35
-592590
550
550
-
870
866
35
35
35
-
601
592
870
866
0
445
2
87°
595
896
865
18
24
1
576
569
569
545
238
110
GESM 55 IX A 30

12NC/Fx: F158728 GTIN (EAN) code:

8050147587287
DIMENSION MEASURE
OVERALL CABINET
MIN Height of the wall cabinet niche, including all required space for installation or ventilation 0 mm
MIN Height of the tall cabinet niche, including all required space for installation or ventilation 590 mm
MIN Height of the base cabinet niche, including all required space for installation or ventilation 592 mm
MAX Height of the wall cabinet niche, including all required space for installation or ventilation 0 mm
MAX Height of the tall cabinet niche, including all required space for installation or ventilation 592 mm
MAX Height of the base cabinet niche, including all required space for installation or ventilation 601 mm
MIN Width of the wall cabinet niche, including all required space for installation or ventilation 0 mm
MIN Width of the tall cabinet niche, including all required space for installation or ventilation 866 mm
MIN Width of the base cabinet niche, including all required space for installation or ventilation 866 mm
MAX Width of the wall cabinet niche, including all required space for installation or ventilation 0 mm
MAX Width of the tall cabinet niche, including all required space for installation or ventilation 870 mm
MAX Width of the base cabinet niche, including all required space for installation or ventilation 870 mm
MIN Depth of the wall cabinet niche, including all required space for installation or ventilation 0 mm
MIN Depth of the tall cabinet niche, including all required space for installation or ventilation 550 mm
MIN Depth of the base cabinet niche, including all required space for installation or ventilation 550 mm
Space in front, which is required to install bottom trim 2 mm
Indicates whether a ventilation opening is needed or not. Default is "N" Yes
WALL CABINET (vent-shaft incoming)
Indicates the position of the freespace for the inbound airflow (wall cabinet) -
Minimum space or inbound ventilation (wall cabinet) 0 mm
Minimum area for inbound ventilation cavity (wall cabinet) 0 cm²
WALL CABINET (vent-shaft outgoing)
Indicates the position of the freespace for the outbound airflow (wall cabinet) -
Minimum space or outbound ventilation (wall cabinet) 0 mm
Minimum area for outbound ventilation cavity (wall cabinet) 0 cm²
TALL CABINET (vent-shaft incoming)
Indicates the position of the freespace for the inbound airflow (tall cabinet) Rear
Minimum space for inbound ventilation (tall cabinet) 35 mm
Minimum area for inbound ventilation cavity (tall cabinet) 283 cm²
TALL CABINET (vent-shaft outgoing)
Indicates the position of the freespace for the outbound airflow (tall cabinet) Rear
Minimum space for outbound ventilation (tall cabinet) 35 mm
Minimum area for outbound ventilation cavity (tall cabinet) 283 cm²
BASE CABINET (vent-shaft incoming)
Indicates the position of the freespace for the inbound airflow (base cabinet) Rear
Minimum space for inbound ventilation (base cabinet) 35 mm
Minimum area for inbound ventilation cavity (base cabinet) 283 cm²
BASE CABINET (vent-shaft outgoing)
Indicates the position of the freespace for the outbound airflow (base cabinet) Rear
Minimum space for outbound ventilation (base cabinet) 35 mm
Minimum area for outbound ventilation cavity (base cabinet) 283 cm²
DIMENSION MEASURE
APPLIANCE
Height of the front 595 mm
Width of the front 896 mm
Depth of the front 24 mm
Maximum depth all protruding elements, e.g. handles, controls 43 mm
Lateral clearance between front edge and most protruding elements which avoid to open a neighbour front more than 90 degrees
Projection of front in relation to housing of appliance 18 mm
Projection of front in relation to bearing area of the appliance. Taken at minimum height of appliance, if height is adjustable
When product panel is missing, set to 0 110 mm
Space in front, which is required to guarantee full operability. The most protruding part gives this dimension
Height from bearing area of appliances and lower handle 452 mm
Frontal handle thickness 30 mm
Frontal handle width 521 mm
MIN Height of the product body 551 mm
MAX Height of the product body 576 mm
Width of the product body 865 mm
Depth of the product body 545 mm
Full depth of product excluding protruding interface elements 569 mm
- - mm
- - mm
- - mm
- - mm
- - mm
- - mm
Appliance can be used as base for other appliances from the same manufacturer. Default is "No" No
Appliance Flap door
Projection of the opened flap in relation to bearing area 0 mm
Maximum angle when flap door is opened totally 87 mm
Appliance Side swing door
Lateral projection of front incl. controls when door is opened totaly. At the side where the hinge is mounted
Lateral projection of opened front at the side where the hinge is fixed 0 mm
Maximum angle when door is opened totally 0 mm
Appliance other
Depth from front end of the niche to the front end of the freespace of the retrace 238 mm
Height from niche to bottom end of freespace for the retrace 569 mm
162 mm
1 mm
445 mm
0 mm