Embedded Power for
Business-Critical Continuity
NLP65 Series
Single, dual,
and triple output
Special Features
• Universal Input
• 3" x 5" footprint
• Low profile fits 1U applications
• EN61000-3-2 compliance
option (HCC)
• Overvoltage and short circuit
protection
• 65 W with free air convection
cooling
• EN55022, EN55011 conducted
emissions level B
• EN61000-4-2,-3,-4, -5, -6
immunity compliant
• RoHS compliant
• LPX80 enclosure kit available
• 2 year warranty
Total Power: 65 - 75W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc*
# of Outputs: Single, dual,
triple
Safety
VDE0805/EN60950/IEC950
File No. 1040100-3336-0096
Licence No. 114404
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
China Compulsory
Certification 60950
*NLP65-76xx version only
Rev.07.01.08
NLP65 Series
1 of 4
Electrical Specifications
Input
Input voltage range Universal input, 85-264 Vac
(See Note 2)
NLP65-76xx version only 120-370 Vdc
Input frequency range 47-63 Hz
Input current
(cold start)
120 Vac 17 A max.
230 Vac 32 A max.
Safety ground
leakage current
120 Vac, 60 Hz 0.7 mA
230 Vac, 50 Hz 1.4 mA
Input current 120 Vac, with PFC 1.05 A rms
230 Vac, with PFC 0.51 A rms
120 Vac, without PFC 1.40 A rms
230 Vac, without PFC 0.80 A rms
Input fuse UL/IEC127 S3.15 A, 250 Vac In live and neutral
Output
Total regulation
(line and load)
Main output ±2.0%
Auxiliary outputs ±5.0%
Rise time At turn-on 1.0 s, max
Transient response Main output 5.0% or 250 mV
25% step max. dev., 1ms max.
at 0.1 A/μs recovery to 1%
Temperature coefficient ±0.02%/°C
Overvoltage protection Main outputs 125%, ±10%
Short circuit protection Cyclic operation Continuous
Minimum output current Single and multiple (See Note 6)