No part of this manual, including the products and software described in it, may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any language in any form or by any means,
except documentation kept by the purchaser for backup purposes, without the express written permission
of ASUSTeK COMPUTER INC. (“ASUS”).
ASUS provides this manual “as is” without warranty of any kind, either express or implied, including but not
limited to the implied warranties or conditions of merchantability or tness for a particular purpose. In no
event shall ASUS, its directors, ofcers, employees, or agents be liable for any indirect, special, incidental,
or consequential damages (including damages for loss of prots, loss of business, loss of use or data,
interruption of business and the like), even if ASUS has been advised of the possibility of such damages
arising from any defect or error in this manual or product.
Specications and information contained in this manual ae furnished for informational use only, and are
subject to change at any time without notice, and should not be construed as a commitment by ASUS.
ASUS assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual,
including the products and software described in it.
Product warranty or service will not be extended if: (1) the product is repaired, modied or altered, unless
such repair, modication of alteration is authorized in writing by ASUS; or (2) the serial number of the
product is defaced or missing.
Products and corporate names appearing in this manual may or may not be registered trademarks or
copyrights of their respective companies, and are used only for identication or explanation and to the
owners’ benet, without intent to infringe.
Chapter 1: Product introductionII
Page 3
Contents
Contents ...................................................................................................... III
Revision history .......................................................................................... III
Safety information ...................................................................................... IV
Chapter 1: Product introduction
1.1 Key features .................................................................................. 1-2
1.2 System overview .......................................................................... 1-3
1.3 Front panel features ..................................................................... 1-5
1.4 Rear panel features ...................................................................... 1-5
2.8 OS support list ........................................................................... 2-10
Revision history
RevisionRevision historyDate
V1First release of RS300-E6 Series conguration guideSeptember 2009
ASUS RS300-E6 SeriesIII
Page 4
Safety information
Electrical Safety
• Before installing or removing signal cables, ensure that the power cables for
the system unit and all attached devices are unplugged.
• To prevent electrical shock hazard, disconnect the power cable from the
electrical outlet before relocating the system.
• When adding or removing any additional devices to or from the system, contact
a qualied service technician or your dealer. Ensure that the power cables for
the devices are unplugged before the signal cables are connected. If possible,
disconnect all power cables from the existing system before you service.
• If the power supply is broken, do not try to x it by yourself. Contact a qualied
service technician or your dealer.
Operation Safety
• Servicing of this product or units is to be performed by trained service
personnel only.
• Before operating the server, carefully read all the manuals included with the
server package.
• Before using the server, make sure all cables are correctly connected and the
power cables are not damaged. If any damage is detected, contact your dealer
as soon as possible.
• To avoid short circuits, keep paper clips, screws, and staples away from
connectors, slots, sockets and circuitry.
• Avoid dust, humidity, and temperature extremes. Place the server on a stable
surface.
This product is equipped with a three-wire power cable and plug for the user’s
safety. Use the power cable with a properly grounded electrical outlet to avoid
electrical shock.
Lithium-Ion Battery Warning
CAUTION! Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer’s
instructions.
CD-ROM Drive Safety Warning
CLASS 1 LASER PRODUCT
Heavy System
CAUTION! This server system is heavy. Ask for assistance when moving or
carrying the system.
Chapter 1: Product introductionIV
Page 5
Chapter 1
This chapter describes the key features
of RS300-E6 Series. It includes
the product overview and general
specications.
Product introduction
Page 6
1.1 Key features
Green Server with High Expandability & Upgradability
Support Up-to-date Intel CPU
The RS300-E6/PS4 is built with LGA Socket 1156, support 45nm Quad Core UP
CPU and dual-channel DDR3-1333, and it is also designed ready for next-gen
32 nm Dual Core UP CPU to allow effortless migration to Intel’s new platform
and therefore prolong your investment. The ASUS proprietary CPU heat-pipe will
deliver high thermal performance for stable computing applications.
High I/O Expandability
The RS300-E6 supports 2+1 I/O expansion slots in the 1U chassis, including one
PCI-E x8 slot to support low-prole/half-length card, one PCI-E x16 slot to support
full-height/half-length card, and another slot designed for ASUS optional PIKE card,
which brings seamless upgrade to SAS storage and RAID protection.
Green Design with 80+ PSU & Intelligent Fan Control
With current trends leaning towards power efciency, the RS300-E6/PS4 is
equipped with 80+ PSU to reduce the power loss and power consumption, and
save power bill for users. The ASUS intelligent FAN technology will optimize the
total FAN power and acoustic level to create a pleasant working environment for
customers.
Optional ASUS PIKE for Demand on Upgradability
In order to upgrade from SATA storage to SAS directly, ASUS recommends
customers to use its optional PIKE Upgrade Kit, which is compatible with IntelR
XEON 5500 & 3400 Series platform products. With PIKE, slim-sized and exible
storage options for customers can be achieved when upgrading directly to SAS
RAID with multiple I/O solutions, without sacricing expansion capabilities. Now
maximize your I/O performance and data protection in second!
Remote Management Solution °V ASUS ASMB4 iKVM
The optional ASMB4-iKVM upgrade kit provides remote real-time full control
access to the system based on BIOS-level by keyboard, video monitor and mouse
(KVM over Ethernet) from any local computer anywhere, anytime.
Save Effort with Auto-install CD
With the auto-install support CD, you don’t need to wait and click “next” step by
step, as the user’s preferences are pre-congured in the CD. As well, the correct
device drivers have been installed properly, and it’s not necessary to update device
drivers in OS, which will save time and effort of MIS.
21Unbuffered DDR31333Single Rank, Dual Rank
22Unbuffered DDR31333Single Rank, Dual Rank
*Support Low Voltage DIMMs; **Down from 1066 or 1333 MHz DIMM
• Always install DIMMs with the same CAS latency. For optimum
compatibility, it is recommended that you obtain memory modules from the
same vendor. DO NOT combine RDIMM and UDIMM.
• The motherboard supports x8 DRAM Only and x4 & x16 DRAM are not
supported
ASUS RS300-E6 Series2-3
Page 16
Order P/NDescription
90-S000I0300TDDR3 1333 ECC REG 1G SINGLE PACK
90-S000I0310TDDR3 1333 ECC REG 2G SINGLE PACK
90-S000I0320TDDR3 1066 ECC REG 1G SINGLE PACK
90-S000I0330TDDR3 1066 ECC REG 2G SINGLE PACK
90-S000I0340TDDR3 1333 ECC UNB 1G SINGLE PACK
90-S000I0350TDDR3 1333 ECC UNB 2G SINGLE PACK
90-S000I0360TDDR3 1066 ECC UNB 1G SINGLE PACK
90-S000I0370T
90-S000I0380TDDR3 1333 ECC REG 1G (10 in 1)
90-S000I0390TDDR3 1333 ECC REG 2G (10 in 1)
90-S000I0400T
90-S000I0410TDDR3 1066 ECC REG 2G (10 in 1)
90-S000I0420TDDR3 1333 ECC UNB 1G (10 in 1)
90-S000I0430TDDR3 1333 ECC UNB 2G (10 in 1)
90-S000I0440TDDR3 1066 ECC UNB 1G (10 in 1)
90-S000I0450TDDR3 1066 ECC UNB 2G (10 in 1)
DDR3 1066 ECC UNB 2G SINGLE PACK
DDR3 1066 ECC REG 1G (10 in 1)
Chapter 1: Product introduction2-4
Page 17
2.3 Upgrading hard disk drives
The system supports eight hot-swap SATAII/SAS hard disk drives.
We recommend that you install identical drives of the same model and capacity
for RAID conguration.
Order P/NDescription
90-S000H6210THDD SAS 450G 3.5” with tray (Single Pack)*
90-S000H6220THDD SAS 300G 3.5” with tray (Single Pack)*
90-S000H6230THDD SAS 146G 3.5” with tray (Single Pack)*
90-S000H6240THDD SATA2 1T 3.5” with tray (Single Pack)
90-S000H6250THDD SATA2 750G 3.5” with tray (Single Pack)
90-S000H6260THDD SATA2 500G 3.5” with tray (Single Pack)
90-S000H6270THDD SATA2 320G 3.5” with tray (Single Pack)
90-S000H6280THDD SATA2 250G 3.5” with tray (Single Pack)
*SAS hard disk drives are supported by RS300-E6/PS4 only.
ASUS RS300-E6 Series2-5
Page 18
2.4 Installing ASUS PIKE SAS RAID card
PIN1 PIN2 PIN3PIN1 PIN2 PIN3
S
A
T
A
3
S
A
T
A
4
S
A
T
A
1
S
A
T
A
2
SATA1
SATA2
SATA3
SATA4
The ASUS PIKE SAS RAID card allows users to create RAID 0, 1, 5, 10 and 50
from SAS hard disk drives connected to the SAS connectors on the motherboard.
Move the
SGPIO_SEL1
jumper on the SATA/SAS backplane to 2–3.
Order P/NDescription
90-C1SCM0-00UAY00Z PIKE 1064E (4-port SAS support Firmware RAID 0,1,1E)
90-C1SDB0-00XBN00Z PIKE 6480 (8-port SAS support Firmware RAID 0,1,10,5) (10 in 1)
90-C1SCN5-00UAY00Z PIKE 1078 (8-port SAS support Hardware RAID 0,1,10,5,50,6,60)
Chapter 1: Product introduction2-6
Page 19
2.5 Installing ASUS Server Management
12
12
Board
ASUS Server Management Board is an Intelligent Platform Management Interface
(IPMI) 2.0-compliant board that allows users to monitor, control and manage a
remote server from the local or central server in local area network (LAN).
• Monitor the running status of major components via LAN or Serial Port, such
as CPU and memory utilization, storage capacity and networking transfer rate.
• Advanced server management functions including “remote power on/off/reset”,
“remote control via SOL (Serial-over LAN)” and “remote SEL (system event log
reading when the system is out-of-band)”.
• Support Dynamic Host Conguration Protocol (DHCP), which avoids
manually assigning IP address by setting DHCP mode to receive IP address
automatically.
Use the LAN3 port for
server management.
Order P/NDescription
90-C1SD80-00UAN00ZASMB4-iKVM Module (6 in 1)
ASUS RS300-E6 Series2-7
LAN port 3
Page 20
2.6 Installing PCI express cards
1
2
3
1
2
3
The system supports PCIe x16 cards installation on the PCIe riser card brackets.