Aprilaire 8191, 8192 User Manual

SPECIFICATIONS AND SIZING SUMMARY
MODEL 8191 8192
Ventilator
With Dehumidification
Model 8191/8192 | Specification Sheet
Nominal ventilation airflow
(CFM)
Capacity
Energy factor
Energy star qualified Yes No
0.0 in WC 160 CFM 265 CFM
0.2 in WC 120 CFM 230 CFM
0.4 in WC 70 CFM 200 CFM
Voltage, Phase, Frequency 120VAC, 1, 60 Hz
Current draw
Sound level
Width 12½" 12½"
Height
Length 25" 27½"
Weight 70 lbs 75 lbs
(1)
pints/day 70 ppd 95 ppd
(1)
Air flow @ various external static pressure - dry coil
(1)
Dimensions - cabinet only
(2)
1.91 L/kW-h 2.2 L/kW-h
6.3 amps 8.0 amps
47 dBA ducted
54 dBA ducted
51 dBA unducted
14½" 14½"
Operating Condition
FEATURES
+ Removes moisture from outdoor air before it enters the live space
+ Unit is designed, when properly installed, to achieve ASHRAE
Standard 62.2-2010
+ Integral moisture and ventilation control
+ Optional ventilation control via thermostat (see below)
+ High and Low Temperature Limit Lock-outs
+ Simple plug-in installation
+ Installation temperature range up to 140°
RECOMMENDED CONTROLS
+ Aprilaire Thermostat Models
- 8620, 8620W
+ Aprilaire Communicating Thermostat Models
- 8820
- 8910, 8910W - 8920W
- 8830 - 8840
Inlet air operating conditions 50°F - 104°F, 40°F dew point min.
Ambient/Ventilation 40°F - 140°F, 0% - 99% RH
(1)
Rated capacity and Energy Factor test done and current draw measure in accordance with AHAM
DH-1 2008 at 80°F/60%RH inlet air at 0.0 ESP.
(2)
Height does not include adjustable feet or casters. The width excludes the filter doors, and length excludes the duct collars.
SPECIFICATIONS
Control Built-in digital control with display
Control mounting option Field interchangeable from top to front
Cabinet insulation 1/2" EPS
Air discharge orientation Top or end air discharge
Inlet/Outlet duct collars 10" round
Back damper at outlet Included
Air filter Washable MERV 8
Refrigeration R-410A
Coil type Corrosion resistant aluminum
8' Power cord type Plug type
Drain connection
Warranty 5 years
(3)
Thread adapter and barbed fitting for clear drain tubing included.
(3)
3/4" PVC adapters
BENEFITS
+ Helps control RH in the home during periods when the
air conditioning system does not run long enough to remove sufficient moisture. If air conditioner can satisfy RH requirements, the Aprilaire unit’s compressor shuts off
+ Optimize energy savings by locking out ventilation during
hottest/coldest times of the day
+ Improves indoor air quality
+ Installation labor reduced, requires only a power outlet and
24 volt wiring to HVAC system
When properly installed and set, the Aprilaire Model 8191 and Model 8192 ventilators with dehumidification will meet the mechanical ventilation requirements of:
+ Energy Star Certified Homes, Version 3
+ EPA Indoor airPLUS, Version 1
+ 2012 & 2015 International Residential Code (IRC)
+ 2012 & 2015 International Energy Conservation Code
(IECC) – 8191 Only
15.08
15⁄"
14½"
MODE button used
to access ventilation time setting
12.50
12½"
14.50
1⁄"to 2"
1.38 to 2.00
10.00
10"
ON/OFF button used to turn
the ventilator on and off
35.50
35½"
27.50 4.004.00
27½" 4"4"
3/4” PIPE, INSIDE
¾"
10.00
10"
90-1971
UP/DOWN buttons used
to change humidity or vent time setting
Ducting the Ventilator
GABLE END WALL, BAND JOIST, OR PORCH SOFFIT
10x6 ROUND TRANSITION
DEHUM
FRESH AIR
INTAKE HOOD
W/SCREEN
FRESH AIR
MODEL 6506 NORMALLY CLOSED DAMPER
AprilairePartners.com
Form No. 3039 • 281877 08.18 ©2018 Aprilaire – Division of Research Products Corporation
APRILAIRE RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.
VENTILATOR
FRESH AIR INTAKE DUCT
FILTER
RETURN MIXING BOX
10” DIA. DUCT
P.O. Box 1467 Madison, WI 53701-1467
800.334.6011 F: 608.257.4357
FURNACE/AIR HANDLER
AIR FLOWAIR FLOW
Loading...