Aprilaire 8142 User Manual

814 2
10.50
13.13
15.00
Overall Dimensions 6.6" H x 13.1" W x 13.4" L including control
Inlet Collar 6" Round
Outlet Collar 6" Oval
Ventilation Time Dial Setting O, 15-60 minutes, (5 min increments),
Ambient Temperature 0°F to 160°F
VENTILATOR WITH BACKDRAFT DAMPER NO FILTER
SPECIFICATIONS
Test/Reset
Outdoor Temperature
Voltage 115 VAC, 1 phase, 60 Hz
Power Includes 5’ power cord with 3 prong plug
Ducting 6" diameter flexible insulated duct
Warranty 5 years
ETL
15.00
Setting "A", no limit, time only
“B”, 105°F high limit, 20°F low limit
“C”, 100°F high limit, 30°F low limit
“D”, 95°F high limit, 40°F low limit
Tested to UL Standard 705 – Power Ventilators
Not For Outdoor Use
10.50
13.13
FEATURES
+ Unit is designed, when properly installed,
to achieve ASHRAE Standard 62.2 2010
+ Operates a minimum of one hour out of
every four to meet 2012/2015 IRC requirements
+ Complies with 2012 & 2015 IECC (2.8 cfm/watt)
+ Control is integrated into the ventilator
+ High and Low Temperature Limit Lock-outs while
maintaining ASHRAE 62.2 2010
+ Simple plug-in installation
+ Installation temperature range up to 160°F
BENEFITS
+ The precise amount of outside air needed in today’s
efficiently designed homes is delivered
+ Optimize energy savings by locking out ventilation
during hottest/coldest times of the day
+ Improves indoor air quality
+ Robust design handles hot attics up to 160°F
+ Installation labor reduced, requires only a switched
outlet and 24 volt wiring to HVAC system
+ Furnace or air handler does not require an ECM motor
to meet efficacy requirement
11.88
13.41
4.50
6.63
When properly installed and set, the Aprilaire Model 8142 Fresh Air Ventilator will meet the mechanical ventilation requirements of:
+ Energy Star Certified Homes, Version 3
+ EPA Indoor airPLUS, Version 1
+ 2012 & 2015 International Residential Code (IRC)
+ 2012 & 2015 International Energy
Conservation Code (IECC)
+ California Energy Commission Title 24
PERFORMANCE
Static Pressure*
(in WC)
Airflow
(CFM)
0.0 245 0.63 3.30
0.2 220 0.64 2.96
0.4 190 0.64 2.57
0.6 160 0.63 2.12
0.8 120 0.61 1.69
1.0 95 0.60 1.35
* Measured across ventilator.
Typical Attic Installation
FRESH AIR INTAKE VENTILATOR DUCTED TO SUPPLY DUCT
FRESH AIR INTAKE VENTILATOR WITH VENTILATION CONTROLLER
Current (amps)
GABLE END WALL, BAND JOIST, OR PORCH SOFFIT
Ecacy
(CFM/watt)
Mounting Bracket Dimensions
INCHES
8.88
RETURN MIXING BOX
FRESH AIR
FURNACE/AIR HANDLER
AIR FLOW
FILTER
FRESH AIR INTAKE DUCT
Alternate Attic Installation
FRESH AIR INTAKE VENTILATOR DUCTED TO RETURN DUCT
FRESH AIR INTAKE VENTILATOR WITH VENTILATION CONTROLLER
MODEL 6506 DAMPER
FRESH AIR INTAKE DUCT
FRESH AIR
FURNACE/AIR HANDLER
FILTER
RETURN MIXING BOX
AIR FLOW
FRESH AIR INTAKE HOOD W/SCREEN
GABLE END WALL, BAND JOIST, OR PORCH SOFFIT
FRESH AIR INTAKE HOOD W/SCREEN
13.44
16.09
AprilairePartners.com