ARRIS DG950 User Manual

Touchstone®DG950
Data Gateway
User’s Guide
Get ready to experience the Internet’s express lane! Whether you’re checking out streaming media, downloading new software, or checking your email, the Touch­stone DG950 Data Gateway brings it all to you faster and more reliably with both wired and wireless connectivity.
The Touchstone Data Gateway provides four Ethernet connections for use as the hub of your home/office Local Area Network (LAN). The Touchstone Data Gateway also provides 802.11a/b/g/n wireless connectivity for enhanced mobility and ver­satility.
Installation is simple and your cable company will provide assistance to you for any special requirements. The links below provide more detailed instructions.
Safety Requirements
Getting Started
Installing and Connecting Your Data Gateway
Configuring Your Ethernet Connection
Using the Data Gateway
Troubleshooting
Glossary

Export Regulations

This product may not be exported outside the U.S. and Canada without U.S. Department of Commerce, Bureau of Export Admin istration au­thorization. Any export or re-export by the purchaser, directly or indirectly, in contravention of U.S. Export Adminis tration Regulation is prohib­ited.
Copyright © 2012 ARRIS. All rights reserved.
The information in this document is subject to change without notice. The statements, configurations, technical data, and recom mendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsi­bility for their applications of any products specified in this document. The information in this docu ment is proprietary to ARRIS.
ARRIS, Touchstone, and the ARRIS logo are trademarks or registered trademarks of ARRIS Group. All other trademarks and reg istered trade­marks are the property of their respective holders.
ARSVD01338 Release 9 Standard 1.4 March 2012
Safety
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary

Safety Requirements

ARRIS Data Gateways comply with the applicable requirements for performance, construction, labeling, and information when used as outlined below:
CAUTION
Risk of shock
Mains voltages inside this unit. No user serviceable parts inside. Refer service to qualified personnel only!
Do not use product near water (i.e. wet basement, bathtub, sink or near a swimming pool, etc.), to avoid risk of electrocu tion.
Do not use spray cleaners or aerosols on the Data Gateway.
Avoid using and/or connecting the equipment during an electri cal storm, to avoid risk of electrocution.
Do not locate the equipment within 6 feet (1.9 m) of a flame or ignition source (i.e. heat registers, space heaters, fireplaces, etc.).
Use only power supply and power cord included with the equip ment.
Equipment should be installed near the power outlet and should be easily accessible.
The shield of the coaxial cable must be connected to earth (grounded) at the entrance to the building in accordance with applicable national electrical in­stallation codes. In the U.S., this is required by NFPA 70 (National Electrical Code) Article 820. In the European Union and in certain other countries, CATV instal lation equipotential bonding requirements are specified in IEC 60728-11, Cable networks for television signals, sound signals and interac- tive services, Part 11: Safety. This equipment is in tended to be installed in accordance with the requirements of IEC 60728-11 for safe operation.
If the equipment is to be installed in an area serviced by an IT power line network, as is found in many areas of Norway, spe cial attention should be given that the installation is in accor dance with IEC 60728-11, in particular Annex B and Figure B.4.
Touchstone DG950 Data Gateway User’s Guide
3
Safety
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary
In areas of high surge events or poor grounding situations and areas prone to lightning strikes, additional surge protection may be required (i.e. PF11VNT3 from American Power Conver sion) on the AC, RF, and Ethernet lines.
When the Data Gateway is connected to a local computer through Ethernet cables, the computer must be proper ly grounded to the building/residence AC ground network. All plug-in cards within the computer must be properly installed and grounded to the computer frame per the manufacturer’s spec­ifications.
Ensure proper ventillation. Position the Data Gateway so that air flows freely around it and the ventillation holes on the unit are not blocked.
Do not mount the Data Gateway on surfaces that are sensitive to heat and/or which may be damaged by the heat generated by the unit, its power supply, or other accessories.
Touchstone DG950 Data Gateway User’s Guide
4
Safety
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary

FCC Part 15

This equipment has been tested and found to comply with the requirements for a Class B digital device under Part 15 of the Federal Communications Commission (FCC) rules. These requirements are intended to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in ac­cordance with the instructions, may cause harmful interference to radio communi­cations. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the fol­lowing measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved by the party re­sponsible for compliance could void the user’s authority to operate the equipment.
Touchstone DG950 Data Gateway User’s Guide
5
Safety
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary

European Compliance

This product complies with the provisions of the Electromagnetic Com patibility (EMC) Directive (89/336/EEC), the Amending Directive (92/31/EEC), the Low Volt­age Directive (73/23/EEC), and the CE Marking Directive (93/68/EEC). As such, this product bears the CE marking in accordance with the above applicable Direc­tive(s).
A copy of the Declaration of Conformity may be obtained from: ARRIS Interna­tional, Inc., 3871 Lakefield Drive, Suite 300, Suwanee, GA 30024.
As indicated by this symbol, disposal of this prod uct is governed by Directive 2002/96/EC of the European Parliament and of the Council on waste electrical and electronic equipment (WEEE). WEEE could potentially prove harmful to the environment; as such, upon disposal of the Data Gateway the Directive requires that this product must not be disposed as unsorted munic ipal waste, but rather collected separately and dis posed of in accor­dance with local WEEE ordinances.
This product complies with directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances (RoHS) in electrical and electronic equip ment.
Touchstone DG950 Data Gateway User’s Guide
6
Safety
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary

Energy Consumption (DG950S Models only)

In accordance with Ecodesign Directive 2005/32/EC, this device is equipped with a power switch. The following energy consumption figures apply (measured with a wattmeter at the outlet):
Switch State Power Consumption
OFF 0.0 W
ON
8.0 W (idle)
11.5 W (typical)
Note: In most instances, ARRIS recommends that the power switch remain in
the ON position at all times. Turning the switch OFF disables the device. Turning the switch OFF is recommended only during vacations or similar extended absences.
Touchstone DG950 Data Gateway User’s Guide
7
Safety
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary

Getting Started

About Your New Data Gateway

The Touchstone DG950 Data Gateway is DOCSIS® 3.0 or Euro-DOCSIS™ 3.0 com­pliant with the following features:
Speed: much faster than dialup or ISDN service; up to eight times faster than DOCSIS 2.0 cable modems.
Convenience: supports Ethernet and 802.11a/b/g/n wireless connections; both can be used simultaneously
Flexibility: provides high speed data
Compatibility:
Data services: DOCSIS 3.0 or Euro-DOCSIS 3.0 compliant and back-
ward-compatible with DOCSIS 2.0 or 1.1; supports tiered data services (if offered by your cable company)
The DG950 provides:
Wireless 802.11a/b/g/n connectivity
Four Ethernet ports for connections to non-wireless devices
DG950A: DOCSIS 3.0 compliant DG950S: Euro-DOCSIS 3.0 compliant
One USB host port (future support for external USB devices)

What’s in the Box?

Make sure you have the following items before proceeding. Call your cable company for assistance if anything is missing.
Data Gateway
Power Cord
Wall-Mounting Template and Instructions
Quick Installation Guide
Ethernet Cable (CAT5e)
Touchstone DG950 Data Gateway User’s Guide
8
Safety
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary
End User License Agreement

Items You Need

If you are installing the Data Gateway yourself, make sure you have the follow ing items on hand before continuing:
Coax Cable
Data Gateway package: see What’s in the Box?
for a list of items in the
package.
Coaxial cable (coax): as shown in the image to the left, this is a round cable with a connector on each end. It is the same kind of wire used to con­nect to your television for cable TV. You can buy coax from any electronics retailer and many discount stores; make sure it has connectors on both ends. There are two types of connectors, slip-on and screw-on; the screw­on connectors are best for use with your Data Gateway. The coax should be long enough to reach from your Data Gateway to the nearest cable outlet.
Note: For best performance, use high-quality RG-6 type coax cable and min­imize or eliminate splitters between the cable jack and the Data Gateway.
Splitter (optional): provides an extra cable connection by splitting a sin­gle outlet into two. You may need a splitter if you have a TV already con­nected to the cable outlet that you want to use. You can buy a splitter from any electronics retailer and most discount stores; you may also need a short piece of coax cable (with connectors); use it to connect the splitter to the cable outlet and then connect the Data Gateway and TV to the splitter.
Note: A splitter effectively cuts the signal in half and sends each half to its two outputs. Using several splitters in a line may deteriorate the quality of your television and/or internet connection.
Wall-mount hardware (optional): if you want to wall-mount your Data Gateway, you need to obtain two drywall anchors or wood screws. See the Wall-Mount Template and Instructions for more details.
Information packet: your cable company should furnish you with a packet containing information about your service and how to set it up. Read this in­formation carefully and contact your cable company if you have any ques­tions.
Touchstone DG950 Data Gateway User’s Guide
9
Safety
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary

Getting Service

Before trying to use your new Data Gateway, contact your local cable company to establish an Internet account. When you call, have the fol lowing information ready:
the Data Gateway serial number and cable MAC addresses of the unit (printed on a sticker on the bottom of the Data Gateway)
the model number of the Data Gateway
If the Data Gateway was provided by your cable company, they already have the required information.
In addition, you should ask your cable company the following questions:
Do you have any special system requirements or files that I need to down­load after I am connected?
When can I start using my Data Gateway?
Do I need a user ID or password to access the Internet or my e-mail?
Touchstone DG950 Data Gateway User’s Guide
10
Safety
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary

System Requirements

The Touchstone Data Gateway operates with most computers. The following de­scribes requirements for each operating system; see the documentation for your system for details on enabling and configuring networking.
To use the Data Gateway, you need DOCSIS or Euro-DOCSIS high-speed Internet service from your cable company.

Recommended Hardware

The following hardware configuration is recommended. Computers not meeting this configuration can still work with the DG950, but may not be able to make maximum use of DG950 throughput.
CPU: P4, 3GHz or faster
RAM: 1GB or greater
Hard drive: 7200 RPM or faster
Ethernet: Gig-E (1000BaseT)
Note: CAT5e Ehternet cable is required for gigabit Ethernet (Gig-E), not reg­ular CAT5 cable.

Windows

Windows XP, Windows Vista, or Windows 7. A supported Ethernet or wireless LAN connection must be available.

MacOS

MacOS X. A supported Ethernet or wireless LAN connection must be available.

Linux/other Unix

Hardware drivers, TCP/IP, and DHCP must be enabled in the kernel. A supported Ethernet or wireless LAN connection must be available.
Touchstone DG950 Data Gateway User’s Guide
11
Safety

 
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary

About this Manual

This manual covers the Touchstone DG950 Data Gateway. The model number is on the label affixed to the Data Gateway. See the image at the left.

What About Security?

Having a high-speed, always-on connection to the Internet requires a certain amount of responsibility to other Internet users—including the need to maintain a reasonably secure system. While no system is 100% secure, you can use the fol­lowing tips to enhance your system’s security:
Keep your operating system updated with the latest security patches. Run the system update utility at least weekly.
Keep your email program updated with the latest security patches. In addi­tion, avoid opening email containing attachments, or opening files sent through chat rooms, whenever possible.
Install a virus checker and keep it updated.
Model Number
Security Label
Avoid providing web or file-sharing services over your Data Gateway. Be­sides certain vulnerability problems, most cable companies prohibit run ning servers on consumer-level accounts and may suspend your account for vi­olating your terms of service.
Use the cable company’s mail servers for sending email.
Avoid using proxy
software unless you are certain that it is not open for abuse by other Internet users (some are shipped open by default). Crimi­nals can take advantage of open proxies to hide their identity when break­ing into other computers or sending spam. If you have an open proxy, your ca ble company may suspend your account to protect the rest of the net­work.
Wireless LAN security is enabled by default on the Data Gateway (for the same reasons that you should run only secured proxies). See the security label (shown on image at the left) for the factory security settings. If you need to modify the wireless security settings, see Configuring Your Wireless
Connection.
Touchstone DG950 Data Gateway User’s Guide
12
Safety
Getting Started Installation
Ethernet Cable
Ethernet
Configuration Usage Troubleshooting Glossary

Ethernet or Wireless?

There are two ways to connect your computer (or other equipment) to the Data Gateway. The following will help you decide which is best for you:
Ethernet
Ethernet is a standard method of connecting two or more computers into a Local Area Network (LAN). You can use the Ethernet connection if your computer has built-in Ethernet hardware.
Note: To connect more than four computers to the DG950 through the Ether-
net ports, you need an Ethernet hub (available at computer retail ers).
The Data Gateway package comes with one 6-foot (1.9m) Ethernet cable (the con­nectors look like wide telephone connectors); you can purchase more cables if nec­essary at a computer retailer. If you are connecting the Data Gateway di rectly to a computer, or to an Ethernet hub with a cross-over switch, ask for Category 5e (CAT5e) straight-through cable. CAT5e cable is required for gigabit Ethernet (Gig­E), not regular CAT5 cable.

Wireless

Wireless access lets you connect additional (wireless-capable) devices to Data Gate­way. The 802.11 wireless LAN standard allows one or more computers to access the DG950 using a wireless (radio) signal. These connections are in addition to the con­nections supported via Ethernet.
Note: You can use the wireless connection if your computer has a built-in or af-
termarket wireless card. To learn more about which wireless hardware works best with your com puter, see your computer dealer.

Both

If you have two or more computers, you can use Ethernet for up to four devices and wireless for the others. To connect five or more computers to the Ethernet ports, you will need an Ethernet hub (available at computer retailers.)
Touchstone DG950 Data Gateway User’s Guide
13
Safety
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary

Installing and Connecting Your Data Gateway

Before you start, make sure that:
You have contacted your cable company and verified that they provide data service using standard DOCSIS technology.
You have all the items you need
Cable and power outlets are available near the computer. If a cable outlet is not conveniently located, your cable company can install a new one.
If you have ordered service, your cable company should configure the Data Gate­way automatically. You need only follow the instructions in this section to install and connect the Data Gateway.
.
Touchstone DG950 Data Gateway User’s Guide
14
Safety
DG950
Power
LAN
DS
US
Online
WLAN
Getting Started Installation
Ethernet
Configuration Usage Troubleshooting Glossary
DG950A/S
B
ECA
D F
G

Front Panel

The front of the Data Gateway has the following indicators:
A WPS button/indicator: begins associating the Data Gateway with a wireless
device. Light indicates Wireless Protected Setup (WPS) is active.
B WLAN: indicates the status of the wireless LAN.
C LAN: indicates Ethernet connectivity between the Data Gateway and com-
puters.
D Online: indicates internet data transmission status.
E US: indicates upstream connectivity.
F DS: indicates downstream connectivity.
G Power: indicates whether AC power is available to the unit.
Touchstone DG950 Data Gateway User’s Guide
15
Loading...
+ 34 hidden pages