo x, s ing le- cl ick and pres s
the box blank. Press
3.Single-click and press
Enter.
Press
Enter.
Enter or double-click in the Repeat box. Leave the box blank.
Enter or double-click in the Ne w bo x. Leave
4.Click OK to eliminate your password.
.
To enable local user accoun ts:
1.Click the Enable Local User Accounts checkbox.
2.Click OK. See Chapter 4 for more information on setting up local user accounts.
T o disable local user accounts (Admin user only):
1.Click Enable Local User Accounts to uncheck the box and disable this option.
2.Click OK.
T o enable the screen saver mode with no password protection:
1.If your console does not require a password to gain access to the Security dialog box, proceed
to step 2.
-or-
If your console is password protected, see the previous procedure, then go to step 2.
2.Select Enable Screen Saver.
3.Type the number of minutes for Inactivity Time (from 1 to 99) to delay activation of the
4.Choose Energy if your monitor is ENERGY STAR compliant; otherwise select Screen.
CAUTION: Monitor damage can result from the use of Energy mode with monitors not compliant with
ENERGY STAR.
5.(Optional) Click Test to activate the screen saver test which lasts 10 seconds then returns you
to the Security dialog box.
6.Click OK.
NOTE: Activation of the screen saver mode disconnects the user from a server; no server is selected. The status
flag displays Free.
T o exit the screen saver mode:
Press any key or move your mouse. The Main dialog box displays and any previous server
connection will be restored.
T o turn off the screen saver:
1.In the Security dialog box, clear Enable Screen Saver.
2.Click OK.
T o immediately turn on the screen saver:
Press
Print Screen, then press Pause.
Displaying Version Information
The OSCAR interface enables you to display the versions of the AutoView switch, as well as the
AVRIQ module and IAC module firmware. For optimum performance, keep your firmware
current. For more information, see Appendix A.
To display version information:
Chapter 3: Basic Operations 33
1.Press
2.Click Commands
Print Screen. The Main dialog box will appear.
- Display Versions. The Ve r sion di alo g bo x displays. The top half of the box
lists the subsystem versions in the appliance.
Figure 3.15: Version Dialog Box
3.Click the Target button to view individual AVRIQ and IAC module version information. The
4.Select an AVRIQ or IAC module to view and click the Version button. The Target Version
dialog box displays . For more information on loading firmware, see Appendix A.
Figure 3.17: Target Version Dialog Box
5.Click the Load Firmwar e button to view the load firmware screen. The Load Firmware button
will not appear in the user version of the Target Selection Dialog Box.
NOTE: The Load Firmware button will only display for an AVRIQ module; IAC modules are not upgradable.
Only the administrator and the user (when local user accounts are disabled) can upgrade the firmware on an
AVRIQ module.
Chapter 3: Basic Operations 35
Figure 3.18: Firmware Warning Dialog Box
To decommission an AVRIQ module:
Decommissioning an AVRIQ module restores the factory defaults in Sun, USB and PS/2 AVRIQ
modules only.
1.Press
2.Click Commands
Print Screen. The Main dialog box will appear.
- Display Versions. The Ve r sion dialog box displays.
3.Click the Target button to view individual AVRIQ module version information. The Target
Selection dialog box displays.
4.Click the Decommission button.
5.Click OK to to reset th e AVRIQ module to factory default.
NOTE: Clicking OK in the Decommision screen will remove any assigned server names and will reset all
configurable items while leaving the EID setting intact.
6.Click X to close the dialog box.
NOTE: The Load Firmware button will only display for an AVRIQ module; IAC modules are not upgradable.
Only the administrator and the user (when local user accounts are disabled) can upgrade the firmware on an
AVRIQ module.
Scanning Your System
In Scan Mode, the appliance automatically scans from port to port (server to server). You can scan
up to 16 servers, specifying which servers to scan and the number of seconds that each server will
display. The scanning order is determined by placement of the server in the list. The list is always
shown in scanning order. You can, h owever, choose t o display the server ’s name or EID n umber by
pressing the appropriate button.
2.Click Setup - Scan. The Scan dialog box displays.
Figure 3.19: Scan Dialog Box
3.The dialog box contains a listing of all servers attached to your appliance. Click the checkbox
next to the servers you wish to s can.
-or-
Double-click on a server’s name or port .
-or-
Alt and the number of the server you wish to scan. You can select up to 16 servers from the
Press
entire list.
4.In the Scan Time box, type the number of seconds (from 3 to 99) of desired time before the
scan moves to the next server in the sequence.
5.Click OK.
T o remove a server from the scan list:
1.In the Scan dialog box, deselect the checkbox next to the server to be removed.
-or-
Double-click on the server’s name or port .
-or-
Click the Clear button to remove all servers from the scan list.
2.Click OK.
T o start the Scan Mode:
1.If the OSCAR interface is not open, press
Print Screen. The Main dialog box will appear.
2.Click Commands. The Commands dialog box displays.
Chapter 3: Basic Operations 37
Figure 3.20: Commands Dialog Box
NOTE: Figure 3.17 shows the Commands screen for the administrator and local user when the Enable User
Accounts feature is turned off. The restricted user will only have access to the Display Versions, Device Reset
and Log Out buttons.
3.Select Scan Enable in the Commands dialog box.
4.Click X to close the Commands dialog box.
NOTE: Scanning will begin when the Main dialog box or flag is displayed. Scanning is inhibited in any other
OSCAR interface dialog box.
T o cancel Scan Mode:
1.Select a server if the OSCAR interface is open.
-or-
Move the mouse or press any key on the keyboard if the OSCAR interface is not open.
Scanning will stop at the currently selected server.
2.Press
Print Screen. The Main dialog box will appear.
3.Click Commands. The Commands dialog box displays.
4.Clear Scan Enable.
Running System Diagnostics
You can validate the integ rity of your system through the Run Diagnostics command . Thi s comman d
checks the main board functional s ub- sys t ems ( memory, communications, switch control and the
video channels) for each system controller. When you select the Run Diagnostics option, you will
receive a warning indicating that all users (remote and local) will be disconnected. Click OK to
confirm and begin the test.
The Diagnostics dialog bo x di s pla ys . Th e top s ect i on o f t he dial og box di s pla ys the har dw are t est s .
The bottom portion divides the tested AVRIQ and IAC modules into three categories: On-line,
Offline or Suspect.
NOTE: AVRIQ or IAC modules may appear to be offline while being upgraded.
Figure 3.21: Diagnostics Dialog Box
Next to each item to be tested, you will see a pass (green circle) or fail (red x) symbol display to
the left of each item as that test finishes. The following table details each of the tests.
Table 3.5: Diagnostic Test Details
TestDescription
Memory TestsReports on the condition of the main board RAM
Firmware CRCs
Comm InterfacesValidates the current firmware images stored in the system’s Flash
Switch Controller testVerifies the switch matrix controller is accessible and functional
Local Video
On-line Targets
Offline Targets
Suspect Targets
Reports on the condition of the main board RAM
Indicates the condition of the local video monitor
Indicates the total number of currently connected and powered targets
Indicates the number of targets that have been connected successfully in the
past and are powered down
Indicates the number of targets that have been detected, but are either
unavailable for connection or have dropped packets during the ping tests
To run diagnostic tests:
1.If the OSCAR interface is not open, press
2.Click Commands
- Run Diagnostics. A warning message displays indicating that all users will
Print Screen. The Main dialog box will appear.
be disconnected.
Figure 3.22: Diagnostics Warning Dialog Box
3.Click OKto begin diagnostics.
-or-
Click X or press
Escape to exit the dialog box without running a diagnostic test.
4.All users are disconnected and the Diagnostics dialog box displays.
5.As each test is finished, a pass (green circle) or fail (red x) symbol displays. The test is com-
plete when the last test’s symbol displays.
Broadcasting to Servers
Chapter 3: Basic Operations 39
The analog user can simultaneously control more than one server in a system to ensure that all
selected servers receive identical input. You can choose to broadcast keystrokes and/or mouse
movements independently.
NOTE: You can broadcast to up to 16 servers at a time, one server per ARI port.
NOTE: Broadcasting Keystrokes - The keyboard state must be identical for all servers receiving a broadcast to
interpret keystrokes identically. Specifically, the Caps Lock and Num L ock mode s must be the same on all
keyboards. While the appliance attempts to send keystrokes to the selected servers simult ane ously, some servers
may inhibit and thereby delay the transmission.
NOTE: Broadcasting Mouse Movements - For the mouse to work accurately, all systems must have identical
mouse drivers, desktops (such as identically placed icons) and video resolutions. In addition, the mouse must be
in exactly the same place on all screens. Because these conditions are extremely difficult to achieve,
broadcasting mouse movements to multiple systems may have unpredictable results.
To broadcast to select ed serve rs:
1.From the Broadcast dialog box, s elect the mouse and/or keyboard checkboxes for the servers
that are to receive the broadcast commands.
-or-
Press the
select the keyboard checkbox and/or
Up or Down Arrow keys to move the cursor to the target server. Then press Alt+K to
Alt+M to select the mouse checkbox. Repeat for
additional servers.
2.Click OK to save the settings and return to the Setup dialog box. Click X or press
Escape to
return to the Main dialog box.
3.Click Commands. The Commands dialog box displays.
4.Click the Broadcast Enable checkbox to activate broadcasting. The Broadcast Enable
5.Click OK to enable the broadcast. Click X or press Escape to cancel and return to the Com-
mands dialog box.
6.If broadcasting is enabled, type the information and/or perform the mouse movements you
want to broadcast from the switch. Only servers in the list are accessible.
NOTE: The other user is disabled when Broadcast Mode is enabled.
To turn broadcasting off:
From the Commands dialog box, clear the Broadcast Enable checkbox.
Changing Your Switch Mode
Your AutoView switch allows you to connect to attached servers using two methods: Preemptive
and Cooperative.
Select Preemptive (default setting) to allow any user to select any server at any time; a request from
another user disconnects the curren t user without warning.
-orSelect Cooperative to maintain the current user connection; the current user will not be
disconnected if another user requests connection.
T o access the Switch dialog box:
1.Press
2.Click Setu p - Switch. The Switch dialog box displays.
3.Select either Preemptive or Cooperative as your Switch Mode.
4.Click OK to save changes. Click X or press
Setting the Share Mode feature
The Share Mode feature of the AutoView 1415/1515/2015 switches allows two users to gain
access to a primary server.
To enable Share Mode :
Escape to cancel.
1.Press
Print Screen. The Main dialog box will display.
2.Click Setu p - Switch. The Switch dialog box displays.
3.Select Share Enable from the Switch dialog box.
4.Choose the amount of i nactiv ity time fo r the target (u p to 60 0 secon ds) bef ore another user can
take control of the target.
5.Click OK to save changes. Click X or press
Escape to cancel.
CHAPTER
Advanced Operations
4
Using Administrator Privileges
The AutoView 1415/1515/201 5 sw it ches allo w up to four user s and one admini s trat or to l og into a
switch, with the administrator having the ability to restrict users from accessing the targets via the
Security menu. The administrator can edit, access and/or delete user accounts.
43
Figure 4.1: Security Menu
T o access the User Setup screen (administrator only):
1.Click the Enable User Account checkbox in the Security menu. The Setup menu will appear.
2.Click the OK button.
3.Click the User button on the Setup screen to enter the User Setup screen.
NOTE: Clicking the User button on the Setup screen will automatically log out any currently logged in user. Other
users will remain logged out until your changes are complete.
The User Setup menu allows the administrator to edit, access and/or delete a user account. The
menu is only accessible if the Enable User Account checkbo x is enabled in the Security men u. The
AutoView 1415/1515/2015 switches will have four standard user accounts, with the default names
of User1, User2, User3 and User4.
T o edit a user:
1.Click the username of the user to be modified .
2.Click Edit to change the username and/or password of the selected user.
3.Click Access to restrict port access for the selected user.
4.Click Delete to restore the selected user to the default state (default name, no password, no
port access).
5.Click OK on the User Setup screen to save changes, or click the Exit button to escape without
saving any changes.
User Edit menu (administrator only)
The Edit menu allows the administrator to set or change user names and passwords for all users.
Chapter 4: Advanced Operations 45
Figure 4.3: User Edit Menu (Administrator Only)
The Username field displays default names that can be edited by the administrator. Usernames
must be between 1 to 15 characters. Administrators can also set user passwords in the User Edit
menu. Passwords must be between 5 to 12 characters an d must contain at least one nu mber and o ne
alpha character. Administrators must verify new passwords by retyping the password in the Repeat
Password field.
NOTE: Changes are not saved until the administrator clicks OK in the User Setup menu.
User Access menu (administrator only)
The Access menu displays each user name, port number and whether the user has access to the
listed KVM ports. The administrator controls which ports are accessible to which user by clicking
in the appropriate checkbox.
The Clear All button allows the administrator to clear access to all ports for a given user instead of
deleting the account. The Check All button allows the administrator to assign all available KVM
ports to any user.
NOTE: Changes are not saved to memory until the administrator clicks OK on the User Setup screen.
User Setup menu - Delete (administrator only)
The Delete button in the User Access menu allows an administrator to delete user accounts. Simply
select an account from the menu and click the Delete button. The deleted user account will
immediately return to default settings.
APPENDICES
Appendices
Appendix A: Flash Upgrades
Upgrading the AutoV iew swi tc h
You can upgrade the firmware of your AutoView switch by using a special update uti lity pro vided
by Avocent. This utility automatically configures the port communications settings to allow direct
downloading from the connected server.
Items needed for the upgrade
®
•Server running Windows NT
•Available serial port (COM por t) on the server
•Null modem serial cable (DB-male) that connects the switch and the server
•Firmware update
To upgrade firm ware:
1.Connect the standard serial cable to a C OM port on the s erver and to the serial connector on the
back panel of the switch. Make a note of which COM port you have chosen, then turn on
the switch.
2.Go to http://www.avocent.com/support and click on All Product Upgrades to access the
firmware upgrade file. Once the download is complete, navigate to the drive where you have
saved the firmware update and unzip the file.
3.Double-click to run the ApplianceUpdate.exe utility.
4.Click the Next button to display the Main dialog box.
5.In the dialog box that displays, select the appropriate COM Port from the COM Port menu.
6.Click Update.
7.Once the firmware is updated, an Update Complete message displays. Click the Close button
to exit the dialog box.
8.The switch automatically reboots after the upgrade is completed.
, Windows® 95, Windows 98 or Windows 2015
47
Possible error conditions
If the download does not execute properly, verify the following:
•Verify that the COM port is correct.
•Verify that no other program is currently using the COM port, or that no previous DOS win-
dow/shell is open that had used the desired COM port.
•Verify that no other copies of the ApplianceUpdate.exe utility are currently running.
•In the selected COM port Advanced Port settings, verify that the FIFO buffers are selected and
that the receive buffer is set to High.
CAUTION: While upgrading, do not use your server for anything else or switch between windows. Close all other
windows if necessary. If the upgrade was unsuccessful (such as during a power outage), repeat
the procedure.
Upgrading the AVRIQ module firmware
The AVRIQ modules can be upgraded individually or simultaneously.
NOTE: IAC modules are not upgradable.
To simultaneously upgrade multiple AVRIQ modules:
1.Press
Print Screen. The Main dialog box will appear.
2.Click Commands - AVRIQ Status. The AVRIQ Status dialog box displays.
Figure A.1: AVRIQ S tatus Dialog Box
NOTE: You can automatically upgrade any AVRIQ module connected to your AutoView switch by selecting the
Auto-upgrade box in the AVRIQ Status dialog box.
3.Click one or more types of modules to upgrade. Click Upgrade.
4.The AVRIQ Upgrade dialo g box displays. Click OK to initiate the upgrade and return to th e
Number8 (AutoView 1415/1515 switch), 16 (AutoView 2015 switch)
TypesPS/2, Sun, USB and serial AVRIQ modules or PS/2 and USB IACs
ConnectorsRJ-45
Sync TypesSeparate horizontal and vertical
Plug and PlayDDC2 B
Video ResolutionAnalog Port Maximum 1600 x 1200 @ 75 Hz
Certain keys on a standard Typ e 5 (US) Sun keybo ard can b e emulated b y key press sequences on a
PS/2 keyboard. To enable Sun Advanced Key Emulation mode and use these keys, press and hold
Ctrl+Shift+Alt and then press the Scroll Lock key. The Scroll Lock LED blinks. Use the indicated
keys in Table C.1 as you would use the advanced keys on a Sun keyboard.
(1)Windows 95 104-key keyboard.
(2)The Command key is the Sun Meta (diamond) key.
(2)
(2)
(2)
F12
Win (GUI) left
Win (GUI) right
(1)
(1)
Appendices 53
For example: For Stop + A, press and hold Ctrl+Shift+Alt and press Scroll Lock, then F1 + A.
These key combinations will work with the AVRIQ-USB module (if your Sun system comes with a
USB port) as well as the Sun AVRIQ-VSN and AVRIQ-WSN mod ules. With the exception of
these key combinations are not recognized by Microsoft Windows. Using
F12 performs a Windows
key press.
When finished, press and hold
Ctrl+Shift+Alt and then press the Scroll Lock key to toggle Sun
Advanced Key Emulation mode off.
Special considerations for Japanese Sun USB and Korean Sun USB
keyboards (A VR IQ-USB modules only)
Japanese Sun USB and Korean Sun USB keyboards assign usage IDs for certain keys that differ
from standard USB usage IDs. If AVRIQ-USB modules are attached to your Sun servers, the Han/
Zen and Katakana/Hiragana keys on Japanese Sun USB keyboards and Hangul and Hanja keys on
Korean Sun USB keyboards must be accessed using alternate keystrokes.
Due to these keyboard-specific differences, keyb oard mapping in consistencies may be encou ntered
when switching between target devices using Sun AVRIQ-VSN and AVRIQ-WSN modules and
target devices using AVRIQ-USB modules. These keys function normally if your Sun servers are
attached to the AutoView 1415/1515/20 15 switch using an AVRI Q-VSN or AVRIQ-WSN modul e.
Table C.2 lists the keyboard mapping that will take place when an AVRIQ-USB module is used in
this setting.
F12,
Table C.2: PS/2-to-USB Keyboard Mappings
PS/2 KeyboardUSB Usage ID Sun USB Keyboard
Right-Alt0xE6AltGraphHangulKatakana/Hiragana
Windows Application 0x65ComposeHanjaCompose
Hangul0x90N/AN/AN/A
Hanja0x91N/AN/AN/A
Katakana/Hiragana0x88N/AN/AHan/Zen
Han/Zen0x35` ~` ~N/A
Our Technical Support staff is ready to assist you with any installation or operating issues you
encounter with your Avocent product. If an issue should develop, follow the step s below for the
fastest possible service.
To resolve an issue:
1.Check the pertinent section of this manual to see if the issue can be resolved by following the
procedures outlined.
2.Check our web site at www.avocent.com /sup por t to search the knowledge base or use the on-
line service request.
3.Call the Avocent Technical Support location nearest you.