ARRIS and the ARRIS logo are all trad emarks of ARRIS E nterprises, Inc. Other
trademarks and trade names may be used in this document to refer to either the entities
claiming the marks and the names of their products. ARRIS disclaims proprietary
interest in the ma rks and names of ot hers.
ARRIS provides this guide without warranty of any k i nd, implied or expressed, including,
but not limited to, the implied warranties of merchantability and fitness for a particular
purpose. ARRIS m ay make improveme nts or changes in the product(s) described in this
manual at any time.
The capabilities , system requireme nts and/or compatibility with third-party p roducts
described herein are subject to change without notice.
Patent Notice
Protected under one or more of the following U.S. patents: http://www.arris.com/legal
Other patents pendi ng.
Release 16 STANDARD 1.3 March 2015 Touchstone DG1680 Data Gateway User Guide 4
Overview
Introduction
Get ready to experience the Internet’s express lane! Whether you’re checking out streaming
media, downloading ne w software, checking your email, or talking with friends on the
phone, the Touchstone D G1680 Data Gateway brings it all to you f aster and more re liably.
The Touchstone DG1680 Data Gateway provides four Ethernet connections for use as the
hub of your home/office Local Area Network (LAN). The DG1680 also provides
802.11a/b/g /n/ac wireless connectivity for enhanced mobility an d versatility. The Data
Gateway also offe rs i ntegrated MoCA 2.0 home networking providing Internet access and
transfer of multimedia content between devices over coaxial cable in the home.
Chapter 1
Installation is simple and your cable company will provide assistance to you for any special
requirements.
Release 16 STANDARD 1.3 March 2015 Touchstone DG1680 Data Gateway User Guide 5
Getting Support
If you need assista nce with your ARRIS product plea se contact your cable com pany.
For additional technical information and product User Guides please visit the ARRIS
Support website at http://www.arris.com/consumer.
Chapter 1: Overview
Release 16 STANDARD 1.3 March 2015 Touchstone DG1680 Data Gateway User Guide 6
Safety Require men t s
The ARRIS Data Gateway complies wit h the applicable requirements for performance,
construction, labeling, and information when used as outlined below:
CAUTION
Risk of shock
Mains voltages inside this unit. No user serviceable parts inside. Refer service to qualified personnel
only!
Do not use product near water (i.e. wet basement, bathtub, sink or near a swim ming
pool, etc.), to avoid risk of elec trocuti on .
The product shall be cleaned using only a damp, lint-free, cloth. No solvents or
cleaning agents shall be used.
Chapter 2
Do not use spray cleaners or aerosols on the gateway.
Avoid using and/or connecting the equipment durin g an electrical storm, to avoid risk
of electrocuti on.
Do not locate the equipment within 6 feet (1.9 m) of a flame or ignition source (i.e. heat
registers, space he aters, fireplaces, etc.).
Use only the AC power a dapter (if provided) and power cord included with the
equipment.
Equipment should be installed near the power outlet and should be easily accessible.
The shield of the coaxial cable must be connected to earth (grounded) at the entrance
to the building in accordance with applicable national electrical installation codes. In
the U.S., this is re quired by NFPA 70 (National Electrical Code) Article 820. In the
European Union and in certain other countries, CATV installation equipotential
bonding requirements are specified in IEC 60728-11, Cable networks for television signals, sound signals and interactive services, Part 11: Safety. This equi pment is
intended to be installed in accordance with the requirements of IEC 60728-11 for safe
operation.
If the equipment is to be installed in an area serviced by an IT power line network, as is
found in many areas of Norway, special attention should be given that the installation
is in accordance with IEC 60728-11, in particular Annex B and Figure B.4.
In areas of high surge events or poor grounding situations and areas prone to lightning
strikes, additional surge protection may be required (i.e. PF11VNT3 from American
Power Conversion) on the AC, RF, Ethernet and Phone li nes.
When the Data Gateway is connected to a local computer thr ou gh Ethernet cables, the
computer must be properly grounde d to the building/re sidence AC ground network. All
plug-in cards within the computer must be p roperly installed and grounded to the
computer frame per the manufacturer’s spe ci fica t ions.
Release 16 STANDARD 1.3 March 2015 Touchstone DG1680 Data Gateway User Guide 7
Ensure proper venti lation. Position the Data Gateway so that air flows fre ely around it
and the ventilation holes on the unit are not blocked.
Do not mount the Data Gateway on surfaces that are sensi ti ve to heat and/or which
may be damaged by the heat generated by the modem, its power supply, or other
accessories.
FCC Part 15
This equipment has been tested and found to comply with the requirements for a Class B
digital device under Part 15 of the Federal Communications Commission (FCC) rules.
These requirements are intended to provide reasonable protection aga i nst harmful
interference in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one
or more of the followi ng measures:
Reorient or relocate the receiving antenna.
Chapter 2: Safety Requirements
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
WARNING
Changes or modifications to this equipment not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
RF Exposure
This equipment c omplies with FCC radiation exposu re limits set forth for an uncontroll ed
environment. This equipment should be installed and operated with minimum distance of
7.9 inches (20cm) between the radiator and your body. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter.
Industry Canada Compliance
Under Industry Canada regulations, this radio transmitter may only operate using an
antenna of a type and maximum (or lesser) gain appro ved for the transmitter by Industry
Canada. To reduce potential radio interference to other users, the antenna type and its gain
should be so chosen that the equiva lent isotropically radiated power (e.i.r.p.) is not more
than that necessary for successful communication.
This device complies with Industry Canada li cense-exempt RSS standard(s). Opera tion is
subject to the followin g two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including i nterference that may cause undesire d
operation of the device.
Release 16 STANDARD 1.3 March 2015 Touchstone DG1680 Data Gateway User Guide 8
For Mexico
The operation of t his equipment is subject to the following two condition s: (1) This
equipment or device cannot cause harmful interference and (2) this equipment or device
must accept any interference, including interference that may cause some unwanted
operation of the equipment.
Chapter 2: Safety Requirements
Release 16 STANDARD 1.3 March 2015 Touchstone DG1680 Data Gateway User Guide 9
Getting Started
About Your New Data Gateway
The Touchstone DG1680 Data Ga teway is DOCSIS compliant wit h the following features:
Speed: much faster than dialup or I SDN service; up to twe nty four times faster than
DOCSIS 2.0 cable modems.
Convenience: supports Ethernet and 802.11a/b/g/n/ac wireless connections; both can
be used simultaneously
Compatibility:
• Data services: DOC SIS 3.0 compliant an d backward-compatible with DOCSIS 2.0
or 1.1; supports ti ered data services (if offered by your cable company)
The DG1680 provides:
Chapter 3
2.4 GHz radio and 5 GHz radio for wireless 802.11a/b/g/n/ac connectivity
Four Ethernet ports for connections to non-wireless devices
Integrated MoCA 2. 0 home networkin g
DOCSIS 3.0 compliant
One USB host port (future support for e xternal USB devices)
What's in the Box
Make sure you have the following items before proceeding. Call your cable company for
assistance if anything is missing.
Data Gateway
Power Cord
Wireless Connection Configuration Guide
Ethernet Cable
End User License Agreement
Items You Need
If you are installing the Data Gateway yourself, make sure you have the following items on
hand before continuing:
Data Gateway package: see What's in the Box (page 10) f or a list of items in the
package.
Release 16 STANDARD 1.3 March 2015 Touchstone DG1680 Data Gateway User Guide 10
Chapter 3: Getting Started
Coaxial cable (coax): This is a round cable with a connector on each end. It is the
same kind of wire used to connect to your television for cable TV. You can buy coax
from any electronics retailer and many discount stores; make sure it has connectors on
both ends. There are two types of conne ctors, slip-on and screw-on; the screw-on
connectors are be st for use with your Data Gateway. The coax should be long enough to
reach from your Data Gateway to the nearest cable outlet.
Note: For best performance, use high-quality RG-6 type coax cable and minimize or
eliminate splitters between the cable jack and the Data Gateway.
Splitter (optional): provides an extra cable connection by splitting a single outlet
into two. You may need a splitte r if y ou have a TV already connected to the cable outlet
that you want to use. You can buy a splitter from any e lectronics retailer and most
discount stores; you may also need a short piece of coax cable (with conn ectors); use it
to connect the splitter to the cable outlet and then connect the Data Gateway and TV to
the splitter.
Note: A splitter effectively cuts the signal in half and sends each half to its two outputs.
Using several splitters in a line may deteriorate the quality of your television, telephone, and/or
internet connection.
Information packet: your cable c ompany should furnish you with a pack et
containing information about your service and how to set it up. Read this information
carefully and contact your cable company if you have any questions.
Getting Service
Before trying to use your new Data Gateway, contact your local cable company to establish
an Internet account and telephone service. When you call, have the following information
ready:
the Data Gateway serial number and cable MAC addresses of the unit (pri nted on the
Data Gateway)
the model number of the Data Gateway (printed on the Data Gateway)
If the Data Gateway was provided by your cable company , they already have the required
information.
In addition, you should ask your cable company the following questions:
Release 16 STANDARD 1.3 March 2015 Touchstone DG1680 Data Gateway User Guide 11
Do you have any special system requirements or files that I need to downl oad after I
am connected?
When can I start using my Data Gateway?
Do I need a user ID or password to acce ss the Internet or my e-mail?
System Requirements
The Touchstone Data Gateway operates with most computers. The following de scribes
requirements for each operating syste m; see the documen tation for your system for details
on enabling and configuring networking.
To use the Data Gateway, you nee d DOCSIS high-speed Internet service from your cable
company.
Recommended Hardware
The following hardware configuration is recommended. Computers not meeting this
configuration can still work with the DG1680, but may not be able to make maximum use
of DG1680 throughput.
Chapter 3: Getting Started
CPU: P4, 3GHz or faster
RAM: 1GB or greater
Hard drive: 7200 RPM or faster
Ethernet: Gig-E (1000BaseT)
Windows
Windows XP , Windows Vista, Windows 7, or Windows 8. A supported Ethernet or
wireless LAN connection must be available.
MacOS
System 7.5 to MacOS 9.2 (Open Transport recomme nded) or MacOS X. A supported
Ethernet or wirel ess LAN connection must be available.
Linux/other Unix
Hardware drivers, TCP/IP, and DHCP must be enabled in the kernel. A su pported
Ethernet or wirel ess LAN connection must be available.
Release 16 STANDARD 1.3 March 2015 Touchstone DG1680 Data Gateway User Guide 12
Loading...
+ 27 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.